Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(9)2022 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-35591070

RESUMEN

Compliant mechanisms have gained an increasing interest in recent years, especially in relation to the possibility of using 3D printers for their production. These mechanisms typically find applications in precise positioning systems of building robotic devices or in sensing where they can be used to characterize displacement. Three-dimensional printing with PLA materials allows fiber optic-based sensors to be incorporated into the structures of properly designed compliant mechanisms. Therefore, in this paper, an innovative technology is described, of a Fiber Bragg Grating (FBG) sensor embedded in a measuring head which was then inserted into a specially designed mechanical transmission element. The shape of this element is based on clippers that allow to freely modify the amplification of displacement amplitude so that the FBG sensor always works in the most optimal regime without any need to modify its external dimensions. Flexural sensitivity of the replaceable measuring head equal to 1.26 (mε/mm) can be adapted to the needs of the flexure design.


Asunto(s)
Tecnología de Fibra Óptica , Fibras Ópticas , Tecnología de Fibra Óptica/métodos
2.
Materials (Basel) ; 15(3)2022 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-35161116

RESUMEN

This article presents an attempt to determine the effect of the MXene phase addition and its decomposition during sintering with the use of the spark plasma sintering method on mechanical properties and residual stress of silicon carbide based composites. For this purpose, the unreinforced silicon carbide sinter and the silicon carbide composite with the addition of 2 wt.% of Ti3C2Tx were tested. The results showed a significant increase of fracture toughness and hardness for composite, respectively 36% and 13%. The numerical study involving this novel method of modelling shows the presence of a complex state of stress in the material, which is related to the anisotropic properties of graphitic carbon structures formed during sintering. An attempt to determine the actual values of residual stress in the tested materials using Raman spectroscopy was also made. These tests showed a good correlation with the constructed numerical model and confirmed the presence of a complex state of residual stress.

3.
Acta Bioeng Biomech ; 21(3): 75-86, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31798024

RESUMEN

PURPOSE: Bone conduction stimulation applied on the otic capsule may be used in a conductive hearing loss treatment as an alternative to the bone conduction implants in clinical practice. A finite element study was used to evaluate the force amplitude and direction needed for the stimulation. METHODS: A finite element model of a female temporal bone with a precisely reconstructed cochlea was subjected to a harmonic analysis assuming two types of stimulation. At first, the displacement amplitude in the form of air conduction stimulation was applied on the stapes footplate. Then the force amplitude was applied on the otic capsule in the form of bone conduction stimulation. The two force directions were considered: 1) the primary direction, when a typical opening is performed during mastoidectomy, and was coincident with the axis of an imaginary cone, inscribed in the opening, and 2) the direction perpendicular to the stapes footplate. The force amplitude was set so that the response from the cochlea corresponded to the result of air conduction stimulation applied on the stapes footplate. RESULTS: The amplitude and phase of vibration and the volume displacement on the round window membrane were considered as well as vibrations of the basilar membrane, spiral lamina, and promontory. CONCLUSIONS: The cochlear response was comparable for the two types of stimulation. The efficiency of bone conduction stimulation depended on the force direction. For the primary direction, the force was a few times smaller than for the direction perpendicular to the stapes footplate.


Asunto(s)
Conducción Ósea/fisiología , Modelos Teóricos , Estribo/fisiología , Hueso Temporal/fisiología , Adulto , Aire , Membrana Basilar/fisiología , Femenino , Análisis de Elementos Finitos , Humanos , Hueso Temporal/diagnóstico por imagen , Vibración
4.
Hear Res ; 310: 13-26, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24463104

RESUMEN

The effect of different stapes prostheses on the basilar membrane (BM) motion was determined. To that end, a three dimensional finite element (FE) model of the passive human cochlea was developed. Passive responses of the BM were found based on coupled fluid-structure interactions between the cochlear solid structures and the scala fluids. The passive BM vibrations in normal (healthy) cochlea were compared with vibrations in the cochlea in which a 0.4-mm piston or a proposed new type of prosthesis was implanted. The proposed chamber prosthesis was not experimentally implanted, but only numerically simulated. Design of the new chamber stapes prosthesis is presented for the first time in this paper. The simulation results showed 10-20 dB decrease in BM displacement amplitude in the case of the piston. In contrast, the BM responses in the cochlea with the new prosthesis are higher with respect to the healthy ear. The results obtained in this study are promising for further research to optimize the design of the new chamber stapes prosthesis.


Asunto(s)
Membrana Basilar/fisiología , Implantes Cocleares , Cirugía del Estribo/instrumentación , Análisis de Elementos Finitos , Humanos , Modelos Biológicos , Diseño de Prótesis , Estribo/anatomía & histología , Estribo/fisiología , Cirugía del Estribo/métodos , Vibración
5.
Biomech Model Mechanobiol ; 12(6): 1243-61, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23462937

RESUMEN

Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner. The objective of this study was to assess the influence of stapedotomy surgery on round window membrane vibration and to estimate the postoperative outcomes using the finite element (FE) method. The study hypothesis is that the three-dimensional FE model developed of the human inner ear, which simulates the round window (RW) membrane vibration, can be used to assess the influence of stapedotomy on auditory outcomes achieved after the surgical procedure. An additional objective of the study was to enable the simulation of RW membrane vibration after stapedotomy using a new type of stapes prosthesis currently under investigation at Warsaw University of Technology. A three-dimensional finite element (FE) model of the human inner ear was developed and validated using experimental data. The model was then used to simulate the round window membrane vibration before and after stapedotomy surgery. Functional alterations of the RW membrane vibration were derived from the model and compared with the results of experimental measurements from temporal bones of a human cadaver. Piston stapes prosthesis implantation causes an approximately fivefold (14 dB) lower amplitude of the RW membrane vibrations compared with normal anatomical conditions. A satisfactory agreement between the FE model and the experimental data was found. The new prosthesis caused an increase of 20-30 dB in the RW displacement amplitude compared with the 0.4-mm piston prosthesis. In all frequencies, the FE model predicted a RW displacement curve that was above the experimental curves for the normal ear. The stapedotomy can be well simulated by the FE model to predict the auditory outcomes achieved following this otosurgery procedure. The 3D FE model developed in this study may be used to optimize the geometry of a new type of stapes prosthesis in order to achieve a similar sound transmission through the inner ear as for a normal middle ear. This should provide better auditory outcomes for patients with stapedial otosclerosis.


Asunto(s)
Análisis de Elementos Finitos , Ventana Redonda/fisiología , Ventana Redonda/cirugía , Cirugía del Estribo , Vibración , Adolescente , Adulto , Humanos , Modelos Biológicos , Prótesis Osicular , Reproducibilidad de los Resultados , Hueso Temporal/fisiología , Hueso Temporal/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...