Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
J Clin Med ; 12(12)2023 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-37373721

RESUMEN

BACKGROUND: Implantation of a permanent pacemaker and atrioventricular (AV) node ablation (pace-and-ablate) is an established approach for rate and symptom control in elderly patients with symptomatic atrial fibrillation (AF). Left bundle branch area pacing (LBBAP) is a physiological pacing strategy that might overcome right ventricular pacing-induced dyssynchrony. In this study, the feasibility and safety of performing LBBAP and AV node ablation in a single procedure in the elderly was investigated. METHODS: Consecutive patients with symptomatic AF referred for pace-and-ablate underwent the treatment in a single procedure. Data on procedure-related complications and lead stability were collected at regular follow-up at one day, ten days and six weeks after the procedure and continued every six months thereafter. RESULTS: 25 patients (mean age 79.2 ± 4.2 years) were included and underwent successful LBBAP. In 22 (88%) patients, AV node ablation and LBBAP were performed in the same procedure. AV node ablation was postponed in two patients due to lead-stability concerns and in one patient on their own request. No complications related to the single-procedure approach were observed with no lead-stability issues at follow-up. CONCLUSIONS: LBBAP combined with AV node ablation in a single procedure is feasible and safe in elderly patients with symptomatic AF.

3.
Front Cardiovasc Med ; 9: 879139, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35879962

RESUMEN

Introduction: Continuous progress in atrial fibrillation (AF) ablation techniques has led to an increasing number of procedures with improved outcome. However, about 30-50% of patients still experience recurrences within 1 year after their ablation. Comprehensive translational research approaches integrated in clinical care pathways may improve our understanding of the complex pathophysiology of AF and improve patient selection for AF ablation. Objectives: Within the "IntenSive mOlecular and eLectropathological chAracterization of patienTs undergoIng atrial fibrillatiOn ablatioN" (ISOLATION) study, we aim to identify predictors of successful AF ablation in the following domains: (1) clinical factors, (2) AF patterns, (3) anatomical characteristics, (4) electrophysiological characteristics, (5) circulating biomarkers, and (6) genetic background. Herein, the design of the ISOLATION study and the integration of all study procedures into a standardized pathway for patients undergoing AF ablation are described. Methods: ISOLATION (NCT04342312) is a two-center prospective cohort study including 650 patients undergoing AF ablation. Clinical characteristics and routine clinical test results will be collected, as well as results from the following additional diagnostics: determination of body composition, pre-procedural rhythm monitoring, extended surface electrocardiogram, biomarker testing, genetic analysis, and questionnaires. A multimodality model including a combination of established predictors and novel techniques will be developed to predict ablation success. Discussion: In this study, several domains will be examined to identify predictors of successful AF ablation. The results may be used to improve patient selection for invasive AF management and to tailor treatment decisions to individual patients.

4.
Res Cardiovasc Med ; 4(1): e25592, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25785255

RESUMEN

INTRODUCTION: Pulmonary vein (PV) isolation is considered as a key to atrial fibrillation (AF) treatment. Cryoballoon ablation is an effective therapy for PV isolation for AF with minimal side effects and was approved by the US Food and Drug Administration (FDA) several years ago. Successful isolation of PVs during cryoablation depends on the balloon temperature and helps in early identification of noneffective cryoballoon applications. A lower balloon temperature has been associated with long-term success in isolation of PVs. CASE PRESENTATION: At the start of the procedure, the cryoconsole displayed "low refrigerant level". After a few cycles of successful cryoballoon applications, for a fresh application for a new PV, the optimal temperature was not obtained in spite of obtaining good grade of occlusion and ostial positioning for right inferior pulmonary vein (RIPV). Later, immediately after changing the refrigerant cylinder, suitable temperature was obtained. We faced this situation thrice in a span of eight months. CONCLUSION: Low refrigerant level may cause nonoptimal temperature during cryoablation, which can be resolved by premature change of a gas cylinder.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...