Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
ERJ Open Res ; 8(2)2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35539438

RESUMEN

Aim: The aim of this study was to evaluate the acute effects of different inspiratory resistance devices and intensity of loads via nasal airway on the breathing pattern and activity of respiratory muscles in children with mouth breathing syndrome (MBS). Methods: Children with MBS were randomised into two groups based on inspiratory load intensity (20% and 40% of the maximal inspiratory pressure). These subjects were assessed during quiet breathing, breathing against inspiratory load via nasal airway and recovery. The measurements were repeated using two different devices (pressure threshold and flow resistance). Chest wall volumes and respiratory muscle activity were evaluated by optoelectronic plethysmography and surface electromyography, respectively. Results: During the application of inspiratory load, there was a significant reduction in respiratory rate (p<0.04) and an increase in inspiratory time (p<0.02), total time of respiratory cycle (p<0.02), minute ventilation (p<0.03), tidal volume (p<0.01) and scalene and sternocleidomastoid muscles activity (root mean square values, p<0.01) when compared to quiet spontaneous breathing and recovery, regardless of load level or device applied. The application of inspiratory load using the flow resistance device showed an increase in the tidal volume (p<0.02) and end-inspiratory volume (p<0.02). Conclusion: For both devices, the addition of inspiratory loads using a nasal interface had a positive effect on the breathing pattern. However, the flow resistance device was more effective in generating volume and, therefore, has advantages compared to pressure threshold.

2.
PLoS One ; 16(7): e0253132, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34292943

RESUMEN

BACKGROUND: We investigated the influence of diaphragmatic activation control (diaphC) on the relaxation rate, contractile properties and electrical activity of the inspiratory muscles of healthy subjects. Assessments were performed non-invasively using the sniff inspiratory pressure test (SNIP) and surface electromyography, respectively. METHODS: Twenty-two subjects (10 men and 12 women) performed 10 sniff maneuvers in two different days: with and without diaphC instructions. For the SNIP test with diaphC, the subjects were instructed to perform intense activation of the diaphragm. The tests with the best SNIP values were used for analysis. RESULTS: The maneuver with diaphC when compared to the maneuver without diaphC exhibited significant lower values for: SNIP (p <0.01), maximum relaxation rate (MRR) (p <0.01), maximum rate of pressure development (MRPD) (p <0.01), contraction times (CT) (p = 0.02) and electrical activity of the sternocleidomastoid (SCM) (p <0.01), scalene (SCL) (p = 0.01) and intercostal (CI) (p = 0.03) muscles. In addition, the decay constant (tau, τ) and relaxation time (½ RT) did not present any changes. CONCLUSION: The diaphragmatic control performed during the SNIP test influences the inspiratory pressure and the contractile properties of inspiratory muscles. This occurs due to changes in the pattern of muscle recruitment, which change force velocity characteristics of the test. Thus, instruction on diaphC should be encouraged for better performance of the SNIP test and for evaluation targeting the diaphragm muscle activity.


Asunto(s)
Diafragma/fisiología , Inhalación/fisiología , Presiones Respiratorias Máximas , Adolescente , Adulto , Electromiografía , Femenino , Humanos , Masculino , Nariz , Adulto Joven
3.
Respir Care ; 65(11): 1668-1677, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32546537

RESUMEN

BACKGROUND: Advanced stages of Duchenne muscular dystrophy (DMD) result in muscle weakness and the inability to generate an effective cough. Several factors influence the effectiveness of cough in patients with DMD. The aim of this study was to assess whether differences in positioning affect cough peak flow (CPF) and muscular electromyographic activation in subjects with DMD compared with paired healthy subjects. METHODS: Optoelectronic plethysmography and surface electromyography were used to assess chest wall volumes, chest wall inspiratory capacity, CPF, breathing pattern, and electromyographic activity of sternocleidomastoid, scalene, rectus abdominis, and external oblique muscles during inspiratory and expiratory cough phases in the supine position, supine position with headrest raised at 45°, and sitting with back support at 80° in 12 subjects with DMD and 12 healthy subjects. RESULTS: Subjects with DMD had lower CPF (P < .01) in comparison to control subjects in all positions; the DMD group also exhibited lower CPF (P = .045) in the supine position versus 80°. Moreover, the relative volume contributions of the rib cage and abdominal compartments to tidal volume modified significantly with posture. The electromyographic activity during inspiratory and expiratory cough phases was lower in subjects with DMD compared to healthy subjects for all evaluated muscles (P < .05), but no significant differences were observed with posture change. CONCLUSIONS: In subjects with DMD, posture influenced CPF and the relative contribution of the rib cage and abdominal compartments to tidal volume. However, muscular electromyographic activation was not influenced by posture in subjects with DMD and healthy subjects.


Asunto(s)
Tos/etiología , Distrofia Muscular de Duchenne , Humanos , Ápice del Flujo Espiratorio , Pletismografía , Músculos Respiratorios , Volumen de Ventilación Pulmonar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA