1.
Interact Cardiovasc Thorac Surg ; 6(5): 658-60, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17670722

RESUMEN

Acute thrombosis of an abdominal aortic aneurysm is a rare but devastating surgical emergency. We present the first case of a patient with sudden thrombosis of an AAA delayed (more than 24 h) after removal of an intra-aortic balloon pump. Treatment options include open surgical repair, axillobifemoral grafting or endovascular aortic repair. The patient received an aorto-bifemoral graft. The associations between intra-aortic balloon pump counter-pulsation and abdominal aortic thrombosis are discussed.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico , Puente de Arteria Coronaria , Estenosis Coronaria/cirugía , Contrapulsador Intraaórtico/efectos adversos , Trombosis/etiología , Enfermedad Aguda , Anciano , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Estenosis Coronaria/complicaciones , Humanos , Masculino , Trombosis/diagnóstico por imagen , Trombosis/cirugía , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares