Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cureus ; 11(10): e6014, 2019 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-31815078

RESUMEN

Introduction Image-guided robotic radiosurgery is an emerging minimally-invasive treatment option for trigeminal neuralgia (TN). Our group has treated 560 cases up to date, and report here the clinical outcomes of 387 treatments with three years follow-up. This study represents the largest single-center experience on CyberKnife radiosurgery for the treatment of TN so far reported. Methods CyberKnife radiosurgery treatment was offered to patients with drug-resistant TN, after the failure of other treatments or refusal of invasive procedures. A second treatment was offered to patients with a poor response after the first treatment or with recurrent pain. Treatment protocol required the non-isocentric delivery of 60 Gy prescribed to the 80% isodose to a 6 mm retrogasserian segment of the affected trigeminal nerve. Retreatments typically received 45 Gy, again prescribed to the 80% isodose. The final plan was developed accordingly to individual anatomy and dose distribution over the trigeminal nerve, gasserian ganglion, and brainstem. Clinical outcomes such as pain control and hypoesthesia/numbness have been evaluated after 6, 12, 24, and 36 months.  Results Our group has treated 527 patients with Cyberknife radiosurgery at Centro Diagnostico Italiano (CDI), Milan, Italy, during the last decade. A minimum follow-up of six months was available on 496 patients. These patients received 560 treatments: 435 patients (87.7%) had a single treatment, 60 patients (12.1%) had two treatments, and one patient (0.2%) had five treatments (two on the right side, three on the left side). Twenty four patients had multiple sclerosis (4.8%). Four hundred and forty-three patients (84%) received the treatment without previous procedures, while 84 patients (16%) underwent radiosurgery after the failure of other treatments. A neurovascular conflict was identified in 59% of the patients. Three hundred and forty-three patients (receiving a total of 387 treatments) had a minimum of 36 months follow up. Pain relief rate at 6, 12, 18, 24, 30 and 36 months was respectively 92, 87, 87, 82, 78 and 76%. Forty-four patients out of 343 (12.8%) required a second treatment during the observed period. At 36 months post-treatment, 21 patients (6,1%) reported the presence of bothering facial hypoesthesia. Eighteen patients out of 21 (85.7%) developed this complication after a repeated treatment.  Conclusions Frameless image-guided robotic radiosurgery in experienced hands is a safe and effective procedure for the treatment of TN, providing excellent pain control rates in the absence of major neurological complications. Repeated treatments due to recurrent pain are associated with restored pain control but at the price of a higher rate of sensory complications.

2.
Phys Med ; 59: 47-54, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30928065

RESUMEN

PURPOSE: When a lung lesion is detected by only one couple of X-ray tube and image detector integrated with CyberKnife®, the fiducial-less tracking is limited to 1-view (34% of lung treatments at Centro Diagnostico Italiano). The aim of the study was mainly to determine the margin needed to take into account the localization uncertainty along the blind view (out-of-plane direction). METHODS: 36 patients treated in 2-view tracking modality (127 fractions in total) were included in the study. The actual tumor positions were determined retrospectively through logfile analysis and were projected onto 2D image planes. In the same plots the planned target positions based on biphasic breath-hold CT scans were represented preserving the metric with respect to the imaging center. The internal margin necessary to cover in out-of-plane direction the 95% of the target position distribution in the 95% of cases was calculated by home-made software in Matlab®. A validation test was preliminarily performed using XLT Phantom (CIRS) both in 2-view and 1-view scenarios. RESULTS: The validation test proved the reliability of the method, in spite of some intrinsic limitations. Margins were estimated equal to 5 and 6 mm for targets in upper and lower lobe respectively. Biphasic breath-hold CT led to underestimate the target movement in the hypothetical out-of-plane direction. The inter-fractional variability of spine-target distance was an important source of uncertainty for 1-view treatments. CONCLUSION: This graphic comparison method preserving metric could be employed in the clinical workflow of 1-view treatments to get patient-related information for customized margin definition.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Radiocirugia , Procedimientos Quirúrgicos Robotizados , Contencion de la Respiración , Fraccionamiento de la Dosis de Radiación , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/fisiopatología , Fantasmas de Imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Incertidumbre
3.
Phys Med ; 32(4): 575-81, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27050172

RESUMEN

PURPOSE: The aim of the present work was to evaluate small field size output factors (OFs) using the latest diamond detector commercially available, PTW-60019 microDiamond, over different CyberKnife systems. OFs were measured also by silicon detectors routinely used by each center, considered as reference. METHODS: Five Italian CyberKnife centers performed OFs measurements for field sizes ranging from 5 to 60mm, defined by fixed circular collimators (5 centers) and by Iris(™) variable aperture collimator (4 centers). Setup conditions were: 80cm source to detector distance, and 1.5cm depth in water. To speed up measurements two diamond detectors were used and their equivalence was evaluated. MonteCarlo (MC) correction factors for silicon detectors were used for comparing the OF measurements. RESULTS: Considering OFs values averaged over all centers, diamond data resulted lower than uncorrected silicon diode ones. The agreement between diamond and MC corrected silicon values was within 0.6% for all fixed circular collimators. Relative differences between microDiamond and MC corrected silicon diodes data for Iris(™) collimator were lower than 1.0% for all apertures in the totality of centers. The two microDiamond detectors showed similar characteristics, in agreement with the technical specifications. CONCLUSIONS: Excellent agreement between microDiamond and MC corrected silicon diode detectors OFs was obtained for both collimation systems fixed cones and Iris(™), demonstrating the microDiamond could be a suitable detector for CyberKnife commissioning and routine checks. These results obtained in five centers suggest that for CyberKnife systems microDiamond can be used without corrections even at the smallest field size.


Asunto(s)
Radiocirugia/instrumentación , Interpretación Estadística de Datos , Diamante/química , Humanos , Radiometría/métodos , Radiocirugia/métodos , Silicio/química
4.
Radiat Oncol ; 10: 132, 2015 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-26071401

RESUMEN

BACKGROUND: A multidisciplinary and multi-institutional working group applied the Failure Mode and Effects Analysis (FMEA) approach to assess the risks for patients undergoing Stereotactic Body Radiation Therapy (SBRT) treatments for lesions located in spine and liver in two CyberKnife® Centres. METHODS: The various sub-processes characterizing the SBRT treatment were identified to generate the process trees of both the treatment planning and delivery phases. This analysis drove to the identification and subsequent scoring of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system. Novel solutions aimed to increase patient safety were accordingly considered. RESULTS: The process-tree characterising the SBRT treatment planning stage was composed with a total of 48 sub-processes. Similarly, 42 sub-processes were identified in the stage of delivery to liver tumours and 30 in the stage of delivery to spine lesions. All the sub-processes were judged to be potentially prone to one or more failure modes. Nineteen failures (i.e. 5 in treatment planning stage, 5 in the delivery to liver lesions and 9 in the delivery to spine lesions) were considered of high concern in view of the high RPN and/or severity index value. CONCLUSIONS: The analysis of the potential failures, their causes and effects allowed to improve the safety strategies already adopted in the clinical practice with additional measures for optimizing quality management workflow and increasing patient safety.


Asunto(s)
Análisis de Modo y Efecto de Fallas en la Atención de la Salud , Neoplasias Hepáticas/cirugía , Radiocirugia , Neoplasias de la Columna Vertebral/cirugía , Humanos , Italia , Errores Médicos , Seguridad del Paciente , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Radiocirugia/efectos adversos , Radiocirugia/instrumentación , Riesgo , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...