Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Opt ; 57(30): 9032-9039, 2018 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-30461891

RESUMEN

Macromolecular crystallography often requires focused high-intensity x-ray beams for solving challenging protein structures from micrometer-sized crystals using current synchrotron radiation sources. The design of optical focusing schemes for hard x-rays showing high efficiency and flexibility in beam size is therefore continuously pursued. Here, we present an innovative solution based on a two-stage demagnification of the undulator source for photon energies from 6 keV to 19 keV, commissioned at the X10SA beamline of the Swiss Light Source, where a secondary source is imaged by two crossed silicon kinoform x-ray diffractive lenses with 75 nm outermost zone width. A source-size limited spot with a size of 4.8 µm×1.7 µm(h×v,FWHM) and flux of 7.5×1010 photons/s at 12.4 keV is demonstrated at the sample position.

2.
Sci Rep ; 7(1): 8849, 2017 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-28821805

RESUMEN

We have implemented and successfully tested an off-axis transmission Fresnel zone plate as spectral analyzer for resonant inelastic X-ray scattering (RIXS). The imaging capabilities of zone plates allow for advanced two-dimensional (2D) mapping applications. By varying the photon energy along a line focus on the sample, we were able to simultaneously record the emission spectra over a range of excitation energies. Moreover, by scanning a line focus across the sample in one dimension, we efficiently recorded RIXS spectra spatially resolved in 2D, increasing the throughput by two orders of magnitude. The presented scheme opens up a variety of novel measurements and efficient, ultra-fast time resolved investigations at X-ray Free-Electron Laser sources.

3.
Opt Express ; 25(14): 15624-15634, 2017 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-28789077

RESUMEN

We have implemented and successfully tested an off-axis transmission Fresnel zone plate as a novel type of analyzer optics for resonant inelastic x-ray scattering (RIXS). We achieved a spectral resolution of 64 meV at the nitrogen K-edge (E/dE = 6200), closely matching theoretical predictions. The fundamental advantage of transmission optics is the fact that it can provide stigmatic imaging properties. This opens up a variety of advanced RIXS configurations, such as efficient scanning RIXS, parallel detection for varying incident energy and time-resolved measurements.

4.
J Synchrotron Radiat ; 23(Pt 6): 1440-1446, 2016 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-27787250

RESUMEN

Photonic glass is a material class that can be used as photonic broadband reflectors, for example in the infrared regime as thermal barrier coating films. Photonic properties such as the reflectivity depend on the ordering and material packing fraction over the complete film thickness of up to 100 µm. Nanotomography allows acquiring these key parameters throughout the sample volume at the required resolution in a non-destructive way. By performing a nanotomography measurement at the PETRA III beamline P05 on a photonic glass film, the packing fraction throughout the complete sample thickness was analyzed. The results showed a packing fraction significantly smaller than the expected random close packing giving important information for improving the fabrication and processing methods of photonic glass material in the future.

5.
Opt Express ; 24(10): 10880-9, 2016 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-27409908

RESUMEN

The aperture of refractive X-ray lenses is limited by absorption and geometry. We introduce a specific simulation method to develop an aperture-optimized lens design for hard X-ray full field microscopy. The aperture-optimized lens, referred to as Taille-lens, allows for high spatial resolution as well as homogeneous image quality. This is achieved by the individual adaptation of the apertures of hundreds of lens elements of an X-ray imaging lens to the respective microscopy setup. For full field microscopy, the simulations result in lenses with both a large entrance and exit aperture and lens elements with smaller apertures in the middle of the lens.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA