JACC Clin Electrophysiol ; 5(12): 1459-1472, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31857047

RESUMEN

OBJECTIVES: A new electroanatomic mapping system (Rhythmia, Boston Scientific, Marlborough, Massachusetts) using a 64-electrode mapping basket is now available; we systematically assessed its use in complex congenital heart disease (CHD). BACKGROUND: The incidence of atrial arrhythmias post-surgery for CHD is high. Catheter ablation has emerged as an effective treatment, but is hampered by limitations in the mapping system's ability to accurately define the tachycardia circuit. METHODS: Mapping and ablation data of 61 patients with CHD (35 males, age 45 ± 14 years) from 8 tertiary centers were reviewed. RESULTS: Causes were as follows: Transposition of Great Arteries (atrial switch) (n = 7); univentricular physiology (Fontans) (n = 8); Tetralogy of Fallot (n = 10); atrial septal defect (ASD) repair (n = 15); tricuspid valve (TV) anomalies (n = 10); and other (n = 11). The total number of atrial arrhythmias was 86. Circuits were predominantly around the tricuspid valve (n = 37), atriotomy scar (n = 10), or ASD patch (n = 4). Although the majority of peri-tricuspid circuits were cavo-tricuspid-isthmus dependent (n = 30), they could follow a complex route between the annulus and septal resection, ASD patch, coronary sinus, or atriotomy. Immediate ablation success was achieved in all but 2 cases; with follow-up of 12 ± 8 months, 7 patients had recurrence. CONCLUSIONS: We demonstrate the feasibility of the basket catheter for mapping complex CHD arrhythmias, including with transbaffle and transhepatic access. Although the circuits often involve predictable anatomic landmarks, the precise critical isthmus is often difficult to predict empirically. Ultra-high-density mapping enables elucidation of circuits in this complex anatomy and allows successful treatment at the isthmus with a minimal lesion set.


Asunto(s)
Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Cardiopatías Congénitas , Taquicardia , Adulto , Anciano , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Diseño de Equipo , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia/diagnóstico por imagen , Taquicardia/etiología , Taquicardia/fisiopatología
2.
Circ Arrhythm Electrophysiol ; 12(12): e006857, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31760821

RESUMEN

BACKGROUND: Various strategies for ablation of ventricular tachycardia (VT) have been described, but their impact on ventricular fibrillation (VF) is largely unknown. The aim of our study was to assess the effect of substrate-based VT ablation targeting local abnormal ventricular activity (LAVA) on recurrent VF events in patients with structural heart disease. METHODS: A retrospective 2-center study was performed on patients with structural heart disease and both VT and VF, with incident VT ablation procedures targeting LAVAs. Generalized estimating equations with a Poisson loglinear model were used to assess the impact of catheter ablation on VF episodes. The change in VF events before and after catheter ablation was compared with matched controls without ablation. RESULTS: From a total of 686 patients with an incident VT ablation procedure targeting LAVAs, 21 patients (age, 57±14 years; left ventricular ejection fraction, 30±10%) had both VT and VF and met inclusion criteria. A total of 80 VF events were recorded in the implantable cardioverter-defibrillator logs the 6 months preceding ablation. Complete and partial LAVA elimination was achieved in 11 (52%) and 10 (48%) patients, respectively. Catheter ablation was associated with a highly significant reduction in VF recurrences (P<0.0001), which were limited to 3 (14%) patients at 6 months. The total number of VF events thereby decreased from 80 to 3, from a median of 1.0 (range, 1-29) to 0.0 (range, 0-1) in the 6 months before and after ablation, respectively. The reduction in VF events was significantly greater in patients with catheter ablation compared with 21 matched controls during 6-month periods following and preceding a baseline assessment (Poisson ß-coefficient, 1.39; P=0.0003). CONCLUSIONS: Substrate-guided VT ablation targeting LAVAs may be associated with a significant reduction in recurrent VF, suggesting that VT and VF share overlapping arrhythmogenic substrates in patients with structural heart disease.


Asunto(s)
Ablación por Catéter/efectos adversos , Frecuencia Cardíaca , Taquicardia Ventricular/cirugía , Fibrilación Ventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Femenino , Francia/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/fisiopatología