Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
EuroIntervention ; 20(10): e669-e680, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38776143

RESUMEN

BACKGROUND: Compared with thin-strut durable-polymer drug-eluting stents (DP-DES), ultrathin-strut biodegradable-polymer sirolimus-eluting stents (BP-SES) improve stent-related clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). Reduced stent strut thickness is hypothesised to underlie these benefits, but this conjecture remains unproven. AIMS: We aimed to assess the impact of strut thickness on stent healing and clinical outcomes between ultrathin-strut and thin-strut BP-SES. METHODS: First, we performed a preclinical study of 8 rabbits implanted with non-overlapping thin-strut (diameter/thickness 3.5 mm/80 µm) and ultrathin-strut (diameter/thickness 3.0 mm/60 µm) BP-SES in the infrarenal aorta. On day 7, the rabbits underwent intravascular near-infrared fluorescence optical coherence tomography (NIRF-OCT) molecular-structural imaging of fibrin deposition and stent tissue coverage, followed by histopathological analysis. Second, we conducted an individual data pooled analysis of patients enrolled in the BIOSCIENCE and BIOSTEMI randomised PCI trials treated with ultrathin-strut (n=282) or thin-strut (n=222) BP-SES. The primary endpoint was target lesion failure (TLF) at 1-year follow-up, with a landmark analysis at 30 days. RESULTS: NIRF-OCT image analyses revealed that ultrathin-strut and thin-strut BP-SES exhibited similar stent fibrin deposition (p=0.49) and percentage of uncovered stent struts (p=0.63). Histopathological assessments corroÂborated these findings. In 504 pooled randomised trial patients, TLF rates were similar for those treated with ultrathin-strut or thin-strut BP-SES at 30-day (2.5% vs 1.8%; p=0.62) and 1-year follow-up (4.3% vs 4.7%; p=0.88). CONCLUSIONS: Ultrathin-strut and thin-strut BP-SES demonstrate similar early arterial healing profiles and 30-day and 1-year clinical outcomes.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Sirolimus , Tomografía de Coherencia Óptica , Animales , Conejos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Humanos , Sirolimus/uso terapéutico , Sirolimus/administración & dosificación , Sirolimus/farmacología , Resultado del Tratamiento , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Masculino , Implantes Absorbibles , Femenino , Cicatrización de Heridas
2.
bioRxiv ; 2023 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-37547009

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) is a major challenge in cardiovascular medicine, accounting for approximately 50% of all cases of heart failure. Due to the lack of effective therapies for this condition, the mortality associated with HFpEF remains higher than that of most cancers. Despite the ongoing efforts, no medical device has yet received FDA approval. This is largely due to the lack of an in vivo model of the HFpEF hemodynamics, resulting in the inability to evaluate device effectiveness in vivo prior to clinical trials. Here, we describe the development of a highly tunable porcine model of HFpEF hemodynamics using implantable soft robotic sleeves, where controlled actuation of a left ventricular and an aortic sleeve can recapitulate changes in ventricular compliance and afterload associated with a broad spectrum of HFpEF hemodynamic phenotypes. We demonstrate the feasibility of the proposed model in preclinical testing by evaluating the hemodynamic response of the model post-implantation of an interatrial shunt device, which was found to be consistent with findings from in silico studies and clinical trials. This work addresses several of the limitations associated with previous models of HFpEF, such as their limited hemodynamic fidelity, elevated costs, lengthy development time, and low throughput. By showcasing exceptional versatility and tunability, the proposed platform has the potential to revolutionize the current approach for HFpEF device development and selection, with the goal of improving the quality of life for the 32 million people affected by HFpEF worldwide.

3.
Metabolism ; 145: 155608, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37268056

RESUMEN

BACKGROUND: Myocardial infarction (MI) is a major risk factor for the development of heart failure with reduce ejection fraction (HFrEF). While previous studies have focused on HFrEF, the cardiovascular effects of ketone bodies in acute MI are unclear. We examined the effects of oral ketone supplementation as a potential treatment strategy in a swine acute MI model. METHODS: Farm pigs underwent percutaneous balloon occlusion of the LAD for 80 min followed by 72 h reperfusion period. Oral ketone ester or vehicle was administered during reperfusion and continued during the follow-up period. RESULTS: Oral KE supplementation induced ketonemia 2-3 mmol/l within 30 min after ingestion. KE increased ketone (ßHB) extraction in healthy hearts without affecting glucose and fatty acid (FA) consumption. During reperfusion, the MI hearts consumed less FA with no change in glucose consumption, whereas hearts from MI-KE-fed animals consumed more ßHB and FA, as well as improved myocardial ATP production. A significant elevation of infarct T2 values indicative of inflammation was found only in untreated MI group compared to sham. Concordantly, cardiac expression of inflammatory markers, oxidative stress, and apoptosis were reduced by KE. RNA-seq analysis identified differentially expressed genes related to mitochondrial energy metabolism and inflammation. CONCLUSIONS: Oral KE supplementation induced ketosis and enhanced myocardial ßHB extraction in both healthy and infarcted hearts. Acute oral supplementation with KE favorably altered cardiac substrate uptake and utilization, improved cardiac ATP levels, and reduced cardiac inflammation following MI.


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Porcinos , Animales , Cetonas/farmacología , Volumen Sistólico , Modelos Animales de Enfermedad , Infarto del Miocardio/tratamiento farmacológico , Infarto del Miocardio/metabolismo , Adenosina Trifosfato , Glucosa/farmacología , Suplementos Dietéticos
4.
Nat Biomed Eng ; 6(10): 1134-1147, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36163494

RESUMEN

Preclinical models of aortic stenosis can induce left ventricular pressure overload and coarsely control the severity of aortic constriction. However, they do not recapitulate the haemodynamics and flow patterns associated with the disease. Here we report the development of a customizable soft robotic aortic sleeve that can mimic the haemodynamics and biomechanics of aortic stenosis. By allowing for the adjustment of actuation patterns and blood-flow dynamics, the robotic sleeve recapitulates clinically relevant haemodynamics in a porcine model of aortic stenosis, as we show via in vivo echocardiography and catheterization studies, and a combination of in vitro and computational analyses. Using in vivo and in vitro magnetic resonance imaging, we also quantified the four-dimensional blood-flow velocity profiles associated with the disease and with bicommissural and unicommissural defects re-created by the robotic sleeve. The design of the sleeve, which can be adjusted on the basis of computed tomography data, allows for the design of patient-specific devices that may guide clinical decisions and improve the management and treatment of patients with aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Robótica , Porcinos , Animales , Fenómenos Biomecánicos , Presión Ventricular , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Hemodinámica
5.
Stroke ; 53(2): 595-604, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34965737

RESUMEN

BACKGROUND AND PURPOSE: High-risk atherosclerosis is an underlying cause of cardiovascular events, yet identifying the specific patient population at immediate risk is still challenging. Here, we used a rabbit model of atherosclerotic plaque rupture and human carotid endarterectomy specimens to describe the potential of molecular fibrin imaging as a tool to identify thrombotic plaques. METHODS: Atherosclerotic plaques in rabbits were induced using a high-cholesterol diet and aortic balloon injury (N=13). Pharmacological triggering was used in a group of rabbits (n=9) to induce plaque disruption. Animals were grouped into thrombotic and nonthrombotic plaque groups based on gross pathology (gold standard). All animals were injected with a novel fibrin-specific probe 68Ga-CM246 followed by positron emission tomography (PET)/magnetic resonance imaging 90 minutes later. 68Ga-CM246 was quantified on the PET images using tissue-to-background (back muscle) ratios and standardized uptake value. RESULTS: Both tissue-to-background (back muscle) ratios and standardized uptake value were significantly higher in the thrombotic versus nonthrombotic group (P<0.05). Ex vivo PET and autoradiography of the abdominal aorta correlated positively with in vivo PET measurements. Plaque disruption identified by 68Ga-CM246 PET agreed with gross pathology assessment (85%). In ex vivo surgical specimens obtained from patients undergoing elective carotid endarterectomy (N=12), 68Ga-CM246 showed significantly higher binding to carotid plaques compared to a D-cysteine nonbinding control probe. CONCLUSIONS: We demonstrated that molecular fibrin PET imaging using 68Ga-CM246 could be a useful tool to diagnose experimental and clinical atherothrombosis. Based on our initial results using human carotid plaque specimens, in vivo molecular imaging studies are warranted to test 68Ga-CM246 PET as a tool to stratify risk in atherosclerotic patients.


Asunto(s)
Fibrina , Trombosis Intracraneal/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Animales , Aorta Abdominal/diagnóstico por imagen , Músculos de la Espalda/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Femenino , Radioisótopos de Galio , Humanos , Procesamiento de Imagen Asistido por Computador , Trombosis Intracraneal/etiología , Imagen por Resonancia Magnética , Masculino , Placa Aterosclerótica/complicaciones , Conejos
6.
J Am Heart Assoc ; 10(20): e020834, 2021 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-34632804

RESUMEN

BACKGROUND New pharmacological approaches are needed to prevent stent restenosis. This study tested the hypothesis that pemafibrate, a novel clinical selective PPARα (peroxisome proliferator-activated receptor α) agonist, suppresses coronary stent-induced arterial inflammation and neointimal hyperplasia. METHODS AND RESULTS Yorkshire pigs randomly received either oral pemafibrate (30 mg/day; n=6) or control vehicle (n=7) for 7 days, followed by coronary arterial implantation of 3.5 × 12 mm bare metal stents (2-4 per animal; 44 stents total). On day 7, intracoronary molecular-structural near-infrared fluorescence and optical coherence tomography imaging was performed to assess the arterial inflammatory response, demonstrating that pemafibrate reduced stent-induced inflammatory protease activity (near-infrared fluorescence target-to-background ratio: pemafibrate, median [25th-75th percentile]: 2.8 [2.5-3.3] versus control, 4.1 [3.3-4.3], P=0.02). At day 28, animals underwent repeat near-infrared fluorescence-optical coherence tomography imaging and were euthanized, and coronary stent tissue molecular and histological analyses. Day 28 optical coherence tomography imaging showed that pemafibrate significantly reduced stent neointima volume (pemafibrate, 43.1 [33.7-54.1] mm3 versus control, 54.2 [41.2-81.1] mm3; P=0.03). In addition, pemafibrate suppressed day 28 stent-induced cellular inflammation and neointima expression of the inflammatory mediators TNF-α (tumor necrosis factor-α) and MMP-9 (matrix metalloproteinase 9) and enhanced the smooth muscle differentiation markers calponin and smoothelin. In vitro assays indicated that the STAT3 (signal transducer and activator of transcription 3)-myocardin axes mediated the inhibitory effects of pemafibrate on smooth muscle cell proliferation. CONCLUSIONS Pemafibrate reduces preclinical coronary stent inflammation and neointimal hyperplasia following bare metal stent deployment. These results motivate further trials evaluating pemafibrate as a new strategy to prevent clinical stent restenosis.


Asunto(s)
Enfermedad de la Arteria Coronaria , PPAR alfa , Animales , Benzoxazoles , Butiratos , Constricción Patológica , Hiperplasia , Inflamación/prevención & control , Neointima , Stents , Porcinos
8.
J Biophotonics ; 14(10): e202100048, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34164943

RESUMEN

Coronary artery disease (CAD) remains a leading cause of mortality and warrants new imaging approaches to better guide clinical care. We report on a miniaturized, hybrid intravascular catheter and imaging system for comprehensive coronary artery imaging in vivo. Our catheter exhibits a total diameter of 1.0 mm (3.0 French), equivalent to standalone clinical intravascular ultrasound (IVUS) catheters but enables simultaneous near-infrared fluorescence (NIRF) and IVUS molecular-structural imaging. We demonstrate NIRF-IVUS imaging in vitro in coronary stents using NIR fluorophores, and compare NIRF signal strengths for prism and ball lens sensor designs in both low and high scattering media. Next, in vivo intravascular imaging in pig coronary arteries demonstrates simultaneous, co-registered molecular-structural imaging of experimental CAD inflammation on IVUS and distance-corrected NIRF images. The obtained results suggest substantial potential for the NIRF-IVUS catheter to advance standalone IVUS, and enable comprehensive phenotyping of vascular disease to better assess and treat patients with CAD.


Asunto(s)
Enfermedad de la Arteria Coronaria , Espectroscopía Infrarroja Corta , Animales , Catéteres , Vasos Coronarios/diagnóstico por imagen , Humanos , Porcinos , Ultrasonografía
9.
ACS Sens ; 6(6): 2225-2232, 2021 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-34056903

RESUMEN

Platelets play a prominent role in multiple diseases, in particular arterial and venous thrombosis and also in atherosclerosis and cancer. To advance the in vivo study of the biological activity of this cell type from a basic experimental focus to a clinical focus, new translatable platelet-specific molecular imaging agents are required. Herein, we report the development of a near-infrared fluorescence probe based upon tirofiban, a clinically approved small-molecule glycoprotein IIb/IIIa inhibitor (GPIIb/IIIa). Through in vitro experiments with human platelets and in vivo ones in a murine model of deep-vein thrombosis, we demonstrate the avidity of the generated probe for activated platelets, with the added benefit of a short blood half-life, thereby enabling rapid in vivo visualization within the vasculature.


Asunto(s)
Plaquetas , Inhibidores de Agregación Plaquetaria , Animales , Humanos , Ratones , Imagen Óptica , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria , Tirofibán
10.
JACC Basic Transl Sci ; 5(7): 685-695, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32760856

RESUMEN

Paclitaxel drug-coated balloons (DCBs) reduce restenosis, but their overall safety has recently raised concerns. This study hypothesized that DCBs could lessen inflammation and reduce plaque progression. Using 25 rabbits with cholesterol feeding- and balloon injury-induced lesions, DCB-percutaneous transluminal angioplasty (PTA), plain PTA, or sham-PTA (balloon insertion without inflation) was investigated using serial intravascular near-infrared fluorescence-optical coherence tomography and serial intravascular ultrasound. In these experiments, DCB-PTA reduced inflammation and plaque burden in nonobstructive lesions compared with PTA or sham-PTA. These findings indicated the potential for DCBs to serve safely as regional anti-atherosclerosis therapy.

11.
Light Sci Appl ; 8: 104, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31798843

RESUMEN

Cross-sectional visualisation of the cellular and subcellular structures of human atherosclerosis in vivo is significant, as this disease is fundamentally caused by abnormal processes that occur at this scale in a depth-dependent manner. However, due to the inherent resolution-depth of focus tradeoff of conventional focusing optics, today's highest-resolution intravascular imaging technique, namely, optical coherence tomography (OCT), is unable to provide cross-sectional images at this resolution through a coronary catheter. Here, we introduce an intravascular imaging system and catheter based on few-mode interferometry, which overcomes the depth of focus limitation of conventional high-numerical-aperture objectives and enables three-dimensional cellular-resolution intravascular imaging in vivo by a submillimetre diameter, flexible catheter. Images of diseased cadaver human coronary arteries and living rabbit arteries were acquired with this device, showing clearly resolved cellular and subcellular structures within the artery wall, such as individual crystals, smooth muscle cells, and inflammatory cells. The capability of this technology to enable cellular-resolution, cross-sectional intravascular imaging will make it possible to study and diagnose human coronary disease with much greater precision in the future.

12.
Circ Cardiovasc Imaging ; 10(5)2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28487316

RESUMEN

BACKGROUND: The role of local alterations in endothelial functional integrity in atherosclerosis remains incompletely understood. This study used nanoparticle-enhanced optical molecular imaging to probe in vivo mechanisms involving impaired endothelial barrier function in experimental atherothrombosis. METHODS AND RESULTS: Atherosclerosis was induced in rabbits (n=31) using aortic balloon injury and high-cholesterol diet. Rabbits received ultrasmall superparamagnetic iron oxide nanoparticles (CLIO) derivatized with a near-infrared fluorophore (CyAm7) 24 hours before near-infrared fluorescence imaging. Rabbits were then either euthanized (n=9) or underwent a pharmacological triggering protocol to induce thrombosis (n=22). CLIO-CyAm7 nanoparticles accumulated in areas of atheroma (P<0.05 versus reference areas). On near-infrared fluorescence microscopy, CLIO-CyAm7 primarily deposited in the superficial intima within plaque macrophages, endothelial cells, and smooth muscle cells. Nanoparticle-positive areas further exhibited impaired endothelial barrier function as illuminated by Evans blue leakage. Deeper nanoparticle deposition occurred in areas of plaque neovascularization. In rabbits subject to pharmacological triggering, plaques that thrombosed exhibited significantly higher CLIO-CyAm7 accumulation compared with nonthrombosed plaques (P<0.05). In thrombosed plaques, nanoparticles accumulated preferentially at the plaque-thrombus interface. Intravascular 2-dimensional near-infrared fluorescence imaging detected nanoparticles in human coronary artery-sized atheroma in vivo (P<0.05 versus reference segments). CONCLUSIONS: Plaques that exhibit impaired in vivo endothelial permeability in cell-rich areas are susceptible to subsequent thrombosis. Molecular imaging of nanoparticle deposition may help to identify biologically high-risk atheroma.


Asunto(s)
Endotelio Vascular/diagnóstico por imagen , Imagen Óptica/métodos , Placa Aterosclerótica/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Endotelio Vascular/fisiopatología , Imagen Molecular/métodos , Nanopartículas , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/fisiopatología , Conejos , Trombosis de la Vena/complicaciones , Trombosis de la Vena/fisiopatología
13.
Eur Heart J Cardiovasc Imaging ; 18(5): 510-518, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28039209

RESUMEN

AIMS: Inflammation drives atherosclerosis complications and is a promising therapeutic target for plaque stabilization. At present, it is unknown whether local stenting approaches can stabilize plaque inflammation in vivo. Here, we investigate whether everolimus-eluting stents (EES) can locally suppress plaque inflammatory protease activity in vivo using intravascular near-infrared fluorescence (NIRF) molecular imaging. METHODS AND RESULTS: Balloon-injured, hyperlipidaemic rabbits with atherosclerosis received non-overlapping EES and bare metal stents (BMS) placement into the infrarenal aorta (n = 7 EES, n = 7 BMS, 3.5 mm diameter x 12 mm length). Four weeks later, rabbits received an injection of the cysteine protease-activatable NIRF imaging agent Prosense VM110. Twenty-four hours later, co-registered intravascular 2D NIRF, X-ray angiography and intravascular ultrasound imaging were performed. In vivo EES-stented plaques contained substantially reduced NIRF inflammatory protease activity compared with untreated plaques and BMS-stented plaques (P = 0.006). Ex vivo macroscopic NIRF imaging of plaque protease activity corroborated the in vivo results (P = 0.003). Histopathology analyses revealed that EES-treated plaques showed reduced neointimal and medial arterial macrophage and cathepsin B expression compared with unstented and BMS-treated plaques. CONCLUSIONS: EES-stenting stabilizes plaque inflammation as assessed by translational intravascular NIRF molecular imaging in vivo. These data further support that EES may provide a local approach for stabilizing inflamed plaques.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Everolimus/farmacología , Inflamación/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Espectroscopía Infrarroja Corta/métodos , Animales , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/terapia , Modelos Animales de Enfermedad , Inflamación/patología , Masculino , Imagen Molecular/métodos , Placa Aterosclerótica/patología , Conejos , Distribución Aleatoria , Sensibilidad y Especificidad , Espectrometría de Fluorescencia/métodos
14.
Eur Heart J Cardiovasc Imaging ; 18(11): 1253-1261, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28031233

RESUMEN

AIMS: (i) to evaluate a novel hybrid near-infrared fluorescence-intravascular ultrasound (NIRF-IVUS) system in coronary and peripheral swine arteries in vivo; (ii) to assess simultaneous quantitative biological and morphological aspects of arterial disease. METHODS AND RESULTS: Two 9F/15MHz peripheral and 4.5F/40MHz coronary near-infrared fluorescence (NIRF)-IVUS catheters were engineered to enable accurate co-registrtation of biological and morphological readings simultaneously in vivo. A correction algorithm utilizing IVUS information was developed to account for the distance-related fluorescence attenuation due to through-blood imaging. Corrected NIRF (cNIRF)-IVUS was applied for in vivo imaging of angioplasty-induced vascular injury in swine peripheral arteries and experimental fibrin deposition on coronary artery stents, and of atheroma in a rabbit aorta, revealing feasibility to intravascularly assay plaque structure and inflammation. The addition of ICG-enhanced NIRF assessment improved the detection of angioplasty-induced endothelial damage compared to standalone IVUS. In addition, NIRF detection of coronary stent fibrin by in vivo cNIRF-IVUS imaging illuminated stent pathobiology that was concealed on standalone IVUS. Fluorescence reflectance imaging and microscopy of resected tissues corroborated the in vivo findings. CONCLUSIONS: Integrated cNIRF-IVUS enables simultaneous co-registered through-blood imaging of disease related morphological and biological alterations in coronary and peripheral arteries in vivo. Clinical translation of cNIRF-IVUS may significantly enhance knowledge of arterial pathobiology, leading to improvements in clinical diagnosis and prognosis, and helps to guide the development of new therapeutic approaches for arterial diseases.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Espectrometría de Fluorescencia/métodos , Espectroscopía Infrarroja Corta/métodos , Ultrasonografía Intervencional/métodos , Algoritmos , Animales , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/patología , Enfermedades Vasculares Periféricas/patología , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/patología , Conejos , Stents , Porcinos
15.
Eur Heart J ; 38(6): 447-455, 2017 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-26685129

RESUMEN

AIMS: Fibrin deposition and absent endothelium characterize unhealed stents that are at heightened risk of stent thrombosis. Optical coherence tomography (OCT) is increasingly used for assessing stent tissue coverage as a measure of healed stents, but cannot precisely identify whether overlying tissue represents physiological neointima. Here we assessed and compared fibrin deposition and persistence on bare metal stent (BMS) and drug-eluting stent (DES) using near-infrared fluorescence (NIRF) molecular imaging in vivo, in combination with simultaneous OCT stent coverage. METHODS AND RESULTS: Rabbits underwent implantation of one BMS and one DES without overlap in the infrarenal aorta (N = 20 3.5 × 12 mm). At Days 7 and/or 28, intravascular NIRF-OCT was performed following the injection of fibrin-targeted NIRF molecular imaging agent FTP11-CyAm7. Intravascular NIRF-OCT enabled high-resolution imaging of fibrin overlying stent struts in vivo, as validated by histopathology. Compared with BMS, DES showed greater fibrin deposition and fibrin persistence at Days 7 and 28 (P < 0.01 vs. BMS). Notably, for edge stent struts identified as covered by OCT on Day 7, 92.8 ± 9.5% of DES and 55.8 ± 23.6% of BMS struts were NIRF fibrin positive (P < 0.001). At Day 28, 18.6 ± 10.6% (DES) and 5.1 ± 8.7% (BMS) of OCT-covered struts remained fibrin positive (P < 0.001). CONCLUSION: Intravascular NIRF fibrin molecular imaging improves the detection of unhealed stents, using clinically translatable technology that complements OCT. A sizeable percentage of struts deemed covered by OCT are actually covered by fibrin, particularly in DES, and therefore such stents might remain prothrombotic. These findings have implications for the specificity of standalone clinical OCT assessments of stent healing.

16.
Sci Rep ; 6: 21785, 2016 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-26911995

RESUMEN

We aimed to develop a quantitative antibody-based near infrared fluorescence (NIRF) approach for the imaging of oxidized LDL in atherosclerosis. LO1, a well- characterized monoclonal autoantibody that reacts with malondialdehyde-conjugated LDL, was labeled with a NIRF dye to yield LO1-750. LO1-750 specifically identified necrotic core in ex vivo human coronary lesions. Injection of LO1-750 into high fat (HF) fed atherosclerotic Ldlr(-/-) mice led to specific focal localization within the aortic arch and its branches, as detected by fluorescence molecular tomography (FMT) combined with micro-computed tomography (CT). Ex vivo confocal microscopy confirmed LO1-750 subendothelial localization of LO1-750 at sites of atherosclerosis, in the vicinity of macrophages. When compared with a NIRF reporter of MMP activity (MMPSense-645-FAST), both probes produced statistically significant increases in NIRF signal in the Ldlr(-/-) model in relation to duration of HF diet. Upon withdrawing the HF diet, the reduction in oxLDL accumulation, as demonstrated with LO1-750, was less marked than the effect seen on MMP activity. In the rabbit, in vivo injected LO1-750 localization was successfully imaged ex vivo in aortic lesions with a customised intra-arterial NIRF detection catheter. A partially humanized chimeric LO1-Fab-Cys localized similarly to the parent antibody in murine atheroma showing promise for future translation.


Asunto(s)
Aterosclerosis/patología , Autoanticuerpos/química , Colorantes Fluorescentes/química , Lipoproteínas LDL/química , Albendazol , Animales , Antígenos/inmunología , Aorta Torácica/diagnóstico por imagen , Aterosclerosis/diagnóstico por imagen , Autoanticuerpos/sangre , Autoanticuerpos/inmunología , Dieta Alta en Grasa , Femenino , Colorantes Fluorescentes/metabolismo , Semivida , Humanos , Inmunohistoquímica , Lipoproteínas LDL/inmunología , Macrófagos/citología , Macrófagos/inmunología , Malondialdehído/química , Metaloproteinasas de la Matriz/metabolismo , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Microscopía Confocal , Microscopía Fluorescente , Extractos Vegetales , Conejos , Receptores de LDL/deficiencia , Receptores de LDL/genética , Microtomografía por Rayos X
17.
J Am Coll Cardiol ; 67(3): 275-87, 2016 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-26796392

RESUMEN

BACKGROUND: In patients with myocardial infarction (MI), leaflet tethering by displaced papillary muscles induces mitral regurgitation (MR), which doubles mortality. Mitral valves (MVs) are larger in such patients but fibrosis sets in counterproductively. The investigators previously reported that experimental tethering alone increases mitral valve area in association with endothelial-to-mesenchymal transition. OBJECTIVES: The aim of this study was to explore the clinically relevant situation of tethering and MI, testing the hypothesis that ischemic milieu modifies mitral valve adaptation. METHODS: Twenty-three adult sheep were examined. Under cardiopulmonary bypass, the papillary muscle tips in 6 sheep were retracted apically to replicate tethering, short of producing MR (tethered alone). Papillary muscle retraction was combined with apical MI created by coronary ligation in another 6 sheep (tethered plus MI), and left ventricular remodeling was limited by external constraint in 5 additional sheep (left ventricular constraint). Six sham-operated sheep were control subjects. Diastolic mitral valve surface area was quantified by 3-dimensional echocardiography at baseline and after 58 ± 5 days, followed by histopathology and flow cytometry of excised leaflets. RESULTS: Tethered plus MI leaflets were markedly thicker than tethered-alone valves and sham control subjects. Leaflet area also increased significantly. Endothelial-to-mesenchymal transition, detected as α-smooth muscle actin-positive endothelial cells, significantly exceeded that in tethered-alone and control valves. Transforming growth factor-ß, matrix metalloproteinase expression, and cellular proliferation were markedly increased. Uniquely, tethering plus MI showed endothelial activation with vascular adhesion molecule expression, neovascularization, and cells positive for CD45, considered a hematopoietic cell marker. Tethered plus MI findings were comparable with external ventricular constraint. CONCLUSIONS: MI altered leaflet adaptation, including a profibrotic increase in valvular cell activation, CD45-positive cells, and matrix turnover. Understanding cellular and molecular mechanisms underlying leaflet adaptation and fibrosis could yield new therapeutic opportunities for reducing ischemic MR.


Asunto(s)
Insuficiencia de la Válvula Mitral , Válvula Mitral , Infarto del Miocardio , Músculos Papilares/patología , Adaptación Fisiológica , Animales , Proliferación Celular/fisiología , Modelos Animales de Enfermedad , Ecocardiografía Tridimensional/métodos , Transición Epitelial-Mesenquimal/fisiología , Metaloproteinasas de la Matriz/metabolismo , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/metabolismo , Insuficiencia de la Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/fisiopatología , Infarto del Miocardio/complicaciones , Infarto del Miocardio/metabolismo , Infarto del Miocardio/patología , Ovinos , Factor de Crecimiento Transformador beta/metabolismo , Remodelación Ventricular/fisiología
18.
Int J Cardiovasc Imaging ; 31(2): 259-68, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25341407

RESUMEN

Intravascular optical coherence tomography (IVOCT) is a well-established method for the high-resolution investigation of atherosclerosis in vivo. Intravascular near-infrared fluorescence (NIRF) imaging is a novel technique for the assessment of molecular processes associated with coronary artery disease. Integration of NIRF and IVOCT technology in a single catheter provides the capability to simultaneously obtain co-localized anatomical and molecular information from the artery wall. Since NIRF signal intensity attenuates as a function of imaging catheter distance to the vessel wall, the generation of quantitative NIRF data requires an accurate measurement of the vessel wall in IVOCT images. Given that dual modality, intravascular OCT-NIRF systems acquire data at a very high frame-rate (>100 frames/s), a high number of images per pullback need to be analyzed, making manual processing of OCT-NIRF data extremely time consuming. To overcome this limitation, we developed an algorithm for the automatic distance-correction of dual-modality OCT-NIRF images. We validated this method by comparing automatic to manual segmentation results in 180 in vivo images from six New Zealand White rabbit atherosclerotic after indocyanine-green injection. A high Dice similarity coefficient was found (0.97 ± 0.03) together with an average individual A-line error of 22 µm (i.e., approximately twice the axial resolution of IVOCT) and a processing time of 44 ms per image. In a similar manner, the algorithm was validated using 120 IVOCT clinical images from eight different in vivo pullbacks in human coronary arteries. The results suggest that the proposed algorithm enables fully automatic visualization of dual modality OCT-NIRF pullbacks, and provides an accurate and efficient calibration of NIRF data for quantification of the molecular agent in the atherosclerotic vessel wall.


Asunto(s)
Algoritmos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/metabolismo , Vasos Coronarios/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagen Molecular/métodos , Imagen Óptica/métodos , Espectroscopía Infrarroja Corta/métodos , Tomografía de Coherencia Óptica/métodos , Animales , Automatización , Enfermedad de la Arteria Coronaria/metabolismo , Enfermedad de la Arteria Coronaria/patología , Modelos Animales de Enfermedad , Colorantes Fluorescentes , Humanos , Verde de Indocianina , Valor Predictivo de las Pruebas , Conejos , Reproducibilidad de los Resultados
19.
Phys Med Biol ; 57(20): 6395-406, 2012 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-22996051

RESUMEN

Intravascular near-infrared fluorescence (iNIRF) imaging can enable the in vivo visualization of biomarkers of vascular pathology, including high-risk plaques. The technique resolves the bio-distribution of systemically administered fluorescent probes with molecular specificity in the vessel wall. However, the geometrical variations that may occur in the distance between fibre-tip and vessel wall can lead to signal intensity variations and challenge quantification. Herein we examined whether the use of anatomical information of the cross-section vessel morphology, obtained from co-registered intravascular ultrasound (IVUS), can lead to quantification improvements when fibre-tip and vessel wall distance variations are present. The algorithm developed employs a photon propagation model derived from phantom experiments that is used to calculate the relative attenuation of fluorescence signals as they are collected over 360° along the vessel wall, and utilizes it to restore accurate fluorescence readings. The findings herein point to quantification improvements when employing hybrid iNIRF, with possible implications to the clinical detection of high-risk plaques or blood vessel theranostics.


Asunto(s)
Vasos Sanguíneos/metabolismo , Imagen Óptica/métodos , Algoritmos , Animales , Imagen Óptica/instrumentación , Fantasmas de Imagen , Fotones , Conejos
20.
J Vis Exp ; (54)2011 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-21847078

RESUMEN

The vascular response to injury is a well-orchestrated inflammatory response triggered by the accumulation of macrophages within the vessel wall leading to an accumulation of lipid-laden intra-luminal plaque, smooth muscle cell proliferation and progressive narrowing of the vessel lumen. The formation of such vulnerable plaques prone to rupture underlies the majority of cases of acute myocardial infarction. The complex molecular and cellular inflammatory cascade is orchestrated by the recruitment of T lymphocytes and macrophages and their paracrine effects on endothelial and smooth muscle cells.(1) Molecular imaging in atherosclerosis has evolved into an important clinical and research tool that allows in vivo visualization of inflammation and other biological processes. Several recent examples demonstrate the ability to detect high-risk plaques in patients, and assess the effects of pharmacotherapeutics in atherosclerosis.(4) While a number of molecular imaging approaches (in particular MRI and PET) can image biological aspects of large vessels such as the carotid arteries, scant options exist for imaging of coronary arteries.(2) The advent of high-resolution optical imaging strategies, in particular near-infrared fluorescence (NIRF), coupled with activatable fluorescent probes, have enhanced sensitivity and led to the development of new intravascular strategies to improve biological imaging of human coronary atherosclerosis. Near infrared fluorescence (NIRF) molecular imaging utilizes excitation light with a defined band width (650-900 nm) as a source of photons that, when delivered to an optical contrast agent or fluorescent probe, emits fluorescence in the NIR window that can be detected using an appropriate emission filter and a high sensitivity charge-coupled camera. As opposed to visible light, NIR light penetrates deeply into tissue, is markedly less attenuated by endogenous photon absorbers such as hemoglobin, lipid and water, and enables high target-to-background ratios due to reduced autofluorescence in the NIR window. Imaging within the NIR 'window' can substantially improve the potential for in vivo imaging.(2,5) Inflammatory cysteine proteases have been well studied using activatable NIRF probes(10), and play important roles in atherogenesis. Via degradation of the extracellular matrix, cysteine proteases contribute importantly to the progression and complications of atherosclerosis(8). In particular, the cysteine protease, cathepsin B, is highly expressed and colocalizes with macrophages in experimental murine, rabbit, and human atheromata.(3,6,7) In addition, cathepsin B activity in plaques can be sensed in vivo utilizing a previously described 1-D intravascular near-infrared fluorescence technology(6), in conjunction with an injectable nanosensor agent that consists of a poly-lysine polymer backbone derivatized with multiple NIR fluorochromes (VM110/Prosense750, ex/em 750/780nm, VisEn Medical, Woburn, MA) that results in strong intramolecular quenching at baseline.(10) Following targeted enzymatic cleavage by cysteine proteases such as cathepsin B (known to colocalize with plaque macrophages), the fluorochromes separate, resulting in substantial amplification of the NIRF signal. Intravascular detection of NIR fluorescence signal by the utilized novel 2D intravascular NIRF catheter now enables high-resolution, geometrically accurate in vivo detection of cathepsin B activity in inflamed plaque. In vivo molecular imaging of atherosclerosis using catheter-based 2D NIRF imaging, as opposed to a prior 1-D spectroscopic approach,(6) is a novel and promising tool that utilizes augmented protease activity in macrophage-rich plaque to detect vascular inflammation.(11,12) The following research protocol describes the use of an intravascular 2-dimensional NIRF catheter to image and characterize plaque structure utilizing key aspects of plaque biology. It is a translatable platform that when integrated with existing clinical imaging technologies including angiography and intravascular ultrasound (IVUS), offers a unique and novel integrated multimodal molecular imaging technique that distinguishes inflammatory atheromata, and allows detection of intravascular NIRF signals in human-sized coronary arteries.


Asunto(s)
Aterosclerosis/patología , Imagen Molecular/métodos , Placa Aterosclerótica/patología , Espectrometría de Fluorescencia/métodos , Espectroscopía Infrarroja Corta/métodos , Animales , Aterosclerosis/metabolismo , Humanos , Placa Aterosclerótica/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...