Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Chem Biomed Imaging ; 2(3): 213-221, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38551010

RESUMEN

High-resolution spatial and temporal analysis and 3D visualization of time-dependent processes, such as human dental enamel acid demineralization, often present a challenging task. Overcoming this challenge often requires the development of special methods. Dental caries remains one of the most important oral diseases that involves the demineralization of hard dental tissues as a consequence of acid production by oral bacteria. Enamel has a hierarchically organized architecture that extends down to the nanostructural level and requires high resolution to study its evolution in detail. Enamel demineralization is a dynamic process that is best investigated with the help of in situ experiments. In previous studies, synchrotron tomography was applied to study the 3D enamel structure at certain time points (time-lapse tomography). Here, another distinct approach to time-evolving tomography studies is presented, whereby the sample image is reconstructed as it undergoes continuous rotation over a virtually unlimited angular range. The resulting (single) data set contains the data for multiple (potentially overlapping) intermediate tomograms that can be extracted and analyzed as desired using time-stepping selection of data subsets from the continuous fly-scan recording. One of the advantages of this approach is that it reduces the amount of time required to collect an equivalent number of single tomograms. Another advantage is that the nominal time step between successive reconstructions can be significantly reduced. We applied this approach to the study of acidic enamel demineralization and observed the progression of demineralization over time steps significantly smaller than the total acquisition time of a single tomogram, with a voxel size smaller than 0.5 µm. It is expected that the approach presented in this paper can be useful for high-resolution studies of other dynamic processes and for assessing small structural modifications in evolving hierarchical materials.

2.
ACS Appl Mater Interfaces ; 15(31): 37259-37273, 2023 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-37524079

RESUMEN

Caries, a major global disease associated with dental enamel demineralization, remains insufficiently understood to devise effective prevention or minimally invasive treatment. Understanding the ultrastructural changes in enamel is hampered by a lack of nanoscale characterization of the chemical spatial distributions within the dental tissue. This leads to the requirement to develop techniques based on various characterization methods. The purpose of the present study is to demonstrate the strength of analytic methods using a correlative technique on a single sample of human dental enamel as a specific case study to test the accuracy of techniques to compare regions in enamel. The science of the different techniques is integrated to genuinely study the enamel. The hierarchical structures within carious tissue were mapped using the combination of focused ion beam scanning electron microscopy with synchrotron X-ray tomography. The chemical changes were studied using scanning X-ray fluorescence (XRF) and X-ray wide-angle and small-angle scattering using a beam size below 80 nm for ångström and nanometer length scales. The analysis of XRF intensity gradients revealed subtle variations of Ca intensity in carious samples in comparison with those of normal mature enamel. In addition, the pathways for enamel rod demineralization were studied using X-ray ptychography. The results show the chemical and structural modification in carious enamel with differing locations. These results reinforce the need for multi-modal approaches to nanoscale analysis in complex hierarchically structured materials to interpret the changes of materials. The approach establishes a meticulous correlative characterization platform for the analysis of biomineralized tissues at the nanoscale, which adds confidence in the interpretation of the results and time-saving imaging techniques. The protocol demonstrated here using the dental tissue sample can be applied to other samples for statistical study and the investigation of nanoscale structural changes. The information gathered from the combination of methods could not be obtained with traditional individual techniques.


Asunto(s)
Caries Dental , Esmalte Dental , Humanos , Microscopía Electrónica de Rastreo , Dispersión del Ángulo Pequeño , Rayos X , Microscopía Confocal , Esmalte Dental/diagnóstico por imagen , Caries Dental/diagnóstico por imagen
3.
Dent J (Basel) ; 11(5)2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37232781

RESUMEN

Caries is a chronic disease that causes the alteration of the structure of dental tissues by acid dissolution (in enamel, dentine and cementum) and proteolytic degradation (dentine and cementum) and generates an important cost of care. There is a need to visualise and characterise the acid dissolution process on enamel due to its hierarchical structure leading to complex structural modifications. The process starts at the enamel surface and progresses into depth, which necessitates the study of the internal enamel structure. Artificial demineralisation is usually employed to simulate the process experimentally. In the present study, the demineralisation of human enamel was studied using surface analysis carried out with atomic force microscopy as well as 3D internal analysis using synchrotron X-ray tomography during acid exposure with repeated scans to generate a time-lapse visualisation sequence. Two-dimensional analysis from projections and virtual slices and 3D analysis of the enamel mass provided details of tissue changes at the level of the rods and inter-rod substance. In addition to the visualisation of structural modifications, the rate of dissolution was determined, which demonstrated the feasibility and usefulness of these techniques. The temporal analysis of enamel demineralisation is not limited to dissolution and can be applied to other experimental conditions for the analysis of treated enamel or remineralisation.

4.
Sci Rep ; 12(1): 12136, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35840749

RESUMEN

In this work, the application of a time resolved multi-contrast beam tracking technique to the investigation of the melting and solidification process in metals is presented. The use of such a technique allows retrieval of three contrast channels, transmission, refraction and dark-field, with millisecond time resolution. We investigated different melting conditions to characterize, at a proof-of-concept level, the features visible in each of the contrast channels. We found that the phase contrast channel provides a superior visibility of the density variations, allowing the liquid metal pool to be clearly distinguished. Refraction and dark-field were found to highlight surface roughness formed during solidification. This work demonstrates that the availability of the additional contrast channels provided by multi-contrast X-ray imaging delivers additional information, also when imaging high atomic number specimens with a significant absorption.

5.
Langmuir ; 38(4): 1638-1650, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35050635

RESUMEN

Oleofoams are a novel, versatile, and biocompatible soft material that finds application in drug, cosmetic or nutraceuticals delivery. However, due to their temperature-sensitive and opaque nature, the characterization of oleofoams' microstructure is challenging. Here, synchrotron X-ray microcomputed tomography and radiography are applied to study the microstructure of a triglyceride-based oleofoam. These techniques enable non-destructive, quantitative, 3D measurements of native samples to determine the thermodynamic and kinetic behavior of oleofoams at different stages of their life cycle. During processing, a constant bubble size distribution is reached after few minutes of shearing, while the number of bubbles incorporated keeps increasing until saturation of the continuous phase. Low amounts of solid triglycerides in oleofoams allow faster aeration and a more homogeneous microstructure but lower thermodynamic stability, with bubble disproportionation and shape relaxation over time. Radiography shows that heating causes Ostwald ripening and coalescence of bubbles, with an increase of their diameter and sphericity.


Asunto(s)
Sincrotrones , Temperatura , Microtomografía por Rayos X/métodos
6.
J Synchrotron Radiat ; 29(Pt 1): 138-147, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985431

RESUMEN

Full-field transmission X-ray microscopy (TXM) is a very potent high-resolution X-ray imaging technique. However, it is challenging to achieve fast acquisitions because of the limited efficiency of the optics. Using a broader energy bandwidth, for example using a multilayer monochromator, directly increases the flux in the experiment. The advantage of more counts needs to be weighed against a deterioration in achievable resolution because focusing optics show chromatic aberrations. This study presents theoretical considerations of how much the resolution is affected by an increase in bandwidth as well as measurements at different energy bandwidths (ΔE/E = 0.013%, 0.27%, 0.63%) and the impact on achievable resolution. It is shown that using a multilayer monochromator instead of a classical silicon double-crystal monochromator can increase the flux by an order of magnitude with only a limited effect on the resolution.

7.
Phys Rev Lett ; 127(21): 215503, 2021 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-34860108

RESUMEN

We present a dynamic implementation of the beam-tracking x-ray imaging method providing absorption, phase, and ultrasmall angle scattering signals with microscopic resolution and high frame rate. We demonstrate the method's ability to capture dynamic processes with 22-ms time resolution by investigating the melting of metals in laser additive manufacturing, which has so far been limited to single-modality synchrotron radiography. The simultaneous availability of three contrast channels enables earlier segmentation of droplets, tracking of powder dynamic, and estimation of unfused powder amounts, demonstrating that the method can provide additional information on melting processes.

8.
ACS Appl Mater Interfaces ; 12(30): 34254-34264, 2020 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-32567300

RESUMEN

Capillary-driven ink infiltration through a porous powder bed in three-dimensional (3D) binder jet printing (inkjet printing onto a powder bed) controls the printing resolution and as-printed "green" strength of the resulting object. However, a full understanding of the factors controlling the kinetics of the infiltration remains incomplete. Here, high-resolution in situ synchrotron radiography provides time-resolved imaging of the penetration of an aqueous solution of eythylene glycol through a porous alumina powder bed, used as a model system. A static drop-on-demand inkjet printer was used to dispense liquid droplets onto a powder surface. The subsequent migration of the liquid front and its interactions with powder particles were tracked using fast synchrotron X-radiography in the Diamond Synchrotron, with phase-contrast imaging at a frame rate of 500 Hz. Image processing and analysis reveal that both the time-dependent increment in the wetting area and the propagation of the "interface leading edge" exhibit heterogeneous behavior in both temporal and spatial domains. However, mean infiltration kinetics are shown to be consistent with existing infiltration models based on the Washburn equation modified to account for the spreading of the liquid drop on the powder surface and using a modified term for the bed porosity.

9.
J Vis Exp ; (116)2016 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-27768076

RESUMEN

A procedure for a technique to measure the transverse coherence of synchrotron radiation X-ray sources using a single phase grating interferometer is reported. The measurements were demonstrated at the 1-BM bending magnet beamline of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). By using a 2-D checkerboard π/2 phase-shift grating, transverse coherence lengths were obtained along the vertical and horizontal directions as well as along the 45° and 135° directions to the horizontal direction. Following the technical details specified in this paper, interferograms were measured at different positions downstream of the phase grating along the beam propagation direction. Visibility values of each interferogram were extracted from analyzing harmonic peaks in its Fourier Transformed image. Consequently, the coherence length along each direction can be extracted from the evolution of visibility as a function of the grating-to-detector distance. The simultaneous measurement of coherence lengths in four directions helped identify the elliptical shape of the coherence area of the Gaussian-shaped X-ray source. The reported technique for multiple-direction coherence characterization is important for selecting the appropriate sample size and orientation as well as for correcting the partial coherence effects in coherence scattering experiments. This technique can also be applied for assessing coherence preserving capabilities of X-ray optics.


Asunto(s)
Sincrotrones , Rayos X , Óptica y Fotónica , Fotones
10.
Rev Sci Instrum ; 87(5): 052004, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27250384

RESUMEN

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. The design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

11.
J Phys Chem B ; 120(9): 2612-24, 2016 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-26846254

RESUMEN

Underwriters Laboratories 94 test bars have been imaged with X-ray K-edge tomography between 12 and 32 keV to assess the bromine and antimony concentration gradient across char layers of partially burnt samples. Phase contrast tomography on partially burnt samples showed gas bubbles and dark-field scattering ascribed to residual blend inhomogeneity. In addition, single-shot grating interferometry was used to record X-ray movies of test samples during heating (IR and flame) intended to mimic the UL 94 plastics flammability test. The UL 94 test bars were formulated with varying concentrations of a brominated flame retardant, Saytex 8010, and a synergist, Sb2O3, blended into high-impact polystyrene (HIPS). Depending on the sample composition, samples will pass or fail the UL 94 plastics flammability test. Tomography and interferometry imaging show differences that correlate with UL 94 performance. Key features such as char layer, gas bubble formation, microcracks, and dissolution of the flame retardant in the char layer regions are used in understanding the efficiency of the flame retardant and synergist. The samples that pass the UL 94 test have a thick, highly visible char layer as well as an interior rich in gas bubbles. Growth of gas bubbles from flame-retardant thermal decomposition is noted in the X-ray phase contrast movies. Also noteworthy is an absence of bubbles near the burning surface of the polymer; dark-field images after burning suggest a microcrack structure between interior bubbles and the surface. The accepted mechanism for flame retardant activity includes free radical quenching in the flame by bromine and antimony species. The imaging supports this as well as provides a fast inspection of other parameters, such as viscosity and surface tension.

12.
Phys Med Biol ; 60(8): 3065-80, 2015 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-25802946

RESUMEN

X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve the same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.


Asunto(s)
Algoritmos , Tejido Conectivo/diagnóstico por imagen , Animales , Tomografía Computarizada por Rayos X/métodos , Pez Cebra
13.
Opt Express ; 22(12): 14041-53, 2014 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-24977503

RESUMEN

Transverse coherence of the x-ray beam from a bending magnet source was studied along multiple directions using a 2-D π/2 phase grating by measuring interferogram visibilities at different distances behind the grating. These measurements suggest that the preferred measuring orientation of a 2-D checkerboard grating is along the diagonal directions of the square blocks, where the interferograms have higher visibility and are not sensitive to the deviation of the duty cycle of the grating period. These observations are verified by thorough wavefront propagation simulations. The accuracy of the measured coherence values was also validated by the simulation and analytical results obtained from the source parameters. In addition, capability of the technique in probing spatially resolved local transverse coherence is demonstrated.

14.
J Synchrotron Radiat ; 21(Pt 4): 662-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24971959

RESUMEN

The micro-focusing performance for hard X-rays of a fixed-geometry elliptical Kirkpatrick-Baez (K-B) mirrors assembly fabricated, tested and finally implemented at the micro-probe beamline 8-BM of the Advanced Photon Source is reported. Testing of the K-B mirror system was performed at the optics and detector test beamline 1-BM. K-B mirrors of length 80 mm and 60 mm were fabricated by profile coating with Pt metal to produce focal lengths of 250 mm and 155 mm for 3 mrad incident angle. For the critical angle of Pt, a broad bandwidth of energies up to 20 keV applies. The classical K-B sequential mirror geometry was used, and mirrors were mounted on micro-translation stages. The beam intensity profiles were measured by differentiating the curves of intensity data measured using a wire-scanning method. A beam size of 1.3 µm (V) and 1.2 µm (H) was measured with monochromatic X-rays of 18 keV at 1-BM. After installation at 8-BM the measured focus met the design requirements. In this paper the fabrication and metrology of the K-B mirrors are reported, as well as the focusing performances of the full mirrors-plus-mount set-up at both beamlines.

15.
Rev Sci Instrum ; 85(1): 013704, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24517772

RESUMEN

Grating-based X-ray and neutron interferometry tomography using phase-stepping methods generates large data sets. An improved algorithm is presented for solving for the parameters to calculate transmissions, differential phase contrast, and dark-field images. The method takes advantage of the vectorization inherent in high-level languages such as Mathematica and MATLAB and can solve a 16 × 1k × 1k data set in less than a second. In addition, the algorithm can function with partial data sets. This is demonstrated with processing of a 16-step grating data set with partial use of the original data chosen without any restriction. Also, we have calculated the reduced chi-square for the fit and notice the effect of grating support structural elements upon the differential phase contrast image and have explored expanded basis set representations to mitigate the impact.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Análisis de Fourier , Interferometría , Luz
16.
Opt Express ; 18(7): 7253-62, 2010 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-20389746

RESUMEN

We present a reflection based coherent diffraction imaging method which can be used to reconstruct a non periodic surface image from a diffraction amplitude measured in reflection geometry. Using a He-Ne laser, we demonstrated that a surface image can be reconstructed solely from the reflected intensity from a surface without relying on any prior knowledge of the sample object or the object support. The reconstructed phase image of the exit wave is particularly interesting since it can be used to obtain quantitative information of the surface depth profile or the phase change during the reflection process. We believe that this work will broaden the application areas of coherent diffraction imaging techniques using light sources with limited penetration depth.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Óptica y Fotónica , Algoritmos , Simulación por Computador , Diseño de Equipo , Oro/química , Imagenología Tridimensional , Rayos Láser , Silicio/química , Propiedades de Superficie , Rayos Ultravioleta , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...