Adv Lab Med ; 5(2): 189-196, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939205

RESUMEN

Objectives: Despite clinical guidelines do not recommend the use of point-of-care testing (POCT) glucometers for diagnostic purposes yet, the analytical performance is continuously improving. Thus, we evaluate the technical accuracy and clinical concordance of POCT glucometers during an oral glucose tolerance test (OGTT) in children for prediabetes and diabetes diagnosis in a comparison study. Methods: Pediatric patients with an OGTT indication who attended the Diabetes Unit between December 2020 and September 2021 were recruited for this prospective observational study. During the functional test, glycaemia was immediately measured in venous blood using two glucometers (unconnected and connected) and sent to the central laboratory. Results: The study included 98 patients. There was a high correlation between the glucometers and the central laboratory (Pearson correlation coefficient=0.912 and 0.950, for unconnected and connected glucometer, respectively). The median OGTT turnaround time (TAT) was significantly decreased (connected glucometer: 2.02 h [interquartile range, 2.00-2.07], central laboratory: 11.63 h [6.09-25.80]), with similar overall cost. The diagnostic concordance between connected glucometer and the central laboratory was 71.1 % (95 % confidence interval (CI) 61.5-79.2). The clinical decision would have been the same in the 92.8 % of the cases, but treatment would have not been indicated in 4 patients (4.1 %). Conclusions: POCT glucometers have demonstrated a high correlation and an acceptable diagnostic concordance with the central laboratory during an OGTT, as well the connected device offers a significant decrease in TAT, without increasing costs. However, as severe clinical impact could happen, POCT glucometers may not be used for diagnosis yet.

3.
Clin Chim Acta ; 557: 117897, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38570026

RESUMEN

BACKGROUND AND AIMS: Small-dense-low-density-lipoprotein cholesterol (sdLDL-C) is proatherogenic and not commonly measured. The aims were to evaluate capillary blood and its stability for sdLDL-C measurement and measure sdLDL-C in patients with metabolic syndrome (MS). METHODS: 182 patients were studied (49 with MS). sdLDL-C was measured by electrophoresis (LipoPrint®), direct measurement (Roche Diagnostics) and Sampson equation. Intima-media thickness (IMT) and presence of atheroma was evaluated. sdLDL-C was compared in paired venous and capillary blood according to CLSI-EP09c (n = 40). sdLDL-C stability was studied after 24 h at room temperature (RT). RESULTS: sdLDL-C in capillary blood and venous blood showed agreement with the direct measurement (bias: 4.17 mg/dL, LOA 95 %:-5.66; 13.99) and estimation (bias:8.12 mg/dL, LOA 95 %:-8.59; 24.82). sdLDL-C is stable in capillary blood for 24 h at RT. The electrophoretic method yielded lower (p < 0.05) sdLDL-C than the equation or direct measurement. Patients with MS had (p < 0.05) higher sdLDL-C (%) than patients without MS. Patients with atheroma plaques had higher sdLDL-C (p < 0.05). Estimated sdLDL-C correlated with IMT (r = 0.259, p < 0.001). CONCLUSIONS: Capillary blood is an alternative to venous blood for sdLDL-C measurement and is stable for 24 h after collection. Estimated and directly measured sdLDL-C associate with the MS being accessible tools for cardiovascular risk assessment.


Asunto(s)
Síndrome Metabólico , Placa Aterosclerótica , Humanos , Grosor Intima-Media Carotídeo , Placa Aterosclerótica/diagnóstico por imagen , LDL-Colesterol , Medición de Riesgo , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...