Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Biosaf ; 27(1): 15-22, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36032319

RESUMEN

Aim: This study aimed to validate the efficacy of hydrogen peroxide vapor (HPV) decontamination technology set up in a biosafety level 3 (BSL-3) laboratory on surrogates and hazard group 3 (HG3) agents. Methods and Results: The HPV decontamination system (Bioquell) was assessed with both qualitative and quantitative methods on (1) spore surrogates (Geobacillus stearothermophilus, Bacillus atrophaeus, and Bacillus thuringiensis) in the BSL-3 laboratory and in the material airlock and on (2) HG3 agents (Bacillus anthracis; SARS-CoV-2, Venezuelan equine encephalitis virus [VEE], and Vaccinia virus) in the BSL-3 laboratory. Other HG3 bacteria likely to be handled in the BSL-3 laboratory (Yersinia pestis, Burkholderia mallei, Brucella melitensis, and Francisella tularensis) were excluded from the HPV decontamination assays as preliminary viability tests demonstrated the total inactivation of these agents after 48 h drying on different materials. Conclusions: The efficacy of HPV decontamination was validated with a reduction in viability of 5-7 log10 for the spores (surrogates and B. anthracis), and for the enveloped RNA viruses. Vaccinia showed a higher resistance to the decontamination process, being dependent on the biological indicator location in the BSL-3 laboratory.

2.
Microbiol Spectr ; 9(1): e0033321, 2021 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-34287031

RESUMEN

We studied the stability of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) under different simulated outdoor conditions by changing the temperature (20°C and 35°C), the illuminance (darkness, 10 klx, and 56 klx), and/or the cleanness of the surfaces at 50% relative humidity (RH). In darkness, the loss of viability of the virus on stainless steel is temperature dependent, but this is hidden by the effect of the sunlight from the first minutes of exposure. The virus shows a sensitivity to sunlight proportional to the illuminance intensity of the sunlight. The presence of interfering substances has a moderate effect on virus viability even with an elevated illuminance. Thus, SARS-CoV-2 is rapidly inactivated by simulated sunlight in the presence or absence of high levels of interfering substances at 20°C or 35°C and 50% relative humidity. IMPORTANCE Clinical matrix contains high levels of interfering substances. This study is the first to reveal that the presence of high levels of interfering substances had little impact on the persistence of SARS-CoV-2 on stainless steel following exposure to simulated sunlight. Thus, SARS-CoV-2 should be rapidly inactivated in outdoor environments in the presence or absence of interfering substances. Our results indicate that transmission of SARS-CoV-2 is unlikely to occur through outdoor surfaces, dependent on illuminance intensity. Moreover, most studies are interested in lineage S of SARS-CoV-2. In our experiments, we studied the stability of L-type strains, which comprise the majority of strains isolated from worldwide patients. Nevertheless, the effect of sunlight seems to be similar regardless of the strain studied, suggesting that the greater spread of certain variants is not correlated with better survival in outdoor conditions.


Asunto(s)
Viabilidad Microbiana/efectos de la radiación , SARS-CoV-2/efectos de la radiación , Luz Solar , Inactivación de Virus/efectos de la radiación , COVID-19/prevención & control , COVID-19/transmisión , Descontaminación , Humanos , Cinética , SARS-CoV-2/crecimiento & desarrollo , Propiedades de Superficie , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA