Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Wound Care ; 32(Sup5): S6-S10, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37121665

RESUMEN

OBJECTIVE: The objective of the current study was to evaluate outcomes of elective knee arthroscopy portal closure comparing two skin closure techniques. METHOD: This was a randomised controlled trial including healthy volunteers aged ≥18 years undergoing elective knee arthroscopy that used two portals. At the time of surgery, each patient's two arthroscopy portal closures were randomised to one of two closure techniques; the first technique used approximation of the skin with a micro-anchor skin dressing (BandGrip Inc., US), while the second closure technique used an absorbable suture (Biosyn Monofilament, Medtronic) and a liquid bonding agent skin closure (Dermabond, Ethicon Inc., US). Postoperative complications and patient-reported outcomes were evaluated at the first visit after knee arthroscopy and at six weeks postoperatively. RESULTS: A total of 38 patients (76 portals) were enrolled in this study. No patients reported wound complications of either portal; thus, there was no significant difference (p>0.05) in wound complication rates between the skin closure techniques. Survey questions regarding any difference in appearance and cosmesis between the closure techniques' portal sites were responded to by 15 patients, all of whom indicated no difference in appearance between the portal sites. There was also no statistically significant difference between the two closure techniques with regards to appearance. CONCLUSION: There was no significant difference in presence of wound complications or appearance between skin closure with the micro-anchor skin dressing and the absorbable suture/liquid bonding agent skin closure.


Asunto(s)
Artroscopía , Articulación de la Rodilla , Humanos , Adolescente , Adulto , Articulación de la Rodilla/cirugía , Complicaciones Posoperatorias , Técnicas de Cierre de Heridas , Vendajes
2.
Am J Transplant ; 23(3): 408-415, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36695692

RESUMEN

Advanced practice providers (APPs) are trained, licensed health care providers. The American Society of Transplant APP community of practice developed an electronic survey to investigate transplant APP demographics, scope of practice, and academic activities. We defined the top of scope of practice as delivering health care to the fullest extent of APP education and training as allowed by state laws and regulations. From July 11, 2020, to August 31, 2020, 307 invitations were e-mailed and survey links were distributed electronically on the community of practice hub and social media. Two hundred fifty-three APPs responded. APPs practice in inpatient and outpatient settings. Among the respondent APPs, 11.5% assist in the operating room (OR), 46.3% of inpatient and 46.6% of outpatient APPs perform procedures, and 17.8% run specialized APP clinics. 26.2% feel they do not function at the top of their scope of practice and 29.7% were expected to function as a coordinator some or all of the time. Forty-three percent gave invited lectures, 41.5% have published, and 69.2% teach physician trainees. 74.7% and 35.1%, respectively, would like to participate in research and teach but are limited by time, opportunity, and experience. APPs should practice at the top of their scope of practice. Clinical workloads and lack of time limit the ability of APP to teach and contribute to evidence-based practice.


Asunto(s)
Enfermería de Práctica Avanzada , Atención a la Salud , Trasplante , Humanos , Instituciones de Salud , Encuestas y Cuestionarios , Factores de Tiempo , Trasplante/enfermería
3.
J Surg Orthop Adv ; 26(3): 166-172, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29130878

RESUMEN

Extensor mechanism complications involving the patella frequently result in total knee arthroplasty (TKA) failure. Postoperative patellar dislocation may be caused by soft tissue imbalance, improper sizing, and position of the prosthesis. This report describes a case of revision TKA requiring several rounds of soft tissue releases in an effort to treat the patient's chronic patellar dislocation. In the process, a novel surgical approach was developed for the surgical management of refractory chronic patellar dislocations. Postoperative follow-up at 1, 2, 6, 12, and 24 months indicated no complaints of patellar subluxation or dislocation. Plain films also demonstrated no effusion, fracture, or patellar dislocation on sunrise, anteroposterior, and lateral views. This novel anatomic repositioning of the vastus lateralis around the quadriceps tendon converted a pathologic lateralizing force into a medial stabilizer. On follow-up evaluations, successful patellar tracking without dislocation has been demonstrated. (Journal of Surgical Orthopaedic Advances.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Luxación de la Rótula/cirugía , Músculo Cuádriceps/cirugía , Femenino , Humanos , Persona de Mediana Edad , Luxación de la Rótula/etiología , Complicaciones Posoperatorias , Reoperación , Tendones/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...