Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Acta Cardiol ; 77(2): 158-165, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34092183

RESUMEN

BACKGROUND: The comparative mid and long-term durability, including the rates of bioprosthetic valve failure (BVF) of the Sapien XT® and Sapien 3® transcatheter heart valve (THV) in patients with intermediate surgical risk has not been reported. METHODS: Consecutive intermediate-risk patients with severe aortic stenosis from the Mexican registry of transcatheter aortic valve replacement (TAVR) with Sapien® THVs were included. The primary endpoint was to compare the BVF rate between THVs at 2 years of follow-up. Secondary endpoints were comparisons of the composite of global mortality, cardiovascular mortality, and neurological events at 30 d and 24 months of follow-up. RESULTS: During 2014-2019, 115 (60 Sapien XT® and 55 Sapien 3®) patients met the inclusion criteria in five medical centres. The mean age was 77.3 ± 8.4 years. The average Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) was 5.6 ± 2.9. There was no statistically significant difference between the groups in BVF rate. At 30 d, overall, cardiovascular and non-cardiovascular mortality was 4.3%, 2.6%, and 1.7%, respectively. Neurological events rate was 1.73%. The mean long-term follow-up was 25.3 ± 14.2 months with an overall mortality of 9.56% but lower for the Sapien 3® group (15% vs. 3.6%, p=.037). The only independent predictor of composite mortality and neurological events that occurred in the long term was using a Sapien XT® [OR 1.6, CI 95%, 1.0-24.9; p=.049]. CONCLUSIONS: The BVF rate at 25 months of follow-up was similar with the XT and S3 systems. During this follow-up period, the major composite events of death from any cause and neurological events were significantly lower with the S3 system.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Puntaje de Propensión , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Expert Rev Cardiovasc Ther ; 19(8): 711-723, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34275408

RESUMEN

INTRODUCTION: Significant mitral regurgitation (MR) frequently coexists in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). These patients have worse clinical outcomes than those with non-significant MR, especially if MR persists after treatment of the aortic stenosis. The optimal treatment approach for this challenging high-risk population is not well defined. AREAS COVERED: This review aims to present the current literature on concomitant significant MR in the TAVR population, and to provide a comprehensive algorithmic approach for clinical decision-making in this challenging cohort of patients. EXPERT OPINION: Concomitant mitral and aortic valve disease is a complex clinical entity. An exhaustive and comprehensive assessment of patient's clinical characteristics and mitral valve anatomy and function is required in order to assess the surgical risk, predict the MR response after AVR and evaluate the feasibility of percutaneous MV treatment if necessary. Further developments in transcatheter techniques will expand the indications for double valve treatment in operable and inoperable patients with concomitant significant MR and aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA