Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
J Neurointerv Surg ; 15(7): 679-683, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35551072

RESUMEN

BACKGROUND: The Surpass flow diverter was developed to treat intracranial aneurysms not amenable to standard treatment. Indications for use allow placement in the internal carotid artery to the terminus, including the communicating artery segment. METHODS: The Surpass Intracranial Aneurysm Embolization System Pivotal Trial to Treat Large or Giant Wide Neck Aneurysms (SCENT) trial is an international, multicenter, prospective, non-randomized trial comparing the outcomes of Surpass flow diverter treatment with historic control designed to evaluate the effectiveness and safety of Surpass for the treatment of wide neck (≥4 mm) large or giant intracranial aneurysms ≥10 mm. The primary effectiveness endpoint is the percentage of subjects with 100% aneurysm occlusion without significant stenosis of the parent artery and without retreatment of the target aneurysm at 12 months. The primary safety endpoint is the percentage of subjects experiencing neurologic death or major ipsilateral stroke at 12 months. We report the effectiveness and safety of flow diversion in the subgroup of posterior communicating artery (PComA) aneurysms. RESULTS: Of the 180 patients treated, 38 harbored a PComA aneurysm. Mean aneurysm size was 12.2 mm and mean neck width was 4.8 mm. The mean number of Surpass devices used was 1.1 per procedure, with 94.7% of aneurysms treated with one flow diverter. The 12 month primary effectiveness rate was 73.7% (28/38). At 36 months, 68.4% (26/38) of aneurysms remained completely occluded. The 12 month major ipsilateral stroke or neurological death rate was 10.5%. No patients with PComA occlusion after flow diverter placement (54.5%) had clinical sequelae. CONCLUSIONS: SCENT demonstrated acceptable 12 month effectiveness of flow diversion in PComA aneurysms. Despite associated PComA occlusions in many cases, arterial occlusions were clinically silent. TRIAL REGISTRATION NUMBER: URL: https://www. CLINICALTRIALS: gov. Unique identifier: NCT01716117.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Accidente Cerebrovascular , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Estudios Prospectivos , Odorantes , Embolización Terapéutica/métodos , Accidente Cerebrovascular/terapia , Resultado del Tratamiento , Stents
3.
Nat Med ; 28(1): 117-124, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34949835

RESUMEN

Expansions of a G4C2 repeat in the C9ORF72 gene are the most common genetic cause of amyotrophic lateral sclerosis (ALS) and frontotemporal dementia (FTD), two devastating adult-onset neurodegenerative disorders. Using C9-ALS/FTD patient-derived cells and C9ORF72 BAC transgenic mice, we generated and optimized antisense oligonucleotides (ASOs) that selectively blunt expression of G4C2 repeat-containing transcripts and effectively suppress tissue levels of poly(GP) dipeptides. ASOs with reduced phosphorothioate content showed improved tolerability without sacrificing efficacy. In a single patient harboring mutant C9ORF72 with the G4C2 repeat expansion, repeated dosing by intrathecal delivery of the optimal ASO was well tolerated, leading to significant reductions in levels of cerebrospinal fluid poly(GP). This report provides insight into the effect of nucleic acid chemistry on toxicity and, to our knowledge, for the first time demonstrates the feasibility of clinical suppression of the C9ORF72 gene. Additional clinical trials will be required to demonstrate safety and efficacy of this therapy in patients with C9ORF72 gene mutations.


Asunto(s)
Proteína C9orf72/genética , Mutación , Oligonucleótidos Antisentido/genética , Animales , Proteína C9orf72/metabolismo , Fibroblastos/metabolismo , Humanos , Ratones , Ratones Transgénicos , Neuronas/metabolismo
4.
Radiol Imaging Cancer ; 3(4): e200069, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34170199

RESUMEN

Purpose To develop multimodality imaging techniques for measuring epidermal growth factor receptor (EGFR) as a therapy-relevant and metastasis-associated molecular marker in triple-negative mammary adenocarcinoma metastases. Materials and Methods An orthotopic bone metastasis EGFR-positive, triple-negative breast cancer (TNBC) model in rats was used for bioluminescence imaging, SPECT/CT, PET/CT, and MRI with quantitative analysis of transcripts (n = 22 rats). Receptor-specific MRI of EGFR expression in vivo was performed by acquiring spin-echo T1-weighted images after sequential administration of a pair of anti-EGFR antigen binding fragments, F(ab')2, conjugated to either horseradish peroxidase or glucose oxidase, which have complementing activities, as well as paramagnetic (gadolinium[III]-mono-5-hydroxytryptamide of 2,2',2''-(10-(2,6-dioxotetrahydro-2H-pyran-3-yl)-1,4,7,10-tetraazacyclododecane-1,4,7-triyl)triacetic acid, or Gd-5HT-DOTAGA) or positron-emitting (gallium 68-5HT-DOTAGA) substrates for MRI and PET/CT imaging, respectively. EGFR expression was confirmed by quantitative reverse transcriptase polymerase chain reaction and immunohistochemical analyses to compare with image findings. Results After surgical intraarterial delivery of TNBC cells, rats developed tumors that diverged into either rapidly growing osteolytic or slow-growing nonosteolytic tumors. Both tumor types showed receptor-specific initial MRI signal enhancement (contrast-to-noise ratio) that was three to six times higher than that of normal bone marrow (29.4 vs 4.9; P < .01). Micro PET/CT imaging of EGFR expression demonstrated a high level of heterogeneity with regional uptake of the tracer, which corresponded to region-of-interest MRI signal intensity elevation (121.1 vs 93.3; P < .001). Analysis of metastases with corroboration of imaging results showed high levels of EGFR protein and messenger RNA, or mRNA, expression in the invasive tumor. Conclusion Convergence of multimodal molecular receptor imaging enabled comprehensive assessment of EGFR overexpression in an orthotopic model of TNBC metastasis. Keywords: Animal Studies, Molecular Imaging-Cancer, MR-Contrast Agent, Radionuclide Studies, Skeletal-Appendicular, Metastases Supplemental material is available for this article. © RSNA, 2021.


Asunto(s)
Neoplasias Óseas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Animales , Neoplasias Óseas/diagnóstico por imagen , Receptores ErbB/genética , Fragmentos Fab de Inmunoglobulinas , Tomografía de Emisión de Positrones , Ratas
5.
J Neurointerv Surg ; 13(11): 1022-1026, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33443115

RESUMEN

BACKGROUND: Existing travel restrictions limit the mobility of proctors, significantly delaying clinical trials and the introduction of new neurointerventional devices. We aim to describe in detail technical and legal considerations regarding international teleproctoring, a tool that could waive the need for in-person supervision during procedures. METHODS: International teleproctoring was chosen to provide remote supervision during the first three intracranial aneurysm treatments with a new flow diverter (currently subject of a clinical trial) in the US. Real-time, high-resolution transmission software streamed audiovisual data to a proctor located in Canada. The software allowed the transmission of images in a de-identified, HIPAA-compliant manner. RESULTS: All three flow diverters were implanted as desired by operator and proctor and without complication. The proctor could swap between images from multiple sources and reported complete spatial and situational awareness, without any significant lag or delay in communication. Procedural times and radiologic dose were similar to those of uncomplicated, routine flow diversion cases at our institution. CONCLUSIONS: International teleproctoring was successfully implemented in our clinical practice. Its first use provided important insights for establishing this tool in our field. With no clear horizon for lifting the current travel restrictions, teleproctoring has the potential to remove the need for proctor presence in the angiography suite, thereby allowing the field to advance through the continuation of trials and the introduction of new devices in clinical practice. In order for this tool to be used safely and effectively, highly reliable connection and high-resolution equipment is necessary, and multiple legal nuances have to be considered.


Asunto(s)
COVID-19 , Procedimientos Endovasculares , Aneurisma Intracraneal , Canadá , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , SARS-CoV-2
6.
Cardiovasc Intervent Radiol ; 44(2): 318-324, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33179161

RESUMEN

PURPOSE: The first-pass effect during mechanical thrombectomy improves clinical outcomes regardless of first-line treatment approach, but current success rates for complete clot capture with one attempt are still less than 40%. We hypothesize that the ThrombX retriever (ThrombX Medical Inc.) can better engage challenging clot models during retrieval throughout tortuous vasculature in comparison with a standard stent retriever without increasing distal emboli. MATERIALS AND METHODS: Thrombectomy testing with the new retriever as compared to the Solitaire stent retriever was simulated in a vascular replica with hard and soft clot analogs to create a challenging occlusive burden. Parameters included analysis of distal emboli generated per clot type, along with the degree of recanalization (complete, partial or none) by retrieval device verified by angiography. RESULTS: The ThrombX device exhibited significantly higher rates of first-pass efficacy (90%) during hard clot retrieval in comparison with the control device (20%) (p < 0.009), while use of both techniques during soft clot retrieval resulted in equivalent recanalization. The soft clot model generated higher numbers of large emboli (>200 µm) across both device groups (p = 0.0147), and no significant differences in numbers of distal emboli were noted between the ThrombX and Solitaire techniques. CONCLUSIONS: Irrespective of clot composition, use of the ThrombX retriever demonstrated high rates of complete recanalization at first pass in comparison with a state-of-the-art stent retriever and proved to be superior in the hard clot model. Preliminary data suggest that risk of distal embolization associated with the ThrombX system is comparable to that of the control device.


Asunto(s)
Embolia Intracraneal/cirugía , Trombectomía/instrumentación , Trombectomía/métodos , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Embolia Intracraneal/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Resultado del Tratamiento
7.
Nat Commun ; 11(1): 3851, 2020 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-32737314

RESUMEN

Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries' microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases. Here, we present a neurovascular high-frequency optical coherence tomography (HF-OCT) system, including an imaging console and an endoscopic probe designed to rapidly acquire volumetric microscopy data at a resolution approaching 10 microns in tortuous cerebrovascular anatomies. Using a combination of in vitro, ex vivo, and in vivo models, the feasibility of HF-OCT for cerebrovascular imaging was demonstrated.


Asunto(s)
Arteria Basilar/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Arterias Cerebrales/diagnóstico por imagen , Microscopía/métodos , Tomografía de Coherencia Óptica/métodos , Arteria Vertebral/diagnóstico por imagen , Angiografía/instrumentación , Angiografía/métodos , Animales , Cadáver , Circulación Cerebrovascular/fisiología , Humanos , Microscopía/instrumentación , Porcinos , Tomografía de Coherencia Óptica/instrumentación
8.
Neurosurgery ; 87(6): 1311-1319, 2020 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-32463884

RESUMEN

BACKGROUND: Tissue growth over covered branches is a leading cause of delayed thrombotic complications after flow-diverter stenting (FDS). Due to insufficient resolution, no imaging modality is clinically available to monitor this phenomenon. OBJECTIVE: To evaluate high-frequency optical coherence tomography (HF-OCT), a novel intravascular imaging modality designed for the cerebrovascular anatomy with a resolution approaching 10 microns, to monitor tissue growth over FDS in an arterial bifurcation model. METHODS: FDS were deployed in a rabbit model (n = 6), covering the aortic bifurcation. The animals were divided in different groups, receiving dual antiplatelet therapy (DAPT) (n = 4), aspirin only (n = 1), and no treatment (n = 1). HF-OCT data were obtained in vivo at 3 different time points in each animal. For each cross-sectional image, metal and tissue coverage of the jailed ostium was quantified. Scanning electron microscopy images of harvested arteries were subsequently obtained. RESULTS: Good quality HF-OCT data sets were successfully acquired at implant and follow-up. A median value of 41 (range 21-55) cross-sectional images were analyzed per ostium for each time point. Between 0 and 30 d after implant, HF-OCT analysis showed a significantly higher ostium coverage when DAPT was not given. After 30 d, similar growth rates were found in the DAPT and in the aspirin group. At 60 d, a coverage of 90% was reached in all groups. CONCLUSION: HF-OCT enables an accurate visualization of tissue growth over time on FDS struts. The use of FDS in bifurcation locations may induce a drastic reduction of the jailed-branch ostium area.


Asunto(s)
Trombosis , Tomografía de Coherencia Óptica , Animales , Arterias , Aspirina , Conejos , Stents
9.
J Neurointerv Surg ; 12(2): 209-213, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31363042

RESUMEN

INTRODUCTION: The neuroprotective benefit of therapeutic hypothermia (TH) has been demonstrated, but systemic side effects and time required to achieve effective TH in acute ischemic stroke (AIS) care limits clinical use. We investigate rapid and localized cooling using a novel insulated catheter in an ischemia-reperfusion model. METHODS: In phase I (n=4), cold saline was delivered to the canine internal carotid artery via an insulated catheter. Temperature was measured using intracerebral thermocouples. The coolant flow rate was varied to meet a target temperature of 31-32°C in the hemisphere infused. In phase II (n=8), a temporary middle cerebral artery occlusion was created. Five dogs underwent localized TH at the optimal flow rate from phase I, and the remaining animals were untreated controls. Cooling was initiated 5 min before recanalization and continued for an additional 20 min following 45 min of occlusion duration. The outcome was infarct volume and neurological function. RESULTS: Ipsilateral tissue cooling rates were 2.2±2.5°C/min at a flow rate of 20-40 mL/min with an observed minimum of 23.8°C. Tissue cooling was localized to the ipsilateral side of the infusion with little impact on temperatures of the core or contralateral hemisphere of the brain. In phase II, animals tolerated TH with minimal systemic impact. Infarct volume in treated animals was 0.2±0.2 cm3, which was smaller than in sham animals (3.8±1.0 cm3) as well as six untreated historical control animals (4.0±2.8 cm3) (p=0.013). CONCLUSIONS: Proof-of-concept data show that localised brain TH can be quickly and safely achieved through a novel insulated catheter. The small infarct volumes suggest potential benefit for this approach.


Asunto(s)
Isquemia Encefálica/terapia , Crioterapia/métodos , Infarto de la Arteria Cerebral Media/terapia , Prueba de Estudio Conceptual , Accidente Cerebrovascular/terapia , Animales , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Isquemia Encefálica/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Catéteres , Modelos Animales de Enfermedad , Perros , Hipotermia Inducida/métodos , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Masculino , Accidente Cerebrovascular/diagnóstico por imagen
10.
Mol Ther ; 28(2): 411-421, 2020 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-31813800

RESUMEN

Global gene delivery to the CNS has therapeutic importance for the treatment of neurological disorders that affect the entire CNS. Due to direct contact with the CNS, cerebrospinal fluid (CSF) is an attractive route for CNS gene delivery. A safe and effective route to achieve global gene distribution in the CNS is needed, and administration of genes through the cisterna magna (CM) via a suboccipital puncture results in broad distribution in the brain and spinal cord. However, translation of this technique to clinical practice is challenging due to the risk of serious and potentially fatal complications in patients. Herein, we report development of a gene therapy delivery method to the CM through adaptation of an intravascular microcatheter, which can be safely navigated intrathecally under fluoroscopic guidance. We examined the safety, reproducibility, and distribution/transduction of this method in sheep using a self-complementary adeno-associated virus 9 (scAAV9)-GFP vector. This technique was used to treat two Tay-Sachs disease patients (30 months old and 7 months old) with AAV gene therapy. No adverse effects were observed during infusion or post-treatment. This delivery technique is a safe and minimally invasive alternative to direct infusion into the CM, achieving broad distribution of AAV gene transfer to the CNS.


Asunto(s)
Cisterna Magna/metabolismo , Dependovirus/genética , Expresión Génica , Técnicas de Transferencia de Gen , Vectores Genéticos/genética , Transducción Genética , Animales , Catéteres , Sistema Nervioso Central/metabolismo , Genes Reporteros , Terapia Genética , Vectores Genéticos/administración & dosificación , Humanos , Inyecciones Espinales , Imagen por Resonancia Magnética , Modelos Animales , Ovinos , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Transgenes , Grabación en Video
11.
J Neurointerv Surg ; 11(12): 1243-1248, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31103992

RESUMEN

PURPOSE: To develop a preclinical model of stroke with a large vessel occlusion treated with mechanical thrombectomy. MATERIALS AND METHODS: An ischemic stroke model was created in dogs by the introduction of an autologous clot into the middle cerebral artery (MCA). A microcatheter was navigated to the clot and a stent retriever thrombectomy was performed with the goal to achieve Thrombolysis in Cerebral Ischemia (TICI) 2b/3 reperfusion. Perfusion and diffusion MRI was acquired after clot placement and following thrombectomy to monitor the progression of restricted diffusion as well as changes in ischemia as a result of mechanical thrombectomy. Post-mortem histology was done to confirm MCA territory infarct volume. RESULTS: Initial MCA occlusion with TICI 0 flow was documented in all six hound-cross dogs entered into the study. TICI 2b/3 revascularization was achieved with one thrombectomy pass in four of six animals (67%). Intra-procedural events including clot autolysis leading to spontaneous revascularization (n=1) and unresolved vasospasm (n=1) accounted for thrombectomy failure. In one case, iatrogenic trauma during microcatheter navigation resulted in a direct arteriovenous fistula at the level of the cavernous carotid. Analysis of MRI indicated that a volume of tissue from the initial perfusion deficit was spared with reperfusion following thrombectomy, and there was also a volume of tissue that infarcted between MRI and ultimate recanalization. CONCLUSION: We describe a large animal stroke model in which mechanical thrombectomy can be performed. This model may facilitate, in a preclinical setting, optimization of complex multimodal stroke treatment paradigms for clinical translation.


Asunto(s)
Isquemia Encefálica/cirugía , Modelos Animales de Enfermedad , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Animales , Isquemia Encefálica/diagnóstico por imagen , Revascularización Cerebral/métodos , Perros , Femenino , Imagen por Resonancia Magnética , Estudios Retrospectivos , Accidente Cerebrovascular/diagnóstico por imagen , Resultado del Tratamiento
12.
J Neurointerv Surg ; 11(11): 1150-1154, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31036558

RESUMEN

BACKGROUND: High frequency optical coherence tomography (HF-OCT) is a novel intravascular imaging technology developed for use in the cerebral vasculature. We hypothesize that HF-OCT characterization of intrasaccular device neck coverage can prognosticate exclusion of the aneurysm from the circulation. METHODS: Bifurcation and sidewall aneurysms were made in six dogs. Seven aneurysms were treated with next generation intrasaccular devices (NGID) and four with traditional platinum coils. HF-OCT was performed to interrogate gaps in the neck coverage, coil herniation, or acute thrombus formation. Animals were re-imaged at 7, 30, 90, and 180 days following aneurysm embolization. An automated image processing method segmented the devices at the neck of the aneurysm and quantified neck coverage. The largest coverage gap was used to predict aneurysm occlusion at 180 days. RESULTS: No difference was found in occlusion rates between the coil and NGID groups (P=0.45). Successful segmentation of the NGID construct was achieved in all cases. A coverage gap >1 mm2 was found to predict failed aneurysm occlusion (P=0.047). This threshold was able to predict all cases of failed occlusion. The average number of devices needed to treat the aneurysm was lower in the NGID group (1.9 vs 6.75, P=0.009). HF-OCT showed strong agreement with scanning electron microscopy (bias 0.0024 mm2 (95% CI -0.0279, 0.0327)). CONCLUSIONS: HF-OCT enables precise and accurate measurement of coverage gaps at the neck of aneurysms treated with intrasaccular devices in vivo. We provide in vivo evidence that uniform aneurysm neck coverage by intrasaccular devices is critical for aneurysm occlusion.


Asunto(s)
Embolización Terapéutica/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Tomografía de Coherencia Óptica/métodos , Animales , Angiografía Cerebral/métodos , Perros , Embolización Terapéutica/instrumentación , Predicción , Masculino , Resultado del Tratamiento
13.
J Neurointerv Surg ; 11(9): 931-936, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30718384

RESUMEN

BACKGROUND: Evidence is mounting that first-pass complete recanalization during mechanical thrombectomy is associated with better clinical outcomes in patients presenting with an emergent large vessel occlusion. We hypothesize that aspiration achieving complete clot ingestion results in higher first-pass successful recanalization with quantitative reduction in distal emboli. METHODS: A patient-specific cerebrovascular replica was connected to a flow loop. Occlusion of the middle cerebral artery was achieved with clot analogs. Independent variables were the diameter of the aspiration catheter (0.054-0.088in) and aspiration pattern (static versus cyclical). Outcome measures were the first-pass rates of complete clot ingestion, the extent of recanalization, and the particle-size distribution of distal emboli. RESULTS: All aspiration catheters were successfully navigated to the occlusion. Complete clot ingestion during aspiration thrombectomy resulted in first-pass complete recanalization in every experiment, only achieved in 21% of experiments with partial ingestion (P<0.0001). Aspiration through the large bore 0.088in device resulted in the highest rates of complete clot ingestion (90%). Cyclical aspiration (18-29 inHg, 0.5 Hz) significantly increased the rate of complete clot ingestion (OR21 [1.6, 266]; P=0.04). In all experiments, complete clot ingestion resulted in fewer and smaller distal emboli. CONCLUSIONS: Complete clot ingestion results in fewer distal emboli and the highest rates of first-pass complete recanalization. The rate of complete ingestion during aspiration thrombectomy is a function of both the inner diameter of the aspiration catheter and use of cyclical aspiration.


Asunto(s)
Catéteres , Trombectomía/instrumentación , Trombectomía/métodos , Trombosis/cirugía , Animales , Bovinos , Trastornos Cerebrovasculares/cirugía , Embolización Terapéutica/métodos , Humanos , Arteria Cerebral Media/cirugía , Procedimientos de Cirugía Plástica/instrumentación , Procedimientos de Cirugía Plástica/métodos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/cirugía , Resultado del Tratamiento
14.
J Neurointerv Surg ; 11(3): 271-274, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30177546

RESUMEN

BACKGROUND: Despite high recanalization rates achieved with endovascular treatment of acute ischemic strokes, around 50% of eligible patients will not achieve a good outcome. Parameters that may determine patient outcomes include: time from puncture to recanalization, the collateral status, the anesthesia regimen, blood pressure management, and distal emboli. Characterization of distal emboli generated during mechanical thrombectomy has been performed in previous studies. OBJECTIVE: To further investigate the risk of distal embolization associated with microcatheter navigation across the clot. METHODS: A contrast-enhanced clot analog was used in an in vitro model that mimicked a middle cerebral artery occlusion within a complete circle of Willis vascular replica. The clot was crossed with one of the following microcatheters: Pro18, XT-27 or 3MAX. The emboli generated during the procedure were collected and measured. RESULTS: The use of Pro18 and XT-27 resulted in a significant reduction of visible particles (size ≥500 µm) as compared with the 3MAX catheter (P<0.003). For the size range between 8 and 200 µm, there was a trend for Pro18 to generate fewer particles (-18%) than XT-27 but without statistical significance (P>0.05). In comparison with previously published data, acquired under the same conditions, it was found that the clot crossing maneuver accounts approximately for 12% of the total number of small emboli (<200 µm) induced during a stent retriever-mediated mechanical thrombectomy procedure via a balloon guide catheter. CONCLUSIONS: The clot crossing maneuver has a significant effect on the total number of small particles induced during mechanical thrombectomy. Smaller microcatheter sizes should be favored when possible.


Asunto(s)
Catéteres , Infarto de la Arteria Cerebral Media/cirugía , Modelos Anatómicos , Neuronavegación/métodos , Trombosis/cirugía , Cateterismo/instrumentación , Cateterismo/métodos , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Humanos , Neuronavegación/instrumentación , Trombectomía/instrumentación , Trombectomía/métodos
16.
J Neurointerv Surg ; 10(11): 1097-1101, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29511117

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) is a high-resolution, intra-vascular diagnostic technique widely used for the characterization of vascular pathologies and optimization of stent implantation during percutaneous coronary intervention. OCT was used to investigate the in vivo vascular response to a new phosphorylcholine surface modified flow diverter (sPED). METHODS: In an in vivo rabbit aneurysmal model, we used two different types of flow diverters (classic Pipeline - cPED; and sPED) with or without dual antiplatelet therapy (four groups, n=10 per group). OCT cross-sectional area measurements were compared with histology in all animals. Neointimal hyperplasia (NIH) ratio was compared between OCT and histology at five different levels for each stent. The severity of NIH was also compared between the different stents, antiplatelet protocols, and vessel locations. RESULTS: OCT was used to calculate in-stent hyperplasia in 227 different locations corresponding to histology sections. OCT measurement strongly correlated with gold standard histology (r2=0.83; slope=0.988; P<0.0001). sPED had significantly less in-stent NIH than non-treated flow diverters (mean percent of lumen reduction 5.7% for sPED versus 8.9% for cPED; P<0.0001). The NIH ratio was slightly higher with dual antiplatelet therapy (DAPT) (NIH ratio=7.9% with DAPT versus 6.8% without DAPT; P<0.05). Complete and near complete occlusion rates of the aneurysms were not different with the cPED or sPED. CONCLUSION: OCT is a promising technique for immediate and long-term evaluation of flow diverter stent treatments. In an animal model, phosphorylcholine surface modified flow diverters induces less NIH after stent implant without reducing aneurysm occlusion rates.


Asunto(s)
Aneurisma Intracraneal/cirugía , Neointima/cirugía , Fosforilcolina , Stents Metálicos Autoexpandibles , Animales , Vasos Coronarios , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Hiperplasia/diagnóstico por imagen , Hiperplasia/etiología , Aneurisma Intracraneal/diagnóstico por imagen , Neointima/diagnóstico por imagen , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Conejos , Distribución Aleatoria , Stents Metálicos Autoexpandibles/efectos adversos , Tomografía de Coherencia Óptica/métodos
17.
J Neurointerv Surg ; 10(7): 693-697, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29127197

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) is a high resolution intravascular imaging method that allows visualization of flow diverter struts and the vessel wall. In this study, malapposition of the flow diverter that continues into the neck of the aneurysm, named communicating malapposition (CM), was investigated as a potential factor for delayed aneurysm healing. METHODS: 40 New Zealand White rabbits underwent elastase induced aneurysm creation, and were subsequently assigned to one of four treatment groups based on flow diverter type and administration of antiplatelet therapy. All animals underwent post device deployment balloon angioplasty and subsequent OCT to assess device/vessel apposition. The incidence of CM seen on OCT was assessed with a binary scoring system: 0-CM present; 1-CM absent. At 30 days, DSA was acquired to assess aneurysm healing. Aneurysm healing on terminal DSA was measured using a previously developed 5 point scale, with a score of 3 or 4 considered a positive outcome. RESULTS: All animals were grouped into a single cohort for analysis as no difference in the rate of CM or healing was seen in the four treatment groups. Significant interaction between the absence of CM and a positive outcome was confirmed by Fisher exact test (P=0.0034). Angioplasty was shown to treat 33% of the cases of CM seen at implant, and these treated cases overwhelmingly had a positive outcome (P<0.001). CONCLUSION: The use of OCT to assess CM of flow diverters has been shown to be predictive of the 30 day healing rate of an animal model of aneurysms.


Asunto(s)
Modelos Animales de Enfermedad , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Stents Metálicos Autoexpandibles/tendencias , Tomografía de Coherencia Óptica/métodos , Animales , Prótesis Vascular/efectos adversos , Prótesis Vascular/tendencias , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Masculino , Conejos , Stents Metálicos Autoexpandibles/efectos adversos , Factores de Tiempo
18.
J Neurointerv Surg ; 10(4): 406-411, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28689183

RESUMEN

PURPOSE: Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). METHODS: Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. RESULTS: Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p<0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95% CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). CONCLUSION: In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device.


Asunto(s)
Aneurisma Intracraneal/diagnóstico por imagen , Stents Metálicos Autoexpandibles/efectos adversos , Trombosis/diagnóstico por imagen , Angioplastia/métodos , Animales , Colina/administración & dosificación , Femenino , Aneurisma Intracraneal/inducido químicamente , Aneurisma Intracraneal/terapia , Elastasa Pancreática/toxicidad , Fósforo/administración & dosificación , Conejos , Distribución Aleatoria , Stents Metálicos Autoexpandibles/tendencias , Stents , Propiedades de Superficie/efectos de los fármacos , Trombosis/inducido químicamente , Trombosis/terapia , Tomografía de Coherencia Óptica/métodos
19.
Oper Neurosurg (Hagerstown) ; 14(4): 351-358, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28521024

RESUMEN

BACKGROUND: Pericallosal artery aneurysm treatment may be challenging using traditional endovascular techniques. OBJECTIVE: To demonstrate the feasibility, efficacy, and safety of endovascular treatment of pericallosal artery aneurysm using flow diverters. METHODS: We performed a retrospective review of our institutional database from July 2013 through July 2016 and identified 7 subjects with a pericallosal artery aneurysm treated with the Pipeline embolization device (ev3 Neurovascular, Medtronic, Dublin, Ireland) and at least 1 follow-up angiogram. Technical feasibility, procedural complication, angiographic results, and clinical outcome were evaluated. RESULTS: Placement of the Pipeline embolization device was successful in all cases without evidence of procedural complication. Five out of 7 subjects showed a complete aneurysm occlusion at 6- to 12-mo follow-up angiogram. The 2 subjects with persistent aneurysm filling showed decreased aneurysm sac volume on follow-up angiograms (96% and 60%). There was no evidence of in-implant stenosis or intimal hyperplasia. No thromboembolic or hemorrhagic complications were seen during the follow-up period. Only 1 patient had a transient change in Modified Rankin scale score from baseline as a result of different unrelated procedure. CONCLUSION: Our preliminary results demonstrate feasibility of the use of flow diverter stent for treatment of aneurysms of the pericallosal artery with rate of aneurysm occlusion comparable to literature and without evidence of increased procedural or short-term morbidity. A long-term and larger cohort study is needed to validate our findings.


Asunto(s)
Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Stents , Anciano , Angiografía Cerebral , Cuerpo Calloso/irrigación sanguínea , Diseño de Equipo , Femenino , Humanos , Imagenología Tridimensional , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
20.
Interv Neurol ; 6(3-4): 268-276, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29118805

RESUMEN

BACKGROUND: Over the course of the thrombectomy procedure, clot fragments may become dislodged and lead to downstream emboli due to manipulation of an endovascular device. The EmboTrap thrombectomy system features an inner stent channel with an outer stent trap design that may potentially reduce the risk of distal clot fragmentation during clot removal. We tested the hypothesis that distal emboli to both the same and new territory generated during mechanical thrombectomy are a function of device design. METHODS: EmboTrap and Solitaire thrombectomy were conducted in an in vitro model system that mimicked a middle-cerebral artery (MCA) occlusion within a complete circle of Willis vascular replica and a contrast-enhanced clot analog. Emboli generated during the procedure with a size >1,000 µm were collected and measured with calipers. The Coulter principle was used to characterize emboli with a size between 200 and 1,000 µm. RESULTS: EmboTrap thrombectomy resulted in a significant reduction in the risk of large emboli (>1,000 µm) formation as compared to first-generation stent retriever thrombectomy (p = 0.031, Fisher exact test). The majority of emboli >1,000 µm (∼80%) were found in the MCA, regardless of device type. There was no significant difference between the EmboTrap and Solitaire in 200 to 1,000 µm emboli formation (p = 0.89, Mann-Whitney test). When combining all emboli in the most dangerous range (>200 µm), EmboTrap offered a size reduction of emboli (p = 0.022). CONCLUSION: The risk of distal embolization can be altered with improved stent retriever design. When encountering fragment-prone clots, EmboTrap thrombectomy may lower the risk of distal embolization.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...