Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ann Thorac Surg ; 69(6): 1764-8, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10892921

RESUMEN

BACKGROUND: Tissue glues are used in cardiothoracic surgery as an adjunct to operative procedures where tissues are frail, as in aortic dissection, or where added hemostasis is required. This study was undertaken to review the use of tissue glue in our institution over a 5.5-year period. The aim of the study was to identify any potentially glue-related complications. METHODS: A review of tissue glue use for the period from January 1993 to September 1998 was performed and pre-, intra-, and postoperative parameters were collected. After some unusual surgical findings, of special interest was a range of pathology found at late reoperation. RESULTS: A total of 67 cases of tissue glue use were identified, with the majority of operations for type A dissection (76%). There were two intraoperative deaths. Twenty-seven of 65 patients (41%) required 29 further open chest operations; of these, 17 were for acute problems of bleeding or tamponade. Twelve patients (18%) underwent late reoperations months to years later. Nine of these patients, concentrated in two operative groups (7 patients with aortic valve resuspension and 2 patients who had undergone "switch" operations for transposition of great vessels), displayed complications related to the application of gelatin-resorcinol-formaldehyde (GRF) tissue glue. CONCLUSIONS: Indications for tissue glues in cardiothoracic surgery must be carefully considered. We have reviewed our use of some tissue glues in acute type A aortic dissections and in pediatric cardiac patients and have discontinued the use of GRF glues because of unsatisfactory long-term complications.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Hemostasis Quirúrgica , Complicaciones Posoperatorias/etiología , Adhesivos Tisulares/efectos adversos , Disección Aórtica/patología , Aorta Torácica/patología , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/patología , Combinación de Medicamentos , Femenino , Formaldehído/efectos adversos , Formaldehído/uso terapéutico , Gelatina/efectos adversos , Gelatina/uso terapéutico , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/patología , Complicaciones Posoperatorias/cirugía , Recurrencia , Reoperación , Resorcinoles/efectos adversos , Resorcinoles/uso terapéutico , Estudios Retrospectivos , Adhesivos Tisulares/uso terapéutico
2.
Ann Thorac Surg ; 60(2 Suppl): S65-70, 1995 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7646213

RESUMEN

Aortic valve replacement using an allograft aortic valve has been performed on 804 patients. From December 1969 to May 1975, 124 patients received a nonviable allograft valve sterilized by incubation with low-dose antibiotics and stored for weeks by refrigeration at 4 degrees C (series 1). From June 1975 to January 1994, 680 patients received viable allograft valves, now cryopreserved early within 2 hours of collection from transplant recipient donors, 6 hours for multiorgan donor valves and 23 hours (mean) for autopsy valves from donor death. The 30-day mortality was 8.9% +/- 5% (95% confidence limits) for series I and 2.8% +/- 1% (95% confidence limits) for series II. Actuarial patient survival including hospital mortality at 15 years was 56% +/- 5% for series I and 62% +/- 5% for series II. The probability of a thromboembolic event was low, freedom at 15 years being 95% +/- 1% for patients receiving allografts with or without associated coronary bypass procedures and 81% +/- 5% for patients having allografts with other associated procedures (eg, mitral valve operations). Actuarial freedom from endocarditis was similar for the two series, 91% +/- 3% (series I) and 94% +/- 2% (series II) at 15 years. The freedom from valve incompetence, from reoperation for all causes, and from structural deterioration demonstrated clearly the inferiority of the 4 degrees C stored allograft valves. For structural deterioration as identified clinically, at reoperation and at death, freedom from this event at 15 years was 45% +/- 6% for series I and 80% +/- 5% for series II (p value for the difference is 0).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Válvula Aórtica/trasplante , Análisis Actuarial , Insuficiencia de la Válvula Aórtica/etiología , Criopreservación , Endocarditis/etiología , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Tasa de Supervivencia , Tromboembolia/etiología , Conservación de Tejido , Trasplante Homólogo/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...