Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Chem ; 7: 88, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30859096

RESUMEN

This study analyzes the mapping of temperature distribution generated by graphene in a glass slide cover after illumination at 808 nm with a good thermal resolution. For this purpose, Er,Yb:NaYF4 nanoparticles prepared by a microwave-assisted solvothermal method were used as upconversion luminescent nanothermometers. By tuning the basic parameters of the synthesis procedure, such as the time and temperature of reaction and the concentration of ethanol and water, we were able to control the size and the crystalline phase of the nanoparticles, and to have the right conditions to obtain 100% of the ß hexagonal phase, the most efficient spectroscopically. We observed that the thermal sensitivity that can be achieved with these particles is a function of the size of the nanoparticles and the crystalline phase in which they crystallize. We believe that, with suitable changes, these nanoparticles might be used in the future to map temperature gradients in living cells while maintaining a good thermal resolution.

2.
Sci Rep ; 7(1): 3677, 2017 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-28623262

RESUMEN

Metastatic cancer patients require a continuous monitoring during the sequential treatment cycles to carefully evaluate their disease evolution. Repetition of biopsies is very invasive and not always feasible. Herein, we design and demonstrate a 3D-flow focusing microfluidic device, where all optics are integrated into the chip, for the fluorescence quantification of CTCs in real samples. To test the chip performance, two cell membrane targets, the epithelial cell adhesion molecule, EpCAM, and the receptor tyrosine-protein kinase, HER2, are selected. The efficiency of the platform is demonstrated on cell lines and in a variety of healthy donors and metastatic-breast cancer patients.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/métodos , Células Neoplásicas Circulantes/patología , Adulto , Anciano , Biomarcadores , Biomarcadores de Tumor , Neoplasias de la Mama/metabolismo , Estudios de Casos y Controles , Línea Celular Tumoral , Progresión de la Enfermedad , Femenino , Técnica del Anticuerpo Fluorescente , Humanos , Imagen por Resonancia Magnética/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Persona de Mediana Edad , Metástasis de la Neoplasia , Células Neoplásicas Circulantes/metabolismo
3.
Opt Express ; 16(7): 5022-34, 2008 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-18542603

RESUMEN

Thermal analysis of the monoclinic solid state laser host KLu(WO4)2 is presented. The specific heat was measured by the relaxation method in the temperature range from 1.9 to 385 K: its value at room temperature is 0.324 J/gK. The Debye temperature and the sound velocity amount to 303+/-3 K and 3734 m/s. The linear thermal expansion tensor was measured by X-ray powder diffraction from room temperature up to 773 K. The eigenvalues of this tensor are alpha'(11)=8.98 x 10(-6) K(-1), alpha'(22)=3.35 x 10(-6) K(-1), and alpha'(33)=16.72 x 10(-6) K(-1), with the maximum value in the a-b crystallographic plane, at 31.94 degrees from the N(g) principal optical axis. The thermal diffusivity and its anisotropy in the temperature range between 300 and 500 K were measured by the pyroelectric method to determine the thermal conductivity tensor. The eigenvalues of the thermal conductivity are kappa'(11)=2.95 Wm(-1)K(-1), kappa'(22)=2.36 Wm-1K-1, and kappa'(33)=4.06 Wm(-1)K(-1), with the maximum value along a direction again in the a-b crystallographic plane, at 40.75 degrees from the N(g) principal optical axis. Simulation of the temperature distribution in a bulk sample of KLu(WO4)2 with dimensions 3 x 3 x 3 mm(3) shows that pump and laser beam directions along the N(p) principal optical axis in terms of thermal effects are preferable because the propagation is along a quasi-isothermal path.


Asunto(s)
Láseres de Estado Sólido , Diseño de Equipo , Análisis de Falla de Equipo , Lutecio/química , Potasio/química , Temperatura , Conductividad Térmica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...