1.
J Dent ; 145: 104939, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38521237

RESUMEN

OBJECTIVES: To measure the impact of superimposition methods and the designated comparison area on accuracy analyses of dentate models using an ISO-recommended 3-dimensional (3D) metrology-grade inspection software (Geomagic Control X; 3D Systems; Rock Hill, South Carolina; USA). MATERIALS AND METHODS: A dentate maxillary typodont scanned with a desktop scanner (E4; 3 Shape; Copenhagen; Denmark) and an intraoral scanner (Trios 4; 3 Shape; Copenhagen; Denmark) was used as reference. Eight groups were created based on the core features of each superimposition method: landmark-based alignment (G1); partial area-based alignment (G2); entire tooth area-based alignment (G3); double alignment combining landmark-based alignment with entire tooth area-based alignment (G4); double alignment combining partial area-based alignment with entire tooth area-based alignment (G5); initial automated quick pre-alignment (G6); initial automated precise pre-alignment (G7); and entire model area-based alignment (G8). Diverse variations of each alignment and two regions for accuracy analyses (teeth surface or full model surface) were tested, resulting in a total of thirty-two subgroups (n = 18). The alignment accuracy between experimental and reference meshes was quantified using root mean square (RMS) error as trueness and its repeatability as precision. The descriptive statistics, a factorial repeated measures analysis of variance (ANOVA) and a post hoc Tuckey multiple comparison tests were used to analyze the trueness, and precision (α = 0.05). RESULTS: A total of 576 superimpositions were performed. The unique partial area-based superimposition method demonstrated the least precise alignment and was the sole group to exhibit a significant difference (p<.001). Automated initial pre-alignments demonstrated similar accuracy to other superimposition methods (p>.05). Double alignments did not result in accuracy improvement (p>.05). The designated comparison area displayed differences in both trueness (p<.001) and precision (p<.001), leading to an overall discrepancy of 8 ± 4 µm between selecting the teeth surface or full model surface. CONCLUSIONS: The superimposition method choice within the tested software did not impact accuracy analyses, except when the alignment relies on a unique and reduced area, such as the palatal rugae, a single tooth, or three adjacent teeth on one side. CLINICAL SIGNIFICANCE: The superimposition method choice within the tested ISO-recommended 3D inspection software did not impact accuracy analyses.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Modelos Dentales , Programas Informáticos , Humanos , Imagenología Tridimensional/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Puntos Anatómicos de Referencia , Reproducibilidad de los Resultados , Maxilar/anatomía & histología , Diente/anatomía & histología , Diente/diagnóstico por imagen
2.
J Prosthet Dent ; 2022 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-36109260

RESUMEN

STATEMENT OF PROBLEM: The lack of consensus regarding a standardized set of outcome measurements and noncompliance with current reporting guidelines in clinical trials of tooth-supported fixed dental prostheses (FDPs) hamper interstudy comparability, compromise scientific evidence, and waste research effort and resources in prosthetic dentistry. PURPOSE: The primary objective of this systematic review was to identify all primary and secondary outcome measurements assessed in randomized controlled trials (RCTs) of tooth-supported FDPs. Secondary objectives were to assess their methodological quality by using the Cochrane Collaboration's risk of bias tool (RoB, v2.0) and their reporting quality by means of a standardized 16-item CONSORT assessment tool through published reports. MATERIAL AND METHODS: An electronic search was conducted in MEDLINE, EMBASE, and Cochrane library to identify all RCT-related articles published in the past 10 years. Differences in RoB were tested with the Pearson chi-square test, and those in CONSORT score with the Student t test. RESULTS: A total of 64 RCTs from 79 publications were deemed eligible. The diversity of outcome measures used in the field is apparent. Twenty percent of the included studies had a low RoB, 79% showed some concerns, and 1% had a high RoB. The mean ±standard deviation CONSORT compliance score was 22.56 ±3.17. Trials adhered to the CONSORT statement reported lower RoB than those that did not adhere (P<.001). RCTs with a low RoB reported more comprehensive adherence to CONSORT guidelines than those with some concerns (MD 4 [95% CI 1.52-6.48]; P=.004). CONCLUSIONS: A standardized core outcome reporting set in clinical research on tooth-supported FDPs remains evident. Adherence to the CONSORT statement continues to be low, with some RoB concerns that can be improved.

3.
J Prosthodont ; 27(8): 708-715, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28084028

RESUMEN

PURPOSE: To study whether the shades of the 3D-Master System were grouped and represented in the chromatic space according to the three-color coordinates of value, chroma, and hue. MATERIALS AND METHODS: Maxillary central incisor color was measured on tooth surfaces through the Easyshade Compact spectrophotometer using 1361 participants aged between 16 and 89. The natural (not bleached teeth) color of the middle thirds was registered in the 3D-Master System nomenclature and in the CIELCh system. Principal component analysis and cluster analysis were applied. RESULTS: 75 colors of the 3D-Master System were found. The statistical analysis revealed the existence of 5 cluster groups. The centroid, the average of the 75 samples, in relation to lightness (L*) was 74.64, 22.87 for chroma (C*), and 88.85 for hue (h*). All of the clusters, except cluster 3, showed significant statistical differences with the centroid for the three-color coordinates (p <0.001). CONCLUSIONS: The results of this study indicated that 75 shades in the 3D-Master System were grouped into 5 clusters following coordinates L*, C*, and h* resulting from the dental spectrophotometer Vita Easyshade compact. The shades that composed each cluster did not belong to the same lightness color dimension groups. There was no special uniform chromatic distribution among the colors of the 3D-Master System.


Asunto(s)
Coloración de Prótesis/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Prótesis Dental , Femenino , Humanos , Imagenología Tridimensional , Incisivo/anatomía & histología , Masculino , Persona de Mediana Edad , España , Espectrofotometría , Adulto Joven
4.
Int Dent J ; 65(5): 227-34, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26211806

RESUMEN

OBJECTIVES: To analyse natural tooth colour in the Spanish population according to the colour coordinates lightness (L*), chroma (C*), hue (h*), red-green axis (a*) and yellow-blue axis (b*) in order to quantify the correlation and changes of tooth colour with age and sex. METHODS: Natural tooth colour was measured in a sample of 1,361 Spanish participants of both sexes distributed within an age range of 16 to 89 years. The Easyshade Compact spectrophotometer was used and the CIELAB and CIELCh systems were followed. RESULTS: Pearson's bivariate correlations between age and colour coordinates were highly significant for L* (r=-0.674, P≤0.001), h* (r=-0.468, P≤0.001) and C* (r=0.417, P≤0.001). The correlation between age and colour coordinates was stronger for men than for women, for all colour coordinates. The results showed that C*, b* and a* increased by 0.60, 0.56 and 0.26 units/year on average, respectively, whereas L* and h* decreased progressively with age (by 0.60 units/year, on average), and colour differences increased in a systematic way as the gap between the ages being compared grew wider. CONCLUSIONS: The strongest correlation was found between age and L*, then between age and h* (both inverse relationships) and then between age and a*, C* and b* (direct relationships). In addition, a similar degree of change in the colour coordinates L*, C* and h* (of 0.60 units/year on average) was observed for natural tooth colour. Knowledge of the chromatic range of natural teeth may help to choose colour for the replacement of missing elements.


Asunto(s)
Envejecimiento/patología , Incisivo/anatomía & histología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Color , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores Sexuales , España , Espectrofotometría , Adulto Joven
5.
J Prosthet Dent ; 113(3): 185-90, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25453564

RESUMEN

STATEMENT OF PROBLEM: The 3D-Master System comprises 26 physical shade tabs and intermediate shades. Determining the relationship among all the groups of lightness, chroma, and hue of the 3D-Master System (Vita Zahnfabrik) and the L*, C*, and h* coordinates is important, because according to the manufacturer, 2 Toothguide 3D-Master shades need to be mixed in a 50:50 ratio to create an intermediate shade. PURPOSE: The purpose of the study was to relate the lightness, chroma, and hue groups of the 3D-Master System with the polar coordinates of the CIELAB chromatic space, L*, C*, and h*, and to quantify the shades tabs and intermediate shades of the 3D-Master System according to color coordinates. MATERIAL AND METHODS: The middle third of the facial surface of a natural maxillary central incisor was measured with an Easyshade Compact spectrophotometer (Vita Zahnfabrik) in 1361 Spanish participants aged between 16 and 89 years. Natural tooth color was recorded in the 3D-Master nomenclature and in the CIE L*, C*, and h* coordinates system. The program used for the present descriptive statistical analysis of the results was SAS 9.1.3. RESULTS: In the L* variable, the minimum was found at 47.0 and the maximum at 91.3. In the C* variable, the minimum was found at 5.9 and the maximum at 49.8, while for h*, the minimum was 67.5 degrees and the maximum 112.0 degrees. CONCLUSIONS: Despite the limitations of this study, the 3D-Master System was found to be arranged according to L*, C*, and h* coordinates in groups of lightness, chroma, and hue. The corresponding groups of lightness, chroma, and hue can be estimated on the basis of L*, C*, and h* coordinates.


Asunto(s)
Diseño de Prótesis Dental/instrumentación , Coloración de Prótesis/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Color , Percepción de Color/fisiología , Estudios Transversales , Diseño de Prótesis Dental/normas , Femenino , Humanos , Incisivo/anatomía & histología , Masculino , Persona de Mediana Edad , Coloración de Prótesis/normas , España , Espectrofotometría/instrumentación , Terminología como Asunto , Corona del Diente/anatomía & histología , Adulto Joven
6.
J Adv Prosthodont ; 7(6): 413-22, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26816571

RESUMEN

PURPOSE: To identify the most frequent natural tooth colors using the Easyshade Compact (Vita -Zahnfabrik) spectrophotometer on a sample of the Spanish population according to the 3D Master System. MATERIALS AND METHODS: The middle third of the facial surface of natural maxillary central incisors was measured with an Easyshade Compact spectrophotometer (Vita Zahnfabrik) in 1361 Caucasian Spanish participants aged between 16 and 89 years. Natural tooth color was recorded using the 3D Master System nomenclature. The program used for the present descriptive statistical analysis of the results was SAS 9.1.3. RESULTS: The results show that the most frequent dental color in the total sample studied is 3M1 (7.05%), followed by the intermediate shade 1M1.5 (6.91%) and 2L1.5 (6.02%). CONCLUSION: According to the research methodology used, and taking into account the limitations of this study, it can be proposed that the most frequent color among the Spanish population is 3M1; the most common lightness group is 2; the most frequent hue group according to the 3D Master System is M and the most frequent chroma group is 1.5.

7.
J Dent ; 42(6): 742-5, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24140995

RESUMEN

OBJECTIVES: The aim of this work was to assess the agreement between instrumental and visual colour matching. METHODS: Shade selection with the 3DMaster Toothguide (Vita-Zahnfabrik) was performed for 1361 maxillary central incisors and compared with the shade obtained with the EasyShade Compact (Vita-Zahnfabrik) spectrophotometer. RESULTS: We observed a greater correlation between the objective method and the subjective one in the colour dimension of lightness (Kappa 0.6587), followed by hue (Kappa 0.4337) and finally chroma (Kappa 0.3578). CONCLUSION: The colour dimension in which the greatest agreement is seen between the operator and the spectrophotometer is value or lightness. CLINICAL SIGNIFICANCE: This study reveals differences between the measurement of colour via spectrophotometry and the visual shade selection method. According to our results, there is better agreement in the value or lightness colour dimension, which is the most important one in the choice of tooth colour.


Asunto(s)
Percepción de Color/fisiología , Incisivo/anatomía & histología , Coloración de Prótesis/instrumentación , Espectrofotometría/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Color , Femenino , Humanos , Luz , Masculino , Maxilar , Persona de Mediana Edad , Coloración de Prótesis/normas , Espectrofotometría/normas , Adulto Joven
SELECCIÓN DE REFERENCIAS