Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Dental Press J Orthod ; 20(2): 61-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25992989

RESUMEN

OBJECTIVE: To assess enamel surface under scanning electron microscopy (SEM) after resin removal and enamel polishing procedures following brackets debonding, as well as compare the time required for these procedures. METHODS: A total of 180 deciduous bovine incisors were used. The enamel surface of each tooth was prepared and brackets were bonded with light cured Transbond XT composite resin. Brackets were removed in a testing machine. The samples were randomized and equally distributed into nine groups according to the resin removal and polishing technique: Group 1, 30-blade tungsten carbide bur in high speed; Group 2, 30-blade tungsten carbide bur in high speed followed by a sequence of 4 Sof-lex polishing discs (3M); Group 3, 30-blade tungsten carbide bur in high speed followed by Enhance tips (Dentsply). All groups were subdivided into (a) unpolished; (b) polished with aluminum oxide paste; and (c) polished with water slurry of fine pumice. Subsequently, the enamel surface was assessed and statistical analysis was carried out. RESULTS: There were statistically significant differences in enamel roughness and removal time among all groups. Groups 3a, 3b and 3c appeared to be the most efficient methods of removing resin with low damages to enamel. Groups 2a, 2b and 2c were the most time consuming procedures, and Group 2a caused more damages to enamel. CONCLUSION: The suggested protocol for resin removal is the 30-blade tungsten carbide bur in high speed followed by Enhance tips and polishing with aluminum oxide paste. This procedure seems to produce less damages and is less time consuming.


Asunto(s)
Desconsolidación Dental/métodos , Esmalte Dental/ultraestructura , Profilaxis Dental/métodos , Soportes Ortodóncicos , Cementos de Resina/química , Grabado Ácido Dental/métodos , Óxido de Aluminio/química , Animales , Bovinos , Recubrimiento Dental Adhesivo/métodos , Desconsolidación Dental/instrumentación , Equipo Dental de Alta Velocidad , Profilaxis Dental/instrumentación , Microscopía Electrónica de Rastreo , Distribución Aleatoria , Silicatos/química , Propiedades de Superficie , Factores de Tiempo , Compuestos de Tungsteno/química
2.
Dental press j. orthod. (Impr.) ; 20(2): 61-67, Mar-Apr/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-745853

RESUMEN

OBJECTIVE: To assess enamel surface under scanning electron microscopy (SEM) after resin removal and enamel polishing procedures following brackets debonding, as well as compare the time required for these procedures. METHODS: A total of 180 deciduous bovine incisors were used. The enamel surface of each tooth was prepared and brackets were bonded with light cured Transbond XT composite resin. Brackets were removed in a testing machine. The samples were randomized and equally distributed into nine groups according to the resin removal and polishing technique: Group 1, 30-blade tungsten carbide bur in high speed; Group 2, 30-blade tungsten carbide bur in high speed followed by a sequence of 4 Sof-lex polishing discs (3M); Group 3, 30-blade tungsten carbide bur in high speed followed by Enhance tips (Dentsply). All groups were subdivided into (a) unpolished; (b) polished with aluminum oxide paste; and (c) polished with water slurry of fine pumice. Subsequently, the enamel surface was assessed and statistical analysis was carried out. RESULTS: There were statistically significant differences in enamel roughness and removal time among all groups. Groups 3a, 3b and 3c appeared to be the most efficient methods of removing resin with low damages to enamel. Groups 2a, 2b and 2c were the most time consuming procedures, and Group 2a caused more damages to enamel. CONCLUSION: The suggested protocol for resin removal is the 30-blade tungsten carbide bur in high speed followed by Enhance tips and polishing with aluminum oxide paste. This procedure seems to produce less damages and is less time consuming. .


OBJETIVO: avaliar a superfície do esmalte, por meio de microscopia eletrônica de varredura, após descolagem de braquetes e o polimento do esmalte, com diferentes técnicas de remoção de resina, bem como comparar o tempo necessário para a realização do procedimento. MÉTODOS: foram utilizados 180 dentes bovinos decíduos. A superfície do esmalte dos dentes foi preparada e realizada a colagem dos braquetes com resina Transbond XT. Os braquetes foram removidos em máquina de ensaio mecânico. Foram formados, aleatoriamente, nove grupos, de acordo com o tipo de remoção da resina e de polimento, sendo: Grupo 1, broca de tungstênio de 30 lâminas em alta rotação; Grupo 2, broca de tungstênio de 30 lâminas em alta rotação e sequência de quatro discos Soflex (3M); Grupo 3, broca de tungstênio de 30 lâminas em alta rotação e pontas de acabamento Enhance (Dentsply). Todos os grupos foram subdividido em (a) sem polimento, (b) polimento com pasta de óxido de alumínio e (c) polimento com pedra-pomes. As superfícies foram avaliadas e foi realizada análise estatística. RESULTADOS: houve diferença estatística entre os grupos em relação à rugosidade de superfície e ao tempo de remoção. Os grupos 3a, 3b e 3c demonstraram ser os métodos mais eficientes de remoção da resina, promovendo pouco dano à superfície do esmalte. Os grupos 2a, 2b e 2c consumiram maior tempo de procedimento, e o grupo 2a causou maior dano ao esmalte. CONCLUSÃO: sugere-se como protocolo de remoção o uso de broca de tungstênio de 30 lâminas para remoção do maior volume da resina, pontas de acabamento Enhance e polimento com a pasta de óxido de alumínio, por produzirem menor dano. .


Asunto(s)
Animales , Bovinos , Desconsolidación Dental/métodos , Esmalte Dental/ultraestructura , Profilaxis Dental/métodos , Soportes Ortodóncicos , Cementos de Resina/química , Grabado Ácido Dental/métodos , Óxido de Aluminio/química , Equipo Dental de Alta Velocidad , Recubrimiento Dental Adhesivo/métodos , Desconsolidación Dental/instrumentación , Profilaxis Dental/instrumentación , Microscopía Electrónica de Rastreo , Distribución Aleatoria , Propiedades de Superficie , Silicatos/química , Factores de Tiempo , Compuestos de Tungsteno/química
3.
Dental Press J Orthod ; 18(2): 69-75, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23916434

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. METHODS: Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in) were divided into three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless steel, or SS); STD/MO group = Slim Morelli (SS); and Ni-Free/MO group = Slim Morelli (Ni-Free). The stainless steel wires (0.019 x 0.025-in) were divided into two groups: MO group = Morelli; and 3M group = 3M/Unitek. The bracket and wire measurements were done by two methods: (a) Surface Electron Microscopy (SEM), and (b) Profile Projection. The surface analysis was done qualitatively, based on SEM images and/or by a rugosimeter. The quantitative results were analyzed by ANOVA with Tukey's test (p < 0.05) and Student's t test. RESULTS: A significant difference in the dimensions of slots was observed, and the NiFree/MO group showed the greatest changes when compared to the other groups. The analysis of surface topography of the brackets indicated greater homogeneity of the metallic matrix for DYN/3M and STD/MO groups. As for the dimensions of the wires, groups showed statistically different mean heights. CONCLUSIONS: It was concluded that wires and brackets slots can present altered dimensions, which might directly and unintentionally affect the planned tooth movement.


Asunto(s)
Diseño de Aparato Ortodóncico , Soportes Ortodóncicos , Alambres para Ortodoncia , Aleaciones Dentales , Fricción , Microscopía Electrónica de Rastreo , Acero Inoxidable , Propiedades de Superficie
4.
Dental press j. orthod. (Impr.) ; 18(2): 69-75, Mar.-Apr. 2013. ilus, tab
Artículo en Inglés | LILACS | ID: lil-683186

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. METHODS: Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in) were divided in three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless steel, or SS); STD/MO group = Slim Morelli (SS); and Ni-Free/MO group = Slim Morelli (Ni-Free). The stainless steel wires (0.019 x 0.025in) were divided into two groups: MO group = Morelli; and 3M group = 3M/Unitek. The bracket and wire measurements were done by two methods: (a) Surface Electron Microscopy (SEM), and (b) Profile projection. The surface analysis was done qualitatively, based on SEM images and/or by a rugosimeter. The quantitative results were analyzed by ANOVA with Tukey's test (p < 0.05) and Student's t test. RESULTS: A significant difference in the dimensions of slots was observed, and the NiFree/MO group showed the greatest changes when compared to the other groups. The analysis of surface topography of the brackets indicated greater homogeneity of the metallic matrix for DYN/3M and STD/MO groups. As for the dimensions of the wires, groups showed statistically different mean heights. CONCLUSIONS: It was concluded that wires and brackets slots can present altered dimensions, which might directly and unintentionally affect the planned tooth movement.


OBJETIVO: o objetivo desse estudo é avaliar as dimensões e as características superficiais de fios retangulares e slots de braquetes de diferentes marcas comerciais. MÉTODOS: trinta braquetes metálicos (0,022" x 0,028" e 0,022" x 0,030") foram divididos em três grupos: Grupo DYN/3M = Dyna-Lock, 3M/Unitek, aço inoxidável (AI); Grupo STD/MO = Slim Morelli (AI); e Grupo NiFree/MO = Slim Morelli (Ni-Free). Já os fios retangulares (0,019" x 0,025"), de aço inoxidável, foram divididos em 2 grupos: Grupo MO = Morelli; Grupo 3M = 3M/Unitek. As mensurações dos slots dos braquetes e dos fios foram realizadas por dois métodos: (a) microscopia eletrônica de varredura (MEV), e (b) projeção de perfil. A análise da topografia superficial foi realizada qualitativamente, baseada em imagens microscópicas (MEV) e/ou por meio de um rugosímetro. Os resultados quantitativos foram submetidos à análise de variância (ANOVA) com o teste de Tukey (p < 0,05) ou o teste t de Student. RESULTADOS: observou-se diferença significativa entre as dimensões dos slots dos braquetes, sendo que o Grupo NiFree/MO apresentou a maior alteração quando comparado aos demais Grupos. A análise da topografia superficial dos braquetes indicou maior homogeneidade da matriz metálica nos Grupos DYN/3M e STD/MO. Quanto às dimensões dos fios, os grupos tiveram alturas médias estatisticamente diferentes entre si. CONCLUSÃO: concluiu-se que a conformação dos fios e dos slots dos braquetes pode apresentar alterações dimensionais, o que afetará direta e indesejavelmente o movimento dentário planejado.


Asunto(s)
Diseño de Aparato Ortodóncico , Soportes Ortodóncicos , Alambres para Ortodoncia , Aleaciones Dentales , Fricción , Microscopía Electrónica de Rastreo , Acero Inoxidable , Propiedades de Superficie
5.
Dental press j. orthod. (Impr.) ; 16(6): 93-99, nov.-dez. 2011. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-614665

RESUMEN

INTRODUÇÃO: os materiais elastoméricos são considerados importantes fontes de força para a movimentação ortodôntica. OBJETIVO: avaliar a liberação de tensões de quatro marcas comerciais de elásticos ortodônticos em cadeia (Morelli, Ormco, TP e Unitek), em função do tempo, quando mantidas tensionadas por uma força inicial de 150g e imersas em saliva artificial a 37ºC. MÉTODOS: os elásticos em cadeia foram tensionados entre pinos de aço, fixados em uma placa de resina acrílica à distância de 15mm (Morelli e TP) e de 16mm (Unitek e Ormco), ambas medidas correspondendo a uma força de 150g. A leitura da quantidade de tensão liberada pelos elásticos foi realizada com um dinamômetro nos intervalos 30 minutos, 7, 14 e 21 dias. Os dados obtidos foram submetidos à análise de variância (ANOVA) (p<0,05) e ao teste de Comparações Múltiplas de Tukey. RESULTADOS: após 30 minutos de teste, verificou-se redução entre 19 por cento e 26,67 por cento na quantidade de tensão liberada pelos elásticos; e entre 36,67 por cento e 57 por cento após 21 dias de estiramento constante. CONCLUSÕES: os elásticos em cadeia que apresentaram comportamento mais estável foram os da marca TP, pois relataram menor perda de potencial elástico nos intervalos de tempo testados. Os da marca Unitek demonstraram maior redução de tensão liberada. As marcas Ormco e Morelli obtiveram resultados semelhantes entre si.


INTRODUCTION: Elastomeric materials are considered important sources of orthodontic forces. OBJECTIVE: To assess force degradation over time of four commercially available orthodontic elastomeric chains (Morelli, Ormco, TP and Unitek). METHODS: The synthetic elastics were submerged in 37 ºC synthetic saliva and stretched by a force of 150 g (15 mm - Morelli and TP; 16mm - Unitek and Ormco). With a dynamometer, the delivered force was evaluated at different intervals: 30 minutes, 7 days, 14 days and 21 days. The results were subjected to ANOVA and Tukey's test. RESULTS: There was a force decay between 19 percent to 26.67 percent after 30 minutes, and 36.67 percent to 57 percent after 21 days of activation. CONCLUSIONS: TP elastomeric chains exhibited the smallest percentage of force decay, with greater stability at all time intervals tested. Meanwhile, the Unitek chains displayed the highest percentage of force degradation, and no statically significant difference was found in force decay between Ormco and Morelli elastomeric chains during the study period.


Asunto(s)
Materiales Biomédicos y Dentales , Elasticidad , Elastómeros , Antisépticos Bucales , Materiales Dentales/análisis , Polímeros , Saliva Artificial , Ortodoncia
7.
Eur J Orthod ; 33(1): 55-9, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20558589

RESUMEN

The purpose of this study was to assess the influence of two light units, a light-emitting diode (LED) and a plasma arc light (PAC), on the shear bond strength (SBS) of brackets bonded to enamel. Ninety bovine teeth were divided into six groups, according to the light-curing unit and exposure times used. In the LED (Ortholux; 3M-Unitek) group, the specimens were light cured for 5, 10, and 15 seconds. In the PAC (Apollo 95E; DenMed Technologies) group, the specimens were light cured for 3, 6, and 9 seconds. The brackets were bonded with Transbond XT (3M-Unitek), stored in distilled water at 37 °C for 24 hours and then submitted to SBS testing in a universal testing machine. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the teeth. According to analysis of variance and Tukey multiple comparisons test, the highest mean SBS was obtained with the LED at 15 seconds (16.68 MPa), which did not significantly differ from the LED 10 (14.76 MPa) or 5 (13.92 MPa) second groups (P > 0.05). The LED 10 and 5 second groups were not significantly different from the PAC 9 second group (12.66 MPa) or from the PAC 6 second group (9.96 MPa). The lowest mean SBS was obtained with the PAC 3 second group (8.29 MPa), which did not differ significantly from the PAC 6 second group. The method of light curing did not influence the ARI, with score 3 predominant. The LED at 5 seconds and the PAC at 3 seconds provided sufficient mean SBS to resist either orthodontic or masticatory forces.


Asunto(s)
Luces de Curación Dental/clasificación , Curación por Luz de Adhesivos Dentales/instrumentación , Soportes Ortodóncicos , Cementos de Resina/efectos de la radiación , Adhesividad , Animales , Bovinos , Esmalte Dental/ultraestructura , Análisis del Estrés Dental/instrumentación , Ensayo de Materiales , Cementos de Resina/química , Resistencia al Corte , Estrés Mecánico , Propiedades de Superficie , Temperatura , Factores de Tiempo , Agua/química
8.
Rev. odonto ciênc ; 26(2): 126-132, 2011. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-611658

RESUMEN

PURPOSE: To evaluate the effect of flexion and linear measures of the cranial base on the anteroposterior position of the jaws in skeletal Class III malocclusion compared with skeletal Class I. METHODS: One hundred-twenty lateral radiographs were divided in two groups: Group 1 - 60 radiographs of individuals with a Class I skeletal pattern; and Group 2 - 60 radiographs of individuals with a skeletal Class III pattern. The radiographs were of adult Caucasian individuals with no previous orthodontic treatment. Data were analyzed by using ANOVA. RESULTS: There were significant differences in the cranial base angle (NSBa) and anterior cranial base length (S-N) between the two groups. Group 2 had the lowest values for NSBa and S-N. The analysis of cranial base complementary angles (NSGn and BaSGn) revealed a significant statistical difference in NSGn: Group 2 had lower NSGn values, which indicates a more anterior position of the gnathion. Variations of the cranial base angle and the Y axis were inversely correlated with variations of SNA and SNB angles, and the differences were statistically significant for the two groups. CONCLUSION: This study supports previous findings that the cranial base flexion contributes to skeletal configuration in Class III skeletal patterns. Therefore, the cranial base should be evaluated for growth predictions and Class III diagnosis. The effect of the cranial base on the positioning of the jaws should be further assessed.


OBJETIVO: Avaliar o efeito da flexão a das medidas lineares da base do crânio na posição anteroposterior da maxila e da mandíbula na maloclusão de Classe III esquelética através da comparação com a Classe I esquelética. MÉTODOS: A amostra selecionada foi composta de 120 radiografias cefalométricas, em norma lateral, divididas em dois grupos: Grupo 1: 60 radiografias de indivíduos com padrão de Classe I esquelética; e Grupo 2: 60 radiografias de indivíduos com padrão de Classe III esquelética. As radiografias selecionadas foram de indivíduos adultos, Caucasianos e sem tratamento ortodôntico prévio. Os dados foram analisados por ANOVA. RESULTADOS: Houve diferença significativa no ângulo da base do crânio (NSBa) e no comprimento da base anterior do crânio (S-N) entre os dois grupos. O Grupo 2 obteve valores menores para NSBa e S-N. A análise dos ângulos complementares da base do crânio (NSGn and BaSGn) revelou uma diferença estatisticamente significativa no NSGn: O Grupo 2 obteve menores valores de NSG o que indica uma posição mais anterior do gnátio. Variações no ângulo da base do crânio e no eixo Y foram inversamente correlacionadas com variações nos ângulos SNA e SNB, e as diferenças foram estatisticamente significativas para os dois grupos. CONCLUSÃO: Este estudo concorda com estudos anteriores de que a flexão da base do crânio contribui para a configuração esquelética no padrão de Classe III esquelética. Logo, a base do crânio deve ser avaliada nas previsões de crescimento e no diagnóstico da Classe III. O estudo do efeito da base do crânio no posicionamento dos maxilares deve ser mais aprofundado.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Base del Cráneo , Cefalometría , Maloclusión Clase I de Angle , Maloclusión de Angle Clase III
9.
Rev. odonto ciênc ; 26(4): 321-325, 2011. tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-625016

RESUMEN

PURPOSE: To analyze, in vitro, the influence of a quartz-tungsten-halogen (QTH) and a plasma arc (PAC) on the degree of conversion and hardness of a composite resin, as well as the heat generated by the units. METHODS: Transbond XT disks were prepared and light-cured for 10, 20 and 30 seconds with a QTH (Curing Light XL 3000) or with a PAC (Apollo 95E) for 1, 2 and 3 seconds. The composite resin polymerization was evaluated by infrared spectrophotometry (FTIR) and Knoop hardness number (KHN). The temperature at the curing tip was evaluated. The results were analyzed using ANOVA and Tukey test (α=0.05). RESULTS: According to FTIR and KHN, the polymerization of the composite resin was statistically higher with the QTH. The temperature obtained with the QTH 20 s (45.44ºC) and 30 s (45.84ºC) was statistically higher than the QTH 10 s (39.90ºC). The PAC 1 s (27.12ºC), 2 s (28.48ºC) and 3 s (29.96ºC) presented the lowest temperature and did not differ statistically among them. CONCLUSION: Transbond XT light-activated for 10, 20 and 30 seconds with the QTH presented higher degree of conversion and hardness in comparison with those obtained with the PAC for 1, 2 and 3 seconds, and the QTH generated more heat than the PAC.


OBJETIVO: Analisar, in vitro, as fontes luminosas Halógena (QTH) e Xenon (PAC) no grau de conversão e dureza de uma resina composta e também o calor gerado por estas unidades. METODOLOGIA: discos com resina Transbond XT foram fotoativados por 10, 20 e 30 segundos com QTH (Curing light XL 3000) ou com PAC (Apollo 95E) por 1, 2 e 3 segundos. A resina composta foi analisada por meio de espectrofotometria infravermelha (FTIR) e pelo teste de dureza Knoop (KHN). A temperatura na ponta dos aparelhos foi também avaliada. Os resultados foram analisados usando ANOVA e Tuckey test (α=0.05). RESULTADOS: Conforme FTIR e KHN a polimerização do compósito foi estatisticamente maior com QTH. A temperatura obtida do QTH com 20 segundos (45,44ºC) foi estatisticamente maior do que com 10 segundos (39,90ºC). O PAC com 1, 2 e 3 segundos apresentou as temperaturas mais baixas e não diferem estatisticamente entre si. CONCLUSÃO: A resina Transbond XT fotoativada por 10, 20 e 30 segundos com QTH apresentou maior grau de conversão e dureza em comparação com PAC por 1, 2 e 3 segundos. O QTH produziu mais calor que o PAC.


Asunto(s)
Dureza/fisiología , Luces de Curación Dental , Resinas Compuestas , Xenón/farmacología
10.
J Appl Oral Sci ; 18(1): 68-74, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20379684

RESUMEN

OBJECTIVES: To determine the influence of the light curing units on the shear bond strength of orthodontic brackets. MATERIAL AND METHODS: Seventy-two premolars were divided into six groups (n=12): Group I: brackets bonded with Transbond and polymerization with halogen light; Group II: Transbond and LED; Group III: Fuji Ortho and halogen light; Group IV: Fuji Ortho and LED; Group V: Fuji Ortho, without acid and halogen light; Group VI: Fuji Ortho, without acid and LED. The groups were tested to shear strength in a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by ANOVA and Tukey's test. RESULTS: The composite resin presented higher shear bond strength than the resin-modified glass ionomer cement (p<0.05). The halogen light and LED sources produced similar shear bond strength (p>0.05). CONCLUSION: The shear bond strength was influenced by the material but not by the light-curing unit. The use of LED reduced the experimental time by approximately 60%, with the same curing efficiency.


Asunto(s)
Luces de Curación Dental , Aleaciones Dentales/química , Recubrimiento Dental Adhesivo , Cementos Dentales/química , Soportes Ortodóncicos , Grabado Ácido Dental , Resinas Acrílicas/química , Silicatos de Aluminio/química , Resinas Compuestas/química , Luces de Curación Dental/clasificación , Análisis del Estrés Dental/instrumentación , Cementos de Ionómero Vítreo/química , Humanos , Polímeros/química , Dosis de Radiación , Cementos de Resina/química , Resistencia al Corte , Acero Inoxidable/química , Estrés Mecánico , Propiedades de Superficie , Factores de Tiempo
11.
J. appl. oral sci ; 18(1): 68-74, Jan.-Feb. 2010. ilus, tab
Artículo en Inglés | LILACS | ID: lil-545029

RESUMEN

OBJECTIVES: To determine the influence of the light curing units on the shear bond strength of orthodontic brackets. MATERIAL AND METHODS: Seventy-two premolars were divided into six groups (n=12): Group I: brackets bonded with Transbond and polymerization with halogen light; Group II: Transbond and LED; Group III: Fuji Ortho and halogen light; Group IV: Fuji Ortho and LED; Group V: Fuji Ortho, without acid and halogen light; Group VI: Fuji Ortho, without acid and LED. The groups were tested to shear strength in a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by ANOVA and Tukey's test. RESULTS: The composite resin presented higher shear bond strength than the resin-modified glass ionomer cement (p<0.05). The halogen light and LED sources produced similar shear bond strength (p>0.05). CONCLUSION: The shear bond strength was influenced by the material but not by the light-curing unit. The use of LED reduced the experimental time by approximately 60 percent, with the same curing efficiency.


Asunto(s)
Humanos , Luces de Curación Dental , Recubrimiento Dental Adhesivo , Aleaciones Dentales/química , Cementos Dentales/química , Soportes Ortodóncicos , Grabado Ácido Dental , Resinas Acrílicas/química , Silicatos de Aluminio/química , Resinas Compuestas/química , Luces de Curación Dental/clasificación , Análisis del Estrés Dental/instrumentación , Cementos de Ionómero Vítreo/química , Polímeros/química , Dosis de Radiación , Cementos de Resina/química , Resistencia al Corte , Estrés Mecánico , Propiedades de Superficie , Acero Inoxidable/química , Factores de Tiempo
12.
Eur J Orthod ; 32(1): 83-6, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19726490

RESUMEN

The purpose of this study was to assess the influence of two light units, a quartz-tungsten-halogen (QTH) and a light-emitting diode (LED), on the hardness and degree of conversion of an orthodontic composite resin. Sixty specimen disks were prepared from Transbond XT composite resin (3M Unitek) and light cured for 10, 20, and 30 seconds with a QTH (Curing Light XL 3000, 3M Unitek) or a LED (Ortholux, 3M Unitek) light-curing unit for 5, 10, and 15 seconds. Composite resin polymerization was evaluated by Fourier-transform infrared (FTIR) spectrophotometry and Knoop hardness number (KHN). The results were statistically analysed using analysis of variance and Tukey's multiple comparisons test (alpha = 0.05). The highest KHN was obtained with the QTH at 30 (25.19 KHN) and 20 (24.01) seconds, which did not differ statistically, and in the LED 15 second (21.86) group. The QTH 10 second group (20.53) did not differ statistically from the QTH 20 second or the LED 5 (19.96) and 15, or 10 second (18.95) groups. According to FTIR, there was no statistical difference for the degree of conversion among the groups, QTH 10 (43.42 per cent), QTH 20 (46.12 per cent), QTH 30 (45.30 per cent), LED 10 (47.02 per cent), or LED 15 (47.24 per cent) seconds. The lowest degree of conversion was obtained for the LED 5 second group (38.97 per cent), which did not differ statistically from the QTH 10 second group. Light curing with the LED resulted in a reduction of 50 per cent in the time recommended for use of the QTH light with the composite resin, Transbond XT.


Asunto(s)
Resinas Compuestas/efectos de la radiación , Luces de Curación Dental/clasificación , Cementos Dentales/efectos de la radiación , Dureza , Ortodoncia/instrumentación , Cementos de Resina/efectos de la radiación , Análisis de Varianza , Ensayo de Materiales , Espectroscopía Infrarroja por Transformada de Fourier , Estadísticas no Paramétricas , Factores de Tiempo
13.
Rev. odonto ciênc ; 24(3): 274-278, July-Sept. 2009. graf, ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-873870

RESUMEN

Purpose: This in vitro study aimed to analyze the force degradation of four commercial brands of orthodontic elastics chain (Morelli, Ormco, TP, and Unitek) over 21 days. Methods: The elastics chains were stretched and maintained at a standardized distance equivalent to a force of 150 g. The amount of force generated by the elastics chains were measured by using a dynamometer (ZEUZAN 300 g) at intervals of 30 minutes, 7, 14, and 21 days. Data were analyzed by ANOVA and Tukey's test at the 5% level of significance. Results: There was a reduction of 5% to 15% in the amount of force generated by the elastic chains after 30 minutes and of 22% to 47% after 21 days of elastic activation. Conclusion: Unitek chains displayed the highest percentage of force degradation, while TP exhibited the smallest percentage of force degradation and showed the greatest stability at all intervals tested.


Objetivo: Este estudo teve por objetivo analisar a degradação da força gerada por quatro marcas comerciais de elásticos ortodônticos em cadeia (Morelli, Ormco, TP e Unitek) em função do tempo. Metodologia: Os elásticos foram mantidos continuamente estirados a uma distância equivalente à força de 150 g. A leitura da quantidade de força gerada pelas correntes elásticas foi mensurada utilizando-se um dinamômetro da marca ZEUZAN 300 g, nos intervalos: 30 minutos, 7, 14, 21 dias. Os resultados foram analisados por ANOVA e teste de Tukey ao nível de significância de 0,05. Resultados: Verificou-se uma redução na quantidade de força gerada pelos elásticos de 5% a 15% em 30 minutos de teste e de 22% a 47% em 21 dias de estiramento constante. Conclusão: A marca Unitek obteve um maior percentual de degradação de força, enquanto a marca TP um menor percentual de degradação de força mostrando comportamento mais estável em todos os intervalos de tempo testados.


Asunto(s)
Elastómeros/uso terapéutico , Ortodoncia/instrumentación
14.
Rev. Clín. Ortod. Dent. Press ; 7(2): 74-78, abr.-maio 2008. graf, tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-519746

RESUMEN

Esse estudo teve o objetivo de determinar in vitro a influência da luz halógena e do LED na resistência de união de braquetes colados com cimento de iônomero de vidro modificado por resina (Fuji Ortho LC®- FOLC - GC América Inc.®). Vinte pré-molares tiveram suas raízes seccionadas e desprezadas. As coroas foram incluídas em tubos plásticos (PVC) e aleatoriamente divididas em 2 grupos: grupo I - braquetes fotopolimerizados pela luz halógena por 40 segundos; grupo II - braquetes fotopolimerizados pelo LED por 15 segundos. Após a profilaxia, foi aplicado ácido fosfórico a 37% por 10 segundos nas superfícies de esmalte e os braquetes colados de acordo com as instruções do fabricante. Os espécimes foram armazernados em água destilada a 37ºC por 24 horas. Posteriormente, os 2 grupos experimentais foram submetidos ao teste de cisalhamento na máquina de ensaio universal (EMIC DL 2000) com velocidade de 1mm/min até a descolagem do braquete. Os resultados foram analisados através do teste t Student e demonstraram que não houve diferença estatística. O IAR (Índice de Adesivo Residual) mostrou que não há diferença na forma de descolagem dos braquetes entre os grupos I e II.


Asunto(s)
Soportes Ortodóncicos , Resistencia al Corte
15.
Rev. Clín. Ortod. Dent. Press ; 6(4): 64-72, ago.-set. 2007. tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-856198

RESUMEN

O presente estudo tem o objetivo de realizar uma compilação dos principais artigos existentes na literatura, voltados para a investigação das alterações adaptativas na articulação temporomandibular, decorrente do avanço mandibular com o aparelho Herbst. Para tentar elucidar essas alterações procurou-se discorrer sobre a pesquisas experimentais realizadas em animais, sob diferentes perspectivas metodológicas, como também pesquisas clínicas realizadas em humanos, nas quais foram utilizados diferentes métodos de diagnóstico por imagem. Independentemente da natureza do estudo, parece evidente que ocorrem alterações remodeladoras nas superfícies articulares, caracterizadas, principalmente, por uma aposição óssea na superfície posterior e superior do côndilo e uma neoformação óssea na fossa articular, localizada na região anterior da espinha pós-glenóide. Esses resultados positivos são acompanhados por uma ausência de alterações adversas no côndilo, disco, fossa ou eminência articular. No entanto, alguma dúvida ainda persiste sobre o real mecanismo responsável pela remodelação do côndilo e fossa articular frente ao avanço mandibular


Asunto(s)
Articulación Temporomandibular/anatomía & histología , Remodelación Ósea , Avance Mandibular , Aparatos Ortodóncicos
16.
Rev. odonto ciênc ; 22(57): 238-242, jul.-set. 2007. ilus, graf
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-495267

RESUMEN

A resina composta é um dos materiais mais utilizados para a colagem ortodôntica, sendo que, a sua polimerização ocorre através da energia luminosa. A luz halógena é a fonte luminosa mais utilizada, pois apresenta baixo custo e fßcil manutenção. Entretanto, o tempo necessßrio para a polimerização dos materiais é longo e a vida útil dos aparelhos fotopolimerizadores é relativamente curta. A fotoativação através do LED (ligth emitting diode) vem ganhando espaço, pois apresenta um tempo curto para a polimerização dos materiais e uma vida útil longa. Esse estudo teve por objetivo, determinar, in vitro, a influência da luz halógena e do LED na resistência de união de ôbracketsõ colados ao esmalte de dentes humanos. Como material de colagem foi utilizado a resina ortodôntica Transbond XT (3M-Unitek - Br). Foram selecionados 20 pré-molares, os quais foram preparados para colagem através de profilaxia e condicionamento do esmalte com ßcido ortofosfórico à 37%. Então, os corpos-de-prova foram divididos em 2 grupos de acordo com a fonte luminosa utilizada para polimerização: Grupo I - fotoativação pela luz halógena por 40 segundos; Grupo II - fotoativação pelo LED por 15 segundos. Após 24 horas, os 2 grupos foram submetidos ao teste de cisalhamento com velocidade de 1 mm por minuto até a descolagem do ôbracketõ. Os resultados obtidos através do t Student demostraram que não houve diferença estatística na resistência de união entre o Grupo I (14,96MPa ± 5,70) e o Grupo II (13,08MPa ± 4,33). Concluiu-se que, tanto a luz halógena quanto o LED propiciam força adequada para a colagem ortodôntica.


Asunto(s)
Humanos , Soportes Ortodóncicos , Esmalte Dental , Técnicas In Vitro , Luz , Resistencia al Corte
18.
Rev. dent. press ortodon. ortopedi. facial ; 11(3): 81-87, maio-jun. 2006. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-431880

RESUMEN

OBJETIVO: comparar a resistência ao cisalhamento de cinco materiais utilizados na cimentação de bandas ortodônticas: um cimento de ionômero de vidro convencional (Ketac Cem), dois cimentos de ionômero de vidro modificados por resina (3M Multicure Glass Ionomer Cement e Fuji Ortho LC) e duas resinas compostas modificadas por poliácidos (Ultra Band-Lok e Transbond Plus). METODOLOGIA: sobre a superfície de um segmento de banda (6 x 6mm) foi posicionada uma matriz com um orifício de 3mm de diâmetro na qual foi inserido o material para cimentação. Metade da amostra foi jateada com partículas de óxido de alumínio. Os corpos-de-prova foram armazenados a 37ºC por 24 horas em umidade relativa de 100 por cento e submetidos ao teste de cisalhamento a uma velocidade de 0,5mm/min. Utilizou-se ANOVA e o teste de comparações múltiplas de Tukey para comparar os grupos em cada tipo de superfície estudada (com ou sem jateamento), e o teste t Student para amostras pareadas para a comparação dos grupos jateados e não-jateados (p=0,01). RESULTADOS: nos grupos não-jateados, Ultra Band-Lok apresentou uma resistência de união significativamente maior (p<0,01) que a obtida pelos outros materiais, os quais não apresentaram diferença significante entre si. Após o jateamento, as resinas compostas modificadas por poliácidos apresentaram uma resistência de união significativamente maior (p<0,01) que a obtida pelos demais cimentos, sendo que 3M Multicure Glass Ionomer apresentou um valor de união superior (p<0,01) ao obtido pelo Ketac Cem e Fuji Ortho LC. CONCLUSÃO: o jateamento aumentou significativamente (p<0,01) a resistência de união em todos os grupos.


Asunto(s)
Humanos , Abrasión Dental por Aire/métodos , Cementación , Materiales de Impresión Dental , Resinas Compuestas , Resistencia al Corte/métodos
19.
Rev. odonto ciênc ; 21(51): 43-47, jan.-mar. 2006. ilus, tab, graf
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-495253

RESUMEN

A mordida cruzada posterior (MCP) é uma malolusão de alta prevalência (7 a 23,3%) que caracteriza-se pela discrepância transversa da arcada maxilar, tendo indicação de tratamento precoce jß que não possui autocorreção. A literatura relata que esta maloclusão tem origem, basicamente, em 3 estruturas: dento-alveolar (MCP dentßria), muscular (MCP funcional) e óssea (MCP esquética). O objetivo desta pesquisa foi avaliar a profundidade palatina de pacientes com MCP buscando identificar possíveis alterações verticais na região palatina. Foram selecionados 20 modelos de estudo de pacientes com MCP e 20 modelos sem MCP, com relação de molares de classe I para o grupo controle, todos obtidos dos arquivos da Disciplina de Ortodontia da Faculdade de Odontologia da PUCRS. A profundidade palatina foi medida na região de primeiros molares superiores com uma régua milimetrada com a ponta preparada para melhor adaptação na rafe palatina mediana. Os resultados mostraram que o grupo com MCP teve uma média de 1,67 cm de profundidade palatina, enquanto que para o grupo controle a média foi de 1,56 cm. Conclui-se após anßlise estatística que o grupo com MCP teve uma profundidade palatina maior do que o grupo controle.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Maloclusión , Hueso Paladar
20.
J. bras. ortodon. ortop. facial ; 10(59/60): 341-357, set.-dez. 2005.
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-510985

RESUMEN

As alterações dentárias sagitais e verticais foram avaliadas em 22 indivíduos com má-oclusão de Classe II, 1ª divisão (11 do gênero masculino e 11 do gênero feminino), com média de idade de 9,01 anos (+/- 06 meses), apresentando padrão facial Classe II, deficiência mandibular e padrão esquelético de Classe II (ANB3 50 e Co-Gn-Co-Sn £20mm), tratados consecutivamente com o aparelho Herbst por um período de 12 meses. Todos os indivíduos encontravam-se no período intertransitório da dentadura mista e no estágio pré-puberal. Para tal avaliação, utilizaram-se telerradiografias de perfil obtidas em três tempos distintos: T1 inicial, T2 -logo após a remoção do aparelho, T3 - 02 anos após o final do tratamento. O grupo controle foi constituído de 105 indivíduos com má-oclusão de Classe II esquelética, não tratados ortodonticamente, pareados quanto às idades óssea e cronológica ao grupo experimental. O tratamento estatístico foi realizado por meio da Análise de Variância (ANOVA), complementada pelo teste de Comparações Múltiplas de Tukey e Teste T de Student, com nível de significância de 5%. Os resultados evidenciaram que as alterações dentárias envolveram vestibularização dos incisivos inferiores, verticalização e extrusão dos incisivos superiores, distalização dos molares superiores e mesialização e extrusão dos molares inferiores. Essas alterações dentárias contribuíram em cerca de 59% para correção da relação molar de Classe II e em 34,7% para correção do trespasse horizontal. A tendência de redução da magnitude das alterações dentárias induzidas pela terapia, após 02 anos da remoção do aparelho Herbst, esteve associada principalmente a um movimento mesial dos molares superiores e à recidiva da inclinação vestibular dos incisivos inferiores, embora uma melhora significativa no trespasse horizontal e na relação ainda tenha sido evidente.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Aparatos Activadores , Cefalometría , Maloclusión Clase I de Angle , Análisis de Varianza , Movimiento Mesial de los Dientes , Métodos de Anclaje en Ortodoncia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...