1.
Materials (Basel) ; 17(10)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38793413

RESUMEN

The resistance of nickel-titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel-titanium rotary systems, while correlating the results with the instruments' geometric and metallurgical characteristics. A total of 250 new instruments (sizes S1/A1, S2/A2, F1/B1, F2/B2, F3/B3) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-Files systems underwent mechanical testing. Prior to experimental procedures, all instruments were meticulously inspected to identify irregularities that could affect the investigation. Using a stereomicroscope, design characteristics such as the number of spirals, length, spirals per millimeter, and average helical angle of the active blade were determined. The surface finishing characteristics of the instruments were examined using a scanning electron microscope. Differential scanning calorimetry was employed to establish the instruments' phase transformation temperatures, while energy-dispersive X-ray spectroscopy was utilized to analyze the elemental composition of the alloy. The instruments were subjected to cyclic fatigue testing within a stainless steel non-tapered artificial canal featuring a 6 mm radius and 86 degrees of curvature. Appropriate statistical tests were applied to compare groups, considering a significance level of 0.05. The assessed design characteristics varied depending on the instrument type. The least irregular surface finishing was observed in U-Files and Premium Taper Gold files, while the most irregular surface was noted in Go-Taper Flex. All instruments exhibited near-equiatomic proportions of nickel and titanium elements, whereas ProTaper Universal and U-Files instruments demonstrated lower phase transformation temperatures compared to their counterparts. Larger-sized instruments, as well as ProTaper Universal and U-Files, tended to display lower cyclic fatigue strength results. Overall, the design, metallurgical, and cyclic fatigue outcomes varied among instruments and systems. Understanding these outcomes may assist clinicians in making more informed decisions regarding instrument selection.

2.
Dent J (Basel) ; 12(4)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38668010

RESUMEN

Small-sized stainless steel hand files are conventionally employed in root canal treatment procedures for canal scouting and for glide path establishment, owing to their superior flexibility and proficiency in navigating confined spaces. Given the diversity of brands available in the market, there exists potential variability in their physical characteristics, thereby influencing clinical performance. Consequently, this study aims to conduct a comparative analysis of the design, metallurgy, and mechanical characteristics among seven stainless steel hand file brands across ISO sizes 06, 08, and 10. A total of 315 new 25 mm length stainless steel hand files with apical sizes of 0.06, 0.08, and 0.10 from seven distinct brands were included in the study. A meticulous inspection of all instruments was undertaken to identify any structural deformations that might render them ineligible for the study. The design inspection involved the random selection of instruments from each group, which were examined under various microscopes, including a dental operating microscope, optical microscope, and scanning electron microscope. Furthermore, two instruments from each group underwent energy-dispersive X-ray spectroscopy analysis for elemental composition documentation. Mechanical tests were conducted to evaluate the instruments' resistance to lateral deformation (buckling) and their microhardness. Statistical analysis was executed using the nonparametric Mood's median test, with a predetermined significance level of 0.05. Regarding the instruments design, all files exhibited an active blade length ranging from 16 to 17 mm. However, variations were observed in the number of spirals, tip designs, and sizes, with the API K-File notably larger in sizes 0.06 and 0.08 compared to the other instruments. Despite uniform elements composition, differences in geometric features and mechanical properties were evident. Concerning buckling strength, the API K-File demonstrated superior performance across all tested sizes, while the Dentsply ReadySteel, SybronEndo, and Mani K-Files exhibited lower results (p < 0.05). In microhardness assessments, both the API and Oro K-Files displayed the lowest outcomes, with medians of 531 HVN and 532 HVN, respectively, whereas the SybronEndo K-File exhibited the highest microhardness (657 HVN). Despite similar metallurgical composition, the observed distinctions in geometric features and mechanical properties underscore the impact of the manufacturing process on the characteristics of glide path stainless steel endodontic files. These disparities may ultimately influence their clinical performance.

3.
Dent J (Basel) ; 12(2)2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38392233

RESUMEN

To establish a glide path, smaller files (up to size 0.15) with tapers of 2% are commonly used as pathfinding files. They pre-shape the root canal space before transitioning to larger taper endodontic instruments, aiming to prevent procedural errors. This study aimed to compare the design, metal wire composition, and mechanical characteristics of seven different ISO size 15 stainless-steel hand files (K-File and C-File+). Ninety-one new stainless-steel ISO 15 K-files were mechanically tested. All files were inspected for deformations before the assessment. Dental operating microscope, scanning electron microscope (SEM), and optical microscope analyses were conducted on four randomly selected instruments from each group, and two instruments per group underwent an energy-dispersive X-ray spectroscopy (EDS) analysis. Buckling mechanical tests were performed using an Instron universal testing machine, and microhardness was assessed using a Vickers hardness tester. The statistical analysis employed the nonparametric Mood's median test, with a significance level set at 0.05. The instrument design analysis unveiled variations in the active blade area length and the number of spirals, while maintaining consistent cross-sections and symmetrical blades. Distinct tip geometries and surface irregularities were observed. While the energy-dispersive X-ray spectroscopy confirmed similar compositions, the buckling strength and microhardness values exhibited variability across for all tested files. Notably, the Dentsply ReadySteel C-File+ recorded the highest buckling value (2.10 N), and the Dentsply ReadySteel K-File exhibited the lowest (1.00 N) (p < 0.05). Moreover, the Dentsply ReadySteel K-File recorded the highest microhardness value (703 HVN), while the SybronEndo Triple-Flex had the lowest (549 HVN) (p < 0.05). While similarities in cross-section design and metal wire composition were noted among the files, variations in the number of spirals and mechanical performance were also observed. Thus, all of these factors should be considered when selecting suitable files for an efficient root canal treatment.

4.
Int Endod J ; 57(5): 601-616, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38376108

RESUMEN

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Asunto(s)
Instrumentos Dentales , Titanio , Estudios Transversales , Diseño de Equipo , Ensayo de Materiales , Estrés Mecánico , Titanio/química , Preparación del Conducto Radicular , Metalurgia
5.
Int J Prosthodont ; 37(1): 109, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38381990

RESUMEN

PURPOSE: To evaluate the in vitro accuracy of impressions obtained with two silicone and corresponding stone models using two laboratory scanners. MATERIALS AND METHODS: A master model with synthetic resin teeth with two single-unit crown preparations was created and scanned using a 12-megapixel scanner. Five conventional impressions of the physical model were prepared with different silicone impression systems (Zhermack and Coltene) using the double-mix technique and poured with gypsum. The impressions and stone models obtained were scanned using two extraoral scanning systems (Identica T500, Medit; S600 ARTI, Zirkonzahn). All best-fit superimpositions of the teeth areas were conducted between the master model and the scans of the impressions and models obtained with the two scanners. A P < .05 level was considered significant. RESULTS: The Identica T500 Medit scanner showed an accuracy of 102.34 (89.67, 115.01) µm for Coltene silicone and 79.51 (67.82, 91.21) µm for Zhermack silicone, while the S600 ARTI Zirkonzhan scanner presented 110.79 (98.24, 123.33) µm and 91.91 (81.29, 102.54) µm, respectively, with significant differences between scanners for Zhermack silicone (P = .008) and for the corresponding stone models (P = .002). Zhermack silicone presented overall discrepancies lower than Coltene silicone, with statistically significant differences in both scanners analyzed (P < .001; P = .017). However, the discrepancies found were within clinically acceptable values. With the Zirkonzahn scanner, discrepancies found in the Zhermack impressions were lower than in the corresponding stone models (P < .001). CONCLUSIONS: The direct digitization of silicone impressions with laboratory scanners presented comparable results to conventional techniques with stone models.


Asunto(s)
Imagenología Tridimensional , Diente , Siliconas , Técnica de Impresión Dental , Diseño Asistido por Computadora , Materiales de Impresión Dental
6.
J Prosthet Dent ; 131(3): 479-486, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36890000

RESUMEN

STATEMENT OF PROBLEM: The fit of removable partial denture frameworks should be assessed to optimize clinical adaptation. Potential discrepancies between framework and supporting structures are typically precisely measured with negative subtracts and high-resolution equipment. The growth of computer-aided engineering technology allows the development of new methods for the direct evaluation of discrepancies. However, how the methods compare is unclear. PURPOSE: The purpose of this in vitro study was to compare 2 digital methods of fit assessment based on direct digital superimposition and microcomputed tomography indirect analysis. MATERIAL AND METHODS: Twelve cobalt chromium removable partial denture frameworks were fabricated by conventional lost-wax casting or additive manufacturing techniques. The thickness of the gap between occlusal rests and respective definitive cast rest seats (n=34) was evaluated by using 2 different digital methods. Silicone elastomer impressions of the gaps were obtained, and microcomputed tomography measurements were used as controls for validation purposes. Digitization of the framework, the respective definitive cast, and the combination was followed by digital superimposition and direct measurements with the Geomagic Control X software program. Because normality and homogeneity of variance were not verified (Shapiro-Wilk and Levene tests, P<.05), the data were analyzed with Wilcoxon signed rank and Spearman correlation tests (α=.05). RESULTS: The thicknesses measured by microcomputed tomography (median=242 µm) and digital superimposition (median=236 µm) did not reveal statistically significant differences (P=.180). A positive correlation (ρ=0.612) was detected between the 2 methods of assessing fit. CONCLUSIONS: The frameworks presented median gap thicknesses under the limit of clinical acceptability without differences between the proposed methods. The digital superimposition method was determined to be as acceptable as the high-resolution microcomputed tomography method for assessing removable partial denture framework fit.


Asunto(s)
Dentadura Parcial Removible , Microtomografía por Rayos X , Proyectos de Investigación , Cromo , Cobalto
7.
Int J Prosthodont ; 36(5): 649, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37921676

RESUMEN

PURPOSE: To compare the CIE L*a*b* values of two different dental shade guides using two shade-matching spectrophotometers. MATERIALS AND METHODS: SpectroShade Micro (SS) and Easyshade (ES) (VITA Zahnfabrik) were tested. One calibrated operator performed 30 measurements of each tab from three batches of the two guides, VITA Classical (VC) and VITA 3D Shade Master (VM). Receiver operating characteristic (ROC) curves and intraclass coefficients (ICC) between the different batches were calculated. Results were given as mean and SD of the L*a*b* values and the respective color differences according to the CIEDE 2000 formula (ΔE00) for each of the shade tabs in the two spectrophotometers and then analyzed with independent student t test (α = .05). RESULTS: A total of 1,440 and 2,610 measurements for VC and VM, respectively, were performed per spectrophotometer. There were statistically significant differences between the two devices for all L*a*b* values, with the exception of: L* for 3R1.5; a* for 2R1.5, 3L1.5, 2L2.5, 3M2, 3L2.5, 4L1.5, and 4L2.5; and b* for D3, 1M2, and 3M2. When assessing the same shade guide, differences in ΔE00 were detected between devices above the acceptability threshold (AT) (ΔE00 ≥ 1.8) for all shade tabs except for VC (C1, C2, D3, A3.5, C3, and A4) and VM (4M1, 3R2.5, 4L2.5, and 4M3). The overall mean of the interdevice ΔE00 was 2.2 ± 1.0 for VC and 2.5 ± 1.0 for VM. CONCLUSIONS: The two dental spectrophotometers presented high ICC and ROC values, which validates their indication as auxiliary tools. However, there are discrepancies in the hues D (VC) and R (VM) with interdevice variability when evaluated for the L*a*b* component. Int J Prosthodont 2023;36:e38-e52.


Asunto(s)
Diseño de Prótesis Dental , Coloración de Prótesis , Color , Espectrofotometría , Colorimetría
8.
Biomimetics (Basel) ; 8(5)2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37754135

RESUMEN

Colour assessment using digital methods can yield varying results, and it is important for clinicians to recognize the potential variability intra and inter-device. This study aimed to compare the L*a*b* values of VITA Classical (VC) and VITA Toothguide 3D-MASTER (VM) guides using two methods, SpectroShade (SS) and eLAB. Thirty-four measurements per tab were performed by a single operator across three batches of each guide. Intraclass correlation coefficients (ICC) between batches were calculated. Values <0.5, 0.5-0.75, 0.75-0.9, and >0.90 were classified as poor, moderate, good, and excellent reliability, respectively. Results were reported as mean and standard deviation of the L*a*b* values and respective colour differences (ΔE00) for each tab and method. Statistical analyses were performed with an independent t-test, α = 0.05. ICC values between batches were excellent for all L*a*b*, except for a* component in eLAB. There were statistically significant differences between methods in most L*a*b* values. The intra-device mean ΔE00 was 0.5 ± 0.6 for VC, 0.5 ± 0.8 for VM in SS, 1.1 ± 0.8 for VC, 1.1 ± 0.9 for VM in eLAB. The mean ΔE00 inter-device was 4.9 ± 1.7 for VC, 5.0 ± 1.7 for VM. Both methods demonstrated good internal consistency, with high ICC values and low intra-device colour differences, but exhibited high variability between methods, higher for a* the component.

9.
Int Endod J ; 56(11): 1412-1428, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37698946

RESUMEN

AIM: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.


Asunto(s)
Instrumentos Dentales , Calor , Diseño de Equipo , Estrés Mecánico , Preparación del Conducto Radicular , Titanio/química , Metalurgia , Oro , Ensayo de Materiales
10.
J Prosthet Dent ; 2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37620183

RESUMEN

STATEMENT OF PROBLEM: Digital methods such as intraoral scanners for recording the location of implants supporting complete arch prostheses have limitations. Photogrammetry devices should be able to digitize implant positions accurately, but standardized comparisons between different digital acquisition methods are lacking. PURPOSE: The purpose of this in vitro study was to compare the repeatability of different digital acquisition methods for complete arch prostheses supported by 6 and 4 implants. MATERIAL AND METHODS: A master cast was created with 6 and 4 dental implants with multiunit abutments to obtain the master digital casts. The evaluated devices were the industrial high-resolution 12-megapixel scanner (reference) Atos Compact Scan 12M (GOM), the laboratory scanners D2000 (3Shape A/S) and S900 Arti (Zirkonzahn), the photogrammetry devices iCam (iMetric4D) and PIC (PIC Dental), and the intraoral scanners TRIOS 3 (3Shape A/S) and iTero Element 5D (Align Technology). The resulting files were imported to a computer-aided design software program (exocad GmbH) to obtain the implant replicas as standard tessellation language (STL) files. These files were imported into a software program (Geomagic Control X) and superimposed per group through the best-fit algorithm to determine repeatability, defined as the closeness of agreement between each group's scanned results as root mean square (RMS) values. The normality of distribution was tested by the Shapiro-Wilk normality test, and the Kruskal-Wallis test with adjustment with the Bonferroni correction method was used accordingly (α=.05). RESULTS: The repeatability means and 95% confidence intervals for the 4 implant scans were: 1.07 µm (0.86; 1.29) for GOM, 2.05 µm (1.89; 2.21) for D2000, 3.61 µm (3.23; 3.99) for S900, 7.01 µm (6.11; 7.91) for iCam, 5.18 µm (4.6; 5.76) for PIC, 20.52 µm (18.33; 22.72) for TRIOS3, and 20.5 µm (17.37; 23.63) for iTero. Statistically significant differences were found between devices, except for iCam versus PIC, GOM versus S900, iCam versus D2000, PIC versus D2000, and TRIOS3 versus iTero. The repeatability means and 95% confidence intervals for the 6 implant groups were: 1.36 µm (1.08; 1.65) for GOM, 3.17 µm (3.01; 3.33) for D2000, 2.15 µm (2.04; 2.25) for S900, 8.67 µm (8.06; 9.28) for iCam, 13.88 µm (12.62; 15.14) for PIC, 40.32 µm (36.29; 44.36) for TRIOS3, and 38.86 µm (34.01; 43.71) for iTero. Statistically significant differences were detected between devices, except for S900 versus GOM, PIC versus iCam, and iTero versus TRIOS 3. CONCLUSIONS: The results suggest that photogrammetry could be a suitable alternative for recording implant locations of complete arch prostheses supported by 4 or 6 implants, with better repeatability than intraoral scanners. Increasing the number of implants decreased the repeatability of every device tested except the laboratory scanners.

11.
Materials (Basel) ; 16(16)2023 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-37629843

RESUMEN

Whitening products commonly utilize hydrogen peroxide (HP) as an active principle, which can penetrate dental tissues with potential side effects due to its low molecular weight. This study aimed to evaluate the HP diffusion of two in-office whitening products, namely 6% VivaStyle Paint On Plus (VS) and Opalescence Boost 40% (OP), in different tooth types. Additionally, the influence of the area of exposure, dental tissue thickness and pulp chamber volume was assessed. Each group consisted of eighteen intact anterior (A), premolar (PM) and molar (M) human teeth, and a positive pulpal pressure model was employed. The samples were analyzed using spectrophotometry, and results were expressed as the mean and 95% confidence interval. Statistical tests and linear regression models were appropriately applied at α = 5%. The total HP (µg) retrieved was as follows: VS-A, 1.333 [1.214, 1.452]; OP-A, 1.538 [1.457, 1.620]; VS-PM, 1.208 [1.123, 1.291]; OP-PM, 3.628 [3.401, 3.855]; VS-M, 2.560 [2.297, 2.823]; and OP-M, 4.197 [3.997, 4.396], with statistically significant differences in diffusion kinetics between whitening products for PM and M. Several HP concentrations attained a minimum cytotoxicity value of 2.22 µg/mL. The regression model shows that OP exposed the pulp chamber to 1.421 µg of HP more than that of VS. Different whitening products can cause cytotoxic HP concentrations in the pulp chamber, with a higher risk observed in molars.

12.
Materials (Basel) ; 16(10)2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37241263

RESUMEN

The nickel-titanium (NiTi) instruments' geometry plays an important role in their performance and behavior. The present assessment intends to validate and test the applicability of a 3D surface scanning method using a high-resolution laboratory-based optical scanner to create reliable virtual models of NiTi instruments. Sixteen instruments were scanned using a 12-megapixel optical 3D scanner, and methodological validation was performed by comparing quantitative and qualitative measurements of specific dimensions and identifying some geometric features of the 3D models with images obtained through scanning electron microscopy. Additionally, the reproducibility of the method was assessed by calculating 2D and 3D parameters of three different instruments twice. The quality of the 3D models created by two different optical scanners and a micro-CT device was compared. The 3D surface scanning method using the high-resolution laboratory-based optical scanner allowed for the creation of reliable and precise virtual models of different NiTi instruments with discrepancies varying from 0.0002 to 0.0182 mm. The reproducibility of measurements performed with this method was high, and the acquired virtual models were adequate for use in in silico experiments, as well as for commercial or educational purposes. The quality of the 3D model obtained using the high-resolution optical scanner was superior to that acquired by micro-CT technology. The ability to superimpose virtual models of scanned instruments and apply them in Finite Element Analysis and educational purposes was also demonstrated.

13.
Int Endod J ; 56(4): 530-542, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36508297

RESUMEN

AIM: To compare design, metallurgy and mechanical performance of the ProTaper (PT) Ultimate system with instruments of similar dimensions from the ProGlider, PT Gold and PT Universal systems. METHODOLOGY: New PT Ultimate instruments (n = 248) were compared with instruments of similar dimensions from ProGlider (n = 31), PT Gold (n = 155) and PT Universal (n = 155) systems regarding their number of spirals, helical angle, blade symmetry, tip geometry, surface finishing, nickel/titanium ratio, phase transformation temperatures and mechanical performance. One-way anova and nonparametric Mood's median tests were used for statistical comparison (α = 5%). RESULTS: All instruments had symmetrical blades without radial lands or flat sides, similar surface finishing and an almost equiatomic nickel/titanium ratio, whilst the number of spirals, helical angles and the tip geometry were different. PT Ultimate instruments showed 3 distinct heat treatments that matched with the colour of their metal wire. Slider and ProGlider instruments had similar R-phase start (Rs) and R-phase finish (Rf) temperatures. SX, F1, F2, F3 and Shaper instruments showed equivalent heat treatments (Rs ~45.6°C and Rf ~28.3°C) that were similar to their PT Gold counterparts (Rs ~47.9°C and Rf ~28.2°C), but completely distinct to the PT Universal ones (Rs ~16.2°C and Rf ~-18.2°C). Amongst the PT Ultimate instruments, the lowest maximum torques were observed in the SX (0.44 N cm), Slider (0.45 N cm) and Shaper (0.60 N cm) instruments, whilst the highest was noted in the FXL (4.90 N cm). PT Ultimate Slider and ProGlider had similar torsional (~0.40 N cm) and bending loads (~145.0 gf) (p = 1.000), whilst the other PT Ultimate instruments showed statistically significantly lower maximum torque, higher angle of rotation and lower bending load (higher flexibility) than their counterparts of the PT Universal and PT Gold systems. CONCLUSIONS: The PT Ultimate system comprises instruments with 3 distinct heat treatments that showed similar phase transformation temperatures to their heat-treated analogues. PT Ultimate instruments presented lower torsional strength and superior flexibility than their counterparts, whilst maximum torque, angle of rotation and bending loads progressively increased with their sizes.


Asunto(s)
Níquel , Titanio , Calor , Falla de Equipo , Ensayo de Materiales , Aleaciones Dentales , Preparación del Conducto Radicular , Diseño de Equipo , Torsión Mecánica
14.
Acta Med Port ; 36(2): 88-95, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35876725

RESUMEN

INTRODUCTION: Prader-Willi syndrome is a multisystemic genetic disorder associated with shorter adult height. Nowadays, all paediatric Prader-Willi syndrome patients are considered for growth hormone treatment. We present the experience of this treatment at a Portuguese paediatric endocrinology unit and intend to emphasise the importance of creating a follow-up national network of these patients. MATERIAL AND METHODS: Longitudinal, retrospective, analytical study of Prader-Willis syndrome patients using data between 1989 and 2021. Growth hormone therapy was offered to eligible patients. The analysis included all Prader-Willis syndrome patients, with a comparison between treated and untreated patients; a longitudinal analysis of patients receiving growth hormone therapy (baseline, 12 and 36 months of follow-up) was also carried out. The statistical analysis was carried out using STATA® v13.0. RESULTS: Out of 38 patients with Prader-William syndrome, 61% were male. The median age at diagnosis was four months and 61% received growth hormone therapy. The patients who reached adulthood, or 18 years old, had a median near-adult height, Z-score of -2.71, and their median body mass index indicated class 2 obesity, regardless of growth hormone therapy. Patients had a lower body mass index in the growth hormone group (35 vs 51 kg/m2, p < 0.042) near-adult height. CONCLUSION: This case series represents the first national study that included patients on growth hormone therapy after the National Health Service started supporting the treatment for Prader-Willi syndrome patients and supports its use, reinforcing the positive effects on growth and body mass index. Longer follow-up studies are needed to analyse the effect of growth hormone on patient metabolic profiling, body composition and cognitive level.


Introdução: A síndrome de Prader-Willi é uma doença genética multissistémica associada a baixa estatura. Atualmente, todos os doentes pediátricos com síndrome de Prader-Willi são candidatos a terapia com hormona do crescimento. Apresentamos a experiência desta terapêutica numa unidade de Endocrinologia Pediátrica portuguesa e realçamos a importância de criar uma base de dados nacional de seguimento destes doentes. Material e Métodos: Estudo longitudinal, retrospetivo e analítico de doentes com síndrome de Prader-Willi utilizando dados entre 1989 e 2021. A terapia com hormona de crescimento foi administrada aos doentes elegíveis. Foi realizada análise de todos os doentes com síndrome de Prader-Willi, com comparação doentes tratados/não tratados; foi também realizada uma análise longitudinal dos doentes sob hormona de crescimento (início/12/36 meses de seguimento). O tratamento estatístico foi realizado com recurso ao STATA® v13.0. Resultados: De um total de 38 doentes com síndrome de Prader-Willi, 61% eram do sexo masculino. Idade média de diagnóstico quatro meses e 61% sob hormona de crescimento. Os doentes que atingiram a idade adulta apresentaram um Z-score de mediana de estatura alvo de -2,71, e índice de massa corporal obesidade nível 2, independentemente da terapêutica com hormona de crescimento. Os doentes apresentaram um índice de massa corporal menor no grupo tratado com hormona de crescimento (35 vs 51 kg/m2, p < 0,042). Conclusão: Este estudo de série de casos de doentes com síndrome de Prader-Willi tratados com hormona de crescimento é pioneiro a nível nacional desde a comparticipação deste tratamento pelo Sistema Nacional de Saúde português e apoia esta terapêutica, reforçando os seus efeitos positivos no crescimento e índice de massa corporal. Serão necessários estudos com seguimento mais prolongado para analisar o seu efeito no perfil metabólico, composição corporal e cognição.


Asunto(s)
Hormona de Crecimiento Humana , Síndrome de Prader-Willi , Adolescente , Adulto , Niño , Femenino , Humanos , Masculino , Hormona del Crecimiento , Hormona de Crecimiento Humana/uso terapéutico , Portugal , Síndrome de Prader-Willi/tratamiento farmacológico , Síndrome de Prader-Willi/inducido químicamente , Síndrome de Prader-Willi/diagnóstico , Estudios Retrospectivos , Medicina Estatal
15.
Int J Prosthodont ; 2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36484678

RESUMEN

PURPOSE: To evaluate the in vitro accuracy of impressions obtained with two silicone and corresponding stone models using two laboratory scanners. MATERIAL AND METHODS: A master model with synthetic resin teeth with two single-unit crown preparations was created and scanned using a 12-MP scanner. Five conventional impressions of the physical model were prepared with different silicone impression systems (Zhermack and Coltene) using the double-mix technique and poured with gypsum. The impressions and stone models obtained were scanned by two extraoral scanning systems (Identica T500 Medit and S600 ARTI Zirkonzahn). All best-fit superimpositions of the teeth areas were conducted between the master model and the scans of the impressions and models obtained with the two scanners. A P < .05 significance level was considered. RESULTS: The Identica T500 Medit scanner showed an accuracy of 102.34 (89.67, 115.01) µm for Coltene silicone and 79.51 (67.82, 91.21) µm for Zhermack silicone, while the S600 ARTI Zirkonzhan scanner presented 110.79 (98.24, 123.33) µm and 91.91 (81.29, 102.54) µm, respectively, with significant differences between scanners for Zhermack silicone (P = .008) and for the corresponding stone models (P = .002). Zhermack silicone presented overall discrepancies lower than Coltene silicone, with statistically significant differences in both scanners analyzed (P < .001; P = .017). However, the discrepancies found were within clinically acceptable values. With the Zirkonzahn scanner, discrepancies found in the Zhermack impressions were lower than in the corresponding stone models (P < .001). CONCLUSION: The direct digitalization of silicone impressions by laboratory scanners presented comparable results to conventional techniques with stone models.

16.
Med. oral patol. oral cir. bucal (Internet) ; 27(6): e525-e531, Nov. 2022. tab, graf
Artículo en Inglés | IBECS | ID: ibc-213107

RESUMEN

Background: The aim of this study was to validate and determine at pretest level the reliability of the Portuguese version of the Groningen radiotherapy-induced xerostomia questionnaire. Material and methods: This study employed 37 head and neck cancer patients. Each patient signed an informed consent and responded to the Portuguese version of the questionnaire in the form of an interview. This was repeated again after 2 weeks. A standard single question provided a validity check. Data were analyzed using Cronbach's α to test its reliability and total and interitem correlation, and intraclass correlation to determine its internal consistency and test-retest reliability. Construct validity supported by objective measurements as salivary secretion was also investigated. Significance was set at .05. Results: Cronbach's α was 0.91 and 0.89 for the first and second test administrations, respectively, which indicates that the internal consistency was excellent. The intraclass correlation coefficient value for the test-retest reliability was 0.70. The correlation between the total score of the questionnaire and standard single dry mouth question was 0.72 for the first round, indicating a good correlation. Conclusions: Demonstrating very good psychometric properties, the Portuguese version of the Groningen radiotherapy-induced xerostomia questionnaire is a valid tool and can be considered a reliable instrument to measure xerostomia in head and neck cancer patients. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Neoplasias de Cabeza y Cuello/radioterapia , Xerostomía/diagnóstico , Xerostomía/etiología , Estudios Transversales , Epidemiología Descriptiva , Encuestas y Cuestionarios , Portugal
17.
Clin Oral Investig ; 26(12): 7167-7177, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35976497

RESUMEN

OBJECTIVES: To evaluate bleaching efficacy and oral health-related quality of life (ORHQoL) of three bleaching systems with similar hydrogen peroxide (HP) concentration for up to 6 months post-treatment. MATERIALS AND METHODS: A randomized controlled trial was designed with three parallel groups: group A - in-office 6% HP paint-on varnish; group B - at-home 6% HP with adaptable tray; group C - at-home 16% carbamide peroxide with custom tray. At three different stages (baseline, after bleaching, and 6-month follow-up), ORHQoL was evaluated by the OHIP-14 questionnaire and tooth color of the upper canines and central incisors were measured by two shade guides and a spectrophotometer (measuring CIE L*a*b* with respective color/whiteness differences - ΔE00/ΔWID). Results were presented as mean and 95% confidence intervals and statistical tests were performed appropriately, considering a significance level of α = 0.05. RESULTS: All groups presented significant color differences (P < 0.05) between all stages, with ΔE00/ΔWID surpassing the perceptibility threshold in 98% cases, with group C's results being significantly (P < 0.05) higher when compared to other groups, although with significantly (P < 0.05) higher values of color relapse. Significative ORHQoL improvements (P < 0.05) were detected after bleaching in a global analysis with no differences between techniques. CONCLUSIONS: All techniques presented bleaching efficacy, color stability, and improvements in ORHQoL up to 6 months post-treatment. CLINICAL SIGNIFICANCE: Clinicians may consider both at-home and in-office bleaching techniques with 6% HP to attain long-lasting satisfactory clinical results while producing positive changes in ORHQoL.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Blanqueamiento de Dientes/métodos , Calidad de Vida , Peróxido de Carbamida , Peróxido de Hidrógeno , Ácido Hipocloroso , Urea , Color , Peróxidos
18.
Materials (Basel) ; 15(11)2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35683270

RESUMEN

A multimethod study was conducted to assess the differences between original (PG-OR) and counterfeit (PG-CF) ProGlider instruments regarding design, metallurgical features, and mechanical performance. Seventy PG-OR and PG-CF instruments (n = 35 per group) were evaluated regarding the number of spirals, helical angles, and measuring line position by stereomicroscopy, while blade symmetry, cross-section geometry, tip design, and surface were assessed by scanning electron microscopy. Energy-dispersive X-ray spectroscopy and differential scanning calorimetry were used to identify element ratio and phase transformation temperatures, while cyclic fatigue, torsional, and bending testing were employed to assess their mechanical performance. An unpaired t-test and nonparametric Mann−Whitney U test were used to compare instruments at a significance level of 5%. Similarities were observed in the number of spirals, helical angles, blade symmetry, cross-sectional geometries, and nickel−titanium ratios. Measuring lines were more reliable in the original instrument, while differences were noted in the geometry of the tips (sharper tip for the original and rounded for the counterfeit) and surface finishing with PG-CF presenting more surface irregularities. PG-OR showed significantly more time to fracture (118 s), a higher angle of rotation (440°), and a lower maximum bending load (146.3 gf) (p < 0.05) than PG-CF (p < 0.05); however, maximum torque was similar for both instruments (0.4 N.cm) (p > 0.05). Although the tested instruments had a similar design, the original ProGlider showed superior mechanical behavior. The results of counterfeit ProGlider instruments were unreliable and can be considered unsafe for glide path procedures.

19.
Dent J (Basel) ; 10(2)2022 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-35200255

RESUMEN

BACKGROUND: The aim of this study was to comprehensively evaluate the cyclic fatigue strength of ProGlider, Edge Glide Path, and R-Pilot instruments. METHODS: Sixty-three instruments were submitted to a multimethod evaluation. Their design was analyzed by stereomicroscopy and scanning electron microscopy, including the number of blades, helical angle means, cross-sectional design, surface finishing, and symmetry. Energy-dispersive X-ray spectroscopy was used determine the nickel/titanium elements ratio, and differential scanning calorimetry determined the instruments' phase transformation temperatures. The cyclic fatigue tests were conducted in an artificial canal with a 6 mm radius and 86 degrees of curvature. The Mood's median test and one-way ANOVA were used to determine differences, with the significance level set at 0.05. RESULTS: The ProGlider presented the highest number of blades (n = 21), while R-Pilot had the highest helical angles (26.4°). Differences were noted in the instruments' cross-sections and surface finishing. The ProGlider and R-Pilot showed some similarities regarding the phase transformation temperatures but differed from the Edge Glide Path. All alloys showed an almost equiatomic nickel/titanium ratio. The R-Pilot instruments showed a significantly higher (p < 0.05) time to fracture than both the other files. CONCLUSION: Reciprocating R-Pilot instruments showed a higher cyclic fatigue time to fracture than the ProGlider and Edge Glide Path rotary files.

20.
J Clin Med ; 11(3)2022 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-35160343

RESUMEN

BACKGROUND: Bone regeneration procedures represent a major challenge in oral surgery. This study aimed to evaluate a composite PRF/particulate xenograft in guided bone regeneration. METHODS: Edentulous patients with horizontal ridge deficiencies in the anterior maxilla and candidates to an immediate-loading full-arch rehabilitation were included. Horizontal linear measurements indicating bone gain were assessed from computer beam computer tomography (CBCT) scans obtained at pre-surgery, post-surgery, and the 12-month follow-up. Mean bone values were presented as mean ± 95% CI. Non-parametric tests were used as appropriate, and the effect size was calculated with Cohen's d repeated measures. RESULTS: Eighteen patients were rehabilitated with 72 implants. The mean horizontal bone width was 4.47 [4.13-4.80] mm pre-surgically, 9.25 [8.76-9.75] mm post-surgically, and 7.71 [7.28-8.14] mm 12 months after. CONCLUSIONS: PRF associated with a xenograft seems to promote an effective horizontal bone gain. Randomized clinical trials are needed to confirm the benefits of this surgical approach.