Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Hybrid Imaging ; 5(1): 4, 2021 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-34181120

RESUMEN

PURPOSE: To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty. METHODS: A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/radiologic follow-up at a minimum of 1 year was used as the reference standard. RESULTS: The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%), respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%). CONCLUSION: SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.

2.
J Arthroplasty ; 30(9): 1647-51, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25861919

RESUMEN

Aseptic loosening represents the most common complication associated with hip and knee arthroplasty and is a common indication for surgical revision in the post-arthroplasty population. The optimal imaging methodology in evaluating clinical suspected loosening is not well-defined. Our study retrospectively evaluated nuclear medicine arthrography with hybrid single photon emission computed tomography/computed tomography (SPECT/CT) in 38 patients (21 hip, 17 knee) compared with reference standards of surgical evaluation, spontaneous resolution of symptoms without revision, or a minimum of 1 year clinical and radiographic follow-up. Our study demonstrated a sensitivity of 100%, specificity of 96.0%, PPV of 92.9%, NPV of 100%, and accuracy of 97.4% with this imaging technique suggesting utility of nuclear medicine arthrography with SPECT/CT in the clinical evaluation of suspected aseptic loosening.


Asunto(s)
Artrografía/métodos , Prótesis de la Rodilla , Tomografía Computarizada de Emisión de Fotón Único , Artroplastia de Reemplazo de Rodilla , Humanos , Articulación de la Rodilla , Valor Predictivo de las Pruebas , Falla de Prótesis , Reoperación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
3.
BMC Musculoskelet Disord ; 15: 192, 2014 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-24889213

RESUMEN

BACKGROUND: Total Hip Arthroplasty (THA) is being used more commonly in younger higher demand patients. The purpose of this randomized pilot study was to explore a) feasibility of comprehensive postoperative rehabilitation compared to usual care following primary THA in subjects <65 years, b) appropriate outcome measures including performance-based measures and c) timing of assessments. METHODS: 21 subjects who underwent primary THA were randomized to receive a three-month out-patient rehabilitation program (Intervention) or usual postoperative care (Control). Subjects were assessed preoperatively, six-weeks postoperatively (Pre-intervention) and four and 12 months postoperatively (Post-intervention). Self-report measures were the Western Ontario McMaster Osteoarthritis Index (WOMAC) and Rand 36-Item Health Survey (RAND-36). Performance-based measures included lower extremity strength, walking speed and endurance, and gait laboratory assessment. RESULTS: Ten Control and 11 Intervention subjects with an average age of 53.4 (SD9.3) years were randomized. All Intervention subjects completed the program without adverse effects. Although no statistically significantly results were reported, four months postoperatively, Intervention subjects had clinically important differences (CID) in strength compared with Control subjects. Walking endurance, WOMAC and RAND scores improved significantly with no CID noted between groups. Ten (48%) subjects reported a ceiling effect on the WOMAC (9 (43%) subjects on Pain; 1 (5%) subject on Function). No group CID were noted in gait measures. CONCLUSIONS: Our recommendations would be that performance-based strength measures should be considered for the primary outcome in this younger cohort. Because of the ceiling effects with WOMAC Pain, a different pain measure is indicated. Other more challenging functional performance-based tests should be considered such as a more prolonged endurance test. There is merit in one-year follow-up as strength improved after four months in both groups.


Asunto(s)
Artroplastia de Reemplazo de Cadera/rehabilitación , Terapia por Ejercicio , Cuidados Posteriores , Factores de Edad , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fuerza Muscular , Osteoartritis de la Cadera/rehabilitación , Osteoartritis de la Cadera/cirugía , Dolor Postoperatorio/epidemiología , Proyectos Piloto , Rango del Movimiento Articular , Índice de Severidad de la Enfermedad , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento , Caminata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...