1.
J Med Imaging (Bellingham) ; 11(2): 024006, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38525293

RESUMEN

Purpose: X-ray scatter significantly affects the image quality of cone beam computed tomography (CBCT). Although convolutional neural networks (CNNs) have shown promise in correcting x-ray scatter, their effectiveness is hindered by two main challenges: the necessity for extensive datasets and the uncertainty regarding model generalizability. This study introduces a task-based paradigm to overcome these obstacles, enhancing the application of CNNs in scatter correction. Approach: Using a CNN with U-net architecture, the proposed methodology employs a two-stage training process for scatter correction in CBCT scans. Initially, the CNN is pre-trained on approximately 4000 image pairs from geometric phantom projections, then fine-tuned using transfer learning (TL) on 250 image pairs of anthropomorphic projections, enabling task-specific adaptations with minimal data. 2D scatter ratio (SR) maps from projection data were considered as CNN targets, and such maps were used to perform the scatter prediction. The fine-tuning process for specific imaging tasks, like head and neck imaging, involved simulating scans of an anthropomorphic phantom and pre-processing the data for CNN retraining. Results: For the pre-training stage, it was observed that SR predictions were quite accurate (SSIM≥0.9). The accuracy of SR predictions was further improved after TL, with a relatively short retraining time (≈70 times faster than pre-training) and using considerably fewer samples compared to the pre-training dataset (≈12 times smaller). Conclusions: A fast and low-cost methodology to generate task-specific CNN for scatter correction in CBCT was developed. CNN models trained with the proposed methodology were successful to correct x-ray scatter in anthropomorphic structures, unknown to the network, for simulated data.

2.
PLoS One ; 19(3): e0297829, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38427663

RESUMEN

Positron Emission Mammography (PEM) is a valuable molecular imaging technique for breast studies using pharmaceuticals labeled with positron emitters and dual-panel detectors. PEM scanners normally use large scintillation crystals coupled to sensitive photodetectors. Multiple interactions of the 511 keV annihilation photons in the crystals can result in event mispositioning leading to a negative impact in radiopharmaceutical uptake quantification. In this work, we report the study of crystal scatter effects of a large-area dual-panel PEM system designed with either monolithic or pixelated lutetium yttrium orthosilicate (LYSO) crystals using the Monte Carlo simulation platform GATE. The results show that only a relatively small fraction of coincidences (~20%) arise from events where both coincidence photons undergo single interactions (mostly through photoelectric absorption) in the crystals. Most of the coincidences are events where at least one of the annihilation photons undergoes a chain of Compton scatterings: approximately 79% end up in photoelectric absorption while the rest (<1%) escape the detector. Mean positioning errors, calculated as the distance between first hit and energy weighted (assigned) positions of interaction, were 1.70 mm and 1.92 mm for the monolithic and pixelated crystals, respectively. Reconstructed spatial resolution quantification with a miniDerenzo phantom and a list mode iterative reconstruction algorithm shows that, for both crystal types, 2 mm diameter hot rods were resolved, indicating a relatively small effect in spatial resolution. A drastic reduction in peak-to-valley ratios for the same hot-rod diameters was observed, up to a factor of 14 for the monolithic crystals and 7.5 for the pixelated ones.


Asunto(s)
Electrones , Lutecio , Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Silicatos/química , Mamografía , Fotones
3.
J Biomech ; 145: 111354, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36335825

RESUMEN

Aerobic training (AT) is indicated in type 2 diabetes mellitus (T2DM) to control hyperglycaemia and inflammation. AT improves bone microarchitecture and resistance to fracture. The intensity of AT and the mechanisms that lead to the improvement in bone quality are still unknown. Using a mouse model of T2DM, we evaluated the effects of two intensities of forced AT. We divided mice into: sedentary (SED), T2DM-SED, low runners (LOW), T2DM-LOW, high runners (HIGH) and T2DM-HIGH. The AT for low was 8 m/minute (m/min); 5° slope or high 18 m/min; 15° slope for 2 months. We measured metabolic parameters, the serum cytokines concentration, lipocalin-2 (LCN-2) and adiponectin; and the tibial concentrations of LCN-2, tumour necrosis factor alpha (TNF-α) and protein carbonylation (CO). We evaluated femur morphometry and biomechanical properties. We performed multiple correlation analysis. The T2DM-LOW versus T2DM-SED group, shown an increase of interleukin (IL)-10 (417 ± 90 vs 102 ± 25 pg/mL) and improved trabecular bone (BV/TV: 31.8 ± 2.3 vs 19.25 ± 1.4%; Tb.Sp.: 1.62 ± 0.02 vs 2.0 ± 0.07 mm), by a decrease bone CO (3.4 ± 0.1 vs 6.0 ± 0.5 nmol/mg), bone TNF-α (84 ± 4 vs 239 ± 13 pg/mL) and LCN-2 (2887 ± 23 vs 3418 ± 105 pg/mL). The T2DM-HIGH versus T2DM-SED group showed a greater hypoglycaemic effect (228 ± 10 vs 408 ± 5 mg/dL), with improved cortical bone density (0.26 ± 0.012 vs 0.21 ± 0.007 mm) and fracture resistance (102 ± 8 vs 78 ± 5 MPa), by a reduction of bone TNF-α (77 ± 34 vs 239 ± 13 pg/mL); LCN-2 (2768 ± 20 vs 3418 ± 105 pg/mL) and CO (4.8 ± 0.5 vs 6.0 ± 0.5 nmol/mg). In conclusion, AT improves bone morphometry and biomechanical properties by reducing the bone inflammatory microenvironment.


Asunto(s)
Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/terapia , Factor de Necrosis Tumoral alfa , Huesos
4.
J Biomech ; 135: 111035, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35298960

RESUMEN

Exercise encourages active and healthy aging, maintaining functional and physical capabilities. This study aimed to assess the effects of a long-term moderate aerobic exercise protocol on bone microarchitecture and fragility associated with chronic inflammation and oxidative stress in aging. Male BALB/c mice (n = 10 per group) underwent a moderate exercise protocol from 13 weeks to 27 (adulthood age) or 108 weeks of age (elderly age) and were then sacrificed. Age-match sedentary mice were included as a control group. Serum cortisol concentrations were determined by chemiluminescent immunoassay, C-reactive protein (CRP) by a turbidimetric assay, advanced glycation end-products (AGEs) and malondialdehyde (MDA) by fluorescent spectroscopy, and total glutathione (GSH) by colorimetric method. The right femur was dissected formorphometric and densitometricanalysis bycomputerized microtomography (µCT),and biomechanical properties were assessed usinga three-point bending device. Musclefrom the same extremitywas obtained to determine relative mRNA expression ofpro-inflammatory cytokines (TNF-α and IL-6) by RT-qPCR.Statistical differences were evaluated by two-way ANOVA and Holm-Sidak method post hoc with P < 0.05. In elderly mice, moderate exercise increased glutathione levels and microarchitecture complexity but decreased bone fragility and oxidative stress markers, cortisol, and pro-inflammatory cytokines. In conclusion, these results suggest a strong link between a pro-inflammatory state and age-conditioned oxidative stress on bone quality. Thus, on a human scale, moderate aerobic exercise may improve bone quality during aging.


Asunto(s)
Hidrocortisona , Estrés Oxidativo , Animales , Citocinas/metabolismo , Glutatión/metabolismo , Glutatión/farmacología , Hidrocortisona/farmacología , Masculino , Ratones , Ratones Endogámicos BALB C
5.
Phys Med ; 81: 215-226, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33482439

RESUMEN

In this work the scintillation energy spectra originating from the background radioactivity from polished monolithic lutetium yttrium oxyorthosilicate coupled to position-sensitive silicon photomultipliers (SiPM) was studied using the open source Monte Carlo simulation package ANTS2. Two crystal sizes, fully and partially covering the photosensor area, three surface crystal wrappings (black, specular or diffuse) and the full signal formation process in the photosensor were considered. The simulation results were validated with experimental data acquired under the same geometric and detector operating conditions. In all cases ANTS2 simulated spectra have very good agreement with experimental results, reproducing the expected shape, with correct onset and end at 88 and 1190 keV, respectively, as well as sharp edges at the reference energies of 88, 88 + 202, 88 + 307 and 88 + 202 + 307 keV. The normalized root-mean square error between simulated and measured spectra varied between 4.3% and 10.4%.


Asunto(s)
Fotones , Tomografía de Emisión de Positrones , Simulación por Computador , Método de Montecarlo
6.
Phys Med Biol ; 65(24): 245003, 2020 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-32693400

RESUMEN

A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the adaptation of current international protocols designed for clinical and preclinical positron emission tomographs (PET) systems. This methodology was used to evaluate the performance of the Flex Solo II PEM scanner in terms of spatial resolution, uniformity and contrast lesion detectability, recovery coefficients and spill-over ratios. Positron range effects were studied with 18F and 68Ga, which have very different energy spectra. Our results indicate that in-plane spatial resolution of the system is around 3.0 mm and 4.4 mm for 18F and 68Ga, respectively. Lesion detectability tests with sphere diameters between 4 and 10 mm confirmed that the PEM system can resolve all the spheres (hot or cold). Percent contrast values for 18F lie between 6%-38% and 34%-51% for hot- and cold- spheres, respectively; the corresponding intervals for 68Ga are lower, 4%-25% and 32%-44%. Regarding uniformity quantification, the system shows percentage standard deviations within 4.9%-5.7%, while the percent background variability measurements ranged between 6.7% and 10.9% for both radionuclides. Recovery coefficients measured with hot rod diameters between 1.5 and 9 mm, have values between 0.2-1.05 and 0.17-0.69 for 18F and 68Ga, respectively. Spill-over ratios have large values (0.22 in average) for both radionuclides. Our results indicate that the phantoms and the methodology developed in this work can serve as the basis for establishing an image quality protocol for the systematic evaluation of PEM systems, with a potential extension for performance evaluation of dedicated breastPET scanners.


Asunto(s)
Electrones , Mamografía/instrumentación , Fantasmas de Imagen , Diseño de Equipo , Control de Calidad , Tomografía Computarizada de Emisión
7.
EJNMMI Phys ; 7(1): 21, 2020 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-32297045

RESUMEN

BACKGROUND: Lutetium oxyorthosilicate or lutetium yttrium oxyorthosilicate (LYSO) scintillation crystals used in most current PET scanner detectors contain 176Lu, which decays by beta emission to excited states of 176Hf accompanied by the emission of prompt gamma rays or internal conversion electrons. This intrinsic radioactivity can be self-detected in singles mode as a constant background signal that has an energy spectrum whose structure has been explained previously. In this work, we studied the energy spectrum due to the intrinsic radioactivity of LYSO scintillation crystals of two opposing detectors working in coincidence mode. The investigation included experimental data, Monte Carlo simulations and an analytical model. RESULTS: The structure of the energy spectrum was completely understood and is the result of the self-detection of beta particles from 176Lu in one crystal and the detection of one or more prompt gamma rays detected in coincidence by the opposing crystal. The most probable coincidence detection involves the gamma rays of 202 and 307 keV, which result in two narrow photopeaks, superimposed on a continuous energy distribution due to the beta particle energy deposition. The relative intensities of the gamma ray peaks depend on crystal size and detector separation distance, as is explained by the analytical model and verified through the Monte Carlo simulations and experiments. CONCLUSIONS: The analytical model used in this work accurately explains the general features of the coincidence energy spectrum due to the presence of 176Lu in the scintillation crystals, as observed experimentally and with Monte Carlo simulations. This work will be useful to those research studies aimed at using the intrinsic radioactivity of LYSO crystals for transmission scans and detector calibration in coincidence mode.

8.
PLoS One ; 9(8): e105877, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25162220

RESUMEN

Two species of fossil polydesmidan millipedes (Diplopoda: Polydesmida) embedded in amber are described from Miocene strata near Simojovel, in the Chiapas Highlands, Mexico. Maatidesmus paachtun gen. et sp. nov., placed into Chelodesmidae Cook, 1895, and Anbarrhacus adamantis gen. et sp. nov., assigned in the family Platyrhacidae Pocock, 1895. Morphological data from fossil specimens have been recovered using 3D X-ray micro-computed tomography and regular to infrared-reflected microscopy. Both fossil species are recognizable as new primarily but not exclusively, by collum margin modification and remarkable paranotal and metatergite dorsal sculpture.


Asunto(s)
Artrópodos/anatomía & histología , Fósiles , Filogenia , Ámbar , Animales , Artrópodos/clasificación , México , Espectrofotometría Infrarroja , Microtomografía por Rayos X
9.
J Biomed Opt ; 19(4): 046002, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24695846

RESUMEN

X-ray luminescence optical tomography (XLOT) is an emerging hybrid imaging modality in which x-ray excitable particles (phosphor particles) emit optical photons when stimulated with a collimated x-ray beam. XLOT can potentially combine the high sensitivity of optical imaging with the high spatial resolution of x-ray imaging. For reconstruction of XLOT data, we compared two reconstruction algorithms, conventional filtered backprojection (FBP) and a new algorithm, x-ray luminescence optical tomography with excitation priors (XLOT-EP), in which photon propagation is modeled with the diffusion equation and the x-ray beam positions are used as reconstruction priors. Numerical simulations based on dose calculations were used to validate the proposed XLOT imaging system and the reconstruction algorithms. Simulation results showed nanoparticle concentrations reconstructed with XLOT-EP are much less dependent on scan depth than those obtained with FBP. Measurements at just two orthogonal projections are sufficient for XLOT-EP to reconstruct an XLOT image for simple source distributions. The heterogeneity of x-ray energy deposition is included in the XLOT-EP reconstruction and improves the reconstruction accuracy, suggesting that there is a need to calculate the x-ray energy distribution for experimental XLOT imaging.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Óptica/métodos , Algoritmos , Simulación por Computador , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
10.
Radiother Oncol ; 96(2): 250-3, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20378193

RESUMEN

This work reports the use of both GafChromic EBT film immersed in a water phantom and Monte Carlo (MC) simulations for small photon beam stereotactic radiosurgery dosimetry. Circularly collimated photon beams with diameters in the 4-20 mm range of a dedicated 6 MV linear accelerator (Novalis, BrainLAB, Germany) were used to perform off-axis ratios, tissue maximum ratios and total scatter factors measurements, and MC simulations. GafChromic EBT film data show an excellent agreement with MC results (<2.7%) for all measured quantities.


Asunto(s)
Método de Montecarlo , Fantasmas de Imagen , Fotones , Radiometría/métodos , Agua , Dosimetría por Película/métodos
11.
J Appl Clin Med Phys ; 9(3): 90-98, 2008 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-18716595

RESUMEN

Micro-multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation system and requires the use of detectors with high spatial resolution, high sensitivity and practically no energy dependence. In this work the use of GafChromic EBT radiochromic film to measure the basic dosimetric properties of the m3-mMLC (BrainLAB, Germany) micro-multileaf collimator system integrated to a 6 MV linear accelerator, is reported. Results show that average values of transmission and leakage radiation are 0.93 +/- 0.05% and 1.08 +/- 0.08%, respectively. The 80-20% beam penumbra were found to be 2.26 +/- 0.11 mm along the leaf side (perpendicular to leaf motion) and 2.31 +/- 0.11 mm along the leaf end (parallel to leaf motion) using square field sizes ranging from 9.1 to 1.8 cm. These measurements are in agreement with values reported in the literature for the same type of mMLC using different radiation detectors.


Asunto(s)
Aceleradores de Partículas , Radiocirugia/métodos , Dosimetría por Película/instrumentación , Dosimetría por Película/métodos , Dosimetría por Película/enfermería , Humanos
12.
Eur J Nucl Med Mol Imaging ; 34(7): 1039-49, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17287961

RESUMEN

PURPOSE: A procedure for the measurement of spatial dose rate distribution of beta particles emitted by 186Re-liposomes in tumoral tissue, using HS GafChromic films, is presented. METHODS: HNSCC xenografts were intratumorally injected with 3.7 or 11.1 MBq of 186Re-liposomes, and planar gamma camera images were acquired to determine the liposome retention in the tumor. After imaging, rats were sacrificed and tumors were excised and processed in slices; HS film sections were placed between slices and the tumor lobe was reassembled. Tumors and films were kept in the dark at 4 degrees C for 18 h. After irradiation, films were removed and response was read using a transmission scanner. Films were analyzed to determine two-dimensional spatial dose rate distributions and cumulative dose volume histograms. Dose rate distributions were quantified using a 60Co calibration curve, the 186Re physical half-life, and a perturbation factor that takes into account the effect of the film protective layer. RESULTS: Dose rate distributions are highly heterogeneous with maximal dose rates about 0.4 Gy h(-1) in tumors injected with 3.7 MBq and 1.3 Gy h(-1) in tumors injected with 11.1 MBq. Dose volume histograms showed dose distributed in more than 95% and 80% of the tumor when injected with the lower and the higher activity, respectively. CONCLUSION: The described procedures and techniques have shown the potential and utility of HS GafChromic film for determination of dose rate distributions in solid tumors injected intratumorally with 186Re-liposomes. The film's structure and the liposomes' biodistribution must be taken into account to obtain quantitative dose measurements.


Asunto(s)
Carcinoma de Células Escamosas/metabolismo , Dosimetría por Película/métodos , Liposomas/química , Radioisótopos/farmacocinética , Radiofármacos/administración & dosificación , Renio/administración & dosificación , Renio/farmacocinética , Animales , Carcinoma de Células Escamosas/radioterapia , Portadores de Fármacos/química , Humanos , Masculino , Radioisótopos/administración & dosificación , Radiofármacos/farmacocinética , Dosificación Radioterapéutica , Ratas , Ratas Desnudas , Efectividad Biológica Relativa , Distribución Tisular