Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
4.
Circulation ; 146(22): 1644-1656, 2022 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-36321460

RESUMEN

BACKGROUND: Ablation of ventricular tachycardia (VT) in the setting of structural heart disease often requires extensive substrate elimination that is not always achievable by endocardial radiofrequency ablation. Epicardial ablation is not always feasible. Case reports suggest that venous ethanol ablation (VEA) through a multiballoon, multivein approach can lead to effective substrate ablation, but large data sets are lacking. METHODS: VEA was performed in 44 consecutive patients with ablation-refractory VT (ischemic, n=21; sarcoid, n=3; Chagas, n=2; idiopathic, n=18). Targeted veins were selected by mapping coronary veins on the epicardial aspect of endocardial scar (identified by bipolar voltage <1.5 mV), using venography and signal recording with a 2F octapolar catheter or by guidewire unipolar signals. Epicardial mapping was performed in 15 patients. Vein segments in the epicardial aspect of VT substrates were treated with double-balloon VEA by blocking flow with 1 balloon while injecting ethanol through the lumen of the second balloon, forcing (and restricting) ethanol between balloons. Multiple balloon deployments and multiple veins were used as needed. In 22 patients, late gadolinium enhancement cardiac magnetic resonance imaged the VEA scar and its evolution. RESULTS: Median ethanol delivered was 8.75 (interquartile range, 4.5-13) mL. Injected veins included interventricular vein (6), diagonal (5), septal (12), lateral (16), posterolateral (7), and middle cardiac vein (8), covering the entire range of left ventricular locations. Multiple veins were targeted in 14 patients. Ablated areas were visualized intraprocedurally as increased echogenicity on intracardiac echocardiography and incorporated into 3-dimensional maps. After VEA, vein and epicardial ablation maps showed elimination of abnormal electrograms of the VT substrate. Intracardiac echocardiography demonstrated increased intramural echogenicity at the targeted region of the 3-dimensional maps. At 1 year of follow-up, median of 314 (interquartile range, 198-453) days of follow-up, VT recurrence occurred in 7 patients, for a success of 84.1%. CONCLUSIONS: Multiballoon, multivein intramural ablation by VEA can provide effective substrate ablation in patients with ablation-refractory VT in the setting of structural heart disease over a broad range of left ventricular locations.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Vasos Coronarios , Cicatriz , Etanol/uso terapéutico , Medios de Contraste , Gadolinio , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Ablación por Catéter/efectos adversos
6.
Heart Rhythm ; 19(2): 206-216, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34710561

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.


Asunto(s)
Bloqueo Atrioventricular , COVID-19 , Control de Infecciones , Complicaciones Posoperatorias , Implantación de Prótesis , SARS-CoV-2/aislamiento & purificación , Síndrome del Seno Enfermo , Anciano , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/terapia , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/terapia , Comorbilidad , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Salud Global/estadística & datos numéricos , Humanos , Control de Infecciones/instrumentación , Control de Infecciones/métodos , Control de Infecciones/organización & administración , Masculino , Persona de Mediana Edad , Mortalidad , Evaluación de Resultado en la Atención de Salud , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/mortalidad , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/mortalidad , Factores de Riesgo , Síndrome del Seno Enfermo/epidemiología , Síndrome del Seno Enfermo/terapia , Encuestas y Cuestionarios
9.
J Cardiovasc Electrophysiol ; 32(2): 409-416, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33355965

RESUMEN

INTRODUCTION: Patients with prior cardiac surgery may represent a subgroup of patients with ventricular tachycardia (VT) that may be more difficult to control with catheter ablation. METHODS: We evaluated 1901 patients with ischemic and nonischemic cardiomyopathy who underwent VT ablation at 12 centers. Clinical characteristics and VT radiofrequency ablation procedural outcomes were assessed and compared between those with and without prior cardiac surgery. Kaplan-Meier analysis was used to estimate freedom from recurrent VT and survival. RESULTS: There were 578 subjects (30.4%) with prior cardiac surgery identified in the cohort. Those with prior cardiac surgery were older (66.4 ± 11.0 years vs. 60.5 ± 13.9 years, p < .01), with lower left ventricular ejection fraction (30.2 ± 11.5% vs. 34.8 ± 13.6%, p < .01) and more ischemic heart disease (82.5% vs. 39.3%, p < .01) but less likely to undergo epicardial mapping or ablation (9.0% vs. 38.1%, p<.01) compared to those without prior surgery. When epicardial mapping was performed, a significantly greater proportion required surgical intervention for access (19/52 [36.5%] vs. 14/504 [2.8%]; p < .01). Procedural complications, including epicardial access-related complications, were lower (5.7% vs. 7.0%, p < .01) in patients with versus without prior cardiac surgery. VT-free survival (75.1% vs. 74.1%, p = .805) and survival (86.5% vs. 87.9%, p = .397) were not different between those with and without prior heart surgery, regardless of etiology of cardiomyopathy. VT recurrence was associated with increased mortality in patients with and without prior cardiac surgery. CONCLUSION: Despite different clinical characteristics and fewer epicardial procedures, the safety and efficacy of VT ablation in patients with prior cardiac surgery is similar to others in this cohort. The incremental yield of epicardial mapping in predominant ischemic cardiomyopathy population prior heart surgery may be low but appears safe in experienced centers.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Taquicardia Ventricular , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ablación por Catéter/efectos adversos , Humanos , Pericardio/cirugía , Recurrencia , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda
10.
J Interv Card Electrophysiol ; 62(1): 49-56, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32949304

RESUMEN

PURPOSE: Assess if timing of removal of a percutaneous left ventricular assist device (pLVAD) after ventricular tachycardia (VT) ablation alters patient outcomes. METHODS: Sixty-nine patients underwent pLVAD support. Patients were divided into early (< 24 h, n = 43) and delayed (≥ 24 h, n = 26) removal groups after ablation. Factors for delayed pLVAD removal and predictors of 90-day mortality were analyzed. RESULTS: The delayed removal group had lower LVEF (27.1 ± 9.3% vs. 20.6 ± 5.4%, p = 0.002), greater percentage LVEF < 25% (58.1% vs. 84.6%, p = 0.02), and more VT storm (41.9% vs. 96.2%, p < 0.001). Ventricular fibrillation (VF) was induced in 9/69 (13%), with incidence higher in delayed removal group (27% vs. 5%, p = 0.002). VT storm (OR = 34.72, 95% CI, 4.30-280.33; p = 0.001), LVEF < 25% (OR = 3.95, 95% CI, 1.16-13.48; p = 0.03), and VF induced during ablation (OR = 9.25, 95% CI, 1.71-50.0; p = 0.01) were associated with delayed pLVAD removal in univariate analysis. Delayed pLVAD removal had a significantly higher 90-day mortality rate (2.3% vs 30.2%; p < 0.001). Univariate Cox proportional hazard regression analysis revealed delayed pLVAD removal was a significant predictor of 90-day mortality. CONCLUSIONS: Prolonged pLVAD insertion (≥ 24 h) after VT ablation was associated with VT storm, LVEF < 25%, and VF induced during ablation. Delayed pLVAD removal was a significant predictor of 90-day mortality in patients undergoing VT ablation.


Asunto(s)
Ablación por Catéter , Corazón Auxiliar , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
11.
Card Electrophysiol Clin ; 12(3): 271-280, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32771182

RESUMEN

Percutaneous epicardial access continues to have a growing role within cardiac electrophysiology. The classic approach has typically been with a Tuohy needle via a subxiphoid approach guided by fluoroscopic landmarks and tactile feedback. Recent developments have highlighted the role of the micropuncture needle, electroanatomic mapping, and real-time pressure sensors to reduce complications. Further, different access sites, such as the right atrial appendage, have been described and may offer a novel approach to percutaneous epicardial access. In addition, future directions of percutaneous access may involve direct visualization, near-field impedance monitoring, and real-time virtual imaging.


Asunto(s)
Ablación por Catéter , Procedimientos Endovasculares , Pericardio/cirugía , Técnicas Electrofisiológicas Cardíacas , Cardiopatías/cirugía , Humanos
12.
Front Cardiovasc Med ; 7: 89, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32656246

RESUMEN

Background: For patients with atrial fibrillation who are at high risk for bleeding or who cannot tolerate oral anticoagulation, left atrial appendage (LAA) closure represents an alternative therapy for reducing risk for thromboembolic events. Objectives: To compare the efficacy and safety of the Amplatzer and WatchmanTM LAA closure devices. Methods: A meta-analysis was performed of studies comparing the safety and efficacy outcomes of the two devices. The Newcastle-Ottawa Scale was used to appraise study quality. Results: Six studies encompassing 614 patients were included in the meta-analysis. Overall event rates were low for both devices. No significant differences between the devices were found in safety outcomes (i.e., pericardial effusion, cardiac tamponade, device embolization, air embolism, and vascular complications) or in the rates of all-cause mortality, cardiac death, stroke/transient ischemic attack, or device-related thrombosis. The total bleeding rate was significantly lower in the WatchmanTM group (Log OR = -0.90; 95% CI = -1.76 to -0.04; p = 0.04), yet no significant differences was found when the bleeding rate was categorized into major and minor bleeding. Total peridevice leakage rate and insignificant peridevice leakage rate were significantly higher in the WatchmanTM group (Log OR = 1.32; 95% CI = 0.76 to 1.87; p < 0.01 and Log OR = 1.11; 95% CI = 0.50 to 1.72; p < 0.01, respectively). However, significant peridevice leakages were similar in both the devices. Conclusions: The LAA closure devices had low complication rates and low event rates. Efficacy and safety were similar between the systems, except for a higher percentage of insignificant peridevice leakages in the WatchmanTM group. A randomized controlled trial comparing both devices is underway, which may provide more insight on the safety and efficacy outcomes comparison of the devices.

13.
J Innov Card Rhythm Manag ; 11(2): 3997-4003, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32368372

RESUMEN

A 27-year-old male presented to our institution with recurrent unifocal premature ventricular contraction/nonsustained ventricular tachycardia (VT) with associated cardiomyopathy. The patient had undergone three prior ablation procedures with continued arrhythmia. Mapping led to identification of the VT arising from the basal aspect of the left ventricular anterolateral papillary muscle. Conventional ablation techniques were unsuccessful. We incorporated adjunctive ablation techniques in this case that ultimately led to a successful outcome. The present discussion covers the roles of intracardiac echocardiography, induced apnea, and low-ionic irrigation.

15.
Clin Pract ; 9(1): 1096, 2019 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-30815244

RESUMEN

Direct oral anticoagulants have become increasingly used for atrial fibrillation and venothromboembolic disease. Thus far, there have been a few published cases of pericardial effusion associated with rivaroxban. However, there has been little published regarding the effects of concurrent medications and their effect on the cytochrome enzyme systems involved in rivaroxaban metabolism. We present a case of a 76-year-old female who develops a spontaneous haemopericardium after initiating rivaroxaban. After thorough medical reconciliation, we offer pharmacokinetic mechanisms that may have contributed to the haemopericardium. This case demonstrates the importance of reviewing patients medication lists and utilizing basic pharmacokinetics to prevent adverse events.

16.
J Atr Fibrillation ; 12(3): 2257, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32435338

RESUMEN

Coronary artery spasm during catheter ablation for arrhythmias is a rare but previously reported complication. Timing of presentation, manifestations of vasospasm, and purported mechanisms vary somewhat in the prior literature. We present a case of chest pain, inferior lead ST elevation, and complete AV block with angiographically confirmed right coronary artery (RCA) vasospasm that occurred immediately after catheter ablation for atrial fibrillation.

17.
Circ Arrhythm Electrophysiol ; 11(12): e006730, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30562104

RESUMEN

BACKGROUND: Several distinct risk factors for arrhythmia recurrence and mortality following ventricular tachycardia (VT) ablation have been described. The effect of concurrent risk factors has not been assessed so far; thus, it is not yet possible to estimate these risks for a patient with several comorbidities. The aim of the study was to identify specific risk groups for mortality and VT recurrence using the Survival Tree (ST) analysis method. METHODS: In 1251 patients 16 demographic, clinical and procedure-related variables were evaluated as potential prognostic factors using ST analysis using a recursive partitioning algorithm that searches for relationships among variables. Survival time and time to VT recurrence in groups derived from ST analysis were compared by a log-rank test. A random forest analysis was then run to extract a variable importance index and internally validate the ST models. RESULTS: Left ventricular ejection fraction, implantable cardioverter defibrillator/cardiac resynchronization device, previous ablation were, in hierarchical order, identified by ST analysis as best predictors of VT recurrence, while left ventricular ejection fraction, previous ablation, Electrical storm were identified as best predictors of mortality. Three groups with significantly different survival rates were identified. Among the high-risk group, 65.0% patients were survived and 52.1% patients were free from VT recurrence; within the medium- and low-risk groups, 84.0% and 97.2% patients survived, 72.4% and 88.4% were free from VT recurrence, respectively. CONCLUSIONS: Our study is the first to derive and validate a decisional model that provides estimates of VT recurrence and mortality with an effective classification tree. Preprocedure risk stratification could help optimize periprocedural and postprocedural care.


Asunto(s)
Ablación por Catéter/mortalidad , Electrocardiografía/métodos , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/cirugía , Factores de Edad , Anciano , Anciano de 80 o más Años , Ablación por Catéter/métodos , Estudios de Cohortes , Bases de Datos Factuales , Árboles de Decisión , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Volumen Sistólico/fisiología , Análisis de Supervivencia , Taquicardia Ventricular/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento
18.
Front Cardiovasc Med ; 5: 131, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30460239

RESUMEN

Importance: Ischemic strokes pose a significant health burden. However, the etiology of between 20 and 40% of these events remains unknown. Left atrial appendage morphology may influence the occurrence of thromboembolic events. Design: A retrospective cross-sectional study was conducted to investigate the role of LAA morphology in patients with atrial fibrillation (AF) and cardioembolic-associated stroke and patients with cryptogenic stroke without atrial fibrillation. LAA morphology is classified into two groups: (1) simple (chicken-wing) vs. (2) complex (non-chicken wing) based on transesophageal echocardiography (TEE) findings. In addition to the LAA morphology, left atrial parameters, including orifice diameter, depth, emptying velocity, and filling velocity, were collected for both groups. Mathematical, computational models were constructed to investigate flow velocities in chicken-wing and non-chicken wing morphological patterns to assess LAA function further. Findings: TEE values for volume, size, emptying, and filling velocities were similar between simple and complex LAA morphology groups. Patients with cryptogenic stroke without coexisting AF were noted to have significantly higher rates of complex LAA morphology. Chicken-wing LAA morphology was associated with four-fold higher flow rate (kg/s) in computational simulations. Conclusions: Complex LAA morphology may be an independent contributing factor for cryptogenic strokes. Further studies are warranted to investigate the mechanism involved in LAA morphology and thromboembolic events.

19.
JACC Clin Electrophysiol ; 4(9): 1141-1150, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30236386

RESUMEN

OBJECTIVES: This study sought to characterize ventricular tachycardia (VT) ablation outcomes across nonischemic cardiomyopathy (NICM) etiologies and adjust these outcomes by patient-related comorbidities that could explain differences in arrhythmia recurrence rates. BACKGROUND: Outcomes of catheter ablation of VT in patients with NICM could be related to etiology of NICM. METHODS: Data from 2,075 patients with structural heart disease referred for catheter ablation of VT from 12 international centers was retrospectively analyzed. Patient characteristics and outcomes were noted for the 6 most common NICM etiologies. Multivariable Cox proportional hazards modeling was used to adjust for potential confounders. RESULTS: Of 780 NICM patients (57 ± 14 years of age, 18% women, left ventricular ejection fraction 37 ± 13%), underlying prevalence was 66% for dilated idiopathic cardiomyopathy (DICM), 13% for arrhythmogenic right ventricular cardiomyopathy (ARVC), 6% for valvular cardiomyopathy, 6% for myocarditis, 4% for hypertrophic cardiomyopathy, and 3% for sarcoidosis. One-year freedom from VT was 69%, and freedom from VT, heart transplantation, and death was 62%. On unadjusted competing risk analysis, VT ablation in ARVC demonstrated superior VT-free survival (82%) versus DICM (p ≤ 0.01). Valvular cardiomyopathy had the poorest unadjusted VT-free survival, at 47% (p < 0.01). After adjusting for comorbidities, including age, heart failure severity, ejection fraction, prior ablation, and antiarrhythmic medication use, myocarditis, ARVC, and DICM demonstrated similar outcomes, whereas hypertrophic cardiomyopathy, valvular cardiomyopathy, and sarcoidosis had the highest risk of VT recurrence. CONCLUSIONS: Catheter ablation of VT in NICM is effective. Etiology of NICM is a significant predictor of outcomes, with ARVC, myocarditis, and DICM having similar but superior outcomes to hypertrophic cardiomyopathy, valvular cardiomyopathy, and sarcoidosis, after adjusting for potential covariates.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Taquicardia Ventricular , Adulto , Anciano , Cardiomiopatías/complicaciones , Cardiomiopatías/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...