Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Gastroenterol ; 47(10): e96-100, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23933803

RESUMEN

BACKGROUND AND AIMS: Limited data are available regarding fully covered metal stents in the management of malignant distal biliary strictures. The aim of this study was to evaluate the safety of a fully covered self-expanding metal stent (FCSEMS) with flared ends, in treating malignant biliary strictures. We report our long-term retrospective analysis from 6 centers. METHODS: A total of 260 patients (142 males, median age 68 y) underwent endoscopic retrograde cholangiopancreatography with placement of FCSEMS (WallFlex; Boston Scientific, Natick, MA) for the palliation of obstructive jaundice in the setting of pancreatic adenocarcinoma (169), metastatic disease (36), cholangiocarcinoma (23), ampullary cancer (19), or other (13). Patients were evaluated clinically in follow-up and biochemical tests of liver function were obtained. Data were recorded for the following variables: patient survival, duration of stent patency, the need for subsequent biliary intervention, and complications. RESULTS: A total of 266 FCSEMS were placed in 260 patients. There was a median survival of 100 days (range, 7 to 531 d). There was a mean follow-up of 134±118 days (range, 4 to 519 d). Biliary decompression was successful in 252 patients (97%). At the end of the study period, 121 were alive with a patent stent, 65 patients died with a patent stent, 40 patients were successfully bridged to surgery, 8 patients had their patent stent removed and had no need for further stenting, and 18 patients were lost to follow-up. Five patients who had a successfully placed FCSEMS were considered a failure due to the following reason: migration (2), cholangitis (1), stent occlusion (1), and removal for management of proximal biliary obstruction (1). Two additional patients experienced migration that did not require FCSEMS removal or replacement. Stent replacement was required in 10 patients, of whom 6 had a second FCSEMS placed. The remaining 4 were in the failure group and underwent replacement with either uncovered stents or plastic stents. Other complications, managed conservatively, included pain (2), postendoscopic retrograde cholangiopancreatography pancreatitis (4), fever (1), retroperitoneal perforation (1), and postsphincterotomy bleeding (1). The mean patency duration was 328 days (SE 19.04). The patency percentage was 83% at 3 months, 63% at 6 months, and 48.5% at 12 months. CONCLUSIONS: In the management of malignant distal biliary strictures, the fully covered WallFlex stent has acceptable patency and complication rates. Further long-term prospective data are required to confirm this observation.


Asunto(s)
Neoplasias de los Conductos Biliares/complicaciones , Colestasis/terapia , Ictericia Obstructiva/terapia , Stents , Anciano , Neoplasias de los Conductos Biliares/patología , Colangiopancreatografia Retrógrada Endoscópica/métodos , Colestasis/etiología , Colestasis/patología , Remoción de Dispositivos , Femenino , Estudios de Seguimiento , Humanos , Ictericia Obstructiva/etiología , Pruebas de Función Hepática , Masculino , Metales , Cuidados Paliativos/métodos , Estudios Retrospectivos , Stents/efectos adversos , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
2.
J Clin Gastroenterol ; 47(8): 695-9, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23442836

RESUMEN

BACKGROUND: Covered self-expanding metal stents are being used more frequently in benign biliary strictures (BBS). We report the results of a multicenter study with fully covered self-expanding metal stent (FCSEMS) placement for the management of BBS. AIM: : To prospectively evaluate the efficacy and safety of FCSEMS in the management of BBS. PATIENTS AND METHODS: Patients with BBS from 6 tertiary care centers who received FCSEMS with flared ends between April 2009 and October 2010 were included in this retrospective study.Efficacy was measured after removal of FCSEMS by evaluating stricture resolution on the basis of symptom resolution, imaging, laboratory studies, and/or choledochoscopy at removal. Safety profile was evaluated by assessing postprocedural complications. RESULTS: A total of 133 patients (78, 58.6% males) with a mean age of 59.2±14.8 years with BBS received stents. Of the 133 stents placed, 97 (72.9%) were removed after a mean stent duration of 95.5±48.7 days. Stricture resolution after FCSEMS removal was as follows: postsurgical, 11/12 (91.6%); gallstone-related disease, 16/19 (84.2%); chronic pancreatitis, 26/31 (80.7%); other etiology, 4/5 (80.0%); and anastomotic strictures, 19/31(61.2%). Ninety-four patients were included in the logistic regression analyses. Patients who had indwelling stents for >90 days were 4.3 times more likely to have resolved strictures [odds ratio, 4.3 (95% confidence interval, 1.24-15.09)] and patients with nonmigrated stents were 5.4 times more likely to have resolved strictures [odds ratio, 5.4 (95% confidence interval, 1.001-29.29)]. CONCLUSIONS: FCSEMS for BBS had an acceptable rate of stricture resolution for postsurgical strictures, gallstone-related strictures, and those due to chronic pancreatitis. Predictors for stricture resolution include longer indwell time and absence of migration. Further study is warranted to assess long-term efficacy in a prospective manner with longer than 3-month time of stent indwelling time.


Asunto(s)
Enfermedades de las Vías Biliares/terapia , Stents , Adulto , Anciano , Enfermedades de las Vías Biliares/patología , Constricción Patológica/patología , Constricción Patológica/terapia , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA