Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Biomed Opt ; 13(1): 014027, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18315385

RESUMEN

We report on the development of a novel optical oxygen sensor for breath monitoring applications using the technique of phase fluorometry. The principal design criteria are that the system be compact, lightweight, and employ a disposable sensing element (while performing competitively with current commercial analyzers). The oxygen-sensitive, luminescent ruthenium complex Ru[dpp](3)(2+) is encapsulated in a sol-gel matrix and deposited onto a custom-designed, polymer sensor chip that provides significantly improved luminescence capture efficiency. The performance of the sensor module is characterized using a commercially available lung simulator. A resolution of 0.03% O(2) is achieved, which compares well with commercial breath monitoring systems and, when combined with its immunity to humidity and ability to respond effectively across a broad range of breathing rates, makes this device an extremely promising candidate for the development of a practical, low-cost biodiagnostic tool.


Asunto(s)
Pruebas Respiratorias/instrumentación , Mediciones Luminiscentes/instrumentación , Consumo de Oxígeno/fisiología , Oxígeno/análisis , Pruebas de Función Respiratoria/instrumentación , Transductores , Pruebas Respiratorias/métodos , Humanos , Mediciones Luminiscentes/métodos , Miniaturización , Reproducibilidad de los Resultados , Pruebas de Función Respiratoria/métodos , Sensibilidad y Especificidad
2.
Analyst ; 130(1): 41-5, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15614351

RESUMEN

This paper describes the development of a generic platform for enhanced, integrated optic sensors based on fluorescence detection. The platform employs a novel optical configuration in order to achieve enhanced performance and has inherent multianalyte detection capability. The sensor element comprises a multimode ridge waveguide that has been patterned with an analyte-sensitive fluorescent spot, which is excited directly using a LED. The platform was applied to the detection of gaseous oxygen as a proof of principle. The sol-gel-derived sensor spots were doped with an oxygen-sensitive fluorescent dichlororuthenium dye complex and intensity-based calibration data were generated from the oxygen-dependent waveguide output. The sensor achieved a LOD of 0.62% and a resolution of less than 0.96% gaseous oxygen, which compares favourably with a similar, recently reported system. This device highlights the combination of inexpensive rapid prototyping techniques and a dedicated sensor enhancement strategy that together facilitate the production of an effective prototype sensor platform.

3.
Analyst ; 127(11): 1478-83, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12475038

RESUMEN

An optical sensor for the measurement of carbon dioxide in Modified Atmosphere Packaging (MAP) applications has been developed. It is based on the fluorescent pH indicator 1-hydroxypyrene-3,6,8-trisulfonate (HPTS) immobilised in a hydrophobic organically modified silica (ormosil) matrix. Cetyltrimethylammonium hydroxide was used as an internal buffer system. Fluorescence is measured in the phase domain by means of the Dual Luminophore Referencing (DLR) sensing scheme which provides many of the advantages of lifetime-based fluorometric sensors and makes it compatible with established optical oxygen sensor technology. The long-term stability of the sensor membranes has been investigated. The sensor displays 13.5 degrees phase shift between 0 and 100% CO2 with a resolution of better than 1% and a limit of detection of 0.08%. Oxygen cross-sensitivity is minimised (0.6% quenching in air) by immobilising the reference luminophore in polymer nano-beads. Cross-sensitivity towards chloride and pH was found to be negligible. Temperature effects were studied, and a linear Arrhenius correlation between ln k and 1/T was found. The sensor is stable over a period of at least seven months and its output is in excellent agreement with a standard reference method for carbon dioxide analysis.


Asunto(s)
Dióxido de Carbono/análisis , Industria de Alimentos , Embalaje de Alimentos , Geles , Luminiscencia , Espectrometría de Fluorescencia/instrumentación , Espectrometría de Fluorescencia/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA