Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Appl Physiol (1985) ; 133(6): 1349-1355, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36326472

RESUMEN

Spaceflight associated neuro-ocular syndrome (SANS) is associated with acquired optic disc edema, hyperopia, and posterior globe flattening in some astronauts during long-duration spaceflight possibly due to the headward fluid redistribution in microgravity. The goal of this study was to assess whether strict head-down tilt (HDT) bed rest as a spaceflight analog would produce globe flattening and whether centrifugation could prevent these changes. Twenty-four healthy subjects separated into three groups underwent 60 days of strict 6° HDT bed rest: one control group with no countermeasure (n = 8) and two countermeasure groups exposed to 30 min daily of short-arm centrifugation as a means of artificial gravity (AG), either intermittent (iAG, n = 8) or continuous (cAG, n = 8). Magnetic resonance images (MRI) were collected at baseline, HDT-day 14, HDT-day 52, and 3 days after bed rest. An automated method was applied to quantify posterior globe volume displacement compared with baseline scans. On average, subjects showed an increasing degree of globe volume displacement with bed rest duration (means ± SE: 1.41 ± 1.01 mm3 on HDT14 and 4.04 ± 1.19 mm3 on HDT52) that persisted post-bed rest (5.51 ± 1.26 mm3). Application of 30 min daily AG did not have a significant impact on globe volume displacement (P = 0.42 for cAG and P = 0.93 for iAG compared with control). These results indicate that strict 6° HDT bed rest produced displacement of the posterior globe with a trend of increasing displacement with longer duration that was not prevented by daily 30 min exposure to AG.NEW & NOTEWORTHY Head-down tilt (HDT) bed rest is commonly used as a spaceflight analog for investigating spaceflight associated neuro-ocular syndrome (SANS). Posterior ocular globe flattening has been identified in astronauts with SANS but until now has not been investigated during HDT bed rest. In this study, posterior ocular globe volume displacement was quantified before, during, and after HDT bed rest and countermeasures were tested for their potential to reduce the degree of globe flattening.


Asunto(s)
Gravedad Alterada , Vuelo Espacial , Humanos , Inclinación de Cabeza , Reposo en Cama , Astronautas , Imagen por Resonancia Magnética
2.
Fluids Barriers CNS ; 19(1): 8, 2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35090516

RESUMEN

BACKGROUND: Intrathecal drug delivery has a significant role in pain management and central nervous system (CNS) disease therapeutics. A fluid-physics based tool to assist clinicians in choosing specific drug doses to the spine or brain may help improve treatment schedules. METHODS: This study applied computational fluid dynamics (CFD) and in vitro model verification to assess intrathecal drug delivery in an anatomically idealized model of the human CSF system with key anatomic features of the CNS. Key parameters analyzed included the role of (a) injection location including lumbar puncture (LP), cisterna magna (CM) and intracerebroventricular (ICV), (b) LP injection rate, injection volume, and flush volume, (c) physiologic factors including cardiac-induced and deep respiration-induced CSF stroke volume increase. Simulations were conducted for 3-h post-injection and used to quantify spatial-temporal tracer concentration, regional area under the curve (AUC), time to maximum concentration (Tmax), and maximum concentration (Cmax), for each case. RESULTS: CM and ICV increased AUC to brain regions by ~ 2 logs compared to all other simulations. A 3X increase in bolus volume and addition of a 5 mL flush both increased intracranial AUC to the brain up to 2X compared to a baseline 5 mL LP injection. In contrast, a 5X increase in bolus rate (25 mL/min) did not improve tracer exposure to the brain. An increase in cardiac and respiratory CSF movement improved tracer spread to the brain, basal cistern, and cerebellum up to ~ 2 logs compared to the baseline LP injection. CONCLUSION: The computational modeling approach provides ability to conduct in silico trials representative of CSF injection protocols. Taken together, the findings indicate a strong potential for delivery protocols to be optimized to reach a target region(s) of the spine and/or brain with a needed therapeutic dose. Parametric modification of bolus rate/volume and flush volume was found to have impact on tracer distribution; albeit to a smaller degree than injection location, with CM and ICV injections resulting in greater therapeutic dose to brain regions compared to LP. CSF stroke volume and frequency both played an important role and may potentially have a greater impact than the modest changes in LP injection protocols analyzed such as bolus rate, volume, and flush.


Asunto(s)
Líquido Cefalorraquídeo , Cisterna Magna , Sistemas de Liberación de Medicamentos , Inyecciones Intraventriculares , Inyecciones Espinales , Modelos Teóricos , Simulación por Computador , Humanos , Hidrodinámica
3.
Front Neuroimaging ; 1: 879098, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37555174

RESUMEN

Background: Understanding the relationship between cerebrospinal fluid (CSF) dynamics and intrathecal drug delivery (ITDD) injection parameters is essential to improve treatment of central nervous system (CNS) disorders. Methods: An anatomically detailed in vitro model of the complete CSF system was constructed. Patient-specific cardiac- and respiratory-induced CSF oscillations were input to the model in the subarachnoid space and within the ventricles. CSF production was input at the lateral ventricles and CSF absorption at the superior sagittal sinus. A model small molecule simulated drug product containing fluorescein was imaged within the system over a period of 3-h post-lumbar ITDD injections and used to quantify the impact of (a) bolus injection volume and rate, (b) post-injection flush volume, rate, and timing, (c) injection location, and (d) type of injection device. For each experiment, neuraxial distribution of fluorescein in terms of spatial temporal concentration, area-under-the-curve (AUC), and percent of injected dose (%ID) to the brain was quantified at a time point 3-h post-injection. Results: For all experiments conducted with ITDD administration in the lumbar spine, %ID to the brain did not exceed 11.6% at a time point 3-h post-injection. Addition of a 12 mL flush slightly increased solute transport to the brain up to +3.9%ID compared to without a flush (p < 0.01). Implantation of a lumbar catheter with the tip at an equivalent location to the lumbar placed needle, but with rostral tip orientation, resulted in a small improvement of 1.5%ID to the brain (p < 0.05). An increase of bolus volume from 5 to 20 mL improved solute transport to the brain from 5.0 to 6.3%ID, but this improvement was not statistically significant. Increasing bolus injection rate from 5 to 13.3 mL/min lacked improvement of solute transport to the brain, with a value of 6.3 compared to 5.7%ID. Conclusion: The in vitro modeling approach allowed precisely controlled and repeatable parametric investigation of ITDD injection protocols and devices. In combination, the results predict that parametric changes in lumbar spine ITDD-injection related parameters and devices can alter %ID to the brain and be tuned to optimize therapeutic benefit to CNS targets.

4.
J R Soc Interface ; 18(177): 20200920, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33906382

RESUMEN

Spaceflight is known to cause ophthalmic changes in a condition known as spaceflight-associated neuro-ocular syndrome (SANS). It is hypothesized that SANS is caused by cephalad fluid shifts and potentially mild elevation of intracranial pressure (ICP) in microgravity. Head-down tilt (HDT) studies are a ground-based spaceflight analogue to create cephalad fluid shifts. Here, we developed non-invasive magnetic resonance imaging (MRI)-based techniques to quantify ophthalmic structural changes under acute 15° HDT. We specifically quantified: (i) change in optic nerve sheath (ONS) and optic nerve (ON) cross-sectional area, (ii) change in ON deviation, an indicator of ON tortuosity, (iii) change in vitreous chamber depth, and (iv) an estimated ONS Young's modulus. Under acute HDT, ONS cross-sectional area increased by 4.04 mm2 (95% CI 2.88-5.21 mm2, p < 0. 000), while ON cross-sectional area remained nearly unchanged (95% CI -0.12 to 0.43 mm2, p = 0.271). ON deviation increased under HDT by 0.20 mm (95% CI 0.08-0.33 mm, p = 0.002). Vitreous chamber depth decreased under HDT by -0.11 mm (95% CI -0.21 to -0.03 mm, p = 0.009). ONS Young's modulus was estimated to be 85.0 kPa. We observed a significant effect of sex and BMI on ONS parameters, of interest since they are known risk factors for idiopathic intracranial hypertension. The tools developed herein will be useful for future analyses of ON changes in various conditions.


Asunto(s)
Inclinación de Cabeza , Ingravidez , Voluntarios Sanos , Humanos , Imagen por Resonancia Magnética , Simulación de Ingravidez
5.
Fluids Barriers CNS ; 18(1): 12, 2021 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-33736664

RESUMEN

BACKGROUND: Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. METHODS: An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. RESULTS: Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ± 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). CONCLUSION: Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.


Asunto(s)
Malformación de Arnold-Chiari/líquido cefalorraquídeo , Malformación de Arnold-Chiari/diagnóstico por imagen , Líquido Cefalorraquídeo/fisiología , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Preescolar , Humanos , Hidrodinámica , Metaanálisis como Asunto , Modelos Anatómicos , Reproducibilidad de los Resultados , Literatura de Revisión como Asunto
6.
Eye (Lond) ; 35(7): 1869-1878, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33514895

RESUMEN

BACKGROUND/OBJECTIVES: Spaceflight associated neuro-ocular syndrome (SANS), a health risk related to long-duration spaceflight, is hypothesized to result from a headward fluid shift that occurs with the loss of hydrostatic pressure gradients in weightlessness. Shifts in the vascular and cerebrospinal fluid compartments alter the mechanical forces at the posterior eye and lead to flattening of the posterior ocular globe. The goal of the present study was to develop a method to quantify globe flattening observed by magnetic resonance imaging after spaceflight. SUBJECTS/METHODS: Volumetric displacement of the posterior globe was quantified in 10 astronauts at 5 time points after spaceflight missions of ~6 months. RESULTS: Mean globe volumetric displacement was 9.88 mm3 (95% CI 4.56-15.19 mm3, p < 0.001) on the first day of assessment after the mission (R[return]+ 1 day); 9.00 mm3 (95% CI 3.73-14.27 mm3, p = 0.001) at R + 30 days; 6.53 mm3 (95% CI 1.24-11.83 mm3, p < 0.05) at R + 90 days; 4.45 mm3 (95% CI -0.96 to 9.86 mm3, p = 0.12) at R + 180 days; and 7.21 mm3 (95% CI 1.82-12.60 mm3, p < 0.01) at R + 360 days. CONCLUSIONS: There was a consistent inward displacement of the globe at the optic nerve, which had only partially resolved 1 year after landing. More pronounced globe flattening has been observed in previous studies of astronauts; however, those observations lacked quantitative measures and were subjective in nature. The novel automated method described here allows for detailed quantification of structural changes in the posterior globe that may lead to an improved understanding of SANS.


Asunto(s)
Vuelo Espacial , Ingravidez , Astronautas , Humanos , Presión Intracraneal , Imagen por Resonancia Magnética , Ingravidez/efectos adversos
7.
PLoS One ; 15(12): e0244090, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33378399

RESUMEN

A detailed understanding of the CSF dynamics is needed for design and optimization of intrathecal drug delivery devices, drugs, and protocols. Preclinical research using large-animal models is important to help define drug pharmacokinetics-pharmacodynamics and safety. In this study, we investigated the impact of catheter implantation in the sub-dural space on CSF flow dynamics in Cynomolgus monkeys. Magnetic resonance imaging (MRI) was performed before and after catheter implantation to quantify the differences based on catheter placement location in the cervical compared to the lumbar spine. Several geometric and hydrodynamic parameters were calculated based on the 3D segmentation and flow analysis. Hagen-Poiseuille equation was used to investigate the impact of catheter implantation on flow reduction and hydraulic resistance. A linear mixed-effects model was used in this study to investigate if there was a statistically significant difference between cervical and lumbar implantation, or between two MRI time points. Results showed that geometric parameters did not change statistically across MRI measurement time points and did not depend on catheter location. However, catheter insertion did have a significant impact on the hydrodynamic parameters and the effect was greater with cervical implantation compared to lumbar implantation. CSF flow rate decreased up to 55% with the catheter located in the cervical region. The maximum flow rate reduction in the lumbar implantation group was 21%. Overall, lumbar catheter implantation disrupted CSF dynamics to a lesser degree than cervical catheter implantation and this effect remained up to two weeks post-catheter implantation in Cynomolgus monkeys.


Asunto(s)
Cateterismo , Líquido Cefalorraquídeo/metabolismo , Hidrodinámica , Animales , Macaca fascicularis , Imagen por Resonancia Magnética , Masculino
8.
Fluids Barriers CNS ; 17(1): 68, 2020 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-33183314

RESUMEN

BACKGROUND: The pia arachnoid complex (PAC) is a cerebrospinal fluid-filled tissue conglomerate that surrounds the brain and spinal cord. Pia mater adheres directly to the surface of the brain while the arachnoid mater adheres to the deep surface of the dura mater. Collagen fibers, known as subarachnoid trabeculae (SAT) fibers, and microvascular structure lie intermediately to the pia and arachnoid meninges. Due to its structural role, alterations to the biomechanical properties of the PAC may change surface stress loading in traumatic brain injury (TBI) caused by sub-concussive hits. The aim of this study was to quantify the mechanical and morphological properties of ovine PAC. METHODS: Ovine brain samples (n = 10) were removed from the skull and tissue was harvested within 30 min post-mortem. To access the PAC, ovine skulls were split medially from the occipital region down the nasal bone on the superior and inferior aspects of the skull. A template was used to remove arachnoid samples from the left and right sides of the frontal and occipital regions of the brain. 10 ex-vivo samples were tested with uniaxial tension at 2 mm s-1, average strain rate of 0.59 s-1, until failure at < 5 h post extraction. The force and displacement data were acquired at 100 Hz. PAC tissue collagen fiber microstructure was characterized using second-harmonic generation (SHG) imaging on a subset of n = 4 stained tissue samples. To differentiate transverse blood vessels from SAT by visualization of cell nuclei and endothelial cells, samples were stained with DAPI and anti-von Willebrand Factor, respectively. The Mooney-Rivlin model for average stress-strain curve fit was used to model PAC material properties. RESULTS: The elastic modulus, ultimate stress, and ultimate strain were found to be 7.7 ± 3.0, 2.7 ± 0.76 MPa, and 0.60 ± 0.13, respectively. No statistical significance was found across brain dissection locations in terms of biomechanical properties. SHG images were post-processed to obtain average SAT fiber intersection density, concentration, porosity, tortuosity, segment length, orientation, radial counts, and diameter as 0.23, 26.14, 73.86%, 1.07 ± 0.28, 17.33 ± 15.25 µm, 84.66 ± 49.18°, 8.15%, 3.46 ± 1.62 µm, respectively. CONCLUSION: For the sizes, strain, and strain rates tested, our results suggest that ovine PAC mechanical behavior is isotropic, and that the Mooney-Rivlin model is an appropriate curve-fitting constitutive equation for obtaining material parameters of PAC tissues.


Asunto(s)
Aracnoides/anatomía & histología , Aracnoides/fisiología , Fenómenos Biomecánicos/fisiología , Piamadre/anatomía & histología , Piamadre/fisiología , Animales , Modelos Animales , Modelos Biológicos , Ovinos
9.
NPJ Microgravity ; 6: 30, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33083526

RESUMEN

A subset of long-duration spaceflight astronauts have experienced ophthalmic abnormalities, collectively termed spaceflight-associated neuro-ocular syndrome (SANS). Little is understood about the pathophysiology of SANS; however, microgravity-induced alterations in intracranial pressure (ICP) due to headward fluid shifts is the primary hypothesized contributor. In particular, potential changes in optic nerve (ON) tortuosity and ON sheath (ONS) distension may indicate altered cerebrospinal fluid dynamics during weightlessness. The present longitudinal study aims to provide a quantitative analysis of ON and ONS cross-sectional areas, and ON deviation, an indication of tortuosity, before and after spaceflight. Ten astronauts undergoing ~6-month missions on the International Space Station (ISS) underwent high-resolution magnetic resonance imaging (MRI) preflight and at five recovery time points extending to 1 year after return from the ISS. The mean changes in ON deviation, ON cross-sectional area, and ONS cross-sectional area immediately post flight were -0.14 mm (95% CI: -0.36 to 0.08, Bonferroni-adjusted P = 1.00), 0.13 mm2 (95% CI -0.66 to 0.91, Bonferroni-adjusted P = 1.00), and -0.22 mm2 (95% CI: -1.78 to 1.34, Bonferroni-adjusted P = 1.00), respectively, and remained consistent during the recovery period. Terrestrially, ONS distension is associated with increased ICP; therefore, these results suggest that, on average, ICP was not pathologically elevated immediately after spaceflight. However, a subject diagnosed with optic disc edema (Frisen Grade 1, right eye) displayed increased ONS area post flight, although this increase is relatively small compared to clinical populations with increased ICP. Advanced quantitative MRI-based assessment of the ON and ONS could help our understanding of SANS and the role of ICP.

10.
J Mech Behav Biomed Mater ; 110: 103924, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32957219

RESUMEN

The optic nerve sheath (ONS) is biomechanically important. It is acted on by tension due to ocular movements, and by fluid shifts and/or alterations in intracranial pressure (ICP) in human disease, specifically in pathologies leading to intracranial hypertension. It has also been hypothesized that the ONS is acted on by altered ICP in astronauts exposed chronically to microgravity. However, a non-invasive method to quantify ONS biomechanical properties is not presently available; knowledge of such properties is desirable to allow characterization of the biomechanical forces exerted on the optic nerve head and other ocular structures due to the ONS. Thus, the primary objective of this study was to characterize the biomechanical properties (stiffness) of the human ONS in vivo as a necessary step towards investigating the role of ICP in various conditions, including Spaceflight Associated Neuro-ocular Syndrome (SANS). We acquired non-invasive magnetic resonance imaging (MRI) scans of ostensibly healthy subjects (n = 18, age = 30.4 ± 11.6 [mean ± SD] years) during supine and 15-degree head-down-tilt (HDT) postures, and extracted ONS contours from these scans. We then used finite element modeling to quantify ONS expansion due to postural changes and an inverse approach to estimate ONS stiffness. Using this non-invasive procedure, we estimated an in vivo ONS stiffness of 39.2 ± 21.9 kPa (mean ± SD), although a small subset of individuals had very stiff ONS that precluded accurate estimates of their stiffness values. ONS stiffness was not correlated with age and was higher in males than females.


Asunto(s)
Hipertensión Intracraneal , Presión Intracraneal , Adolescente , Adulto , Femenino , Análisis de Elementos Finitos , Humanos , Imagen por Resonancia Magnética , Masculino , Nervio Óptico/diagnóstico por imagen , Adulto Joven
11.
Fluids Barriers CNS ; 17(1): 23, 2020 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-32178689

RESUMEN

BACKGROUND: Blood removal from cerebrospinal fluid (CSF) in post-subarachnoid hemorrhage patients may reduce the risk of related secondary brain injury. We formulated a computational fluid dynamics (CFD) model to investigate the impact of a dual-lumen catheter-based CSF filtration system, called Neurapheresis™ therapy, on blood removal from CSF compared to lumbar drain. METHODS: A subject-specific multiphase CFD model of CSF system-wide solute transport was constructed based on MRI measurements. The Neurapheresis catheter geometry was added to the model within the spinal subarachnoid space (SAS). Neurapheresis flow aspiration and return rate was 2.0 and 1.8 mL/min, versus 0.2 mL/min drainage for lumbar drain. Blood was modeled as a bulk fluid phase within CSF with a 10% initial tracer concentration and identical viscosity and density as CSF. Subject-specific oscillatory CSF flow was applied at the model inlet. The dura and spinal cord geometry were considered to be stationary. Spatial-temporal tracer concentration was quantified based on time-average steady-streaming velocities throughout the domain under Neurapheresis therapy and lumbar drain. To help verify CFD results, an optically clear in vitro CSF model was constructed with fluorescein used as a blood surrogate. Quantitative comparison of numerical and in vitro results was performed by linear regression of spatial-temporal tracer concentration over 24-h. RESULTS: After 24-h, tracer concentration was reduced to 4.9% under Neurapheresis therapy compared to 6.5% under lumbar drain. Tracer clearance was most rapid between the catheter aspiration and return ports. Neurapheresis therapy was found to have a greater impact on steady-streaming compared to lumbar drain. Steady-streaming in the cranial SAS was ~ 50× smaller than in the spinal SAS for both cases. CFD results were strongly correlated with the in vitro spatial-temporal tracer concentration under Neurapheresis therapy (R2 = 0.89 with + 2.13% and - 1.93% tracer concentration confidence interval). CONCLUSION: A subject-specific CFD model of CSF system-wide solute transport was used to investigate the impact of Neurapheresis therapy on tracer removal from CSF compared to lumbar drain over a 24-h period. Neurapheresis therapy was found to substantially increase tracer clearance compared to lumbar drain. The multiphase CFD results were verified by in vitro fluorescein tracer experiments.


Asunto(s)
Eliminación de Componentes Sanguíneos/métodos , Sangre , Catéteres , Líquido Cefalorraquídeo , Drenaje , Diseño de Equipo , Modelos Biológicos , Punción Espinal , Hemorragia Subaracnoidea/terapia , Adulto , Eliminación de Componentes Sanguíneos/instrumentación , Femenino , Humanos , Hidrodinámica , Imagen por Resonancia Magnética , Adulto Joven
12.
Fluids Barriers CNS ; 17(1): 4, 2020 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-31959193

RESUMEN

BACKGROUND: Developing novel therapeutic agents to treat amyotrophic lateral sclerosis (ALS) has been difficult due to multifactorial pathophysiologic processes at work. Intrathecal drug administration shows promise due to close proximity of cerebrospinal fluid (CSF) to affected tissues. Development of effective intrathecal pharmaceuticals will rely on accurate models of how drugs are dispersed in the CSF. Therefore, a method to quantify these dynamics and a characterization of differences across disease states is needed. METHODS: Complete intrathecal 3D CSF geometry and CSF flow velocities at six axial locations in the spinal canal were collected by T2-weighted and phase-contrast MRI, respectively. Scans were completed for eight people with ALS and ten healthy controls. Manual segmentation of the spinal subarachnoid space was performed and coupled with an interpolated model of CSF flow within the spinal canal. Geometric and hydrodynamic parameters were then generated at 1 mm slice intervals along the entire spine. Temporal analysis of the waveform spectral content and feature points was also completed. RESULTS: Comparison of ALS and control groups revealed a reduction in CSF flow magnitude and increased flow propagation velocities in the ALS cohort. Other differences in spectral harmonic content and geometric comparisons may support an overall decrease in intrathecal compliance in the ALS group. Notably, there was a high degree of variability between cases, with one ALS patient displaying nearly zero CSF flow along the entire spinal canal. CONCLUSION: While our sample size limits statistical confidence about the differences observed in this study, it was possible to measure and quantify inter-individual and cohort variability in a non-invasive manner. Our study also shows the potential for MRI based measurements of CSF geometry and flow to provide information about  the hydrodynamic environment of the spinal subarachnoid space. These dynamics may be studied further to understand the behavior of CSF solute transport in healthy and diseased states.


Asunto(s)
Esclerosis Amiotrófica Lateral/líquido cefalorraquídeo , Esclerosis Amiotrófica Lateral/diagnóstico por imagen , Líquido Cefalorraquídeo/diagnóstico por imagen , Imagen por Resonancia Magnética , Espacio Subaracnoideo/diagnóstico por imagen , Adulto , Líquido Cefalorraquídeo/fisiología , Simulación por Computador , Humanos , Hidrodinámica , Imagen por Resonancia Magnética/métodos , Masculino , Modelos Biológicos , Canal Medular/fisiología
13.
J Biomech Eng ; 142(2)2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31343659

RESUMEN

It has been hypothesized that early and rapid filtration of blood from cerebrospinal fluid (CSF) in postsubarachnoid hemorrhage patients may reduce hospital stay and related adverse events. In this study, we formulated a subject-specific computational fluid dynamics (CFD) model to parametrically investigate the impact of a novel dual-lumen catheter-based CSF filtration system, the Neurapheresis™ system (Minnetronix Neuro, Inc., St. Paul, MN), on intrathecal CSF dynamics. The operating principle of this system is to remove CSF from one location along the spine (aspiration port), externally filter the CSF routing the retentate to a waste bag, and return permeate (uncontaminated CSF) to another location along the spine (return port). The CFD model allowed parametric simulation of how the Neurapheresis system impacts intrathecal CSF velocities and steady-steady streaming under various Neurapheresis flow settings ranging from 0.5 to 2.0 ml/min and with a constant retentate removal rate of 0.2 ml/min simulation of the Neurapheresis system were compared to a lumbar drain simulation with a typical CSF removal rate setting of 0.2 ml/min. Results showed that the Neurapheresis system at a maximum flow of 2.0 ml/min increased average steady streaming CSF velocity 2× in comparison to lumbar drain (0.190 ± 0.133 versus 0.093 ± 0.107 mm/s, respectively). This affect was localized to the region within the Neurapheresis flow loop. The mean velocities introduced by the flow loop were relatively small in comparison to normal cardiac-induced CSF velocities.


Asunto(s)
Simulación por Computador , Hidrodinámica , Modelos Biológicos , Columna Vertebral
14.
Fluids Barriers CNS ; 16(1): 13, 2019 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-31056079

RESUMEN

BACKGROUND: As an alternative to advection, solute transport by shear-augmented dispersion within oscillatory cerebrospinal fluid flow was investigated in small channels representing the basement membranes located between cerebral arterial smooth muscle cells, the paraarterial space surrounding the vessel wall and in large channels modeling the spinal subarachnoid space (SSS). METHODS: Geometries were modeled as two-dimensional. Fully developed flows in the channels were modeled by the Darcy-Brinkman momentum equation and dispersion by the passive transport equation. Scaling of the enhancement of axial dispersion relative to molecular diffusion was developed for regimes of flow including quasi-steady, porous and unsteady, and for regimes of dispersion including diffusive and unsteady. RESULTS: Maximum enhancement occurs when the characteristic time for lateral dispersion is matched to the cycle period. The Darcy-Brinkman model represents the porous media as a continuous flow resistance, and also imposes no-slip boundary conditions at the walls of the channel. Consequently, predicted dispersion is always reduced relative to that of a channel without porous media, except when the flow and dispersion are both unsteady. DISCUSSION/CONCLUSIONS: In the basement membranes, flow and dispersion are both quasi-steady and enhancement of dispersion is small even if lateral dispersion is reduced by the porous media to achieve maximum enhancement. In the paraarterial space, maximum enhancement Rmax = 73,200 has the potential to be significant. In the SSS, the dispersion is unsteady and the flow is in the transition zone between porous and unsteady. Enhancement is 5.8 times that of molecular diffusion, and grows to a maximum of 1.6E+6 when lateral dispersion is increased. The maximum enhancement produces rostral transport time in agreement with experiments.


Asunto(s)
Modelos Teóricos , Soluciones/administración & dosificación , Soluciones/metabolismo , Espacio Subaracnoideo/efectos de los fármacos , Espacio Subaracnoideo/metabolismo , Transporte Biológico/fisiología , Sistema Nervioso Central/efectos de los fármacos , Sistema Nervioso Central/metabolismo , Difusión/efectos de los fármacos , Humanos , Inyecciones Espinales , Porosidad/efectos de los fármacos
15.
PLoS One ; 14(2): e0212239, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30811449

RESUMEN

Recent advancements have been made toward understanding the diagnostic and therapeutic potential of cerebrospinal fluid (CSF) and related hydrodynamics. Increased understanding of CSF dynamics may lead to improved detection of central nervous system (CNS) diseases and optimized delivery of CSF based CNS therapeutics, with many proposed therapeutics hoping to successfully treat or cure debilitating neurological conditions. Before significant strides can be made toward the research and development of interventions designed for human use, additional research must be carried out with representative subjects such as non-human primates (NHP). This study presents a geometric and hydrodynamic characterization of CSF in eight cynomolgus monkeys (Macaca fascicularis) at baseline and two-week follow-up. Results showed that CSF flow along the entire spine was laminar with a Reynolds number ranging up to 80 and average Womersley number ranging from 4.1-7.7. Maximum CSF flow rate occurred ~25 mm caudal to the foramen magnum. Peak CSF flow rate ranged from 0.3-0.6 ml/s at the C3-C4 level. Geometric analysis indicated that average intrathecal CSF volume below the foramen magnum was 7.4 ml. The average surface area of the spinal cord and dura was 44.7 and 66.7 cm2 respectively. Subarachnoid space cross-sectional area and hydraulic diameter ranged from 7-75 mm2 and 2-3.7 mm, respectively. Stroke volume had the greatest value of 0.14 ml at an axial location corresponding to C3-C4.


Asunto(s)
Enfermedades del Sistema Nervioso Central/diagnóstico por imagen , Líquido Cefalorraquídeo/diagnóstico por imagen , Imagen por Resonancia Magnética , Columna Vertebral/diagnóstico por imagen , Animales , Femenino , Hidrodinámica , Macaca fascicularis , Masculino
16.
Neurosurgery ; 85(6): 854-860, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30690581

RESUMEN

The management of Chiari I malformation (CMI) is controversial because treatment methods vary and treatment decisions rest on incomplete understanding of its complex symptom patterns, etiologies, and natural history. Validity of studies that attempt to compare treatment of CMI has been limited because of variable terminology and methods used to describe study subjects. The goal of this project was to standardize terminology and methods by developing a comprehensive set of Common Data Elements (CDEs), data definitions, case report forms (CRFs), and outcome measure recommendations for use in CMI clinical research, as part of the CDE project at the National Institute of Neurological Disorders and Stroke (NINDS) of the US National Institutes of Health. A working group, comprising over 30 experts, developed and identified CDEs, template CRFs, data dictionaries, and guidelines to aid investigators starting and conducting CMI clinical research studies. The recommendations were compiled, internally reviewed, and posted online for external public comment. In October 2016, version 1.0 of the CMI CDE recommendations became available on the NINDS CDE website. The recommendations span these domains: Core Demographics/Epidemiology; Presentation/Symptoms; Co-Morbidities/Genetics; Imaging; Treatment; and Outcome. Widespread use of CDEs could facilitate CMI clinical research trial design, data sharing, retrospective analyses, and consistent data sharing between CMI investigators around the world. Updating of CDEs will be necessary to keep them relevant and applicable to evolving research goals for understanding CMI and its treatment.


Asunto(s)
Malformación de Arnold-Chiari/epidemiología , Investigación Biomédica/normas , Elementos de Datos Comunes , Personal de Salud/normas , National Institute of Neurological Disorders and Stroke (U.S.)/normas , Malformación de Arnold-Chiari/diagnóstico por imagen , Malformación de Arnold-Chiari/terapia , Investigación Biomédica/tendencias , Personal de Salud/tendencias , Humanos , National Institute of Neurological Disorders and Stroke (U.S.)/tendencias , Evaluación de Resultado en la Atención de Salud/normas , Evaluación de Resultado en la Atención de Salud/tendencias , Estudios Retrospectivos , Estados Unidos/epidemiología
17.
Fluids Barriers CNS ; 15(1): 33, 2018 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-30554565

RESUMEN

BACKGROUND: Type 1 Chiari malformation (CM-I) has been historically defined by cerebellar tonsillar position (TP) greater than 3-5 mm below the foramen magnum (FM). Often, the radiographic findings are highly variable, which may influence the clinical course and patient outcome. In this study, we evaluate the inter-operator reliability (reproducibility) of MRI-based measurement of TP in CM-I patients and healthy controls. METHODS: Thirty-three T2-weighted MRI sets were obtained for 23 CM-I patients (11 symptomatic and 12 asymptomatic) and 10 healthy controls. TP inferior to the FM was measured in the mid-sagittal plane by seven expert operators with reference to McRae's line. Overall agreement between the operators was quantified by intraclass correlation coefficient (ICC). RESULTS: The mean and standard deviation of cerebellar TP measurements for asymptomatic (CM-Ia) and symptomatic (CM-Is) patients in mid-sagittal plane was 6.38 ± 2.19 and 9.57 ± 2.63 mm, respectively. TP measurements for healthy controls was 0.48 ± 2.88 mm. The average range of TP measurements for all data sets analyzed was 7.7 mm. Overall operator agreement for TP measurements was relatively high with an ICC of 0.83. CONCLUSION: The results demonstrated a large average range (7.7 mm) of measurements among the seven expert operators and support that, if economically feasible, two radiologists should make independent measurements before radiologic diagnosis of CM-I and surgery is contemplated. In the future, an objective diagnostic parameter for CM-I that utilizes automated algorithms and results in smaller inter-operator variation may improve patient selection.


Asunto(s)
Malformación de Arnold-Chiari/diagnóstico por imagen , Malformación de Arnold-Chiari/patología , Cerebelo/diagnóstico por imagen , Cerebelo/patología , Adulto , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
18.
J Biomech Eng ; 140(8)2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-30003260

RESUMEN

Cerebrospinal fluid (CSF) dynamics are thought to play a vital role in central nervous system (CNS) physiology. The objective of this study was to investigate the impact of spinal cord (SC) nerve roots (NR) on CSF dynamics. A subject-specific computational fluid dynamics (CFD) model of the complete spinal subarachnoid space (SSS) with and without anatomically realistic NR and nonuniform moving dura wall deformation was constructed. This CFD model allowed detailed investigation of the impact of NR on CSF velocities that is not possible in vivo using magnetic resonance imaging (MRI) or other noninvasive imaging methods. Results showed that NR altered CSF dynamics in terms of velocity field, steady-streaming, and vortical structures. Vortices occurred in the cervical spine around NR during CSF flow reversal. The magnitude of steady-streaming CSF flow increased with NR, in particular within the cervical spine. This increase was located axially upstream and downstream of NR due to the interface of adjacent vortices that formed around NR.


Asunto(s)
Líquido Cefalorraquídeo/metabolismo , Hidrodinámica , Modelos Anatómicos , Raíces Nerviosas Espinales/anatomía & histología , Raíces Nerviosas Espinales/fisiología , Femenino , Humanos , Imagen por Resonancia Magnética , Modelación Específica para el Paciente , Raíces Nerviosas Espinales/diagnóstico por imagen , Espacio Subaracnoideo/anatomía & histología , Espacio Subaracnoideo/diagnóstico por imagen , Espacio Subaracnoideo/fisiología , Adulto Joven
19.
World Neurosurg ; 116: e298-e307, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29733988

RESUMEN

OBJECTIVE: Type 1 Chiari malformation (CM-I) is a craniospinal disorder historically defined by cerebellar tonsillar position greater than 3-5 mm below the foramen magnum (FM). This definition has come under question because quantitative measurements of cerebellar herniation do not always correspond with symptom severity. Researchers have proposed several additional radiographic diagnostic criteria based on dynamic motion of fluids and/or tissues. The present study objective was to determine if cardiac-related craniocaudal spinal cord tissue displacement is an accurate indicator of the presence of CM-I and if tissue displacement is altered with decompression. METHODS: A cohort of 20 symptomatic patients underwent decompression surgery. Fifteen healthy volunteers were recruited for comparison with the CM-I group. Axial phase-contrast magnetic resonance imaging (PC-MRI) measurements were collected before and after surgery at the FM with cranial-caudal velocity encoding and 20 frames per cardiac cycle with retrospective reconstruction. Spinal cord motion (SCM) at the FM was quantified based on the peak-to-peak integral of average spinal cord velocity. RESULTS: Tissue motion for the presurgical group was significantly greater than controls (P = 0.0009). Motion decreased after surgery (P = 0.058) with an effect size of -0.151 mm and a standard error of 0.066 mm. Postoperatively, no statistical difference from controls in bulk displacement at the FM was found (P = 0.200) after post hoc testing using the Tukey adjustment for multiple comparisons. CONCLUSIONS: These results support SCM measurement by PC-MRI as a possible noninvasive radiographic diagnostic for CM-I. Dynamic measurement of SCM provides unique diagnostic information about CM-I alongside static quantification of tonsillar position and other intracranial morphometrics.


Asunto(s)
Síndrome de Cockayne/patología , Síndrome de Cockayne/cirugía , Descompresión Quirúrgica/métodos , Foramen Magno/patología , Médula Espinal/cirugía , Adulto , Síndrome de Cockayne/diagnóstico por imagen , Estudios de Cohortes , Femenino , Foramen Magno/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Médula Espinal/diagnóstico por imagen , Resultado del Tratamiento
20.
Cerebellum ; 17(4): 404-418, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29383659

RESUMEN

Type I Chiari malformation (CMI) is a neurological condition in which the cerebellar tonsils descend into the cervical spinal subarachnoid space resulting in cervico-medullary compression. Early case-control investigations have indicated cognitive deficits in the areas of attention, memory, processing speed, and visuospatial function. The present study further examined cognitive and emotional processing deficits associated with CMI using a dual-task paradigm. Nineteen CMI patients were recruited during pre-surgical consultation and 19 matched control participants identified emotional expressions in separate single and asynchronous dual-task designs. To extend earlier behavioral studies of cognitive effects in CMI, we recorded event-related potentials (ERPs) in the dual-task design. Though response times were slower for CMI patients across the two tasks, behavioral and ERP analyses indicated that patients did not differ from matched controls in the ability to allocate attentional resources between the two tasks. P1 ERP component analyses provided no indication of an emotional arousal deficit in our CMI sample while P3 ERP component analyses suggested a CMI-related deficit in emotional regulation. P3 analysis also yielded evidence for a frontalization of neurophysiological activity in CMI patients. Pain and related depression and anxiety factors accounted for CMI deficits in single-task, but not dual-task, response times. Results are consistent with a dysfunctional fronto-parietal attentional network resulting from either the indirect effects of chronic pain or the direct effects of CMI pathophysiology stemming from cervico-medullary compression.


Asunto(s)
Malformación de Arnold-Chiari/fisiopatología , Malformación de Arnold-Chiari/psicología , Encéfalo/fisiopatología , Cognición/fisiología , Emociones/fisiología , Reconocimiento Facial/fisiología , Adulto , Atención/fisiología , Dolor Crónico/fisiopatología , Dolor Crónico/psicología , Electroencefalografía , Potenciales Evocados , Femenino , Humanos , Masculino , Pruebas Neuropsicológicas , Percepción Social
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...