Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Hormones (Athens) ; 20(3): 587-589, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33881757

RESUMEN

Primary hyperparathyroidism (pHPT) is a common endocrine disorder. Often serum calcium is minimally elevated with few symptoms. In elderly patients with multiple co-morbidities, the decision to "watch and wait" is often most clinically appropriate as operative intervention is associated with high peri-operative risk. We present an elderly patient with mild hypercalcemia secondary to primary hyperparathyroidism. The clinical decision was initially to watch and wait. The patient subsequently developed cognitive impairment and was diagnosed with mixed Alzheimer's disease/vascular dementia. She became dependent for all care and housebound. A therapeutic trial of cinacalcet was commenced following a further acute rise in serum calcium. Significant reversal of her functional and cognitive deficit occurred. She was no longer fully dependent. Mini mental state examination (MMSE) improved from 8/30 to 21/30. In vulnerable neural systems, even mild elevation in serum calcium may have a profound effect on cognition and function. We propose a therapeutic trial of cinacalcet in such patients.


Asunto(s)
Disfunción Cognitiva , Hipercalcemia , Hiperparatiroidismo Primario , Anciano , Calcio/sangre , Cinacalcet/uso terapéutico , Disfunción Cognitiva/tratamiento farmacológico , Disfunción Cognitiva/etiología , Femenino , Humanos , Hipercalcemia/tratamiento farmacológico , Hipercalcemia/etiología , Hiperparatiroidismo Primario/sangre , Hiperparatiroidismo Primario/complicaciones , Hiperparatiroidismo Primario/tratamiento farmacológico , Naftalenos/uso terapéutico , Hormona Paratiroidea/sangre
2.
AJNR Am J Neuroradiol ; 41(11): 2034-2040, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33004342

RESUMEN

BACKGROUND AND PURPOSE: Infarct core volume measurement using CTP (CT perfusion) is a mainstay paradigm for stroke treatment decision-making. Yet, there are several downfalls with cine CTP technology that can be overcome by adopting the simple perfusion reconstruction algorithm (SPIRAL) derived from multiphase CTA. We compare SPIRAL with CTP parameters for the prediction of 24-hour infarction. MATERIALS AND METHODS: Seventy-two patients had admission NCCT, multiphase CTA, CTP, and 24-hour DWI. All patients had successful/quality reperfusion. Patient-level and cohort-level receiver operator characteristic curves were generated to determine accuracy. A 10-fold cross-validation was performed on the cohort-level data. Infarct core volume was compared for SPIRAL, CTP-time-to-maximum, and final DWI by Bland-Altman analysis. RESULTS: When we compared the accuracy in patients with early and late reperfusion for cortical GM and WM, there was no significant difference at the patient level (0.83 versus 0.84, respectively), cohort level (0.82 versus 0.81, respectively), or the cross-validation (0.77 versus 0.74, respectively). In the patient-level receiver operating characteristic analysis, the SPIRAL map had a slightly higher, though nonsignificant (P < .05), average receiver operating characteristic area under the curve (cortical GM/WM, r = 0.82; basal ganglia = 0.79, respectively) than both the CTP-time-to-maximum (cortical GM/WM = 0.82; basal ganglia = 0.78, respectively) and CTP-CBF (cortical GM/WM = 0.74; basal ganglia = 0.78, respectively) parameter maps. The same relationship was observed at the cohort level. The Bland-Altman plot limits of agreement for SPIRAL and time-to-maximum infarct volume were similar compared with 24-hour DWI. CONCLUSIONS: We have shown that perfusion maps generated from a temporally sampled helical CTA are an accurate surrogate for infarct core.


Asunto(s)
Algoritmos , Angiografía Cerebral/métodos , Infarto Cerebral/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neuroimagen/métodos , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión/métodos , Curva ROC , Tomografía Computarizada por Rayos X
3.
AJNR Am J Neuroradiol ; 41(6): 1037-1042, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32467183

RESUMEN

BACKGROUND AND PURPOSE: The Neuroform Atlas is a new microstent to assist coil embolization of intracranial aneurysms that recently gained FDA approval. We present a postmarket multicenter analysis of the Neuroform Atlas stent. MATERIALS AND METHODS: On the basis of retrospective chart review from 11 academic centers, we analyzed patients treated with the Neuroform Atlas after FDA exemption from January 2018 to June 2019. Clinical and radiologic parameters included patient demographics, aneurysm characteristics, stent parameters, complications, and outcomes at discharge and last follow-up. RESULTS: Overall, 128 aneurysms in 128 patients (median age, 62 years) were treated with 138 stents. Risk factors included smoking (59.4%), multiple aneurysms (27.3%), and family history of aneurysms (16.4%). Most patients were treated electively (93.7%), and 8 (6.3%) underwent treatment within 2 weeks of subarachnoid hemorrhage. Previous aneurysm treatment failure was present in 21% of cases. Wide-neck aneurysms (80.5%), small aneurysm size (<7 mm, 76.6%), and bifurcation aneurysm location (basilar apex, 28.9%; anterior communicating artery, 27.3%; and middle cerebral artery bifurcation, 12.5%) were common. A single stent was used in 92.2% of cases, and a single catheter for both stent placement and coiling was used in 59.4% of cases. Technical complications during stent deployment occurred in 4.7% of cases; symptomatic thromboembolic stroke, in 2.3%; and symptomatic hemorrhage, in 0.8%. Favorable Raymond grades (Raymond-Roy occlusion classification) I and II were achieved in 82.9% at discharge and 89.5% at last follow-up. mRS ≤2 was determined in 96.9% of patients at last follow-up. The immediate Raymond-Roy occlusion classification grade correlated with aneurysm location (P < .0001) and rupture status during treatment (P = .03). CONCLUSIONS: This multicenter analysis provides a real-world safety and efficacy profile for the treatment of intracranial aneurysms with the Neuroform Atlas stent.


Asunto(s)
Prótesis Vascular , Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/terapia , Vigilancia de Productos Comercializados , Stents , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
4.
AJNR Am J Neuroradiol ; 40(1): 39-44, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30573458

RESUMEN

BACKGROUND AND PURPOSE: Thrombus characteristics identified on non-contrast CT (NCCT) are potentially associated with recanalization with intravenous (IV) alteplase in patients with acute ischemic stroke (AIS). Our aim was to determine the best radiomics-based features of thrombus on NCCT and CT angiography associated with recanalization with IV alteplase in AIS patients and proximal intracranial thrombi. MATERIALS AND METHODS: With a nested case-control design, 67 patients with ICA/M1 MCA segment thrombus treated with IV alteplase were included in this analysis. Three hundred twenty-six radiomics features were extracted from each thrombus on both NCCT and CTA images. Linear discriminative analysis was applied to select features most strongly associated with early recanalization with IV alteplase. These features were then used to train a linear support vector machine classifier. Ten times 5-fold cross-validation was used to evaluate the accuracy of the trained classifier and the stability of the selected features. RESULTS: Receiver operating characteristic curves showed that thrombus radiomics features are predictive of early recanalization with IV alteplase. The combination of radiomics features from NCCT, CTA, and radiomics changes is best associated with early recanalization with IV alteplase (area under the curve = 0.85) and was significantly better than any single feature such as thrombus length (P < .001), volume (P < .001), and permeability as measured by mean attenuation increase (P < .001), maximum attenuation in CTA (P < .001), maximum attenuation increase (P < .001), and assessment of residual flow grade (P < .001). CONCLUSIONS: Thrombus radiomics features derived from NCCT and CTA are more predictive of recanalization with IV alteplase in patients with acute ischemic stroke with proximal occlusion than previously known thrombus imaging features such as length, volume, and permeability.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Trombosis Intracraneal/diagnóstico por imagen , Neuroimagen/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Máquina de Vectores de Soporte , Anciano , Estudios de Casos y Controles , Angiografía por Tomografía Computarizada/métodos , Femenino , Humanos , Trombosis Intracraneal/tratamiento farmacológico , Trombosis Intracraneal/patología , Masculino , Persona de Mediana Edad , Curva ROC , Accidente Cerebrovascular/tratamiento farmacológico , Activador de Tejido Plasminógeno/uso terapéutico , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
5.
J Neurointerv Surg ; 10(Suppl 1): i9-i18, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30037946

RESUMEN

Endovascular, endosaccular, coil embolization has emerged as an established therapy for both ruptured and unruptured cerebral aneurysms. However, many aneurysms are not cured using conventional endovascular techniques. Coil embolization often results in incomplete aneurysm occlusion or recanalization in the ensuing months after treatment. The Pipeline embolization device (PED; Chestnut Medical) represents a new generation endoluminal implant which is designed to treat aneurysms by reconstructing the diseased parent artery. Immediately after implantation, the PED functions to divert flow from the aneurysm, creating an environment conducive to thrombosis. With time, the PED is incorporated into the vessel wall as neointimal-endothelial overgrowth occurs along the construct. Ultimately, this process results in the durable complete exclusion of the aneurysm from the cerebrovasculature and a definitive endoluminal reconstruction of the diseased parent artery.


Asunto(s)
Prótesis Vascular , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Adolescente , Anciano , Prótesis Vascular/tendencias , Ensayos Clínicos como Asunto/métodos , Embolización Terapéutica/tendencias , Procedimientos Endovasculares/tendencias , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
AJNR Am J Neuroradiol ; 38(4): 753-758, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28154128

RESUMEN

BACKGROUND AND PURPOSE: Use of statin medications has been demonstrated to improve clinical and angiographic outcomes in patients receiving endovascular stent placement for coronary, peripheral, carotid, and intracranial stenoses. We studied the impact of statin use on long-term angiographic and clinical outcomes after flow-diverter treatment of intracranial aneurysms. MATERIALS AND METHODS: We performed a post hoc analysis from pooled patient-level datasets from 3 Pipeline Embolization Device studies: the International Retrospective Study of the Pipeline Embolization Device, the Pipeline for Uncoilable or Failed Aneurysms Study, and the Aneurysm Study of Pipeline in an Observational Registry. We analyzed data comparing 2 subgroups: 1) patients on statin medication, and 2) patients not on statin medication at the time of the procedure and follow-up. Angiographic and clinical outcomes were compared by using the χ2 test, Fisher exact test, or Wilcoxon rank sum test. RESULTS: We studied 1092 patients with 1221 aneurysms. At baseline, 226 patients were on statin medications and 866 patients were not on statin medications. The mean length of clinical and angiographic follow-up was 22.1 ± 15.1 months and 28.3 ± 23.7 months, respectively. There were no differences observed in angiographic outcomes at any time point between groups. Rates of complete occlusion were 82.8% (24/29) versus 86.4% (70/81) at 1-year (P = .759) and 93.3% (14/15) versus 95.7% (45/47) at 5-year (P = 1.000) follow-up for statin-versus-nonstatin-use groups, respectively. There were no differences in any complication rates between groups, including major morbidity and neurologic mortality (7.5% versus 7.1%, P = .77). CONCLUSIONS: Our study found no association between statin use and angiographic or clinical outcomes among patients treated with the Pipeline Embolization Device.


Asunto(s)
Embolización Terapéutica/métodos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Anciano , Angiografía Cerebral , Embolización Terapéutica/mortalidad , Femenino , Humanos , Aneurisma Intracraneal/mortalidad , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Resultado del Tratamiento
7.
J Orthop ; 13(4): 294-7, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27408507

RESUMEN

Revision of a cemented femoral stem can be a challenging procedure. We present a series of cases utilising the "In-cement" revision, whereby the same size stem is introduced into the original cement mantle, without additional cementing. It requires a stable cement mantle in the correct version. We describe the technique and present a review of 23 revision total hip replacements performed over a 5 year period. At average follow-up of 67 months (12-128 months), the overall survivorship was 91.3% with no patient requiring re-revision for stem loosening or mechanical failure. Two patients required re-revision for infection and one of those patients is now deceased. No further operations were required in 21 patients. The "In-cement" revision can be a valuable technique for the revision arthroplasty surgeon. Early results suggest this is a safe and effective technique in the appropriate patient.

8.
AJNR Am J Neuroradiol ; 37(11): 2055-2059, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27390314

RESUMEN

BACKGROUND AND PURPOSE: Comparing outcomes between endovascular aneurysm coiling trials can be difficult because of heterogeneity in patients and end points. We sought to understand the impact of geography on aneurysm retreatment in patients enrolled in the Matrix and Platinum Science Trial. MATERIALS AND METHODS: Post hoc analysis was performed on data from the Matrix and Platinum Science trial. Patients were stratified as either North American or international. Baseline patient demographics, comorbidities, aneurysm characteristics, procedural complications, and clinical and angiographic outcomes were compared. RESULTS: We evaluated 407 patients from 28 North American sites and 219 patients from 15 international sites. Patient demographics differed significantly between North American and international sites. Aneurysms were well occluded postprocedure more often at international than North American sites (P < .001). Stents were used significantly more often at North American sites (32.7% [133 of 407]) compared with international sites (10.0% [22 of 219]; P < .001). At 455 days, there was no difference in the proportion of patients alive and free of disability (P = .56) or with residual aneurysm filling (P = .10). Ruptured aneurysms were significantly more likely to have been retreated at North American sites within the first year (P < .001) and at 2 years (P < .001). Among all patients for whom the treating physician believed there to be Raymond 3 aneurysm filling at follow-up, absolute rates of retreatment at international and North American sites were similar by 2-year follow-up. CONCLUSIONS: Data from the Matrix and Platinum Science Trial demonstrate that aneurysm retreatment occurs with different frequency and at different times in different regions of the world. This trend has critical value when interpreting trials reporting short-term outcomes, especially when judgment-based metrics such as retreatment are primary end points that may or may not take place within the defined study follow-up period. Though these variations can be controlled for and balanced within a given randomized trial, such differences in practice patterns must be accounted for in any attempt to compare outcomes between different trials. Despite these differences, endovascular-treated intracranial aneurysms around the world have similar clinical outcomes.

9.
AJNR Am J Neuroradiol ; 37(10): 1876-1882, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27197986

RESUMEN

BACKGROUND AND PURPOSE: Idiopathic intracranial hypertension has been associated with dural venous sinus stenosis in some patients, but the hemodynamic environment of the dural venous sinuses has not been quantitatively described. Here, we present the first such computational fluid dynamics model by using patient-specific blood pressure measurements. MATERIALS AND METHODS: Six patients with idiopathic intracranial hypertension and at least 1 stenosis or atresia at the transverse/sigmoid sinus junction underwent MR venography followed by cerebral venography and manometry throughout the dural venous sinuses. Patient-specific computational fluid dynamics models were created by using MR venography anatomy, with venous pressure measurements as boundary conditions. Blood flow and wall shear stress were calculated for each patient. RESULTS: Computational models of the dural venous sinuses were successfully reconstructed in all 6 patients with patient-specific boundary conditions. Three patients demonstrated a pathologic pressure gradient (≥8 mm Hg) across 4 dural venous sinus stenoses. Small sample size precludes statistical comparisons, but average overall flow throughout the dural venous sinuses of patients with pathologic pressure gradients was higher than in those without them (1041.00 ± 506.52 mL/min versus 358.00 ± 190.95 mL/min). Wall shear stress was also higher across stenoses in patients with pathologic pressure gradients (37.66 ± 48.39 Pa versus 7.02 ± 13.60 Pa). CONCLUSIONS: The hemodynamic environment of the dural venous sinuses can be computationally modeled by using patient-specific anatomy and physiologic measurements in patients with idiopathic intracranial hypertension. There was substantially higher blood flow and wall shear stress in patients with pathologic pressure gradients.

10.
AJNR Am J Neuroradiol ; 37(6): 1127-31, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26767709

RESUMEN

Flow diversion to treat cerebral aneurysms has revolutionized neurointerventional surgery. Because the addition of coils potentially increases the time and complexity of endovascular procedures, we sought to determine whether adjunctive coil use is associated with an increase in complications. Patients in the International Retrospective Study of Pipeline Embolization Device registry were divided into those treated with the Pipeline Embolization Device alone (n = 689 patients; n = 797 aneurysms; mean aneurysm size, 10.3 ± 7.6 mm) versus those treated with the Pipeline Embolization Device and concurrent coil embolization (n = 104 patients; n = 109 aneurysms; mean aneurysm size, 13.6 ± 7.8 mm). Patient demographics and aneurysm characteristics were examined. Rates of neurologic morbidity and mortality were compared between groups. The Pipeline Embolization Device with versus without coiling required a significantly longer procedure time (135.8 ± 63.9 versus 96.7 ± 46.2 min; P < .0001) and resulted in higher neurological morbidity (12.5% versus 7.8%; P = .13). These data suggest that either strategy represents an acceptable risk profile in the treatment of complex cerebral aneurysms and warrants further investigation.


Asunto(s)
Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Prótesis Vascular , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
11.
AJNR Am J Neuroradiol ; 37(3): 487-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26427829

RESUMEN

BACKGROUND AND PURPOSE: The rate of PICA occlusion after flow-diverting stent placement for vertebral and vertebrobasilar artery aneurysms is not known. The purpose of this study is to determine the medium-term rate of PICA patency and risk factors for occlusion after such aneurysm treatment. MATERIALS AND METHODS: Patients were identified who had vertebral or vertebrobasilar artery aneurysms and who were treated by placing a flow-diverting stent across the PICA ostium. Demographic and procedural factors associated with stent placement were recorded. Patency of the PICA was evaluated immediately after stent placement and on follow-up angiography. RESULTS: Thirteen patients with vertebral or vertebrobasilar artery aneurysms were treated in the study period, of whom 4 presented with subarachnoid hemorrhage. The average number of devices that spanned the PICA ostium was 1.77 (range, 1-3), with no immediate PICA occlusions. There were no postoperative strokes in the treated PICA territory, although there was 1 contralateral PICA-territory stroke of unclear etiology without clinical sequelae. In 11 patients with follow-up angiography at a mean of 10.6 months (range, 0.67-27.9 months), the PICA patency rate remained 100%. CONCLUSIONS: Flow-diverting stent placement across the PICA ostium in the treatment of vertebral and vertebrobasilar artery aneurysms may not result in immediate or midterm PICA occlusion.


Asunto(s)
Arterias Cerebrales/diagnóstico por imagen , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Adulto , Anciano , Anciano de 80 o más Años , Arteria Basilar/cirugía , Angiografía Cerebral , Arterias Cerebrales/cirugía , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Stents , Hemorragia Subaracnoidea/epidemiología , Grado de Desobstrucción Vascular , Arteria Vertebral/cirugía
12.
Child Care Health Dev ; 41(6): 1018-29, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25891293

RESUMEN

BACKGROUND: Clinicians working with youth with disabilities have acknowledged making friends as a commonly identified client goal. Clinicians find this goal difficult to address, as there are no measures that provide a breakdown of making friends into functional steps. In addition, research on friendship has traditionally focused on characteristics and quality of friendships rather than the friend-making process as a whole. A goal menu, comprised of a variety of steps that address the goal of making friends, would provide guidance to clinicians challenged with this goal in practice. PURPOSE: To develop an understanding of the friend-making process as a first step towards the development of a goal menu for the goal of making friends. METHODS: A literature review, youth focus group and expert clinician semi-structured interviews and consultation were used to generate a comprehensive data set. Established qualitative methods were used to sort and group the data into categories. A thematic analysis of the categories was performed. RESULTS: Analysis revealed four themes integral to the friend-making process: person factors influencing friend-making, making friend-making a priority, opportunity for friend-making and motivation to make friends. An additional theme identified as occasionally involved in the process was a little bit of luck in making friends. CONCLUSIONS: The themes generated by this research indicate that actionable target areas exist for the somewhat abstract notion of friend-making and the authors recommend that clinicians explore beyond person factors when addressing the goal of making friends. As a next step, the identified themes will provide the foundation for a goal menu, ultimately enabling clinicians to address the goal of making friends in a more efficient and effective manner.


Asunto(s)
Personas con Discapacidad/psicología , Amigos , Objetivos , Adolescente , Adulto , Femenino , Grupos Focales , Humanos , Masculino , Ontario
13.
AJNR Am J Neuroradiol ; 36(5): 930-6, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25593206

RESUMEN

BACKGROUND AND PURPOSE: The role of flow diversion in the management of aneurysms remains unknown. We sought to evaluate the community agreement regarding indications for flow diversion. MATERIALS AND METHODS: A portfolio of 35 difficult aneurysm cases was sent to 40 clinicians with varying backgrounds and experience. Responders were asked whether they considered flow diversion a treatment option, whether other options were possible, whether recruitment in a randomized trial would be considered, and to select their final choice. Agreement was studied by using κ statistics. RESULTS: Decisions for flow diversion were more frequent (n = 300, 39%) than decisions to coil (n = 163, 21.2%), to observe (n = 121, 15.7%), to occlude the parent vessel (n = 102, 13.2%), or to clip (n = 66, 8.6%). Sidewall aneurysm morphology was associated with flow diversion as the final choice (P = .001). Interjudge agreement was fair at best (κ <0.3) for all cases and all judges, despite high certainty levels (range, 7.2-8.9 ± 2.0 on a 0-10 scale). Agreement was no better within specialties or with more experience. All patients were judged to have other treatment options. Judges were willing to offer trial participation in 417 of 741 (56.3%) scenarios, more frequently when the aneurysm was sidewall (P = .001) or in the anterior circulation (P = .028). CONCLUSIONS: Individuals did not agree regarding the indications for flow diversion. There is sufficient uncertainty to justify trials designed to protect patients from the potential risks of premature adoption of an innovation.


Asunto(s)
Anastomosis Quirúrgica/métodos , Aneurisma Intracraneal/cirugía , Procedimientos Neuroquirúrgicos/métodos , Pautas de la Práctica en Medicina , Procedimientos Quirúrgicos Vasculares/métodos , Adulto , Anciano , Aneurisma/diagnóstico por imagen , Femenino , Humanos , Masculino , Radiografía , Incertidumbre
15.
AJNR Am J Neuroradiol ; 36(1): 108-15, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25355814

RESUMEN

BACKGROUND AND PURPOSE: Flow diverters are increasingly used in the endovascular treatment of intracranial aneurysms. Our aim was to determine neurologic complication rates following Pipeline Embolization Device placement for intracranial aneurysm treatment in a real-world setting. MATERIALS AND METHODS: We retrospectively evaluated all patients with intracranial aneurysms treated with the Pipeline Embolization Device between July 2008 and February 2013 in 17 centers worldwide. We defined 4 subgroups: internal carotid artery aneurysms of ≥10 mm, ICA aneurysms of <10 mm, other anterior circulation aneurysms, and posterior circulation aneurysms. Neurologic complications included spontaneous rupture, intracranial hemorrhage, ischemic stroke, permanent cranial neuropathy, and mortality. Comparisons were made with t tests or ANOVAs for continuous variables and the Pearson χ(2) or Fisher exact test for categoric variables. RESULTS: In total, 793 patients with 906 aneurysms were included. The neurologic morbidity and mortality rate was 8.4% (67/793), highest in the posterior circulation group (16.4%, 9/55) and lowest in the ICA <10-mm group (4.8%, 14/294) (P = .01). The spontaneous rupture rate was 0.6% (5/793). The intracranial hemorrhage rate was 2.4% (19/793). Ischemic stroke rates were 4.7% (37/793), highest in patients with posterior circulation aneurysms (7.3%, 4/55) and lowest in the ICA <10-mm group (2.7%, 8/294) (P = .16). Neurologic mortality was 3.8% (30/793), highest in the posterior circulation group (10.9%, 6/55) and lowest in the anterior circulation ICA <10-mm group (1.4%, 4/294) (P < .01). CONCLUSIONS: Aneurysm treatment with the Pipeline Embolization Device is associated with the lowest complication rates when used to treat small ICA aneurysms. Procedure-related morbidity and mortality are higher in the treatment of posterior circulation and giant aneurysms.


Asunto(s)
Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Anciano , Anciano de 80 o más Años , Embolización Terapéutica/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos
16.
Opt Lett ; 39(23): 6691-4, 2014 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-25490654

RESUMEN

Conical refraction occurs when a beam of light travels through an appropriately cut biaxial crystal. By focusing the conically refracted beam through a high numerical aperture microscope objective, conical refraction optical tweezers can be created, allowing for particle manipulation in both Raman spots, and in the Lloyd/Poggendorff rings. We present a thorough quantification of the trapping properties of such a beam, focusing on the trap stiffness, and how this varies with trap power and trapped particle location. We show that the lower Raman spot can be thought of as a single-beam optical gradient force trap, while radiation pressure dominates in the upper Raman spot, leading to optical levitation rather than trapping. Particles in the Lloyd/Poggendorff rings experience a lower trap stiffness than particles in the lower Raman spot, but benefit from rotational control.

17.
AJNR Am J Neuroradiol ; 35(5): 935-42, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24481333

RESUMEN

BACKGROUND AND PURPOSE: The ability of polymer-modified coils to promote stable aneurysm occlusion after endovascular treatment is not well-documented. Angiographic aneurysm recurrence is widely used as a surrogate for treatment failure, but studies documenting the correlation of angiographic recurrence with clinical failure are limited. This trial compares the effectiveness of Matrix(2) polyglycolic/polylactic acid biopolymer-modified coils with bare metal coils and correlates the angiographic findings with clinical failure (ie, target aneurysm recurrence), a composite end point that includes any incident of posttreatment aneurysm rupture, retreatment, or unexplained death. MATERIALS AND METHODS: This was a multicenter randomized noninferiority trial with blinded end point adjudication. We enrolled 626 patients, divided between Matrix(2) and bare metal coil groups. The primary outcome was target aneurysm recurrence at 12 ± 3 months. RESULTS: At 455 days, at least 1 target aneurysm recurrence event had occurred in 14.6% of patients treated with bare metal coils and 13.3% of Matrix(2) (P = .76, log-rank test) patients; 92.8% of target aneurysm recurrence events were re-interventions for aneurysms that had not bled after treatment, and 5.8% of target aneurysm recurrence events resulted from hemorrhage or rehemorrhage, with or without retreatment. Symptomatic re-intervention occurred in only 4 (0.6%) patients. At 455 days, 95.8% of patients with unruptured aneurysms and 90.4% of those with ruptured aneurysms were independent (mRS ≤ 2). Target aneurysm recurrence was associated with incomplete initial angiographic aneurysm obliteration, presentation with rupture, and a larger aneurysmal dome and neck size. CONCLUSIONS: Tested Matrix(2) coils were not inferior to bare metal coils. Endovascular coiling of intracranial aneurysms was safe, and the rate of technical success was high. Target aneurysm recurrence is a promising clinical outcome measure that correlates well with established angiographic measurements.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Embolización Terapéutica/instrumentación , Matriz Extracelular/química , Aneurisma Intracraneal/cirugía , Platino (Metal)/química , Stents/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Embolización Terapéutica/mortalidad , Análisis de Falla de Equipo , Femenino , Humanos , Incidencia , Internacionalidad , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/mortalidad , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Radiografía , Recurrencia , Factores de Riesgo , Método Simple Ciego , Tasa de Supervivencia , Resultado del Tratamiento , Adulto Joven
18.
AJNR Am J Neuroradiol ; 35(4): 698-705, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24184523

RESUMEN

BACKGROUND AND PURPOSE: Stent-assisted coiling may result in less aneurysm recanalization but more complications than coiling alone. We evaluated outcomes of coiling with and without stents in the multicenter Matrix and Platinum Science Trial. MATERIALS AND METHODS: All patients in the Matrix and Platinum Science Trial with unruptured intracranial aneurysms treated per protocol were included. Baseline patient and aneurysm characteristics, procedural details, neurologic outcomes, angiographic outcomes, and safety data were analyzed. RESULTS: Overall, 137 of 361 (38%) patients were treated with a stent. Stent-coiled aneurysms had wider necks (≥4 mm in 62% with stents versus 33% without, P < .0001) and lower dome-to-neck ratios (1.3 versus 1.8, P < .0001). Periprocedural serious adverse events occurred infrequently in those treated with and without stents (6.6% versus 4.5%, P = .39). At 1 year, total significant adverse events, mortality, and worsening of mRS were similar in treatment groups, but ischemic strokes were more common in stent-coiled patients than in coiled patients (8.8% versus 2.2%, P = .005). However, multivariate analysis confirmed that at 2 years after treatment, prior cerebrovascular accident (OR, 4.7; P = .0089) and aneurysm neck width ≥4 mm (OR, 4.5; P = .02) were the only independent predictors of ischemic stroke. Stent use was not an independent predictor of ischemic stroke at 2 years (OR, 1.1; P = .94). Stent use did not predict target aneurysm recurrence at 2 years, but aneurysm dome size ≥10 mm (OR, 9.94; P < .0001) did predict target aneurysm recurrence. CONCLUSIONS: Stent-coiling had similar outcomes as coiling despite stented aneurysms having more difficult morphology than coiled aneurysms. Increased ischemic events in stent-coiled aneurysms were attributable to baseline risk factors and aneurysm morphology.


Asunto(s)
Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Aneurisma Intracraneal/terapia , Stents/efectos adversos , Accidente Cerebrovascular/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/etiología , Angiografía Cerebral , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Análisis Multivariante , Platino (Metal) , Valor Predictivo de las Pruebas , Accidente Cerebrovascular/diagnóstico por imagen , Resultado del Tratamiento , Adulto Joven
20.
J Hosp Infect ; 84(1): 44-51, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23507051

RESUMEN

BACKGROUND: Short postoperative stays following caesarean section delivery make it difficult to assess accurately the risk of surgical site infection (SSI). Methods of case-finding that minimize variation are required to support effective surveillance systems, especially where used for benchmarking. AIM: To evaluate the efficacy of case-finding methods for SSI following caesarean delivery and their utility in establishing benchmark rates of SSI. METHODS: Hospitals conducted surveillance over one or two 13-week periods. Patients were reviewed during their inpatient stay, post partum by community midwives and via patient questionnaire at 30 days post delivery. To estimate the reliability of case-finding methods, case-note reviews were undertaken in a random sample of four hospitals. FINDINGS: A total of 404 SSIs were detected in 4107 caesarean deliveries from 14 hospitals. The median time to SSI was 10 days, 66% were detected in-hospital or by community midwives, and an additional 34% were patient-reported. The rate of SSI was 9.8% but the proportion of patients followed up varied significantly between centres. The estimated sensitivity and specificity of case-finding was 91.4% [95% confidence interval (CI): 53.4-98.4] and 98.6% (95% CI: 98.4-98.8), the positive predictive value 91.0% (95% CI: 82.4-96.1) and negative predictive value 98.6% (95% CI: 93.9-99.5). CONCLUSIONS: Combined case ascertainment methods are a feasible way to achieve active post-discharge surveillance and had high negative and positive predictive values. Additional SSIs can be detected by patient questionnaires but rates of SSI were strongly influenced by variation in intensity of both healthcare worker- and patient-based case-finding. This factor must be taken into account when comparing or benchmarking rates of SSI.


Asunto(s)
Cesárea , Infección Hospitalaria/epidemiología , Hospitales , Infección de la Herida Quirúrgica/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Alta del Paciente , Vigilancia de la Población , Embarazo , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...