Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Asian Pac J Cancer Prev ; 25(5): 1529-1538, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38809624

RESUMEN

AIM: To evaluate the out-of-field dose associated with flattened (FF) and flattening filter-free (FFF) 6 and 10 MV X-ray beams in a TrueBeam linear accelerator (Linac). MATERIALS AND METHODS: Measurements were taken in a slab phantom using the metal oxide semiconductor field effect transistor (MOSFET) detector at varying depths (dmax, 5 cm, and 10 cm) for clinically relevant field sizes and up to 30 cm from the field edges for 6 and 10 MV FF and FFF beams in TrueBeam Linac. Dose calculation accuracy of the analytic anisotropic algorithm (AAA) and Acuros algorithm was investigated in the out-of-field region. Similarly, the out-of-field dose associated with volumetric modulated arc therapy (VMAT) head-and-neck plan delivered to a body phantom was evaluated. RESULTS: The out-of-field dose for both FF and FFF photon beams (6 and 10 MV) decreased with increasing distance from the field boundary and size. Furthermore, regardless of FF in the field, higher-energy photon beams were associated with lower out-of-field dose. Both algorithms underestimated the dose in the out-of-field region, with AAA failing to calculate the out-of-field dose at 15 cm from the field edge and Acuros failing to calculate out-of-field radiation at 20 cm. At 5 cm from the field edge, an average of 50% underestimation was observed, and at 10 cm, an average of 60% underestimation was observed for both FF and FFF (6 and 10 MV) beams. The VMAT head-and-neck plan performed with the FFF beam resulted in a lower out-of-field dose than the FF beam for a comparable dose distribution. CONCLUSION: Compared with flattened beams, the FFF modes on TrueBeam Linac exhibited a clinically relevant reduction in the out-of-field dose. Further dosimetric studies are warranted to determine the significant benefit of FFF beams across different cancer sites.


Asunto(s)
Algoritmos , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Aceleradores de Partículas/instrumentación , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Rayos X , Neoplasias de Cabeza y Cuello/radioterapia , Fotones/uso terapéutico
2.
J Cancer Res Ther ; 19(3): 543-547, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37470572

RESUMEN

Introduction: Head and neck cancers are one of the common malignancies in Indian population. It's entity, nasopharyngeal carcinoma is among the aggressive malignancies with its location and spread near very critical structures. Thus requires a highly conformal radiotherapy delivery techniques. Purpose: The aim of the study is to dosimetrically evaluate and to compare Intensity modulated radiation therapy (IMRT) plans and RAPID ARC plans for irradiation of nasopharyngeal carcinoma. Material and Method: A retrospective study is done on 10 nasopharyngeal carcinoma patients, who were treated with Radiotherapy at ATRCTRI Bikaner. Radiotherapy was delivered by IMRT technique (Total of 70 Gy in 33 fractions). Same patients are now planned on Rapid arc technique. Dosimetric comparison is done in terms of PTV coverage, OAR dose, conformity index, homogeneity index. Result: PTV coverage is similar with both the plans. Homogeneity index is higher for IMRT plans 0.119+/- 0.020 compared to 0.104 +/- 0.018 for Rapid arc plans (statistically significant).The Rapid arc plans achieved slightly better conformity 1.018+/-0.09, whereas 1.105+/-0.12 for IMRT plans. Rapid arc achieved better results for OAR, statistically significant for Brainstem (54.4 +/-10.4 Gy for IMRT and 49.7+/-4.2 Gy for Rapid Arc, Lens (Left lens and Right lens received 10.55+/-5.8 Gy and 9.44+/-9.08 by IMRT and 6.12+/-6.1 Gy and 5.45+/-6.05 Gy for Rapid Arc), optic nerves (Right and Left optic nerve received 34.36 and 35.01 Gy for IMRT plans and 30.06 and 30.05 Gy for Rapid Arc plans. However the gains are statistically insignificant for spinal cord and vestibulocochlear nerve. No major difference found for Right and left parotid between both the arms. Conclusions: Rapid Arc is better technique compared to IMRT for Nasopharyngeal carcinoma treatment, that provides better dose conformity, more homogeneous coverage and OAR sparing. However study is retrospective and has lesser patients, thus requires prospective study with more number of patients along with comparison of clinical outcome.


Asunto(s)
Neoplasias Nasofaríngeas , Radioterapia de Intensidad Modulada , Humanos , Carcinoma Nasofaríngeo/radioterapia , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Dosificación Radioterapéutica , Estudios Prospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Nasofaríngeas/patología
3.
Rep Pract Oncol Radiother ; 24(5): 409-420, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31333335

RESUMEN

AIM: To estimate and compare the lifetime attributable risk (LAR) of radiation-induced second cancer (SC) in pediatric medulloblastoma patients planned with institutional 3D conformal field matching method, gap junction method and Intensity Modulated Radiotherapy (IMRT). BACKGROUND: The epidemiological studies on childhood cancer survivors reported that long-term cancer survivors who received radiotherapy are at a significantly increased risk for the development of SC. Hence, the increased concern to predict the SC risk for long-term survivors. MATERIALS AND METHODS: In addition to institutional field matching planning method, IMRT and gap junction methods were created for ten pediatric medulloblastoma patients. The risk estimates were made based on the site-specific cancer risk coefficient provided by the BEIR VII committee according to the organ equivalent dose for various critical organs. Also, plans were compared for target volume dose distribution and dose received by critical organs. RESULTS: When compared to the gap junction method, the IMRT and institutional field matching method were superior in normal tissue sparing and dose conformity. However, highly significant volume of low dose associated with IMRT was the main concern for the SC risk. The accumulated LAR for all the critical organs with 3D conformal gap junction and IMRT method was 23-25% while for the 3D conformal field matching method it was 21%. CONCLUSION: The LAR associated with the institutional field matching technique was substantially lower. As this method is highly robust and easy to set up, it can be a better choice of a craniospinal irradiation technique where 3DCRT is the only choice of treatment.

4.
J Cancer Res Ther ; 11(3): 662, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26458685

RESUMEN

Treatment of carcinoma cervix is a complex issue influenced by numerous factors, including the patient's age, clinical stage of the disease, position of the uterus, comorbidities, etc. The major drawback of the conventional four-field box technique is the lack of complete information about the flexion of the uterus and topography of the tumor. These are further influenced by bladder and rectal filling, which may lead to geographical miss of the clinical target volume (CTV). This problem was noticed mainly in the anterior and posterior borders of the lateral fields and in the superior and lateral borders of the anteroposterior fields. We demonstrate the need for computed tomographic-magnetic resonance imaging (MRI)-based 3D planning of each patient and necessity of sagittal MRI for designing lateral portal in case of conventional four-field technique through an example of a patient's sagittal MRI of pelvis showing retroverted uterus.


Asunto(s)
Neoplasias del Cuello Uterino/diagnóstico por imagen , Retroversión Uterina/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/terapia
5.
J Med Phys ; 39(4): 251-8, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25525314

RESUMEN

A new planning method for Craniospinal Irradiation by Eclipse treatment planning system using Field alignment, Field-in-Field technique was developed. Advantage of this planning method was also studied retrospectively for previously treated five patients of medulloblastoma with variable spine length. Plan consists of half beam blocked parallel opposed cranium, and a single posterior cervicospine field was created by sharing the same isocenter, which obviates divergence matching. Further, a single symmetrical field was created to treat remaining Lumbosacral spine. Matching between a inferior diverging edge of cervicospine field and superior diverging edge of a Lumbosacral field was done using the field alignment option. 'Field alignment' is specific option in the Eclipse Treatment Planning System, which automatically matches the field edge divergence as per field alignment rule. Multiple segments were applied in both the spine field to manage with hot and cold spots created by varying depth of spinal cord. Plan becomes fully computerized using this field alignment option and multiple segments. Plan evaluation and calculated mean modified Homogeneity Index (1.04 and 0.1) ensured that dose to target volume is homogeneous and critical organ doses were within tolerance. Dose variation at the spinal field junction was verified using ionization chamber array (I'MatriXX) for matched, overlapped and gap junction spine fields; the delivered dose distribution confirmed the ideal clinical match, over exposure and under exposure at the junction, respectively. This method is simple to plan, executable in Record and Verify mode and can be adopted for various length of spinal cord with only two isocenter in shorter treatment time.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA