Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
IEEE Trans Biomed Circuits Syst ; 12(6): 1267-1277, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30489273

RESUMEN

This paper presents a sub-mW ASIC for multimodal brain monitoring. The ASIC is co-integrated with electrode(s) and optodes (i.e., optical source and detector) as an active sensor to measure electroencephalography (EEG), bio-impedance (BioZ), and near-infrared spectroscopy (NIRS) on scalp. The target is to build a wearable EEG-NIRS headset for low-cost functional brain imaging. The proposed NIRS readout utilizes the near-infrared light to measure the pulse oximetry and blood oxygen saturation (SpO2). While traditional photodiodes are supported, the readout also allows the use of silicon photomultipliers (SiPMs) as optical detectors. The SiPM improves optical sensitivity while significantly reducing the average power of two LEDs to 150 µW. On circuit level, a SAR-based calibration compensates maximum 40 µA current from ambient light, while digital DC-servo loops reduces the baseline static SiPM current up to 400 µA, leading to an overall dynamic range of 87 dB. The EEG readout exhibits 720 MΩ input impedance at 50 Hz. The BioZ readout has 3 mΩ/√(Hz) impedance sensitivity by employing dynamic circuit techniques. When EEG, BioZ, and NIRS are enabled at the same time, one ASIC consumes 665 µW including the power of LEDs.


Asunto(s)
Electroencefalografía/instrumentación , Neuroimagen Funcional/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Espectroscopía Infrarroja Corta/instrumentación , Dispositivos Electrónicos Vestibles , Encéfalo/fisiología , Equipos y Suministros Eléctricos , Diseño de Equipo , Humanos , Masculino
2.
Biomed Opt Express ; 9(10): 4679-4688, 2018 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-30319895

RESUMEN

In this work, we investigate some major issues for the use of silicon photomultiplier (SiPM) devices in continuous wave functional near-infrared spectroscopy (CW fNIRS). We analyzed the after-pulsing effect, proposing the physical mechanism causing it, and determining its relevance for CW fNIRS. We studied the SiPM transients occurring as the SiPM device goes from the dark (LED in off state) to the illumination (LED in on state) conditions, and vice-versa. Finally, we studied the SiPM SNR in standard CW fNIRS operation.

3.
Neurophotonics ; 4(3): 035002, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28983487

RESUMEN

We report development, testing, and in vivo characterization of a multichannel optical probe for continuous wave (CW) functional near-infrared spectroscopy (fNIRS) that relies on silicon photomultipliers (SiPMs) detectors. SiPMs are cheap, low voltage, and robust semiconductor light detectors with performances analogous to photomultiplier tubes (PMTs). In contrast with PMTs, SiPMs allow direct contact with the head and transfer of the analog signals through thin cables greatly increasing the system flexibility avoiding optical fibers. The coupling of SiPMs and light-emitting diodes (LEDs) made the optical probe lightweight and robust against motion artifacts. After characterization of SiPM performances, which was proven to provide a noise equivalent power below 3 fW, the apparatus was compared through an in vivo experiment to a commercial system relying on laser diodes, PMTs, and optical fibers for light probing and detection. The optical probes were located over the primary sensorimotor cortex and the similarities between the hemodynamic responses to the contralateral motor task were assessed. When compared to other state-of-the-art wearable fNIRS systems, where photodiode detectors are employed, the single photon sensitivity and dynamic range of SiPMs can fully exploit the long and variable interoptode distances needed for correct estimation of brain hemodynamics using CW-fNIRS.

4.
Sensors (Basel) ; 10(12): 10828-36, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-22163500

RESUMEN

New equations for paralyzable, non paralyzable and hybrid DT models, valid for any time dependent sources are presented. We show how such new equations include the equations already used for constant rate sources, and how it's is possible to correct DT losses in the case of time dependent sources. Montecarlo simulations were performed to compare the equations behavior with the three DT models. Excellent accordance between equations predictions and Montecarlo simulation was found. We also obtain good results in the experimental validation of the new hybrid DT equation. Passive quenched SPAD device was chosen as a device affected by hybrid DT losses and active quenched SPAD with 50 ns DT was used as DT losses free device.


Asunto(s)
Cómputos Matemáticos , Modelos Teóricos , Procesamiento de Señales Asistido por Computador , Simulación por Computador , Generalización Psicológica , Láseres de Semiconductores/normas , Modelos Biológicos , Método de Montecarlo , Procesamiento de Señales Asistido por Computador/instrumentación , Factores de Tiempo
5.
Sensors (Basel) ; 8(8): 4636-4655, 2008 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-27873777

RESUMEN

Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs). Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA