Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Eur Radiol ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38789792

RESUMEN

BACKGROUND: The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on photon counting CT (PCCT) for coronary artery calcium (CAC) scoring, and second, to assess the feasibility of calculating CAC scores from CCTA, in comparison to reference calcium scoring CT (CSCT) scans. METHODS: In this phantom study, an artificial coronary artery was translated at velocities corresponding to 0, < 60, and 60-75 beats per minute (bpm) within an anthropomorphic phantom. The density of calcifications was 100 (very low), 200 (low), 400 (medium), and 800 (high) mgHA/cm3, respectively. CCTA was reconstructed with the following parameters: virtual non-iodine (VNI), with and without iterative reconstruction (QIR level 2, QIR off, respectively); kernels Qr36 and Qr44f; slice thickness/increment 3.0/1.5 mm and 0.4/0.2 mm. The agreement in risk group classification between CACCCTA and CACCSCT scoring was measured using Cohen weighted linear κ with 95% CI. RESULTS: For CCTA reconstructed with 0.4 mm slice thickness, calcium detectability was perfect (100%). At < 60 bpm, CACCCTA of low, and medium density calcification was underestimated by 53%, and 15%, respectively. However, CACCCTA was not significantly different from CACCSCT of very low, and high-density calcifications. The best risk agreement was achieved when CCTA was reconstructed with QIR off, Qr44f, and 0.4 mm slice thickness (κ = 0.762, 95% CI 0.671-0.853). CONCLUSION: In this dynamic phantom study, the detection of calcifications with different densities was excellent with CCTA on PCCT using thin-slice VNI reconstruction. Agatston scores were underestimated compared to CSCT but agreement in risk classification was substantial. CLINICAL RELEVANCE STATEMENT: Photon counting CT may enable the implementation of coronary artery calcium scoring from coronary CTA in daily clinical practice. KEY POINTS: Photon-counting CTA allows for excellent detectability of low-density calcifications at all heart rates. Coronary artery calcium scoring from coronary CTA acquired on photon counting CT is feasible, although improvement is needed. Adoption of the standard acquisition and reconstruction protocol for calcium scoring is needed for improved quantification of coronary artery calcium to fully employ the potential of photon counting CT.

2.
Radiol Cardiothorac Imaging ; 6(2): e240020, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38602468

RESUMEN

Radiology: Cardiothoracic Imaging publishes novel research and technical developments in cardiac, thoracic, and vascular imaging. The journal published many innovative studies during 2023 and achieved an impact factor for the first time since its inaugural issue in 2019, with an impact factor of 7.0. The current review article, led by the Radiology: Cardiothoracic Imaging trainee editorial board, highlights the most impactful articles published in the journal between November 2022 and October 2023. The review encompasses various aspects of coronary CT, photon-counting detector CT, PET/MRI, cardiac MRI, congenital heart disease, vascular imaging, thoracic imaging, artificial intelligence, and health services research. Key highlights include the potential for photon-counting detector CT to reduce contrast media volumes, utility of combined PET/MRI in the evaluation of cardiac sarcoidosis, the prognostic value of left atrial late gadolinium enhancement at MRI in predicting incident atrial fibrillation, the utility of an artificial intelligence tool to optimize detection of incidental pulmonary embolism, and standardization of medical terminology for cardiac CT. Ongoing research and future directions include evaluation of novel PET tracers for assessment of myocardial fibrosis, deployment of AI tools in clinical cardiovascular imaging workflows, and growing awareness of the need to improve environmental sustainability in imaging. Keywords: Coronary CT, Photon-counting Detector CT, PET/MRI, Cardiac MRI, Congenital Heart Disease, Vascular Imaging, Thoracic Imaging, Artificial Intelligence, Health Services Research © RSNA, 2024.


Asunto(s)
Apéndice Atrial , Cardiopatías Congénitas , Radiología , Humanos , Medios de Contraste , Inteligencia Artificial , Gadolinio , Tomografía Computarizada por Rayos X
3.
Radiol Med ; 129(5): 712-726, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38538828

RESUMEN

Treatment response assessment of rectal cancer patients is a critical component of personalized cancer care and it allows to identify suitable candidates for organ-preserving strategies. This pilot study employed a novel multi-omics approach combining MRI-based radiomic features and untargeted metabolomics to infer treatment response at staging. The metabolic signature highlighted how tumor cell viability is predictively down-regulated, while the response to oxidative stress was up-regulated in responder patients, showing significantly reduced oxoproline values at baseline compared to non-responder patients (p-value < 10-4). Tumors with a high degree of texture homogeneity, as assessed by radiomics, were more likely to achieve a major pathological response (p-value < 10-3). A machine learning classifier was implemented to summarize the multi-omics information and discriminate responders and non-responders. Combining all available radiomic and metabolomic features, the classifier delivered an AUC of 0.864 (± 0.083, p-value < 10-3) with a best-point sensitivity of 90.9% and a specificity of 81.8%. Our results suggest that a multi-omics approach, integrating radiomics and metabolomic data, can enhance the predictive value of standard MRI and could help to avoid unnecessary surgical treatments and their associated long-term complications.


Asunto(s)
Imagen por Resonancia Magnética , Metabolómica , Estadificación de Neoplasias , Neoplasias del Recto , Humanos , Proyectos Piloto , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/patología , Neoplasias del Recto/terapia , Masculino , Femenino , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Anciano , Resultado del Tratamiento , Aprendizaje Automático , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Adulto , Multiómica
4.
Radiol Artif Intell ; 6(2): e230153, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38416035

RESUMEN

Coronary CT angiography is increasingly used for cardiac diagnosis. Dose modulation techniques can reduce radiation dose, but resulting functional images are noisy and challenging for functional analysis. This retrospective study describes and evaluates a deep learning method for denoising functional cardiac imaging, taking advantage of multiphase information in a three-dimensional convolutional neural network. Coronary CT angiograms (n = 566) were used to derive synthetic data for training. Deep learning-based image denoising was compared with unprocessed images and a standard noise reduction algorithm (block-matching and three-dimensional filtering [BM3D]). Noise and signal-to-noise ratio measurements, as well as expert evaluation of image quality, were performed. To validate the use of the denoised images for cardiac quantification, threshold-based segmentation was performed, and results were compared with manual measurements on unprocessed images. Deep learning-based denoised images showed significantly improved noise compared with standard denoising-based images (SD of left ventricular blood pool, 20.3 HU ± 42.5 [SD] vs 33.4 HU ± 39.8 for deep learning-based image denoising vs BM3D; P < .0001). Expert evaluations of image quality were significantly higher in deep learning-based denoised images compared with standard denoising. Semiautomatic left ventricular size measurements on deep learning-based denoised images showed excellent correlation with expert quantification on unprocessed images (intraclass correlation coefficient, 0.97). Deep learning-based denoising using a three-dimensional approach resulted in excellent denoising performance and facilitated valid automatic processing of cardiac functional imaging. Keywords: Cardiac CT Angiography, Deep Learning, Image Denoising Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Angiografía por Tomografía Computarizada , Aprendizaje Profundo , Angiografía por Tomografía Computarizada/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria
5.
Circulation ; 149(6): e296-e311, 2024 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-38193315

RESUMEN

Multiple applications for machine learning and artificial intelligence (AI) in cardiovascular imaging are being proposed and developed. However, the processes involved in implementing AI in cardiovascular imaging are highly diverse, varying by imaging modality, patient subtype, features to be extracted and analyzed, and clinical application. This article establishes a framework that defines value from an organizational perspective, followed by value chain analysis to identify the activities in which AI might produce the greatest incremental value creation. The various perspectives that should be considered are highlighted, including clinicians, imagers, hospitals, patients, and payers. Integrating the perspectives of all health care stakeholders is critical for creating value and ensuring the successful deployment of AI tools in a real-world setting. Different AI tools are summarized, along with the unique aspects of AI applications to various cardiac imaging modalities, including cardiac computed tomography, magnetic resonance imaging, and positron emission tomography. AI is applicable and has the potential to add value to cardiovascular imaging at every step along the patient journey, from selecting the more appropriate test to optimizing image acquisition and analysis, interpreting the results for classification and diagnosis, and predicting the risk for major adverse cardiac events.


Asunto(s)
American Heart Association , Inteligencia Artificial , Humanos , Aprendizaje Automático , Corazón , Imagen por Resonancia Magnética
6.
Heliyon ; 9(10): e20575, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37842578

RESUMEN

The left atrial auricle (LAA) is the main source of intracardiac thrombi, which contribute significantly to the total number of stroke cases. It is also considered a major site of origin for atrial fibrillation in patients undergoing ablation procedures. The LAA is known to have a high degree of morphological variability, with shape and structure identified as important contributors to thrombus formation. A detailed understanding of LAA form, dimension, and function is crucial for radiologists, cardiologists, and cardiac surgeons. This review describes the normal anatomy of the LAA as visualized through multiple imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and echocardiography. Special emphasis is devoted to a discussion on how the morphological characteristics of the LAA are closely related to the likelihood of developing LAA thrombi, including insights into LAA embryology.

7.
Abdom Radiol (NY) ; 48(11): 3537-3549, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37665385

RESUMEN

PURPOSE: To develop and assess the utility of synthetic dual-energy CT (sDECT) images generated from single-energy CT (SECT) using two state-of-the-art generative adversarial network (GAN) architectures for artificial intelligence-based image translation. METHODS: In this retrospective study, 734 patients (389F; 62.8 years ± 14.9) who underwent enhanced DECT of the chest, abdomen, and pelvis between January 2018 and June 2019 were included. Using 70-keV as the input images (n = 141,009) and 50-keV, iodine, and virtual unenhanced (VUE) images as outputs, separate models were trained using Pix2PixHD and CycleGAN. Model performance on the test set (n = 17,839) was evaluated using mean squared error, structural similarity index, and peak signal-to-noise ratio. To objectively test the utility of these models, synthetic iodine material density and 50-keV images were generated from SECT images of 16 patients with gastrointestinal bleeding performed at another institution. The conspicuity of gastrointestinal bleeding using sDECT was compared to portal venous phase SECT. Synthetic VUE images were generated from 37 patients who underwent a CT urogram at another institution and model performance was compared to true unenhanced images. RESULTS: sDECT from both Pix2PixHD and CycleGAN were qualitatively indistinguishable from true DECT by a board-certified radiologist (avg accuracy 64.5%). Pix2PixHD had better quantitative performance compared to CycleGAN (e.g., structural similarity index for iodine: 87% vs. 46%, p-value < 0.001). sDECT using Pix2PixHD showed increased bleeding conspicuity for gastrointestinal bleeding and better removal of iodine on synthetic VUE compared to CycleGAN. CONCLUSIONS: sDECT from SECT using Pix2PixHD may afford some of the advantages of DECT.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Medios de Contraste , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Inteligencia Artificial , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Hemorragia Gastrointestinal
8.
Radiol Cardiothorac Imaging ; 5(3): e230042, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37404783

RESUMEN

Since its inaugural issue in 2019, Radiology: Cardiothoracic Imaging has disseminated the latest scientific advances and technical developments in cardiac, vascular, and thoracic imaging. In this review, we highlight select articles published in this journal between October 2021 and October 2022. The scope of the review encompasses various aspects of coronary artery and congenital heart diseases, vascular diseases, thoracic imaging, and health services research. Key highlights include changes in the revised Coronary Artery Disease Reporting and Data System 2.0, the value of coronary CT angiography in informing prognosis and guiding treatment decisions, cardiac MRI findings after COVID-19 vaccination or infection, high-risk features at CT angiography to identify patients with aortic dissection at risk for late adverse events, and CT-guided fiducial marker placement for preoperative planning for pulmonary nodules. Ongoing research and future directions include photon-counting CT and artificial intelligence applications in cardiovascular imaging. Keywords: Pediatrics, CT Angiography, CT-Perfusion, CT-Spectral Imaging, MR Angiography, PET/CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Pulmonary, Vascular, Aorta, Coronary Arteries © RSNA, 2023.

9.
Acad Radiol ; 30(12): 2825-2833, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37147161

RESUMEN

RATIONALE AND OBJECTIVES: Post-TAVR persistent pulmonary hypertension (PH) is a better predictor of poor outcome than pre-TAVR PH. In this longitudinal study we sought to evaluate whether pulmonary artery (distensibility (DPA) measured on preprocedural ECG-gated CTA is associated with persistent-PH and 2-year mortality after TAVR. MATERIALS AND METHODS: Three hundred and thirty-six patients undergoing TAVR between July 2012 and March 2016 were retrospectively included and followed for all-cause mortality until November 2017. All patients underwent retrospectively ECG-gated CTA prior to TAVR. Main pulmonary artery (MPA) area was measured in systole and in diastole. DPA was calculated as: [(area-MPAmax-area-MPAmin)/area-MPAmax]%. ROC analysis was performed to assess the AUC for persistent-PH. Youden Index was used to determine the optimal threshold of DPA for persistent-PH. Two groups were compared based on a DPA threshold of 8% (specificity of 70% for persistent-PH). Kaplan-Meier, Cox proportional-hazard, and logistic regression analyses were performed. The primary clinical endpoint was defined as persistent-PH post-TAVR. The secondary endpoint was defined as all-cause mortality 2 years after TAVR. RESULTS: Median follow-up time was 413 (interquartiles 339-757) days. A total of 183 (54%) had persistent-PH and 68 (20%) patients died within 2-years after TAVR. Patients with DPA<8% had significantly more persistent-PH (67% vs 47%, p<0.001) and 2-year deaths (28% vs 15%, p=0.006), compared to patients with DPA>8%. Adjusted multivariable regression analyses showed that DPA<8% was independently associated with persistent-PH (OR 2.10 [95%-CI 1.3-4.5], p=0.007) and 2-year mortality (HR 2.91 [95%-CI 1.5-5.8], p=0.002). Kaplan-Meier analysis showed that 2-year mortality of patients with DPA<8% was significantly higher compared to patients with DPA≥8% (mortality 28% vs 15%; log-rank p=0.003). CONCLUSION: DPA on preprocedural CTA is independently associated with persistent-PH and two-year mortality in patients who undergo TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Hipertensión Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica , Arteria Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/complicaciones , Resultado del Tratamiento , Estudios Longitudinales , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
10.
Invest Radiol ; 58(7): 505-514, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-36822653

RESUMEN

ABSTRACT: Noninvasive cardiac imaging has rapidly evolved during the last decade owing to improvements in computed tomography (CT)-based technologies, among which we highlight the recent introduction of the first clinical photon-counting detector CT (PCD-CT) system. Multiple advantages of PCD-CT have been demonstrated, including increased spatial resolution, decreased electronic noise, and reduced radiation exposure, which may further improve diagnostics and may potentially impact existing management pathways. The benefits that can be obtained from the initial experiences with PCD-CT are promising. The implementation of this technology in cardiovascular imaging allows for the quantification of coronary calcium, myocardial extracellular volume, myocardial radiomics features, epicardial and pericoronary adipose tissue, and the qualitative assessment of coronary plaques and stents. This review aims to discuss these major applications of PCD-CT with a focus on cardiac and myocardial characterization.


Asunto(s)
Corazón , Tomografía Computarizada por Rayos X , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Miocardio , Fotones
11.
Radiology ; 306(3): e221257, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36719287

RESUMEN

Filtered back projection (FBP) has been the standard CT image reconstruction method for 4 decades. A simple, fast, and reliable technique, FBP has delivered high-quality images in several clinical applications. However, with faster and more advanced CT scanners, FBP has become increasingly obsolete. Higher image noise and more artifacts are especially noticeable in lower-dose CT imaging using FBP. This performance gap was partly addressed by model-based iterative reconstruction (MBIR). Yet, its "plastic" image appearance and long reconstruction times have limited widespread application. Hybrid iterative reconstruction partially addressed these limitations by blending FBP with MBIR and is currently the state-of-the-art reconstruction technique. In the past 5 years, deep learning reconstruction (DLR) techniques have become increasingly popular. DLR uses artificial intelligence to reconstruct high-quality images from lower-dose CT faster than MBIR. However, the performance of DLR algorithms relies on the quality of data used for model training. Higher-quality training data will become available with photon-counting CT scanners. At the same time, spectral data would greatly benefit from the computational abilities of DLR. This review presents an overview of the principles, technical approaches, and clinical applications of DLR, including metal artifact reduction algorithms. In addition, emerging applications and prospects are discussed.


Asunto(s)
Inteligencia Artificial , Aprendizaje Profundo , Humanos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
12.
J Digit Imaging ; 36(3): 1071-1080, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36698037

RESUMEN

Oncotype Dx Recurrence Score (RS) has been validated in patients with ER + /HER2 - invasive breast carcinoma to estimate patient risk of recurrence and guide the use of adjuvant chemotherapy. We investigated the role of MRI-based radiomics features extracted from the tumor and the peritumoral tissues to predict the risk of tumor recurrence. A total of 62 patients with biopsy-proved ER + /HER2 - breast cancer who underwent pre-treatment MRI and Oncotype Dx were included. An RS > 25 was considered discriminant between low-intermediate and high risk of tumor recurrence. Two readers segmented each tumor. Radiomics features were extracted from the tumor and the peritumoral tissues. Partial least square (PLS) regression was used as the multivariate machine learning algorithm. PLS ß-weights of radiomics features included the 5% features with the largest ß-weights in magnitude (top 5%). Leave-one-out nested cross-validation (nCV) was used to achieve hyperparameter optimization and evaluate the generalizable performance of the procedure. The diagnostic performance of the radiomics model was assessed through receiver operating characteristic (ROC) analysis. A null hypothesis probability threshold of 5% was chosen (p < 0.05). The exploratory analysis for the complete dataset revealed an average absolute correlation among features of 0.51. The nCV framework delivered an AUC of 0.76 (p = 1.1∙10-3). When combining "early" and "peak" DCE images of only T or TST, a tendency toward statistical significance was obtained for TST with an AUC of 0.61 (p = 0.05). The 47 features included in the top 5% were balanced between T and TST (23 and 24, respectively). Moreover, 33/47 (70%) were texture-related, and 25/47 (53%) were derived from high-resolution images (1 mm). A radiomics-based machine learning approach shows the potential to accurately predict the recurrence risk in early ER + /HER2 - breast cancer patients.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/patología , Curva ROC , Algoritmos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
13.
Circulation ; 147(9): 703-714, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36342823

RESUMEN

BACKGROUND: Coronary artery calcium (CAC) can be identified on nongated chest computed tomography (CT) scans, but this finding is not consistently incorporated into care. A deep learning algorithm enables opportunistic CAC screening of nongated chest CT scans. Our objective was to evaluate the effect of notifying clinicians and patients of incidental CAC on statin initiation. METHODS: NOTIFY-1 (Incidental Coronary Calcification Quality Improvement Project) was a randomized quality improvement project in the Stanford Health Care System. Patients without known atherosclerotic cardiovascular disease or a previous statin prescription were screened for CAC on a previous nongated chest CT scan from 2014 to 2019 using a validated deep learning algorithm with radiologist confirmation. Patients with incidental CAC were randomly assigned to notification of the primary care clinician and patient versus usual care. Notification included a patient-specific image of CAC and guideline recommendations regarding statin use. The primary outcome was statin prescription within 6 months. RESULTS: Among 2113 patients who met initial clinical inclusion criteria, CAC was identified by the algorithm in 424 patients. After chart review and additional exclusions were made, a radiologist confirmed CAC among 173 of 194 patients (89.2%) who were randomly assigned to notification or usual care. At 6 months, the statin prescription rate was 51.2% (44/86) in the notification arm versus 6.9% (6/87) with usual care (P<0.001). There was also more coronary artery disease testing in the notification arm (15.1% [13/86] versus 2.3% [2/87]; P=0.008). CONCLUSIONS: Opportunistic CAC screening of previous nongated chest CT scans followed by clinician and patient notification led to a significant increase in statin prescriptions. Further research is needed to determine whether this approach can reduce atherosclerotic cardiovascular disease events. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04789278.


Asunto(s)
Aterosclerosis , Enfermedades Cardiovasculares , Enfermedad de la Arteria Coronaria , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Calcificación Vascular , Humanos , Calcio , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Vasos Coronarios/diagnóstico por imagen , Factores de Riesgo , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/tratamiento farmacológico , Tomografía Computarizada por Rayos X , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/prevención & control , Medición de Riesgo
15.
Eur Radiol ; 33(2): 1102-1111, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36029344

RESUMEN

OBJECTIVES: Establishing the reproducibility of expert-derived measurements on CTA exams of aortic dissection is clinically important and paramount for ground-truth determination for machine learning. METHODS: Four independent observers retrospectively evaluated CTA exams of 72 patients with uncomplicated Stanford type B aortic dissection and assessed the reproducibility of a recently proposed combination of four morphologic risk predictors (maximum aortic diameter, false lumen circumferential angle, false lumen outflow, and intercostal arteries). For the first inter-observer variability assessment, 47 CTA scans from one aortic center were evaluated by expert-observer 1 in an unconstrained clinical assessment without a standardized workflow and compared to a composite of three expert-observers (observers 2-4) using a standardized workflow. A second inter-observer variability assessment on 30 out of the 47 CTA scans compared observers 3 and 4 with a constrained, standardized workflow. A third inter-observer variability assessment was done after specialized training and tested between observers 3 and 4 in an external population of 25 CTA scans. Inter-observer agreement was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. RESULTS: Pre-training ICCs of the four morphologic features ranged from 0.04 (-0.05 to 0.13) to 0.68 (0.49-0.81) between observer 1 and observers 2-4 and from 0.50 (0.32-0.69) to 0.89 (0.78-0.95) between observers 3 and 4. ICCs improved after training ranging from 0.69 (0.52-0.87) to 0.97 (0.94-0.99), and Bland-Altman analysis showed decreased bias and limits of agreement. CONCLUSIONS: Manual morphologic feature measurements on CTA images can be optimized resulting in improved inter-observer reliability. This is essential for robust ground-truth determination for machine learning models. KEY POINTS: • Clinical fashion manual measurements of aortic CTA imaging features showed poor inter-observer reproducibility. • A standardized workflow with standardized training resulted in substantial improvements with excellent inter-observer reproducibility. • Robust ground truth labels obtained manually with excellent inter-observer reproducibility are key to develop reliable machine learning models.


Asunto(s)
Disección Aórtica , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Disección Aórtica/diagnóstico por imagen , Aorta
16.
Radiographics ; 42(6): 1638-1653, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36190862

RESUMEN

Aortic dissection is a chronic disease that requires lifelong clinical and imaging surveillance, long after the acute event. Imaging has an important role in prognosis, timing of repair, device sizing, and monitoring for complications, especially in the endovascular therapy era. Important anatomic features at preprocedural imaging include the location of the primary intimal tear and aortic zonal and branch vessel involvement, which influence the treatment strategy. Challenges of repair in the chronic phase include a small true lumen in conjunction with a stiff intimal flap, complex anatomy, and retrograde perfusion from distal reentry tears. The role of thoracic endovascular aortic repair (TEVAR) remains controversial for treatment of chronic aortic dissection. Standard TEVAR is aimed at excluding the primary intimal tear to decrease false lumen perfusion, induce false lumen thrombosis, promote aortic remodeling, and prevent aortic growth. In addition to covering the primary intimal tear with an endograft, several adjunctive techniques have been developed to mitigate retrograde false lumen perfusion. These techniques are broadly categorized into false lumen obliteration and landing zone optimization strategies, such as the provisional extension to induce complete attachment (PETTICOAT), false lumen embolization, cheese-wire fenestration, and knickerbocker techniques. Familiarity with these techniques is important to recognize expected changes and complications at postintervention imaging. The authors detail imaging options, provide examples of simple and complex endovascular repairs of aortic dissections, and highlight complications that can be associated with various techniques. Online supplemental material is available for this article. ©RSNA, 2022.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Humanos , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento
17.
Semin Roentgenol ; 57(4): 345-356, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36265986

RESUMEN

Chronic aortic dissection comprises a heterogeneous group of unrepaired and repaired disease requiring lifelong clinical and imaging surveillance. CT and MRI are the main imaging modalities for longitudinal surveillance, with growing interest in emerging imaging techniques for prognostic potential. Imaging difficulties span technical and diagnostic challenges, some of which are unique to the repaired aorta, with specific complications depending on the type of repair. This review describes existing and emerging imaging techniques, outlines the technical and diagnostic challenges encountered at CT and MRI, and highlights the diagnostic pitfalls of chronic aortic dissection.


Asunto(s)
Disección Aórtica , Humanos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Imagen por Resonancia Magnética
19.
Acta Biomed ; 93(S1): e2022110, 2022 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-35671106

RESUMEN

Congenital heart diseases (CHD) represent a major clinical and diagnostic challenge for correct abnormality identification and subsequent successful therapy; even more challenging is following-up patient health after multiple post-interventional corrections often required in complex cardio-vascular abnormalities. We describe a multi-modality imaging evaluation of a complex congenital cardio-vascular diseases, underlining the relevance of cardiac magnetic resonance to non invasively solve some issues related to postsurgical changes.


Asunto(s)
Cardiopatías Congénitas , Enfermedades Vasculares , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos
20.
JACC Case Rep ; 4(10): 581-586, 2022 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-35615213

RESUMEN

We present the case of a 61-year-old man with tetralogy of Fallot postrepair and mechanical aortic valve replacement with an aortic root/ascending/arch aneurysm with chronic type A aortic dissection. He underwent uncomplicated aortic root and total arch replacement. Continued surveillance for aortic aneurysm is necessary in the tetralogy of Fallot population. (Level of Difficulty: Intermediate.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...