Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
GE Port J Gastroenterol ; 30(Suppl 1): 52-56, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37818401

RESUMEN

Introduction: Endoscopic techniques are now considered the first-line approach for the management of bariatric surgery-related fistulas. The off-label use of cardiac septal defect occluders (CSDO) is an emerging technique that has demonstrated favorable outcomes for the closure of extravascular defects, including gastrointestinal (GI) disruptions. Previous case reports have reported similar results with the CSDO Amplatzer™ for the management of GI disruptions following bariatric surgery. However, the use of similar alternative devices for this purpose has not yet been described. Case Presentation: This case report presents the first reported use of the Occlutech® CSDO for the treatment of a chronic gastrocutaneous fistula after bariatric revisional surgery. Despite apparent initial success - no extravasation of contrast material through the device in the contrast study after the CSDO placement - fistula closure failed due to partial dislodgement of the device. The placement of a second device between the discs of the former one ultimately sealed the fistulous orifice. Discussion: In chronic GI fistulas, the mature tract is often not liable to the application of standard endoscopic methods, leading to failed closure attempts. A new application of Occlutech® CSDO can obviate the clinical burden of a high-risk laparotomy in these cases. Appropriate endoscopic equipment as well as the involvement of a multidisciplinary team are prime conditions to ensure successful patient outcomes.


Introdução: As técnicas endoscópicas são atualmente consideradas abordagens de primeira linha no manejo das fístulas associadas a cirurgia bariátrica. O uso off-label de dispositivos de oclusão do septo cardíaco (CSDO) é uma técnica nova que tem demonstrado resultados favoráveis no encerramento de defeitos extra-vasculares, incluindo fístulas gastrointestinais. Relatos de caso prévios reportaram resultados semelhantes com o CSDO Amplatzer ™ para o tratamento de fístulas gastrointestinais pós cirurgia bariátrica. No entanto, o uso de dispositivos alternativos semelhantes para esse fim ainda não foi descrito. Relato de Caso: Este relato de caso apresenta o primeiro uso reportado do CSDO Occlutech® para tratamento de fístula gastrocutânea crônica após cirurgia bariátrica revisional. Apesar do aparente sucesso inicial ­ nenhum extravasamento de contraste através do dispositivo na fluoroscopia após a colocação do CSDO, houve recorrência da drenagem fistulosa devido ao deslocamento parcial do dispositivo. A colocação de um segundo dispositivo entre os discos do primeiro acabou por encerrar o orifício fistuloso. Discussão: Nas fístulas gastrointestinais crônicas, o trajeto epitelizado muitas vezes não é passível de aplicação dos métodos endoscópicos tradicionais, levando a múltiplas tentativas fracassadas de encerramento. A nova aplicação de Occlutech® CSDO pode evitar o risco de uma laparotomia de alto risco nesses casos. Equipamentos endoscópicos adequados, bem como o envolvimento de equipe multidisciplinar são condições primordiais para garantir o sucesso do tratamento.

2.
J. Transcatheter Interv ; 31(supl.1): 3-3, jul.-set. 2023.
Artículo en Portugués | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1512137

RESUMEN

INTRODUÇÃO: A incidência de ductus arteriosus patente (PCA) pode chegar a 50% em pacientes prematuros. Quando hemodinamicamente significativos, podem ser responsáveis por tempo de ventilação mecânica prolongado, além de importante fator de risco para o aparecimento de enterocolite necrotizante, hemorragia intraventricular e displasia broncopulmonar nesta população. O advento do dispositivo Amplatzer Duct Occluder II Additional Sizes (ADO II AS) (Abbot Structural Heart, Plymouth, MN) revolucionou o tratamento do PCA em pacientes prematuros com menos de 2Kg e, mais recentemente, o dispositivo Piccolotm (Abbot Structural Heart, Plymouth, MN) foi especificamente desenhado para o fechamento percutâneo de canal arterial nesta população e aprovado pelo FDA. OBJETIVO: Verificar se o fechamento percutâneo do canal arterial hemodinamicamente significativo no paciente prematuro é uma alternativa terapêutica segura, eficiente e eficaz. MÉTODOS: Trata-se de estudo prospectivo, inédito no Brasil, em andamento, que compreendeu 40 pacientes consecutivos submetidos a fechamento percutâneo de canal arterial entre 2020 e 2023 em 13 instituições no Brasil. RESULTADOS: A idade gestacional média ao nascimento foi de 28,94 semanas (desvio padrão populacional 3,12 e amostral 5,60), a idade média no momento do procedimento foi de 33,61 dias (desvio padrão populacional 16,64 e amostral 16,10) e o peso médio de 1,39 Kg (desvio padrão populacional 0,39 e amostral 0,39). Dentre eles, 84% necessitavam de ventilação mecânica e 41% tinham feito uso de, em média, 1,45 ciclos de anti-inflamatórios não esteroides. A maioria dos pacientes teve melhora dos parâmetros ventilatórios e o tempo médio de extubação foi de 13,71 dias (desvio padrão populacional 8,30 e amostral 9,71). A taxa de sucesso foi de 100%. Não houve mortalidade relacionada ao procedimento. CONCLUSÕES: O fechamento percutâneo do canal arterial é um procedimento eficaz e extremamente seguro em pacientes prematuros graves com baixíssima taxa de complicações e associado a melhora dos padrões ventilatórios. Este procedimento é uma realidade no Brasil podendo ser realizado em diversos centros do país que possuem profissionais capacitados para o tratamento percutâneo de cardiopatias congênitas em pacientes prematuros.

3.
J. Transcatheter Interv ; 31(supl.1): 4-4, jul.-set. 2023.
Artículo en Portugués | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1512160

RESUMEN

INTRODUÇÃO: O implante percutâneo de valva pulmonar foi introduzido em 2000 como uma alternativa de baixo risco para pacientes previamente operados com disfunção da via de saída do ventrículo direito (VSVD). Até recentemente, pacientes com VSVD nativas e ectásicas não eram candidatos a essa terapêutica devido à ausência de um dispositivo adequado a esta população no Brasil. O advento da MyVal (Meril Life Sciences, Gujarat, India), uma válvula balão-expansível, com diâmetros de 30,5mm e 32mm proporcionou o tratamento destes pacientes que frequentemente já possuem cirurgias prévias com risco cirúrgico de nova intervenção muito alto. OBJETIVO: Descrever os resultados imediatos da experiência inicial brasileira do implante de MyVal em vias de saída nativas e ectásicas em diferentes centros do país. MÉTODOS: 14 pacientes foram submetidos ao implante percutâneo de MyVal para o tratamento da disfunção da via de saída nativa e ectásica. A idade média dos pacientes foi de 31,3 anos (14-67) e o peso médio de 66,4 Kg (40-90). Todos os pacientes, à exceção de um idoso que havia sido diagnosticado com estenose de valva pulmonar, foram submetidos a, pelo menos, um procedimento cirúrgico previamente. RESULTADOS: O implante foi bem-sucedido em todos os pacientes, tendo sido realizado sem pré-stent. A via de saída mediu em média 27,6mm (20-32) e após a insuflação de balão Cristal 30mm, mediu em média 29,8mm (28-32,5). Foram implantadas 3 valvas 30,5mm com diâmetro final médio de 30,1mm (30- 30,5) e 11 valvas 32mm com diâmetro final de 32,8mm (32-35). Não houve complicações ou mortalidade relacionadas ao procedimento Todos os pacientes apresentaram insuficiência pulmonar trivial no ecocardiograma antes da alta hospitalar. CONCLUSÕES: Atualmente, esta é a maior experiência mundial implante de valva pulmonar com MyVal de calibres 30,5 e 32mm. O implante de valva pulmonar é um procedimento seguro e efetivo que substitui a troca valvar cirúrgica e beneficia principalmente pacientes com toracotomias prévias. O implante da MyVal de calibres de 30,5 e 32mm propiciou o tratamento de pacientes com vias de saída ectásicas e que não possuíam alternativa percutânea atualmente no Brasil. Diâmetro final pode chegar a 35mm sem o surgimento de insuficiência pulmonar. Pré-stent não é necessário na maioria dos casos.


Asunto(s)
Disfunción Ventricular Derecha , Prótesis e Implantes
4.
Arq. bras. cardiol ; 120(5 supl. 6): 15-15, maio. 2023.
Artículo en Portugués | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1443654

RESUMEN

FUNDAMENTO: O implante percutâneo de valva pulmonar foi introduzido em 2000 como uma alternativa de baixo risco para pacientes previamente operados com disfunção da via de saída do ventrículo direito (VSVD). Até recentemente, pacientes com VSVD nativas e ectásicas não eram candidatos a essa terapêutica devido à ausência de um dispositivo adequado a esta população no Brasil. O advento da MyVal (Meril Life Sciences, Gujarat, India), uma válvula balãoexpansível, com diâmetros de 30,5mm e 32mm proporcionou o tratamento destes pacientes que frequentemente já possuem cirurgias prévias com risco cirúrgico de nova intervenção muito alto. OBJETIVO: Descrever os resultados imediatos da experiência inicial brasileira do implante de MyVal em vias de saída nativas e ectásicas em diferentes centros do país. Amostra e MÉTODOS: 13 pacientes foram submetidos ao implante percutâneo de MyVal para o tratamento da disfunção da via de saída nativa e ectásica. A idade média dos pacientes foi de 32,6 anos (14-67) e o peso médio de 69,3Kg (45-90). Todos os pacientes, à exceção de um idoso que havia sido diagnosticado com estenose de valva pulmonar, foram submetidos a, pelo menos, um procedimento cirúrgico previamente. RESULTADOS: O implante foi bem-sucedido em todos os pacientes, tendo sido realizado sem pré-stent. A via de saída mediu em média 27,7mm (20-32) e após a insuflação de balão Cristal 30mm, mediu em média 29,8mm (28-32). Foram implantadas 4 valvas 30,5mm com diâmetro final médio de 30,3mm (30-30,5) e 9 valvas 32mm com diâmetro final de 33,3mm (32- 35). Não houve complicações ou mortalidade relacionadas ao procedimento Todos os pacientes apresentaram insuficiência pulmonar trivial no ecocardiograma antes da alta hospitalar. CONCLUSÃO: Atualmente, esta é a maior experiência mundial implante de valva pulmonar com MyVal de calibres 30,5 e 32mm. O implante de valva pulmonar é um procedimento seguro e efetivo que substitui a troca valvar cirúrgica e beneficia principalmente pacientes com toracotomias prévias. O implante da MyVal de calibres de 30,5 e 32mm propiciou o tratamento de pacientes com vias de saída ectásicas e que não possuíam alternativa percutânea atualmente no Brasil. Diâmetro final pode chegar a 35mm sem o surgimento de insuficiência pulmonar. Préstent não é necessário na maioria dos caso. Palavras-chave: cateterismo; congênitos; implante de valva pulmonar.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Valvuloplastia con Balón
5.
Arq Bras Cardiol ; 119(3): 460-467, 2022 09.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-36074378

RESUMEN

BACKGROUND: The presence of patent ductus arteriosus can be as high as 50% in preterm babies. Hemodynamically significant patent ductus arteriosus is a common cause of delayed weaning of respiratory support and an important risk factor of necrotizing enterocolitis, intraventricular hemorrhage, and bronchopulmonary dysplasia in this population. OBJECTIVE: The aim of this study is to describe an initial experience of percutaneous closure of the ductus arteriosus in preterm infants weighing less than 2 kg. METHODS: This was a prospective study, comprised of 14 consecutive patients submitted to percutaneous closure of ductus arteriosus between March 2020 and February 2021 in 6 institutions in Brazil. RESULTS: Mean gestational age was 28.45±3.14 weeks, mean age at the procedure was 38.85±17.35 days and mean weight was 1.41 ±0.41 kg; 79% of the patients were under mechanical ventilation, and 79% had been submitted, on average, to a 1.5 cycle of non-steroidal anti-inflammatory drugs. Most patients were weaned off of mechanical ventilation in a mean of 12.6 ±7.24 days after the procedure. Success rate was 100%. No procedure-related mortality was observed. CONCLUSION: This study concluded that percutaneous closure of ductus arteriosus in premature babies below 2 kg has satisfactory results and a low complication rate in this study sample.


FUNDAMENTO: A incidência de ductus arteriosus patente (PCA) pode chegar a 50% em pacientes prematuros. Quando hemodinamicamente significativo, pode ser responsável por tempo de ventilação mecânica prolongado, além de importante fator de risco para o aparecimento de enterocolite necrotizante, hemorragia intraventricular e displasia broncopulmonar nessa população. OBJETIVO: O objetivo deste estudo é descrever a experiência inicial do fechamento percutâneo de canal arterial em prematuros pesando menos de 2 kg. MÉTODOS: Trata-se de estudo prospectivo que compreendeu 14 pacientes consecutivos submetidos a fechamento percutâneo de canal arterial de março de 2020 a fevereiro de 2021 em 6 instituições no Brasil. RESULTADOS: A idade gestacional média ao nascimento foi de 28,45 ±3,14 semanas, a idade média no momento do procedimento foi de 38,85 ±17,35 dias e o peso médio de 1,41±0,41 kg. Dentre os prematuros, 79% necessitavam de ventilação mecânica e 79% tinham feito uso de, em média, 1,5 ciclos de anti-inflamatórios não esteroides. A maioria dos pacientes teve melhora dos parâmetros ventilatórios e o tempo médio de extubação foi de 12,6 ±7,24 dias. A taxa de sucesso foi de 100%. Não houve mortalidade relacionada ao procedimento. CONCLUSÃO: Este estudo concluiu que o fechamento percutâneo do canal arterial em prematuros é uma realidade no Brasil, com resultados satisfatórios e baixa taxa de complicações.


Asunto(s)
Conducto Arterioso Permeable , Conducto Arterial , Brasil/epidemiología , Conducto Arterioso Permeable/cirugía , Humanos , Ibuprofeno , Lactante , Recién Nacido , Recien Nacido Prematuro , Estudios Prospectivos
6.
Arq. bras. cardiol ; 119(3): 460-467, set. 2022. ilus, tab
Artículo en Inglés, Portugués | LILACS, CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1403349

RESUMEN

FUNDAMENTO: A incidência de ductus arteriosus patente (PCA) pode chegar a 50% em pacientes prematuros. Quando hemodinamicamente significativo, pode ser responsável por tempo de ventilação mecânica prolongado, além de importante fator de risco para o aparecimento de enterocolite necrotizante, hemorragia intraventricular e displasia broncopulmonar nessa população. OBJETIVO: O objetivo deste estudo é descrever a experiência inicial do fechamento percutâneo de canal arterial em prematuros pesando menos de 2 kg. MÉTODOS: Trata-se de estudo prospectivo que compreendeu 14 pacientes consecutivos submetidos a fechamento percutâneo de canal arterial de março de 2020 a fevereiro de 2021 em 6 instituições no Brasil. RESULTADOS: A idade gestacional média ao nascimento foi de 28,45 ±3,14 semanas, a idade média no momento do procedimento foi de 38,85 ±17,35 dias e o peso médio de 1,41±0,41 kg. Dentre os prematuros, 79% necessitavam de ventilação mecânica e 79% tinham feito uso de, em média, 1,5 ciclos de anti-inflamatórios não esteroides. A maioria dos pacientes teve melhora dos parâmetros ventilatórios e o tempo médio de extubação foi de 12,6 ±7,24 dias. A taxa de sucesso foi de 100%. Não houve mortalidade relacionada ao procedimento. CONCLUSÃO: Este estudo concluiu que o fechamento percutâneo do canal arterial em prematuros é uma realidade no Brasil, com resultados satisfatórios e baixa taxa de complicações.


BACKGROUND: The presence of patent ductus arteriosus can be as high as 50% in preterm babies. Hemodynamically significant patent ductus arteriosus is a common cause of delayed weaning of respiratory support and an important risk factor of necrotizing enterocolitis, intraventricular hemorrhage, and bronchopulmonary dysplasia in this population. OBJECTIVE: The aim of this study is to describe an initial experience of percutaneous closure of the ductus arteriosus in preterm infants weighing less than 2 kg. METHODS: This was a prospective study, comprised of 14 consecutive patients submitted to percutaneous closure of ductus arteriosus between March 2020 and February 2021 in 6 institutions in Brazil. RESULTS: Mean gestational age was 28.45±3.14 weeks, mean age at the procedure was 38.85±17.35 days and mean weight was 1.41 ±0.41 kg; 79% of the patients were under mechanical ventilation, and 79% had been submitted, on average, to a 1.5 cycle of non-steroidal anti-inflammatory drugs. Most patients were weaned off of mechanical ventilation in a mean of 12.6 ±7.24 days after the procedure. Success rate was 100%. No procedure-related mortality was observed. CONCLUSION: This study concluded that percutaneous closure of ductus arteriosus in premature babies below 2 kg has satisfactory results and a low complication rate in this study sample.


Asunto(s)
Humanos , Recién Nacido , Conducto Arterial , Cardiopatías Congénitas , Neonatología , Recién Nacido , Recien Nacido Prematuro , Cateterismo
7.
Arq. bras. cardiol ; 119(2 supl.3): 11-11, ago,2022.
Artículo en Portugués | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1402264

RESUMEN

FUNDAMENTO: A incidência de ductus arteriosus patente (PCA) pode chegar a 50% em pacientes prematuros. Quando hemodinamicamente significativos, podem ser responsáveis por tempo de ventilação mecânica prolongado, além de importante fator de risco para o aparecimento de enterocolite necrotizante, hemorragia intraventricular e displasia broncopulmonar nesta população. O advento do dispositivo Amplatzer Duct Occluder II Additional Sizes (ADO II AS) (Abbot Structural Heart, Plymouth, MN) revolucionou o tratamento do PCA em pacientes prematuros com menos de 2Kg e, mais recentemente, o dispositivo Piccolotm (Abbot Structural Heart, Plymouth, MN) foi especificamente desenhado para o fechamento percutâneo de canal arterial nesta população e aprovado pelo FDA. OBJETIVO: Descrever a experiência inicial no Brasil do fechamento percutâneo do canal arterial em pacientes prematuros. Delineamento e MÉTODOS: Trata-se de estudo prospectivo, inédito no Brasil, em andamento, que compreendeu 36 pacientes consecutivos submetidos a fechamento percutâneo de canal arterial de março de 2020 a maio de 2022 em 13 instituições no Brasil. RESULTADOS: A idade gestacional média ao nascimento foi de 29,12 semanas (desvio padrão populacional 3,15 e amostral 5,79), a idade média no momento do procedimento foi de 33,50 dias (desvio padrão populacional 15,15 e amostral 15,36) e o peso médio de 1,41Kg (desvio padrão populacional 0,40 e amostral 0,40). Dentre eles, 84% necessitavam de ventilação mecânica e 41% tinham feito uso de, em média, 1,45 ciclos de anti-inflamatórios não esteroides. A maioria dos pacientes teve melhora dos parâmetros ventilatórios e o tempo médio de extubação foi de 14,23 dias (desvio padrão populacional 8,64 e amostral 9,97). A taxa de sucesso foi de 100%. Não houve mortalidade relacionada ao procedimento. CONCLUSÃO: O fechamento percutâneo do canal arterial é um procedimento eficaz e extremamente seguro em pacientes prematuros graves com baixíssima taxa de complicações e associado a melhora dos padrões ventilatórios. Este procedimento é uma realidade no Brasil podendo ser realizado em diversos centros do país que possuem profissionais capacitados para o tratamento percutâneo de cardiopatias congênitas em pacientes prematuros.


Asunto(s)
Recien Nacido Prematuro , Conducto Arterioso Permeable , Cardiopatías Congénitas , Conducto Arterial
8.
Arq. bras. cardiol ; 115(6): 1154-1161, dez. 2020. tab, graf
Artículo en Inglés, Portugués | LILACS | ID: biblio-1152938

RESUMEN

Resumo Fundamento Nos últimos anos, o recente aumento no número de procedimentos intervencionistas tem resultado em crescente preocupação em relação à exposição radiológica por pacientes e equipe médica. A avaliação da exposição dos níveis de radiação em crianças é difícil devido à grande variabilidade no peso corporal. Portanto, os valores de referência de radiação não estão bem definidos para essa população. Objetivos Avaliar e validar a razão do produto dose-área (DAP) em relação ao peso corporal como uma medida de referência de radiação em cateterismos cardíacos em crianças. Métodos Estudo multicêntrico observacional com dados do Registro Brasileiro de Cateterismo Cardíaco em Cardiopatias Congênitas (CHAIN) de março de 2013 a junho de 2014. Os critérios de inclusão foram: pacientes <18 anos submetidos a procedimentos hemodinâmicos para cardiopatia congênita, com DAP devidamente registrado. Foram considerados diferenças estatísticas significativas os valores de p < 0,05. Resultados Este estudo avaliou 429 pacientes com idade e peso medianos de 50 (10, 103) meses e 15 (7, 28) kg, respectivamente. O DAP mediano foi de 742,2 (288,8, 1.791,5) μGy.m2. Houve uma boa correlação entre o DAP e o produto peso/tempo de fluoroscopia (rs=0,66). Não foi observada diferença estatisticamente significativa na relação DAP/peso entre procedimentos terapêuticos e diagnósticos. Houve ampla variação da relação DAP/peso entre os procedimentos terapêuticos (p<0.001). Conclusões A proporção DAP/peso é a medida mais simples e aplicável para avaliar a exposição radiológica em uma população pediátrica. Apesar da escassa literatura disponível, as doses obtidas no presente estudo foram semelhantes àquelas encontradas anteriormente. Estudos de validação e comparação são importantes na avaliação do impacto de estratégias para redução da exposição radiológica nessa população. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background In recent years the increasing number of interventional procedures has resulted in growing concerns regarding radiation exposure for patients and staff. The evaluation of radiation exposure in children is difficult due to the great variability in body weight. Therefore, reference levels of radiation are not well defined for this population. Objectives To study and validate the ratio of dose-area product (DAP) to patient weight as a reference measurement of radiation for hemodynamic congenital heart disease procedures in children. Methods This observational multicenter study uses data obtained from a Brazilian registry of cardiac catheterization for congenital heart disease from March 2013 to June 2014. Inclusion criteria were all patients aged <18 years old undergoing hemodynamic procedures for congenital heart disease, with recorded DAP doses. P-value < 0.05 was considered as statistically significant. Results This study evaluated 429 patients with median age and weight of 50 (10, 103) months and 15 (7, 28) kg, respectively. Median DAP was 742.2 (288.8, 1,791.5) μGy.m2. There was a good correlation between DAP and weight-fluoroscopic time product(rs=0.66). No statistically significant difference was observed in DAP/weight ratio between therapeutic and diagnostic procedures. There was a wide variation in the DAP/weight ratio among the therapeutic procedures (p<0.001). Conclusions The DAP/weight ratio is the simplest and most applicable measurement to evaluate radiation exposure in a pediatric population. Although there is limited literature available, the doses obtained in the present study were similar to those previously found. Ongoing research is important to evaluate the impact of strategies to reduce radiation exposure in this population (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Asunto(s)
Humanos , Preescolar , Niño , Adolescente , Anciano , Exposición a la Radiación/efectos adversos , Cardiopatías Congénitas , Dosis de Radiación , Brasil , Fluoroscopía , Cateterismo Cardíaco/efectos adversos , Radiografía Intervencional , Sistema de Registros
9.
Arq Bras Cardiol ; 115(6): 1154-1161, 2020 12.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-33084745

RESUMEN

BACKGROUND: In recent years the increasing number of interventional procedures has resulted in growing concerns regarding radiation exposure for patients and staff. The evaluation of radiation exposure in children is difficult due to the great variability in body weight. Therefore, reference levels of radiation are not well defined for this population. OBJECTIVES: To study and validate the ratio of dose-area product (DAP) to patient weight as a reference measurement of radiation for hemodynamic congenital heart disease procedures in children. METHODS: This observational multicenter study uses data obtained from a Brazilian registry of cardiac catheterization for congenital heart disease from March 2013 to June 2014. Inclusion criteria were all patients aged <18 years old undergoing hemodynamic procedures for congenital heart disease, with recorded DAP doses. P-value < 0.05 was considered as statistically significant. RESULTS: This study evaluated 429 patients with median age and weight of 50 (10, 103) months and 15 (7, 28) kg, respectively. Median DAP was 742.2 (288.8, 1,791.5) µGy.m2. There was a good correlation between DAP and weight-fluoroscopic time product(rs=0.66). No statistically significant difference was observed in DAP/weight ratio between therapeutic and diagnostic procedures. There was a wide variation in the DAP/weight ratio among the therapeutic procedures (p<0.001). CONCLUSIONS: The DAP/weight ratio is the simplest and most applicable measurement to evaluate radiation exposure in a pediatric population. Although there is limited literature available, the doses obtained in the present study were similar to those previously found. Ongoing research is important to evaluate the impact of strategies to reduce radiation exposure in this population (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).


FUNDAMENTO: Nos últimos anos, o recente aumento no número de procedimentos intervencionistas tem resultado em crescente preocupação em relação à exposição radiológica por pacientes e equipe médica. A avaliação da exposição dos níveis de radiação em crianças é difícil devido à grande variabilidade no peso corporal. Portanto, os valores de referência de radiação não estão bem definidos para essa população. OBJETIVOS: Avaliar e validar a razão do produto dose-área (DAP) em relação ao peso corporal como uma medida de referência de radiação em cateterismos cardíacos em crianças. MÉTODOS: Estudo multicêntrico observacional com dados do Registro Brasileiro de Cateterismo Cardíaco em Cardiopatias Congênitas (CHAIN) de março de 2013 a junho de 2014. Os critérios de inclusão foram: pacientes <18 anos submetidos a procedimentos hemodinâmicos para cardiopatia congênita, com DAP devidamente registrado. Foram considerados diferenças estatísticas significativas os valores de p < 0,05. RESULTADOS: Este estudo avaliou 429 pacientes com idade e peso medianos de 50 (10, 103) meses e 15 (7, 28) kg, respectivamente. O DAP mediano foi de 742,2 (288,8, 1.791,5) µGy.m2. Houve uma boa correlação entre o DAP e o produto peso/tempo de fluoroscopia (rs=0,66). Não foi observada diferença estatisticamente significativa na relação DAP/peso entre procedimentos terapêuticos e diagnósticos. Houve ampla variação da relação DAP/peso entre os procedimentos terapêuticos (p<0.001). CONCLUSÕES: A proporção DAP/peso é a medida mais simples e aplicável para avaliar a exposição radiológica em uma população pediátrica. Apesar da escassa literatura disponível, as doses obtidas no presente estudo foram semelhantes àquelas encontradas anteriormente. Estudos de validação e comparação são importantes na avaliação do impacto de estratégias para redução da exposição radiológica nessa população. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).


Asunto(s)
Cardiopatías Congénitas , Exposición a la Radiación , Adolescente , Anciano , Brasil , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Fluoroscopía , Humanos , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Radiografía Intervencional , Sistema de Registros
10.
Rev. bras. cardiol. invasiva ; 23(1): 73-76, abr.-jun.2015. ilus
Artículo en Portugués | LILACS | ID: lil-782181

RESUMEN

Pseudoaneurismas do ventrículo esquerdo são geralmente associados a infarto agudo do miocárdio, entretanto, podem surgir no pós-operatório tardio de cirurgias valvares, assim como os pseudoaneurismas aórticos. Acometem frequentemente pacientes com alto risco cirúrgico, e o tratamento percutâneo éhabitualmente realizado em centros de referência para o tratamento de cardiopatias congênitas devido às características anatômicas dos defeitos. Apresentamos dois casos de pseudoaneurismas do ventrículoesquerdo tratados por via transapical, sem necessidade de circulação extracorpórea, e um caso depseudoaneurisma aórtico tratado por via femoral, no qual foi utilizado laço por acesso contralateral para permitir suporte e direcionamento adequados da bainha longa para acessar o defeito...


Left ventricular pseudoaneurysms are usually associated with acute myocardial infarction; however, these conditions may emerge in the late postoperative period of valvar surgery, and this can also occur with aortic pseudoaneurysms. These pseudoaneurysms often affect patients with high surgical risk,and percutaneous treatment is usually performed in reference centers for treatment of congenital heartdiseases, due to anatomical characteristics of these defects. We present two cases of left ventricularpseudoaneurysms treated by transapical approach without need for cardiopulmonary bypass, and one caseof aortic pseudoaneurysm treated by femoral approach, in which a snare was introduced by contralateral access, to allow for adequate support and guidance of the long sheath for accessing the defect...


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Anciano , Aorta/cirugía , Cateterismo Cardíaco , Aneurisma Falso/complicaciones , Aneurisma Falso/terapia , Ventrículos Cardíacos/fisiopatología , Arteria Femoral , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico , Dispositivo Oclusor Septal , Infarto del Miocardio/complicaciones , Procedimientos Quirúrgicos Mínimamente Invasivos
11.
Rev. bras. cardiol. invasiva ; 22(4): 364-368, Oct-Dec/2015. tab, graf
Artículo en Portugués | LILACS | ID: lil-744577

RESUMEN

Introdução: A persistência do ducto arterioso é uma condição congênita de alta morbidade, especialmente em recém-nascidos prematuros de extremo baixo peso, representando 5 a 10% das cardiopatias congênitas. Nosso objetivo foi descrever as abordagens realizadas em hospital de referência para o tratamento da persistência do ducto arterioso com o método percutâneo de oclusão. Métodos: Foi realizado estudo retrospectivo do tratamento transcateter da persistência do ducto arterioso no período de abril de 2008 a abril de 2010. Resultados: Foram revisados 47 casos, a maioria (78,8%) tratada com molas Flipper®; os demais tratados com a prótese Amplatzer®. A configuração morfológica ductal foi do tipo A de Krichenko em 89,4% (34 no grupo molas Flipper® e 8 no grupo Amplatzer®), tipo D em 6,4% (2 no grupo molas Flipper® e 1 no grupo Amplatzer®) e tipo E em 4,2% (1 em cada grupo) dos pacientes. Os diâmetros mínimos pré-cateterismo foram de 2,6 ± 0,8 mm e 3,8 ± 1,6 mm para os grupos de molas Flipper® e Amplatzer®, respectivamente. Obteve-se oclusão imediata total do defeito na angiografia de controle em 72,3% dos pacientes tratados. Sete pacientes tratados com molas Flipper® receberam molas adicionais e os tratados com prótese Amplatzer® mostraram apenas shunts residuais mínimos em dois casos. Não ocorreram complicações do procedimento. No acompanhamento após a alta, um paciente permaneceu com mínimo shunt residual à ecografia, 45 dias após o cateterismo. Conclusões: A oclusão da persistência do ducto arterioso por método percutâneo tem-se mostrado segura e efetiva na maioria dos casos...


Background: Patent ductus arteriosus is a congenital condition with high morbidity, especially in preterm infants of extremely low birth weight, representing 5% to 10% of congenital heart diseases. Our objective was to describe the approaches used at a reference hospital for the percutaneous occlusion of PDA. Methods: We conducted a retrospective study on the transcatheter treatment of patent ductus arteriosus from April of 2008 to April of 2010. Results: Forty-seven cases were reviewed and most of them (78.8%) were treated with FlipperTM coils while the remaining patients received the AmplatzerTM device. Ductal morphological configuration was Krichenko type A in 89.4% (34 in the FlipperTM coil group and 8 in the AmplatzerTM group), type D in 6.4% (2 in the FlipperTM coil group and 1 in the AmplatzerTM group) and type E in 4.2% (1 in each group) of patients. Pre-catheterization minimum diameters were 2.6 ± 0.8 mm and 3.8 ± 1.6 mm for the FlipperTM coil and AmplatzerTM groups, respectively. Immediate total occlusion of the defect was obtained in the control angiography in 72.3% of the patients. Seven patients treated with the FlipperTM coil received additional coils and two patients treated with the AmplatzerTM device presented minimal residual shunts. There were no procedure-related complications. In the follow-up after hospital discharge, one patient presented minimal residual shunt at the echography, 45 days after catheterization. Conclusions: Percutaneous patent ductus arteriosus occlusion has proven to be safe and effective in most cases...


Asunto(s)
Humanos , Masculino , Femenino , Recién Nacido , Lactante , Conducto Arterial/anomalías , Dispositivo Oclusor Septal/efectos adversos , Cardiopatías Congénitas , Recién Nacido , Cateterismo/métodos , Ecocardiografía/métodos , Prótesis e Implantes/métodos , Estudio Observacional , Resultado del Tratamiento
12.
Arq Bras Cardiol ; 103(2): 131-7, 2014 Aug.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-25211313

RESUMEN

BACKGROUND: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. OBJECTIVES: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). METHODS: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). RESULTS: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. CONCLUSIONS: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.


Asunto(s)
Angiografía Coronaria/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Imagenología Tridimensional/métodos , Dosis de Radiación , Adolescente , Adulto , Niño , Preescolar , Angiografía Coronaria/efectos adversos , Femenino , Humanos , Lactante , Masculino , Valores de Referencia , Estudios Retrospectivos , Factores de Riesgo , Estadísticas no Paramétricas , Adulto Joven
13.
Rev. bras. cardiol. invasiva ; 22(3): 275-285, Jul-Sep/2014. tab, graf
Artículo en Portugués | LILACS-Express | LILACS, Sec. Est. Saúde SP | ID: lil-732784

RESUMEN

Introdução: Stress is associated with cardiovascular diseases.O implante percutâneo da válvula pulmonar é uma alternativa para condutos com disfunção. Descrevemos aqui a primeira experiência com o implante da válvula Melody® no Brasil. Métodos: Foram selecionados pacientes com estenose ou insuficiência pulmonar significativa em condutos de 16 a 22 mm. Foram empregadas técnicas padronizadas. Factibilidade, segurança e eficácia desse procedimento foram avaliadas. Resultados: Desde dezembro de 2013, dez pacientes (média de idade e peso de 16,5 anos e 49 kg, respectivamente) foram submetidos ao procedimento com intervalo médio de 11,9 ± 8,6 anos desde a última cirurgia. Insuficiência pulmonar foi indicação para o tratamento em três pacientes, estenose em dois e lesão mista em cinco. A válvula Melody® foi implantada com sucesso em todos os casos. A média da pressão sistólica do ventrículo direito e a relação ventrículo direito/ventrículo esquerdo diminuíram de 49,2 ± 15,9 para 35,8 ± 5,7 mmHg e de 0,55 ± 0,18 para 0,39 ± 0,08 mmHg (p < 0,01 para ambos). Não observamos estenose e nem insuficiência pulmonar residual significativa. Um paciente teve extravasamento contido requerendo um stent coberto e um segundo implante valvular. Todos os pacientes receberam alta do hospital em 72 horas. As válvulas funcionaram adequadamente ...


Background: Transcatheter pulmonary valve implantation is an alternative for dysfunctional conduits. We report the first experience with the MelodyTM valve implantation in Brazil. Methods: Patients with significant pulmonary stenosis or significant pulmonary insufficiency in conduits measuring 16 to 22 mm were enrolled. Standardized techniques were employed. The feasibility, safety and efficacy of this procedure were assessed. Results: From December 2013, ten patients (mean age and weight of 16.5 years and 49 kg, respectively) have undergone the procedure with a mean interval of 11.9 ± 8.6 years since the last surgery. Pulmonary insufficiency was an indication for treatment in three patients, pulmonary stenosis in two, and mixed lesion in five. The MelodyTM valve was successfully implanted in all cases. Mean right ventricular systolic pressure and right ventricle/left ventricle ratio decreased from 49.2 ± 15.9 to 35.8 ± 5.7 mmHg and from 0.55 ± 0.18 to 0.39 ± 0.08 mmHg (p < 0.01 for both). Significant residual pulmonary stenosis or pulmonary insufficiency was not observed. One patient had a contained conduit tear requiring a covered stent and a second valve implantation. All patients were discharged within 72 hours. The valves were properly functioning in a mean follow-up of 4.1 ± 2.2 months with no complications. Conclusions: Transcatheter MelodyTM valve implantation was feasible, safe and effective ...

14.
Arq. bras. cardiol ; 103(2): 131-137, 08/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-720809

RESUMEN

Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA. .


Fundamento: O uso da angiografia rotacional tridimensional (AR-3D) na avaliação de pacientes portadores de cardiopatia congênita parece ser promissor, apesar de haver pouca literatura disponível. Objetivos: O objetivo deste estudo foi descrever nossa experiência inicial com AR-3D, comparando sua dose de radiação com a da angiografia padrão bidimensional (AP-2D). Métodos: Entre setembro de 2011 e abril de 2012, 18 pacientes foram submetidos simultaneamente a AR-3D e AP-2D durante cateterização cardíaca diagnóstica. A dose de radiação foi avaliada através do produto dose-área (DAP). Resultados: A mediana de idade e de peso dos pacientes foi de, respectivamente, 12,5 anos e 47,5 kg. O DAP mediano de cada aquisição em AR-3D foi de 1093µGy.m2, e de 190µGy.m2 para cada aquisição em AP-2D (p < 0,01). Nos pacientes que pesavam mais de 45 kg (n=7), essa diferença foi menor, mas ainda significativa (1525µGy.m2 versus 413 µGy.m2, p = 0,01). Não houve diferença entre uma AR-3D e três AP-2D (1525µGy.m2 versus1238µGy.m2, p = 0,575) nesta população. Essa diferença foi significativamente maior em pacientes que pesavam menos de 45 kg (n = 9) (713 µGy.m2 versus 81 µGy.m2, p = 0,008), mesmo quando se comparou uma AR-3D com três AP 2D (242µGy.m2, respectivamente, p < 0,008). A AR-3D mostrou-se extremamente útil na avaliação de condutos de corações univentriculares, ramos pulmonares tortuosos e aorta em relação às aquisições em AP-2D. Conclusões: A dose de radiação da AR-3D em nossa instituição foi maior que a anteriormente relatada na literatura, sendo essa diferença mais evidente em crianças. Esse tipo de avaliação é de fundamental importância ...


Asunto(s)
Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Adulto Joven , Angiografía Coronaria/métodos , Cardiopatías Congénitas , Imagenología Tridimensional/métodos , Dosis de Radiación , Angiografía Coronaria/efectos adversos , Valores de Referencia , Estudios Retrospectivos , Factores de Riesgo , Estadísticas no Paramétricas
15.
Catheter Cardiovasc Interv ; 83(6): 953-63, 2014 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24459104

RESUMEN

BACKGROUND: Bare stents has become the first line therapy for aortic coarctation. Covered stents has been reported more recently in clinical practice. OBJECTIVES: The present study, reports comparatively 15-year experience of bare and covered stent implantation for aortic coarctation in a single tertiary referral center. METHODS: From 1997 to 2011, 143 patients with native or postoperative aortic coarctation were treated at our institution. Seventy-one subjects (median age 17 years (range from 4 to 70 years) underwent bare stent implantation (Group 1) while 72 patients (median age of 17.5 years (range from 6 to 68 years) underwent covered stent implantation (Group 2). RESULTS: Success rate in the whole group was 95%. More complex and tighter coarctations were treated using covered stents. Incidence of related-procedure adverse events was higher in Group 1 than in group 2 (21.1% vs. 8.3% P = 0.035). Aortic wall complications occurred in 7% of patients in Group 1 (one death) and 0% in Group 2 (P = 0.028). Subjects in Group 1 had a longer follow-up (median 85 vs. 35 months; P < 0.001). Independent predictors associated with reintervention included the presence of complex lesions (HR: 2.70; CI: 1.15-6.32), balloon diameter used <14 mm (HR: 3.76; CI: 1.48-9.55), and immediate residual gradient >10 mm Hg (HR: 4.30; CI: 1.96-9.47). CONCLUSIONS: Both bare and covered stent implantation for aortic coarctation is a safe and efficacious treatment. By using covered stent implantation the spectrum of patients treated has increased with lower rates of acute and late complications.


Asunto(s)
Coartación Aórtica/terapia , Procedimientos Endovasculares/instrumentación , Stents , Adolescente , Adulto , Anciano , Coartación Aórtica/diagnóstico , Aortografía , Niño , Preescolar , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Centros de Atención Terciaria , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
16.
Rev. bras. cardiol. invasiva ; 20(4): 408-412, out.-dez. 2012. tab
Artículo en Portugués | LILACS | ID: lil-666141

RESUMEN

INTRODUÇÃO: O diagnóstico precoce e o tratamento dos defeitos cardíacos congênitos têm reconhecido impacto na qualidade de vida dos pacientes. Nosso objetivo foi descrever a população de pacientes com cardiopatias congênitas submetidos a procedimentos diagnósticos ou terapêuticos percutâneos em um centro terciário. MÉTODOS: Análise retrospectiva de 1.002 pacientes submetidos a cateterismo cardíaco no período de 2003 a 2009 no Instituto de Cardiologia do Rio Grande do Sul. Variáveis demográficas, clínicas e do procedimento foram obtidas a partir de um banco de dados institucional e dos prontuários dos pacientes. RESULTADOS: A mediana de idade dos pacientes foi de 33 (0-73) anos e a de peso, de 23 (9,6-52,6) kg. Houve predominância do sexo feminino (52%), de doença acianótica (63,2%) e de diagnóstico realizado no período pós-natal (94,8%). Estenose pulmonar (22,9%), comunicação interatrial (22,5%) e persistência do canal arterial (21,6%) foram os defeitos acianóticos mais comuns, e tetralogia de Fallot foi a doença cianótica mais frequente (15,2%). A maioria dos procedimentos (58,6%) foi terapêutica, incluindo valvuloplastias pulmonares (32,9%), fechamento de comunicações interatriais (20,9%) e fechamento de persistências do canal arterial (15%). Em 19,2% dos pacientes foram observadas complicações, sendo os hematomas inguinais (7,8%) ou a febre (7,6%) as mais frequentes. Ocorreram 3 óbitos (0,3%) relacionados aos procedimentos. CONCLUSÕES: Os resultados deste estudo evidenciaram a predominância de procedimentos terapêuticos em pacientes com cardiopatias congênitas acianóticas, realizados com baixo índice de complicações, em centro terciário de referência.


BACKGROUND: Early diagnosis and treatment of congenital heart defects have a well-known impact on patient´s quality of life. This study aimed to describe the population of patients with congenital heart disease submitted to percutaneous diagnostic or therapeutic procedures at a tertiary referral center. METHODS: Retrospective analysis of 1,002 patients submitted to cardiac catheterization between 2003 and 2009 at Instituto de Cardiologia do Rio Grande do Sul. Clinical, demographic and procedure variables were obtained from an institutional database and patient charts. RESULTS: Median age was 33 (0-73) years and median weight was 23 (9.6-52.6) kg. Patients were predominantly females (52%), with acyanotic heart disease (63.2%) and postnatal diagnosis (94.8%). Pulmonary stenosis (22.9%), atrial septal defect (22.5%) and patent ductus ateriosus (21.6%) were the most common acyanotic heart defects, whereas tetralogy of Fallot was the most frequent cyanotic heart disease (15,2%). Most of the procedures (58,6%) were therapeutic, including pulmonary balloon valvuloplasty (32.9%), atrial septal defect closure (20.9%) and ductus arteriosus closure (15%). Complications were observed in 19.2% of patients, and inguinal hematomas (7.8%) and fever (7.6%) were the most frequent findings. There were 3 procedure-related deaths (0.3%). CONCLUSIONS: The study results demonstrated the prevalence of therapeutic procedures in patients with acyanotic heart disease, performed with a low complication rate at a tertiary referral center.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cateterismo/métodos , Cateterismo , Perfil de Salud
17.
J Invasive Cardiol ; 24(7): E148-52, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22781486

RESUMEN

The difficult performance of certain percutaneous interventions in the field of congenital heart disease is well known. Crossing pulmonary arteries in patients who have previously undergone surgical repair or stenotic pulmonary veins in infants can be typical examples of these technical challenges in the catheterization laboratory. The Venture wire 6 Fr control catheter (St Jude Medical) is compatible with a steerable tapered radiopaque tip that can be manually angulated (up to 90°) by clockwise rotation of a knob located in the proximal handle. This mechanism directs any 0.014″ guidewire and provides back-up support. This catheter has been successfully used in coronary artery intervention for crossing severely tortuous vessels, extreme angulations of side-branch ostia, jailed stents, saphenous vein graft anastomoses, and chronic total occlusions. We report the first use of the Venture wire control catheter (St Jude Medical) in the field of congenital heart disease. Patient #1 was diagnosed with pulmonary atresia and ventricular septal defect and had a proximally migrated stent in the pulmonary trunk and severe left pulmonary artery stenosis. We have used this catheter in order to cross this stent and perform left pulmonary artery stent placement. Patient #2 had postoperative vein restenosis after surgery. The Venture catheter was used to reach the obstructed insertion of the right medium lobe pulmonary vein from a transseptal approach. Techniques from coronary interventional colleagues can help interventional cardiologists in the field of congenital heart disease to treat complex situations.


Asunto(s)
Catéteres Cardíacos , Intervención Coronaria Percutánea/instrumentación , Atresia Pulmonar/terapia , Estenosis de la Válvula Pulmonar/terapia , Niño , Cardiopatías Congénitas/patología , Cardiopatías Congénitas/terapia , Humanos , Lactante , Masculino , Intervención Coronaria Percutánea/métodos , Arteria Pulmonar/patología , Atresia Pulmonar/patología , Estenosis de la Válvula Pulmonar/patología , Venas Pulmonares/patología , Resultado del Tratamiento
18.
Expert Rev Med Devices ; 9(2): 123-30, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22404773

RESUMEN

Aortic coarctation comprises approximately 7% of all known congenital heart defects. Surgery and balloon angioplasty have been performed for many years but are associated with a significant incidence of recoarctation and aneurysm formation. Although bare-stent implantation decreases the incidence of recoarctation, the risk of aortic dissection or aneurysm formation is not eliminated. Described initially to treat patients with coexistent aneurysm of the aortic wall, we currently believe that covered-stent implantation for aortic coarctation should play a more important role. Our increasing experience from expanding their indication to deal with complications from previous interventions, associated defects or particular anatomical situations has led us to conclude that most of cases of aortic coarctation in adolescents and adults should be treated by the implantation of covered stents.


Asunto(s)
Coartación Aórtica/terapia , Stents , Angioplastia de Balón , Coartación Aórtica/cirugía , Humanos , Implantación de Prótesis
19.
Rev. bras. cardiol. invasiva ; 19(4): 423-429, dez. 2011. tab, ilus
Artículo en Portugués | LILACS | ID: lil-618788

RESUMEN

Introdução: A abordagem percutânea é opção de escolha em neonatos portadores de estenose pulmonar crítica (EP) e atresia pulmonar com septo interventricular íntegro (APSI). Neste trabalho são descritos casos tratados consecutivamente em centro de referência e seu seguimento a médio prazo. Métodos: A maioria dos pacientes recebeu infusão endovenosa de prostaglandina pré-procedimento, independentemente da necessidade hemodinâmica. Na abordagem da APSI, foi utilizada guia de ponta rígida e, mais recentemente, valvotomia com cateter de radiofrequência. Na maioria dos casos, foi realizada dilatação sequencial com balão até atingir 110 a 120 do diâmetro do anel valvar pulmonar. Resultados: Entre 1998 e 2011, 17 neonatos com APSI (idade mediana de 5 dias, peso de 3,1 ± 0,6 kg) e 30 neonatos com EP (idade mediana de 12 dias, peso médio de 3 ± 1,4 kg) foram tratados em um serviço terciário. Na APSI, 14 pacientes foram abordados com guia rígida, com sucesso de 71,4, e 3 com radiofrequência, com sucesso de 100. Na EP, o sucesso foi alcançado em todos os casos. O óbito hospitalar foi de 23,5 no grupo com APSI e de 3,3 no grupo com EP, nenhum relacionado ao procedimento percutâneo. Na evolução a médio prazo, a taxa de reintervenção por reestenose foi de 21,4 no grupo com APSI e de 10 no grupo com EP. Conclusões: A valvoplastia pulmonar na EP e na APSI apresenta resultados clínicos e hemodinâmicos aceitáveis, desde que se observem características anatômicas favoráveis e se mantenha a patência do fluxo pulmonar até o procedimento. A morbidade e a mortalidade dos portadores de EP crítica são mais baixas que as de portadores de APSI.


BACKGROUND: The percutaneous approach is the therapy of choice in neonates with critical pulmonary stenosis (PS) and pulmonary atresia with intact interventricular septum (PAIVS). Consecutive cases treated at a reference center and their midterm follow-up was reported in this study. METHODS: Most of the patients received an intravenous infusion of prostaglandin preoperatively, regardless of the need. For the PAIVS approach, a stiff-tip guidewire was used and more recently, radiofrequency valvotomy. In most cases, sequential balloon dilation was performed until 110% to 120% of the pulmonary valve ring diameter was reached. RESULTS: Between 1998 and 2011, 17 neonates with PAIVS (median age of 5 days, mean weight of 3.1 + 0.6 kg) and 30 neonates with PS (median age of 12 days, mean weight of 3 + 1.4 kg) were treated at a tertiary center. In PAIVS patients, a stiff-tip guidewire was used in 14 cases, with a success rate of 71.4%, and radiofrequency perforation in 3 cases, with a success rate of 100%. In PS patients, success was achieved in all of the cases. Hospital death was 23.5% for the PAIVS group and 3.3% for the PS group, none related to the percutaneous procedure. In the midterm follow-up, the reintervention rate due to restenosis was 21.4% in the PAIVS group and 10% in the PS group. CONCLUSIONS: Pulmonary valvuloplasty in PS or PAIVS has acceptable clinical and hemodynamic results, as long as favorable anatomic characteristics are observed and patent pulmonary flow is maintained until the procedure. Morbidity and mortality of patients with critical PS are lower than patients with PAIVS.


Asunto(s)
Humanos , Recién Nacido , Atresia Pulmonar/complicaciones , Cateterismo/métodos , Cateterismo , Estenosis de la Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/complicaciones , Ecocardiografía/métodos , Ecocardiografía , Recién Nacido
20.
Prenat Diagn ; 31(12): 1176-80, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22025282

RESUMEN

OBJECTIVE: To test the hypothesis that the aortic isthmus flow index (IFI) is lower in fetuses of diabetic mothers than in fetuses of nondiabetic mothers. STUDY DESIGN: We performed a cross-sectional observational study to assess the IFI in fetuses, with (n = 13) and without (n = 37) myocardial hypertrophy, of mothers with diabetes mellitus and in fetuses of nondiabetic mothers (n = 23). Analysis of variance and Tukey test were used to assess differences among the groups. RESULTS: There were no differences in maternal or gestational age among the groups. In fetuses of diabetic mothers, the mean IFI in fetuses with myocardial hypertrophy was 1.19 ± 0.06, and in fetuses without it was 1.18 ± 0.09. The mean IFI in fetuses of nondiabetic mothers was 1.32 ± 0.07 (P < 0.001). CONCLUSIONS: The IFI in fetuses of diabetic mothers is lower than in fetuses of nondiabetic mothers, possibly as a result of a decreased left ventricular compliance.


Asunto(s)
Aorta/fisiología , Diabetes Gestacional/fisiopatología , Embarazo en Diabéticas/fisiopatología , Flujo Sanguíneo Regional , Adulto , Cardiomegalia/fisiopatología , Estudios Transversales , Femenino , Enfermedades Fetales/fisiopatología , Humanos , Embarazo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...