Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 618
Filtrar
1.
PLoS One ; 19(9): e0309614, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39250476

RESUMEN

Abnormally widened spatial and temporal binding windows (SBW/TBWs; length of space/time whereby stimuli are considered part of the same percept) are observed in schizophrenia. TBW alterations have been associated with altered sense of agency (hereafter referred to as agency), and an associative relationship between embodiment (body ownership) and agency has been proposed. SBWs/TBWs are investigated separately, but no evidence exists of these being separate in mechanism, system or function. The underlying neural substrate of schizophrenia remains unclear. The literature claims either pro-psychotic or anti-psychotic effects of Δ9-Tetrahydrocannabinol (THC) in patients and healthy individuals, but major support for cannabis in the aetiology of schizophrenia is associative, not causal. To clarify if THC is pro- or anti-psychotic, this single-blind, placebo-controlled within-subjects cross-over study tested several hypotheses. 1) Competing hypotheses that a synthetic THC analogue, Nabilone (NAB, 1-2 mg), would alter measures of agency and embodiment in healthy volunteers (n = 32) similarly, or opposite, to that of in patients with schizophrenia. 2) That there would be significant associations between any NAB-induced alterations in individual agency and embodiment measures in the Projected Hand Illusion (PHI). 3) That there is a unitary spatio-temporal binding window (STBW). A large proportion of individuals did not experience the PHI. Multimodal and bi-directional effects of NAB on the PHI were observed. Evidence of a unitary spatio-temporal binding window (STBW) was observed. NAB widened the STBW in some but narrowed it in others as a function of space and delay. No associations were found between agency and embodiment.


Asunto(s)
Dronabinol , Ilusiones , Humanos , Dronabinol/farmacología , Dronabinol/análogos & derivados , Adulto , Masculino , Femenino , Ilusiones/efectos de los fármacos , Adulto Joven , Mano , Estudios Cruzados , Esquizofrenia/tratamiento farmacológico , Método Simple Ciego
2.
J Prosthodont ; 2024 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-39307943

RESUMEN

PURPOSE: To study the effect of different vertical angulations on the ability to radiographically assess vertical marginal discrepancies of lithium disilicate crowns. MATERIALS AND METHODS: Twenty-one lithium disilicate crowns were fabricated for three different prepared natural teeth: incisor, canine, and premolar. Vertical marginal discrepancies ranging from 0 to 300 µm were intentionally created. The seated crowns were radiographed using seven different vertical angulations, totaling 147 images. Thirty experienced evaluators scored each image for marginal discrepancy, and values were statistically analyzed. RESULTS: Significant differences in the ability to accurately assess marginal discrepancies from radiographs were observed for the study factors of angulation, tooth type, and degree of marginal discrepancy (p < 0.001). CONCLUSIONS: The radiographic interpretation of the marginal discrepancies of lithium disilicate crowns is significantly affected by the dimension of the marginal discrepancy. Specifically on premolar crowns, it is significantly affected by different vertical angulations of the X-ray beam. When evaluating marginal discrepancy on lithium disilicate crowns radiographically, vertical beam angulation within ±10° to the cemento-enamel junctionCEJ plane is recommended.

3.
J Prosthodont ; 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39305506

RESUMEN

PURPOSE: The purpose of this study was to compare the effects of finishing and polishing techniques on the fit accuracy, metal loss, and surface roughness of conventional versus CAD-CAM removable partial denture (RPD) frameworks. MATERIALS AND METHODS: A 3D-printed maxillary Kennedy class III modification I model served as the master cast. Forty impressions (20 conventional and 20 digital) were divided into four groups: lost-wax technique (Group I: LWT), CAD-printed (Group II: CAD-RP), CAD-printed from a stone cast (Group III: CAD-RPS), and lost-wax technique from resin-printed models (Group IV: LWTR). Various finishing and polishing techniques were applied, followed by digital scanning for fit accuracy assessment using surface matching software. Metal thickness loss and surface roughness were evaluated pre- and post-finishing and polishing. The Kruskal-Wallis test followed by the Scheffe post-hoc test were conducted to evaluate the fit accuracy between groups (α = 0.05). RESULTS: Color mapping revealed significant differences (p < 0.001) between conventionally casted RPD frameworks and 3D-printed groups post-finishing and polishing. The most significant gap was observed with the guide plates from printed RPD frameworks. The D-Lyte technique resulted in less metal loss compared to the conventional finishing and polishing technique (p < 0.001). CONCLUSION: Within the limitations of this study, conventionally processed RPD groups exhibited better overall fit accuracy post-finishing and polishing. Both conventional cast and 3D-printed RPD frameworks showed clinically acceptable fit accuracy. The D-Lyte technique presented less metal loss and smoother surfaces compared to other groups, suggesting it as a viable alternative.

4.
BME Front ; 5: 0064, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39297176

RESUMEN

Objective: We conducted a comprehensive physicochemical analysis of one-dimensional ZnO nanowires (1DZnO), incorporating anti-CYFRA 21-1 immobilization to promote fast optical biomarker detection up to 10 ng ml-1. Impact Statement: This study highlights the effectiveness of proof-of-concept 1DZnO nanoplatforms for rapid cancer biomarker detection by examining the nanoscale integration of 1DZnO with these bioreceptors to deliver reliable photoluminescent output signals. Introduction: The urgent need for swift and accurate prognoses in healthcare settings drives the rise of sensitive biosensing nanoplatforms for cancer detection, which has benefited from biomarker identification. CYFRA 21-1 is a reliable target for the early prediction of cancer formation that can be perceptible in blood, saliva, and serum. However, 1DZnO nanostructures have been barely applied for CYFRA 21-1 detection. Methods: We assessed the nanoscale interaction between 1DZnO and anti-CYFRA 21-1 antibodies to develop rapid CYFRA 21-1 detection in two distinct matrices: PhosphateBuffered Saline (PBS) buffer and artificial saliva. The chemical modifications were tracked utilizing Fourier transform infrared spectroscopy, while transmission electron microscopy and energy dispersive spectroscopy confirmed antigen-antibody interplay over nanostructures. Results: Our results show high antibody immobilization efficiencies, affirming the effectiveness of 1DZnO nanoplatforms for rapid CYFRA 21-1 testing within a 5-min detection window in both PBS and artificial saliva. Photoluminescence measurements also revealed distinct optical responses across biomarker concentrations ranging from 10 to 1,000 ng ml-1. Conclusion: Discernible PL signal responses obtained after 5 min affirm the potential of 1DZnO nanoplatforms for further advancement in optical biomarker detection for application in early cancer prognosis.

5.
J Prosthet Dent ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39168756

RESUMEN

STATEMENT OF PROBLEM: Screw loosening remains one of the most common complications associated with implant-supported restorations. The available literature is scarce regarding the most efficient method of tightening definitive abutment screws for angled screw channel (ASC) abutments. PURPOSE: The purpose of this in vitro study was to identify the optimal screw tightening protocol for ASC abutments by evaluating the influence of different protocols on reverse tightening values (RTVs). MATERIAL AND METHODS: Fifty implants were randomly assigned to 5 groups (n=10). Implants were mounted and received a cover screw and impression coping to simulate the clinical scenario. Each group was allocated to one of the following protocols: tightened once (1×), tightened twice (2×), tightened twice at a 10-minute interval (2× [10 min]), tightened, countertightened, then tightened again (TCT) and tightened, countertightened, tightened, countertightened, then tightened (TCTCT). A monolithic zirconia central incisor implant crown was fabricated by using computer-aided design and computer-aided manufacturing (CAD-CAM) and cemented onto the ASC abutment. The crown-abutment assemblies were secured onto the implants with the Gold-Tite abutment screw by using their assigned tightening protocols. Each screw was tightened to the recommended value of 20 Ncm with a calibrated digital torque measuring device. Specimens were subjected to 250 000 cycles of cyclic loading simulating 3 months of function with a universal testing machine. RTV was measured for each specimen. RESULTS: The mean RTV for all the groups ranged from 13.5 Ncm to 15.9 Ncm. The highest mean RTV was found with the (1×) protocol. However, the difference was not statistically significant among any of the groups (P>.05). CONCLUSIONS: Multiple retightening and time intervals between tightening events of these ASC abutment screws did not have a significant influence on RTV under simulated function of 3 months. The one time (1×) tightening protocol can be recommended as a suitable method for ASC abutments, thus avoiding unnecessary retightening.

7.
Hum Psychopharmacol ; : e2909, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38995719

RESUMEN

OBJECTIVES: Stimuli that are separated by a short window of space or time, known as spatial and temporal binding windows (SBW/TBWs), may be perceived as separate. Widened TBWs are evidenced in schizophrenia, although it is unclear if the SBW is similarly affected. The current study aimed to assess if dexamphetamine (DEX) may increase SBWs in a multimodal visuo-tactile illusion, potentially validating usefulness as an experimental model for multimodal visuo-tactile hallucinations in schizophrenia, and to examine a possible association between altered binding windows (BWs) and working memory (WM) suggested by previous research. METHODS: A placebo-controlled, double-blinded, and counter-balanced crossover design was employed. Permuted block randomisation was used for drug order. Healthy participants received DEX (0.45 mg/kg, PO, b.i.d.) or placebo (glucose powder) in capsules. The Rubber Hand Illusion (RHI) and Wechsler Adult Intelligence Scale Spatial Span was employed to determine whether DEX would alter SBWs and WM, respectively. Schizotypy was assessed with a variety of psychological scales. RESULTS: Most participants did not experience the RHI even under normal circumstances. Bi-directional and multimodal effects of DEX on individual SBWs and schizotypy were observed, but not on WM. CONCLUSIONS: Bidirectional multimodal effects of DEX on the RHI and SBWs were observed in individuals, although not associated with alterations in WM.

9.
Biomed Mater ; 19(5)2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38917828

RESUMEN

The increasing prevalence of bone replacements and complications associated with bone replacement procedures underscores the need for innovative tissue restoration approaches. Existing synthetic grafts cannot fully replicate bone vascularization and mechanical characteristics. This study introduces a novel strategy utilizing pectin, chitosan, and polyvinyl alcohol to create interpenetrating polymeric network (IPN) scaffolds incorporated with extracellular vesicles (EVs) isolated from human mesenchymal stem cells (hMSCs). We assess the osteointegration and osteoconduction abilities of these modelsin vitrousing hMSCs and MG-63 osteosarcoma cells. Additionally, we confirm exosome properties through Transmission Electron Microscopy (TEM), immunoblotting, and Dynamic Light Scattering (DLS).In vivo, chick allantoic membrane assay investigates vascularization characteristics. The study did not includein vivoanimal experiments. Our results demonstrate that the IPN scaffold is highly porous and interconnected, potentially suitable for bone implants. EVs, approximately 100 nm in size, enhance cell survival, proliferation, alkaline phosphatase activity, and the expression of osteogenic genes. EVs-mediated IPN scaffolds demonstrate promise as precise drug carriers, enabling customized treatments for bone-related conditions and regeneration efforts. Therefore, the EVs-mediated IPN scaffolds demonstrate promise as precise carriers for the transport of drugs, allowing for customized treatments for conditions connected to bone and efforts in regeneration.


Asunto(s)
Regeneración Ósea , Proliferación Celular , Vesículas Extracelulares , Células Madre Mesenquimatosas , Osteogénesis , Andamios del Tejido , Humanos , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/química , Andamios del Tejido/química , Células Madre Mesenquimatosas/citología , Animales , Línea Celular Tumoral , Transducción de Señal , Supervivencia Celular , Ingeniería de Tejidos/métodos , Quitosano/química , Fosfatasa Alcalina/metabolismo , Oseointegración , Polímeros/química , Porosidad
10.
J Neurosurg Pediatr ; 34(2): 121-128, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38701519

RESUMEN

OBJECTIVE: The influence of sleep on baseline and postconcussion neurocognitive performance prior to Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is poorly understood. Since ImPACT is widely used in youth sport to assess neurocognitive performance before and after head injury, it is important to delineate factors that affect testing performance. While some have reported correlations between fewer hours of sleep and lower scores on baseline tests, others have not observed any such associations. Therefore, the authors sought to compare the relationship between sleep and neurocognitive performance on ImPACT at both baseline and postinjury. METHODS: The authors queried a database of 25,815 ImPACT tests taken from 2009 to 2019 by athletes aged 12-22 years. There were 11,564 baseline concussion tests and 7446 postinjury concussion ImPACT tests used in the analysis. Linear regression was used to model the effect of sleep on baseline and postconcussion ImPACT scores adjusting for sex, age, learning disability, attention-deficit/hyperactivity disorder, number of prior concussions, number of games missed, and strenuous exercise before testing. RESULTS: Mean composite scores expectedly were all significantly lower in the post-head injury group compared with the baseline group. In the multivariable analysis, at baseline, hours of sleep significantly affected symptom scores (ß = -1.050, 95% CI -1.187 to -0.9138; p < 0.0001). In the postinjury multivariable analysis, verbal memory (ß = 0.4595, 95% CI 0.2080-0.7110; p = 0.0003), visual memory (ß = 0.3111, 95% CI 0.04463-0.5777; p = 0.0221), impulse control (ß = -0.2321, 95% CI -0.3581 to -0.1062; p = 0.0003), and symptom scores (ß = -0.9168, 95% CI -1.259 to -0.5750; p < 0.0001) were all affected by hours of sleep. CONCLUSIONS: Hours of sleep did not alter neurocognitive metrics at baseline but did have an impact on post-head injury metrics. These findings suggest that individuals may be able to compensate for lack of sleep at baseline but not immediately after concussion. Concussions may reduce cognitive reserve or detract from the brain's resources, making sleep even more important for proper neurocognitive functioning postconcussion. Future work will analyze the effects of sleep on postconcussion test performance.


Asunto(s)
Traumatismos en Atletas , Conmoción Encefálica , Pruebas Neuropsicológicas , Sueño , Humanos , Adolescente , Conmoción Encefálica/complicaciones , Conmoción Encefálica/psicología , Masculino , Femenino , Niño , Adulto Joven , Sueño/fisiología , Traumatismos en Atletas/complicaciones , Factores de Tiempo
11.
Med Biol Eng Comput ; 62(8): 2409-2434, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38609577

RESUMEN

ASTRACT: One of the most common oral diseases affecting millions of people worldwide is periodontitis. Usually, proteins in body fluids are used as biomarkers of diseases. This study focused on hydrogen peroxide, lipopolysaccharide (LPS), and lactic acid as salivary non-protein biomarkers for oxidative stress conditions of periodontitis. Electrochemical analysis of artificial saliva was done using Gamry with increasing hydrogen peroxide, bLPS, and lactic acid concentrations. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were conducted. From EIS data, change in capacitance and CV plot area were calculated for each test condition. Hydrogen peroxide groups had a decrease in CV area and an increase in percentage change in capacitance, lipopolysaccharide groups had a decrease in CV area and a decrease in percentage change in capacitance, and lactic acid groups had an increase of CV area and an increase in percentage change in capacitance with increasing concentrations. These data showed a unique combination of electrochemical properties for the three biomarkers. Scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) employed to observe the change in the electrode surface and elemental composition data present on the sensor surface also showed a unique trend of elemental weight percentages. Machine learning models using hydrogen peroxide, LPS, and lactic acid electrochemical data were applied for the prediction of risk levels of periodontitis. The detection of hydrogen peroxide, LPS, and lactic acid by electrochemical biosensors indicates the potential to use these molecules as electrochemical biomarkers and use the data for ML-driven prediction tool for the periodontitis risk levels.


Asunto(s)
Técnicas Biosensibles , Espectroscopía Dieléctrica , Peróxido de Hidrógeno , Ácido Láctico , Lipopolisacáridos , Estrés Oxidativo , Periodontitis , Saliva , Humanos , Saliva/química , Saliva/metabolismo , Periodontitis/metabolismo , Peróxido de Hidrógeno/análisis , Peróxido de Hidrógeno/metabolismo , Técnicas Biosensibles/métodos , Ácido Láctico/análisis , Ácido Láctico/metabolismo , Espectroscopía Dieléctrica/métodos , Biomarcadores/análisis , Biomarcadores/metabolismo , Aprendizaje Automático
12.
J Prosthet Dent ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38594088

RESUMEN

STATEMENT OF PROBLEM: A predictable protocol for accurately scanning implants in a complete edentulous arch has not been established. PURPOSE: The purpose of this clinical study was to investigate the effect of splinting implant scan bodies intraorally on the accuracy and scan time for digital scans of edentulous arches. MATERIAL AND METHODS: This single center, nonrandomized, clinical trial included a total of 19 arches. Definitive casts with scan bodies were fabricated and scanned with a laboratory scanner as the reference (control) scan. Each participant received 2 intraoral scans, the first with unsplinted scan bodies and the second with resin-splinted scan bodies. The scan time was also recorded for each scan. To compare the accuracy of the scans, the standard tessellation language (STL) files of the 2 scans were superimposed on the control scan, and positional and angular deviations were analyzed by using a 3-dimensional (3D) metrology software program. The Mann-Whitney U test was used to compare the distance and angular deviations between the splinted group and the unsplinted group with the control. The ANOVA test was conducted to examine the effect of the scan technique on trueness (distance deviation and angular deviation) and scan time (α=.05 for all tests). RESULTS: Statistically significant differences were found in the overall 3D positional and angular deviations of the unsplinted and splinted digital scans when compared with the reference scans (P<.05). No statistically significant differences in overall 3-dimensional positional deviations (P=.644) and angular deviations (P=.665) were found between the splinted and unsplinted experimental groups. A faster scan time was found with the splinted group in the maxillary arch. CONCLUSIONS: Conventional complete arch implant impressions were more accurate than digital complete arch implant scans. Splinting implant scan bodies did not significantly affect the trueness of complete arch digital scans, but splinting appeared to reduce the scan time. However, fabricating the splint was not considered in the time measurement.

13.
medRxiv ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38633797

RESUMEN

Background: SARS-CoV-2 vaccines have been shown to be safe and effective against infection and severe COVID-19 disease worldwide. Certain co-morbid conditions cause immune dysfunction and may reduce immune response to vaccination. In contrast, those with co-morbidities may practice infection prevention strategies. Thus, the real-world clinical impact of co-morbidities on SARS-CoV-2 infection in the recent post-vaccination period is not well established. We performed this study to understand the epidemiology of Omicron breakthrough infection and evaluate associations with number of comorbidities in a vaccinated and boosted population. Methods and Findings: We performed a retrospective clinical cohort study utilizing the Northwestern Medicine Enterprise Data Warehouse. Our study population was identified as fully vaccinated adults with at least one booster. The primary risk factor of interest was the number of co-morbidities. Our primary outcome was incidence and time to first positive SARS-CoV-2 molecular test in the Omicron predominant era. We performed multivariable analyses stratified by calendar time using Cox modeling to determine hazard of SARS-CoV-2. In total, 133,191 patients were analyzed. Having 3+ comorbidities was associated with increased hazard for breakthrough (HR=1.2 CI 1.2-1.6). During the second half of the study, having 2 comorbidities (HR= 1.1 95% CI 1.02-1.2) and having 3+ comorbidities (HR 1.7, 95% CI 1.5-1.9) were associated with increased hazard for Omicron breakthrough. Older age was associated with decreased hazard in the first 6 months of follow-up. Interaction terms for calendar time indicated significant changes in hazard for many factors between the first and second halves of the follow-up period. Conclusions: Omicron breakthrough is common with significantly higher risk for our most vulnerable patients with multiple co-morbidities. Age related behavioral factors play an important role in breakthrough infection with the highest incidence among young adults. Our findings reflect real-world differences in immunity and exposure risk behaviors for populations vulnerable to COVID-19.

14.
Saudi Dent J ; 36(1): 123-128, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38375398

RESUMEN

The fabrication of periodontal ligament (PDL) models for in vitro dental studies has seen a wide range of techniques and materials being utilized. This paper introduces a novel dental technique that employs a digital workflow for the fabrication of artificial PDL using three-dimensional printing of flexible resin. This innovative approach offers several advantages, including enhanced accuracy and realism in simulating PDL. The digital workflow facilitates a streamlined fabrication process, ensuring efficiency and precision. By presenting this novel technique, this digital approach contributes to the advancement of in vitro dental research, providing researchers with a reliable and realistic model for studying various dental phenomena.

15.
Hum Psychopharmacol ; 39(3): e2896, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38353526

RESUMEN

OBJECTIVE: Stimuli received beyond a very short timeframe, known as temporal binding windows (TBWs), are perceived as separate events. In previous audio-visual multisensory integration (McGurk effect) studies, widening of TBWs has been observed in people with schizophrenia. The present study aimed to determine if dexamphetamine could increase TBWs in unimodal auditory and unimodal visual illusions that may have some validity as experimental models for auditory and visual hallucinations in psychotic disorders. METHODS: A double-blind, placebo-controlled, counter-balanced crossover design with permuted block randomisation for drug order was followed. Dexamphetamine (0.45 mg/kg, PO, q.d.) was administered to healthy participants. Phantom word illusion (speech illusion) and visual-induced flash illusion/VIFI (visual illusion) tests were measured to determine if TBWs were altered as a function of delay between stimuli presentations. Word emotional content for phantom word illusions was also analysed. RESULTS: Dexamphetamine significantly increased the total number of phantom words/speech illusions (p < 0.01) for pooled 220-1100 ms ISIs in kernel density estimation and the number of positive valence words heard (beta = 2.20, 95% CI [1.86, 2.55], t = 12.46, p < 0.001) with a large effect size (std. beta = 1.05, 95% CI [0.89, 1.22]) relative to placebo without affecting the TBWs. For the VIFI test, kernel density estimation for pooled 0-801 ms ISIs showed a significant difference (p < 0.01) in the data distributions of number of target flash (es) perceived by participants after receiving dexamphetamine as compared with placebo. CONCLUSIONS: Overall, healthy participants who were administered dexamphetamine (0.45 mg/kg, PO, q.d.) experienced increases in auditory and visual illusions in both phantom word illusion and VIFI tests without affecting their TBWs.


Asunto(s)
Estudios Cruzados , Dextroanfetamina , Ilusiones , Percepción Visual , Humanos , Método Doble Ciego , Masculino , Adulto , Femenino , Ilusiones/efectos de los fármacos , Ilusiones/fisiología , Adulto Joven , Dextroanfetamina/farmacología , Dextroanfetamina/administración & dosificación , Percepción Visual/efectos de los fármacos , Percepción Visual/fisiología , Alucinaciones/inducido químicamente , Factores de Tiempo , Estimulación Luminosa/métodos , Estimulantes del Sistema Nervioso Central/farmacología , Estimulantes del Sistema Nervioso Central/administración & dosificación , Estimulación Acústica , Percepción del Habla/efectos de los fármacos , Percepción Auditiva/efectos de los fármacos , Percepción Auditiva/fisiología , Adolescente
16.
Heliyon ; 10(1): e23626, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38192807

RESUMEN

Statement of problem: One of the main challenges facing dental implant success is peri-implantitis. Recent evidence indicates that titanium (Ti) corrosion products and undetected-residual cement are potential risk factors for peri-implantitis. The literature on the impact of various types of dental cement on Ti corrosion is very limited. Purpose: This study aimed to determine the influence of dental cement on Ti corrosion as a function of cement amount and type. Materials and methods: Thirty commercially pure Ti grade 4 discs (19 × 7mm) were polished to mirror-shine (Ra ≈ 40 nm). Samples were divided into 10 groups (n = 3) as a cement type and amount function. The groups were no-cement as control, TempBond NE (TB3mm, TB5mm, and TB8mm), FujiCEM-II (FC3mm, FC5mm, and FC8mm), and Panavia-F-2.0 (PC3mm, PC5mm, and PC8mm). Tafel's method estimated corrosion rate (icorr) and corresponding potential (Ecorr) from potentiodynamic curves. Electrochemical Impedance Spectroscopy (EIS) data was utilized to obtain Nyquist and Bode plots. An equivalent electrical circuit estimated polarization resistance (Rp) and double-layer capacitance (Cdl). Inductively coupled plasma mass spectrometry (ICP-MS) analysis was conducted to analyze the electrolyte solution after corrosion. pH measurements of the electrolyte were recorded before and after corrosion tests. Finally, the corroded surface was characterized by a 3D white-light microscope and scanning electron microscope. Statistical analysis was conducted using either one-way ANOVA followed by Tukey's Post Hoc test or Kruskal-Wallis followed by Dunn's test based on data distribution. Results: Based on cement amount, FC and PC significantly increased icorr in higher amounts (FC8mm-icorr = 8.22 × 10-8A/cm2, PC8mm-icorr = 5.61 × 10-8A/cm2) compared to control (3.35 × 10-8A/cm2). In contrast, TB3mm decreased icorr significantly compared to the control. As a function of cement type, FC increased icorr the most. EIS data agrees with these observations. Finally, corroded surfaces had higher surface roughness (Ra) compared to non-corroded surfaces. Conclusion: The study indicated that cement types FC and PC led to increased Ti-corrosion as a function of a higher amount. Hence, the implant stability could be impacted by the selection, excessive cement, and a potentially increased risk of peri-implantitis.

17.
J Prosthodont ; 33(4): 402-405, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37452670

RESUMEN

Digital replication of an existing cast gold onlay anatomy to a more esthetic material for a new complete denture is challenging. A technique is presented that uses digital technology to fabricate a new maxillary complete denture with monolithic zirconia onlays that duplicate the anatomy of an existing complete denture with cast gold onlays.


Asunto(s)
Diseño de Prótesis Dental , Oro , Flujo de Trabajo , Diseño Asistido por Computadora , Estética Dental , Circonio , Dentadura Completa
18.
19.
Int J Biol Macromol ; 257(Pt 2): 128773, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38096932

RESUMEN

Periodontitis is a chronic inflammation of the periodontium caused by a persistent bacterial infection, resulting in destruction of the supporting structures of teeth. Analysis of microbial composition in saliva can inform periodontal status. Actinobacillus actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), and Streptococcus mutans (Sm) are among reported periodontal pathogens, and were used as model systems in this study. Our atomic force microscopic (AFM) study revealed that these pathogens are biological nanorods with dimensions of 0.6-1.1 µm in length and 500-700 nm in width. Current bacterial detection methods often involve complex preparation steps and require labeled reporting motifs. Employing surface-enhanced Raman spectroscopy (SERS), we revealed cell-type specific Raman signatures of these pathogens for label-free detection. It overcame the complexity associated with spectral overlaps among different bacterial species, relying on high signal-to-noise ratio (SNR) spectra carefully collected from pure species samples. To enable simple, rapid, and multiplexed detection, we harnessed advanced machine learning techniques to establish predictive models based on a large set of raw spectra of each bacterial species and their mixtures. Using these models, given a raw spectrum collected from a bacterial suspension, simultaneous identification of all three species in the test sample was achieved at 95.6 % accuracy. This sensing modality can be applied to multiplex detection of a broader range and a larger set of periodontal pathogens, paving the way for hassle-free detection of oral bacteria in saliva with little to no sample preparation.


Asunto(s)
Periodontitis , Espectrometría Raman , Humanos , Periodontitis/microbiología , Porphyromonas gingivalis , Periodoncio , Saliva
20.
FEBS Lett ; 598(3): 321-330, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38112219

RESUMEN

Sleep during the midday, commonly referred to as siesta, is a common trait of animals that mainly sleep during the night. Work using Drosophila led to the identification of the daywake (dyw) gene, found to have anti-siesta activity. Herein, we show that the DYW protein undergoes signal peptide-dependent secretion, is present in the circulatory system, and accumulates in multiple organs, but, surprisingly, it is not detected in the brain where wake-sleep centers are located. The abundance of DYW in adult flies is regulated by age, sex, temperature, and the splicing efficiency of a nearby thermosensitive intron. We suggest that DYW regulates daytime wake-sleep balance in an indirect, extracerebral manner, via a multi-organ network that interfaces with the circulatory system.


Asunto(s)
Proteínas de Drosophila , Drosophila melanogaster , Animales , Drosophila melanogaster/metabolismo , Ritmo Circadiano/fisiología , Proteínas de Drosophila/genética , Proteínas de Drosophila/metabolismo , Sueño/genética , Drosophila/metabolismo , Lípidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA