1.
Am J Cardiol ; 203: 105-112, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37487404

RESUMEN

Because of its anatomic and procedural complexities, bicuspid aortic valve (BAV) has been excluded from previous trials investigating transcatheter aortic valve replacement (TAVR). We aimed to compare the clinical outcomes of TAVR in BAV and tricuspid aortic valve patients. We searched the databases systematically from inception until March 2023 for studies that reported the outcomes of TAVR in BAV and tricuspid aortic valve patients. The primary focus was all-cause mortality at 1 year. Additional outcomes included outcomes at 30-day follow-up. Secondary and subgroup analyses were performed on propensity-matched patients, patients at low surgical risk, and based on the type of transcatheter valve type. We included 30 studies with a total of 193,274 patients who underwent TAVR, of which 14,353 patients had BAV stenosis. The rate of 1-year mortality was lower in the BAV group compared with the tricuspid group with the results reaching statistical significance (odds ratio [OR] 0.86, 95% confidence interval [CI] 0.75 to 0.98, p = 0.02). The rate of 30-day stroke, however, was higher in patients with BAV who underwent TAVR (OR 1.24, 95% CI 1.08 to 1.43, p <0.05). Other 30-day clinical outcomes were similar between the 2 groups. Similar outcomes were observed in secondary analysis of matched populations with less mortality and higher rate of stroke in patients with BAV (OR 0.84, 95% CI 0.72 to 0.96, p = 0.01, and OR 1.38, 95% CI 1.09 to 1.75, p <0.05, respectively). Comparing the outcomes for self-expandable and balloon-expandable valves resulted in similar results. Subgroup analysis of low-surgical-risk patients similarly showed lower 1-year mortality in patients with BAV (OR 0.67, 95% CI 0.50 to 0.91, p = 0.01), without difference in 30-day stroke between the 2 groups (OR 1.24, 95% CI 0.83 to 1.88, p = 0.30). In conclusion, this report indicates that TAVR is safe and feasible in patients with BAV, including patients at low surgical risk. The higher rate of 30-day stroke, however, warrants caution when pursuing TAVR in this population. More studies, specifically randomized trials, are still warranted to further assess the safety and the long-term outcomes in this group.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Tricúspide , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Válvula Aórtica/cirugía , Estenosis de la Válvula Tricúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Accidente Cerebrovascular/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...