Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Audiol ; 57(sup1): S42-S50, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29256642

RESUMEN

OBJECTIVE: The objective of this study is to determine whether acoustic reflexes are pervasive (i.e. known with 95% confidence to be observed in at least 95% of people) by examining the frequency of occurrence using a friction-fit diagnostic middle ear analyser. DESIGN: Adult participants with very good hearing sensitivity underwent audiometric and middle ear testing. Acoustic reflexes were tested ipsilaterally and contralaterally in both ears across a range of elicitor frequencies. Reflex elicitors were 700 ms tones presented at maximum level of 100 dB HL. Two automated methods were used to detect the presence of an acoustic reflex. STUDY SAMPLE: A group of 285 adult volunteers with normal hearing. RESULTS: There were no conditions in which the proportion of participants exhibiting acoustic reflexes was high enough to be deemed pervasive. Ipsilateral reflexes were more likely to be observed than contralateral reflexes and reflexes were more common at 0.5 and 1 kHz elicitor frequencies as compared with 2 and 4 kHz elicitor frequencies. CONCLUSIONS: Acoustic reflexes are common among individuals with good hearing. However, acoustic reflexes are not pervasive and should not be included in damage risk criteria and health hazard assessments for impulsive noise.


Asunto(s)
Oído Medio/inervación , Pruebas Auditivas/métodos , Audición , Reflejo Acústico , Estimulación Acústica , Adolescente , Adulto , Anciano , Audiometría de Tonos Puros , Umbral Auditivo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas Nutricionales , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Adulto Joven
2.
Int J Audiol ; 54 Suppl 1: S19-29, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25549164

RESUMEN

OBJECTIVE: This study examined differences in thresholds obtained under Sennheiser HDA200 circumaural earphones using pure tone, equivalent rectangular noise bands, and 1/3 octave noise bands relative to thresholds obtained using Telephonics TDH-39P supra-aural earphones. DESIGN: Thresholds were obtained via each transducer and stimulus condition six times within a 10-day period. STUDY SAMPLE: Forty-nine adults were selected from a prior study to represent low, moderate, and high threshold reliability. RESULTS: The results suggested that (1) only small adjustments were needed to reach equivalent TDH-39P thresholds, (2) pure-tone thresholds obtained with HDA200 circumaural earphones had reliability equal to or better than those obtained using TDH-39P earphones, (3) the reliability of noise-band thresholds improved with broader stimulus bandwidth and was either equal to or better than pure-tone thresholds, and (4) frequency-specificity declined with stimulus bandwidths greater than one equivalent rectangular band, which could complicate early detection of hearing changes that occur within a narrow frequency range. CONCLUSIONS: These data suggest that circumaural earphones such as the HDA200 headphones provide better reliability for audiometric testing as compared to the TDH-39P earphones. These data support the use of noise bands, preferably ERB noises, as stimuli for audiometric monitoring.


Asunto(s)
Audiometría de Tonos Puros/instrumentación , Umbral Auditivo , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
3.
Int J Audiol ; 53 Suppl 2: S5-15, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24564693

RESUMEN

OBJECTIVE: To estimate the short-term variability and correlates of variability in pure-tone thresholds obtained using audiometric equipment designed for occupational use, and to examine the justification for excluding 8 kHz as a mandatory threshold in occupational hearing conservation programs. METHOD: Pure-tone thresholds and other hearing-related tests (e.g. noise dosimetry, otoscopy, middle-ear assessment) were conducted with a group of 527 adults between 20 and 69 years of age. Five measurement visits were completed by participants within 14 days. RESULTS: The 50% critical difference boundaries were - 5 and 0 dB at 4 kHz and below and - 5 and 5 dB at 6 and 8 kHz. The likelihood of spurious notches due to test-retest variability was substantially lower than the likelihood of failing to detect a notched configuration when present. Correlates of variability included stimulus frequency, baseline threshold, acoustic reflectance of the ear, average noise exposure during the previous eight hours, age, and the tester's level of education in audiology. CONCLUSION: The short-term variability in 8-kHz pure-tone thresholds obtained with the TDH-39P earphone was slightly greater than at other frequencies, but this difference was not large enough to justify the disadvantages stemming from the inability to detect a 6-kHz notch.


Asunto(s)
Audiometría de Tonos Puros/instrumentación , Umbral Auditivo , Pérdida Auditiva Provocada por Ruido/diagnóstico , Ruido/efectos adversos , Enfermedades Profesionales/diagnóstico , Exposición Profesional/efectos adversos , Adulto , Anciano , Diseño de Equipo , Femenino , Pérdida Auditiva Provocada por Ruido/etiología , Humanos , Masculino , Persona de Mediana Edad , Enfermedades Profesionales/etiología , Salud Laboral , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA