Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 209
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599690

RESUMEN

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodos
2.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38456883

RESUMEN

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Hemodinámica , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
3.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38471643

RESUMEN

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Asunto(s)
Cardiomiopatía Hipertrófica , Implantación de Prótesis de Válvulas Cardíacas , Miotomía , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Cateterismo Cardíaco/métodos , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento , Cardiomiopatía Hipertrófica/complicaciones , Miotomía/efectos adversos
5.
CASE (Phila) ; 8(3Part A): 180-185, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38524970

RESUMEN

•Degenerative common AVC defect can mimic rheumatic MV stenosis.•Closure of primum ASD can be achieved percutaneously.•Live 3D multiplanar TEE is crucial for procedural guidance.

6.
Cryst Growth Des ; 24(6): 2567-2572, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38525101

RESUMEN

Savolitinib is a compound that can crystallize in an undesirable, high aspect ratio needle morphology. This morphology type may cause issues in downstream processing. This paper demonstrates a unique method to alter the crystal morphology of savolitinib to make it more processable, resulting in the active pharmaceutical ingredient (API) crystallizing out in considerably more processable stellates. The volatile deep eutectic solvent technique presents a simple and scalable method for changing the crystal morphology while maintaining the polymorph of the API in this case, confirmed via powder X-ray diffraction and differential scanning calorimetry analysis.

7.
Eur J Drug Metab Pharmacokinet ; 49(2): 229-237, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38329646

RESUMEN

BACKGROUND AND OBJECTIVES: Ocedurenone (KBP-5074) is a novel nonsteroidal mineralocorticoid receptor antagonist that has demonstrated safety and efficacy in clinical trials in patients with uncontrolled hypertension and stage 3b/4 chronic kidney disease. The aim of this study was to assess the pharmacokinetics, safety, and tolerability of ocedurenone in individuals with moderate hepatic impairment. METHODS: This study was an open-label, nonrandomized, multi-center study investigating the pharmacokinetics, safety, and tolerability of a single dose of 0.5 mg ocedurenone administered orally in male and female subjects with moderate hepatic impairment (Child-Pugh B, score 7-9) compared with subjects with normal hepatic function. Serial blood samples were obtained from predose through 264 h postdose for analysis of ocedurenone concentrations using a validated liquid chromatography-tandem mass spectrometry method. Free ocedurenone concentrations in plasma were determined ex vivo using equilibrium dialysis. RESULTS: Following a single oral dose of 0.5 mg ocedurenone administered to subjects with moderate hepatic impairment and subjects with normal hepatic function, ocedurenone was steadily absorbed with median time to peak drug concentration (Tmax) values of 4 and 3 h, respectively. After reaching maximum plasma concentration (Cmax), the disposition of ocedurenone appeared to be biphasic. The geometric mean t1/2 values for the moderate hepatic impairment group and normal hepatic function group were 75.6 and 65.7 h, respectively. Ocedurenone systemic exposure, as assessed by area under the plasma concentration-time curve (AUC) was 23.5-26.6% lower in subjects with moderate hepatic impairment versus subjects with normal hepatic function, whereas Cmax was 41.2% lower. Ocedurenone was determined to be > 99.7% bound to total protein in plasma. Hepatic impairment appeared not to change plasma protein binding or the unbound free fraction. Ocedurenone was safe and well-tolerated in all participants. CONCLUSIONS: Considering the long half-life of ocedurenone and previously completed clinical studies using 0.25 mg and 0.5 mg doses demonstrating efficacy and safety, the observed decreases in AUC and Cmax do not warrant a dose adjustment in patients with moderate hepatic impairment. A single 0.5 mg dose of ocedurenone was safe and well-tolerated when administered to subjects with moderate hepatic impairment and subjects with normal hepatic function. CLINICAL TRIAL IDENTIFIER ( WWW. CLINICALTRIALS: GOV ): NCT04534699.


Asunto(s)
Hepatopatías , Piperidinas , Pirazoles , Quinolinas , Insuficiencia Renal Crónica , Humanos , Masculino , Femenino , Antagonistas de Receptores de Mineralocorticoides , Área Bajo la Curva , Hepatopatías/metabolismo
11.
Artículo en Inglés | MEDLINE | ID: mdl-38126354

RESUMEN

Single-crystal X-ray diffraction analysis of small molecule active pharmaceutical ingredients is a key technique in the confirmation of molecular connectivity, including absolute stereochemistry, as well as the solid-state form. However, accessing single crystals suitable for X-ray diffraction analysis of an active pharmaceutical ingredient can be experimentally laborious, especially considering the potential for multiple solid-state forms (solvates, hydrates and polymorphs). In recent years, methods for the exploration of experimental crystallization space of small molecules have undergone a `step-change', resulting in new high-throughput techniques becoming available. Here, the application of high-throughput encapsulated nanodroplet crystallization to a series of six dihydropyridines, calcium channel blockers used in the treatment of hypertension related diseases, is described. This approach allowed 288 individual crystallization experiments to be performed in parallel on each molecule, resulting in rapid access to crystals and subsequent crystal structures for all six dihydropyridines, as well as revealing a new solvate polymorph of nifedipine (1,4-dioxane solvate) and the first known solvate of nimodipine (DMSO solvate). This work further demonstrates the power of modern high-throughput crystallization methods in the exploration of the solid-state landscape of active pharmaceutical ingredients to facilitate crystal form discovery and structural analysis by single-crystal X-ray diffraction.


Asunto(s)
Medicamentos a Granel , Dihidropiridinas , Cristalización/métodos , Cristalografía por Rayos X , Bloqueadores de los Canales de Calcio , Difracción de Rayos X
12.
JACC Case Rep ; 26: 102069, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38094178

RESUMEN

We present a series of 2 high-risk surgical patients undergoing transcatheter aortic valve replacement via alternative access owing to unacceptable transfemoral options. Both patients underwent percutaneous transcarotid access with successful valve delivery and deployment without notable complication. To our knowledge, this approach has not been previously reported. (Level of Difficulty: Intermediate.).

13.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-37905772

RESUMEN

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Ensayos Clínicos como Asunto
15.
JACC Cardiovasc Interv ; 16(18): 2211-2227, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37758379

RESUMEN

BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective trial to evaluate the safety and feasibility of balloon-expandable aortic transcatheter heart valves in patients with failed surgical bioprostheses or annuloplasty rings and severe mitral annular calcification treated with mitral valve-in-valve (MViV), valve-in-ring (MViR), or valve-in-mitral annular calcification (ViMAC). OBJECTIVES: The aim of this study was to evaluate 5-year outcomes among these patients. METHODS: A multicenter prospective study was conducted among patients at high surgical risk at 13 U.S. sites. Patients underwent MViV (n = 30), MViR (n = 30), or ViMAC (n = 31) and were followed annually for 5 years. Kansas City Cardiomyopathy Questionnaire scores were obtained at baseline and follow-up visits. Echocardiograms were analyzed at independent core laboratories. RESULTS: A total of 91 patients underwent transcatheter mitral valve replacement (February 2015 to December 2017). The mean age was 74.3 ± 8.9 years. At 5-year follow-up, the lowest all-cause mortality was observed in the MViV group (21.4%), 94.7% of patients were in NYHA functional class I or II, and the mean mitral gradient was 6.6 ± 2.5 mm Hg. The MViR and ViMAC groups had higher all-cause mortality (65.5% and 67.9%), most survivors were in NYHA functional classes I and II (50% and 55.6%), and mean mitral gradients remained stable (5.8 ± 0.1 and 6.7 ± 2.5 mm Hg). Significant improvements in Kansas City Cardiomyopathy Questionnaire scores were observed when all 3 arms were pooled. CONCLUSIONS: MViV, MViR, and ViMAC procedures were associated with sustained improvement of heart failure symptoms and quality of life among survivors at 5 years. Transcatheter heart valve function remained stable in all 3 groups. Patients treated with MViV had excellent survival at 5 years, whereas survival was lower in the MViR and ViMAC groups, consistent with underlying disease severity. Patients with more residual mitral regurgitation had higher mortality.


Asunto(s)
Calcinosis , Cardiomiopatías , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Enfermedades Vasculares , Humanos , Anciano , Anciano de 80 o más Años , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Calcinosis/cirugía , Enfermedades Vasculares/etiología
16.
Nat Commun ; 14(1): 5138, 2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37612269

RESUMEN

Structure determination of amorphous materials remains challenging, owing to the disorder inherent to these materials. Nuclear magnetic resonance (NMR) powder crystallography is a powerful method to determine the structure of molecular solids, but disorder leads to a high degree of overlap between measured signals, and prevents the unambiguous identification of a single modeled periodic structure as representative of the whole material. Here, we determine the atomic-level ensemble structure of the amorphous form of the drug AZD4625 by combining solid-state NMR experiments with molecular dynamics (MD) simulations and machine-learned chemical shifts. By considering the combined shifts of all 1H and 13C atomic sites in the molecule, we determine the structure of the amorphous form by identifying an ensemble of local molecular environments that are in agreement with experiment. We then extract and analyze preferred conformations and intermolecular interactions in the amorphous sample in terms of the stabilization of the amorphous form of the drug.

18.
Am J Hypertens ; 36(11): 612-618, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37471468

RESUMEN

BACKGROUND: Ocedurenone (KBP-5074), a nonsteroidal mineralocorticoid receptor antagonist, is documented to lower blood pressure in patients with stage 3b/4 chronic kidney disease (CKD) with uncontrolled or resistant hypertension (BLOCK-CKD study). However, the efficacy and safety of Ocedurenone in subgroups such as Hispanic patients or those with stage 4 CKD, diabetes, or very high albuminuria have not been reported. METHODS: A total of 162 patients were enrolled in the BLOCK-CKD study. The primary endpoint of these analyses was change in systolic blood pressure (SBP) from baseline to day 84. Prespecified subgroup analysis of SBP focused on demographic (e.g., ethnicity, age) and medical (e.g., CKD stage, diabetes, albuminuria, baseline estimated glomerular filtration rate [eGFR]). The safety analysis focused on changes in serum potassium levels from baseline. RESULTS: SBP reductions were consistent across subgroups compared with the overall study cohort. Placebo-adjusted SBP reductions were observed in Hispanic patients (-8.1 and -9.9 mm Hg for 0.25 and 0.5 mg, respectively, total n = 35) and patients with CKD stage 4 (-9.3 and -10.4 mm Hg for 0.25 and 0.5 mg, respectively, total n = 64), diabetes (-6.9 and -11.6 mm Hg for 0.25 and 0.5 mg, respectively, total n = 51), and very high albuminuria (-13.1 and -12.3 mm Hg for 0.25 and 0.5 mg, respectively, total n = 85). Changes in serum potassium were similar across all patient subgroups regardless of baseline eGFR, diabetes status, or degree of proteinuria. No cases of hyperkalemia required intervention or resulted in study discontinuation. CONCLUSIONS: Ocedurenone consistently reduced in SBP in all patient subgroups. Moreover, while small elevations in serum potassium occurred, they were not associated with Ocedurenone or study discontinuation.

19.
Eur J Drug Metab Pharmacokinet ; 48(4): 397-410, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37357226

RESUMEN

BACKGROUND AND OBJECTIVES: Ocedurenone (KBP-5074) is a novel nonsteroidal mineralocorticoid receptor antagonist that has demonstrated safety and efficacy in clinical trials in patients with uncontrolled hypertension and stage 3b/4 chronic kidney disease. This study evaluated the involvement of cytochrome P450 (CYP) isozymes and drug transporters in the biotransformation of ocedurenone, and whether ocedurenone inhibited or induced CYP enzymes and transporters. Clinical pharmacokinetic drug-drug interaction (DDI) of ocedurenone with CYP3A inhibitor and inducer were investigated in healthy volunteers. METHODS: In vitro tests were conducted to determine which CYP enzymes were involved in ocedurenone's metabolism and whether ocedurenone inhibited or induced these CYP enzymes; ocedurenone substrate characteristics for efflux and uptake transporters and its inhibitory potential on major drug transporters were also assessed. A clinical DDI study was conducted in healthy volunteers to evaluate the effects of a strong CYP3A inhibitor (itraconazole) and inducer (rifampin) on ocedurenone's pharmacokinetics. RESULTS: The in vitro study showed that ocedurenone was primarily metabolized by CYP3A4 and that it did not inhibit CYP enzymes. Ocedurenone appeared to be a substrate of BCRP and P-gp efflux transporters and inhibited BCRP, BSEP, MDR1, MATE1 and 2-K, OATP1B1/3, and OCT1. The clinical DDI study showed that itraconazole reduced ocedurenone's oral clearance by 51% and increased area under the plasma concentration-time curve extrapolated to infinity (AUC0-inf) by 104%, while rifampin increased its oral clearance by 6.4-fold and decreased plasma AUC0-inf by 84%. CONCLUSION: Ocedurenone was shown to be a CYP3A substrate, with no inhibition potential on major drug metabolizing CYP enzymes and transporters at clinical efficacious doses. Ocedurenone did not induce CYP1A2 and 3A4 activity in cultured human primary hepatocytes. Clinical DDI study indicated ocedurenone was well tolerated when administered as a single 0.5-mg dose both alone and with itraconazole or rifampin, and while itraconazole had a weak effect on ocedurenone's pharmacokinetics, rifampin had a significant effect reducing systemic exposures.


Asunto(s)
Inhibidores del Citocromo P-450 CYP3A , Rifampin , Humanos , Inhibidores del Citocromo P-450 CYP3A/farmacología , Itraconazol/farmacología , Inductores del Citocromo P-450 CYP3A/farmacocinética , Transportador de Casetes de Unión a ATP, Subfamilia G, Miembro 2/metabolismo , Área Bajo la Curva , Proteínas de Neoplasias , Sistema Enzimático del Citocromo P-450/metabolismo , Interacciones Farmacológicas , Citocromo P-450 CYP3A/metabolismo
20.
Struct Heart ; 7(3): 100164, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37273856

RESUMEN

Background: Cardiac computed tomography angiography was used to identify anatomical characteristics of the aortic root in patients with severe aortic regurgitation (AR) as compared to those with aortic stenosis (AS) to judge feasibility of transcatheter aortic valve replacement (TAVR) with the JenaValve Trilogy system. Methods: Cardiac computed tomography angiography was performed prior to planned TAVR for 107 patients with severe AR and 92 patients with severe AS. Measurements related to aortic root and coronary artery anatomy were obtained and compared between groups. Perimeter >90 mm and aortic annulus angle â€‹>70 degrees were defined as the theoretical exclusion criteria for TAVR. A combination of sinus of Valsalva diameter <30 mm and coronary height <12 mm was defined as high risk for coronary occlusion. Results: The mean age of patients in the AR group was 74.9 ± 11.2 years, 46% were women, and the mean Society of Thoracic Surgeons risk score for mortality was 3.6 ± 2.1. Comparatively, the mean age of patients in the AS group was 82.3 ± 5.53 years, 65% were women, and the mean Society of Thoracic Surgeonsrisk score was 5.5 ± 3.3. Annulus area, perimeter, diameter, and angle were larger in patients with severe AR. Sinus of Valsalva diameters and heights were larger in patients with severe AR. More AR patients were excluded based on perimeter (14 vs. 2%) and annulus angle (6 vs. 1%). More AS patients exhibited high-risk anatomy for left main coronary occlusion (21 vs. 7%) and right coronary occlusion (14 vs. 3%). The maximum dimension of the ascending aorta was larger in patients with severe AR (39 vs. 35 mm). The percentage of referred AR patients with significant aortopathy requiring surgical intervention was very low (only 1 AR patient with ascending aorta diameter >5.5 cm). Conclusions: A significantly larger proportion of patients with severe AR are excluded from TAVR as compared to AS due to large aortic annulus size and steep annulus angulation. By far the most prevalent excluding factor is aortic annulus size, with fewer patients excluded due to angulation. AR patients have lower-risk anatomy for coronary occlusion. Larger transcatheter valve sizes and further delivery system modifications are required to treat a larger proportion of AR patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...