Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Cardiovasc Digit Health J ; 4(6): 173-182, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38222102

RESUMEN

Background: Cerebral thromboembolism during atrial fibrillation (AF) ablation is an infrequent (0.17%) complication in part owing to strict adherence to intraprocedural anticoagulation. Failure to maintain therapeutic anticoagulation can lead to an increase in events, including silent cerebral ischemia. Objective: To evaluate a computerized, clinical decision support system (CDSS) to dose intraprocedural anticoagulation and determine if it leads to improved intraprocedural anticoagulation outcomes during AF ablation. Methods: The Digital Intern dosing algorithm is an adaptive, rule-based CDSS for heparin dosing. The initial dose is calculated from the patient's weight, baseline activated clotting time (ACT), and outpatient anticoagulant. Subsequent recommendations adapt based on individual patient ACT changes. Outcomes from 50 cases prior to algorithm introduction were compared to 139 cases using the algorithm. Results: Procedures using the dosing algorithm reached goal ACT (over 300 seconds) faster (17.6 ± 11.1 minutes vs 33.3 ± 23.6 minutes pre-algorithm, P < .001). ACTs fell below goal while in the LA (odds ratio 0.20 [0.10-0.39], P < .001) and rose above 400 seconds less frequently (odds ratio 0.21 [0.07-0.59], P = .003). System Usability Scale scores were excellent (96 ± 5, n = 7, score >80.3 excellent). Preprocedure anticoagulant, weight, baseline ACT, age, sex, and renal function were potential predictors of heparin dose to achieve ACT >300 seconds and final infusion rate. Conclusion: A heparin dosing CDSS based on rules and adaptation to individual patient response improved maintenance of therapeutic ACT during AF ablation and was rated highly by nurses for usability.

2.
JMIR Hum Factors ; 9(4): e38411, 2022 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-36315238

RESUMEN

BACKGROUND: According to the US Food and Drug Administration Center for Biologics Evaluation and Research, health care systems have been experiencing blood transfusion overuse. To minimize the overuse of blood product transfusions, a proprietary artificial intelligence (AI)-based blood utilization calculator (BUC) was developed and integrated into a US hospital's electronic health record. Despite the promising performance of the BUC, this technology remains underused in the clinical setting. OBJECTIVE: This study aims to explore how clinicians perceived this AI-based decision support system and, consequently, understand the factors hindering BUC use. METHODS: We interviewed 10 clinicians (BUC users) until the data saturation point was reached. The interviews were conducted over a web-based platform and were recorded. The audiovisual recordings were then anonymously transcribed verbatim. We used an inductive-deductive thematic analysis to analyze the transcripts, which involved applying predetermined themes to the data (deductive) and consecutively identifying new themes as they emerged in the data (inductive). RESULTS: We identified the following two themes: (1) workload and usability and (2) clinical decision-making. Clinicians acknowledged the ease of use and usefulness of the BUC for the general inpatient population. The clinicians also found the BUC to be useful in making decisions related to blood transfusion. However, some clinicians found the technology to be confusing due to inconsistent automation across different blood work processes. CONCLUSIONS: This study highlights that analytical efficacy alone does not ensure technology use or acceptance. The overall system's design, user perception, and users' knowledge of the technology are equally important and necessary (limitations, functionality, purpose, and scope). Therefore, the effective integration of AI-based decision support systems, such as the BUC, mandates multidisciplinary engagement, ensuring the adequate initial and recurrent training of AI users while maintaining high analytical efficacy and validity. As a final takeaway, the design of AI systems that are made to perform specific tasks must be self-explanatory, so that the users can easily understand how and when to use the technology. Using any technology on a population for whom it was not initially designed will hinder user perception and the technology's use.

3.
J Emerg Med ; 63(1): 17-48, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35918220

RESUMEN

BACKGROUND: Reversal of antithrombotic agents and treatment of life-threatening bleeding episodes from coagulopathies can be a stressful scenario for clinicians, especially when the selection of treatment options should occur quickly. Understanding the options available for these agents requires emergency physicians to be familiar with the current data surrounding new therapies and dosing strategies for the treatment of bleeding from reversible and nonreversible antithrombotics and coagulopathic conditions. OBJECTIVE: To provide quick resource guides for the reversal of major or life-threatening bleeding caused by antithrombotic agents or in the setting of coagulopathies. METHODS: A literature search for articles published through September 2021 related to antithrombotic reversal and treatment of acute bleeding from coagulopathies was conducted using the PubMed clinical database. Selected articles were used to generate 5 guidance tables in this clinical review. DISCUSSION: Four guidance tables for how to treat major or life-threatening bleeding from antithrombotic agents and 1 table for how to manage life-threatening bleeding for coagulopathies are presented as a quick reference tool for the emergency physician. Additional information on upcoming reversal agents and possible treatment options are provided herein. CONCLUSIONS: In this clinical review, a series of 5 tables were created to provide quick and comprehensive guidance for the emergency physician when treating major or life-threatening bleeding caused by antithrombotic agents or coagulopathies. © 2022 Elsevier Inc.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Fibrinolíticos , Anticoagulantes/uso terapéutico , Trastornos de la Coagulación Sanguínea/tratamiento farmacológico , Fibrinolíticos/efectos adversos , Hemorragia/tratamiento farmacológico , Humanos
4.
Appl Ergon ; 101: 103708, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35149301

RESUMEN

A gap exists between the capabilities of artificial intelligence (AI) technologies in healthcare and the extent to which clinicians are willing to adopt these systems. Our study addressed this gap by leveraging 'expectancy-value theory' and 'modified extended unified theory of acceptance and use of technology' to understand why clinicians may be willing or unwilling to adopt AI systems. The study looked at the 'expectancy,' 'trust,' and 'perceptions' of clinicians related to their intention of using an AI-based decision support system known as the Blood Utilization Calculator (BUC). The study used purposive sampling to recruit BUC users and administered a validated online survey from a large hospital system in the Midwest in 2021. The findings captured the significant effect of 'perceived risk' (negatively) and 'expectancy' (positively) on clinicians' 'trust' in BUC. 'Trust' was also found to mediate the relationship of 'perceived risk' and 'expectancy' with the 'intent to use BUC.' The study's findings established pathways for future research and have implications on factors influencing BUC use.


Asunto(s)
Inteligencia Artificial , Confianza , Atención a la Salud , Humanos , Intención , Tecnología
5.
Neurosurgery ; 89(6): 1141-1147, 2021 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-34528096

RESUMEN

BACKGROUND: There have been few improvements in cerebrospinal fluid (CSF) shunt technology since John Holter introduced the silicon valve, with overdrainage remaining a major source of complications. OBJECTIVE: To better understand why valves are afflicted by supra-normal CSF flow rates. We present in Vitro benchtop analyses of flow through a differential pressure valve under simulated physiological conditions. METHODS: The pseudo-ventricle benchtop valve testing platform that comprises a rigid pseudo-ventricle, compliance chamber, pulsation generator, and pressure sensors was used to measure flow rates through a differential pressure shunt valve under the following simulated physiological conditions: orientation (horizontal/vertical), compliance (low/medium/high), and pulsation generator force (low/medium/high). RESULTS: Our data show that pulse pressures are faithfully transmitted from the ventricle to the valve, that lower compliance and higher pulse generator forces lead to higher pulse pressures in the pseudo-ventricle, and that both gravity and higher pulse pressure lead to higher flow rates. The presence of a valve mitigates but does not eliminate these higher flow rates. CONCLUSION: Shunt valves are prone to gravity-dependent overdrainage, which has motivated the development of gravitational valves and antisiphon devices. This study shows that overdrainage is not limited to the vertical position but that pulse pressures that simulate rhythmic (eg, cardiac) and provoked (eg, Valsalva) physiological CSF pulsations increase outflow in both the horizontal and vertical positions and are dependent on compliance. A deeper understanding of the physiological parameters that affect intracranial pressure and flow through shunt systems is prerequisite to the development of novel valves.


Asunto(s)
Hidrocefalia , Derivación Ventriculoperitoneal , Presión del Líquido Cefalorraquídeo , Derivaciones del Líquido Cefalorraquídeo/efectos adversos , Drenaje/efectos adversos , Diseño de Equipo , Humanos , Hidrocefalia/cirugía , Presión Intracraneal , Derivación Ventriculoperitoneal/efectos adversos
6.
Transfusion ; 60(9): 1970-1976, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32701187

RESUMEN

BACKGROUND: The use of electronic clinical decision support (CDS) is becoming common to change historically common clinical practices considered outdated by current guidelines. Preimplementation design of CDS tools is key to their success in changing clinical behaviors. Unfortunately, there are no established protocols for CDS tool development, and CDS failure can result from even small design flaws. This paper describes an example of a design oversight and how correction resulted in CDS success. STUDY DESIGN AND METHODS: We performed a retrospective review of compliance with a CDS tool to encourage the use of prothrombin complex concentrate over plasma transfusion for the emergent reversal of warfarin. We identified a potential design flaw, made the necessary modifications, and repeated the compliance review. RESULTS: After CDS, plasma orders declined by 150 units/mo; however, 48% of orders placed for non-warfarin coagulopathy were still for warfarin reversal. Hospital-wide, this noncompliance was 36% and was 80% in the emergency department. By simply relocating the qualifier "NOT on warfarin" from the end to the beginning of the order, noncompliance for warfarin reversal was reduced to 5% (P < .0001 by chi-square). CONCLUSIONS: The successful use of electronic clinical decision support in the electronic medical record can depend on optimal design. Missing even small design elements such as the positioning of key terms within the tool can result in an ineffective CDS. Important design strategies to avoid poor performance are discussed as they relate to the CDS tool we describe.


Asunto(s)
Factores de Coagulación Sanguínea/administración & dosificación , Transfusión de Componentes Sanguíneos , Sistemas de Apoyo a Decisiones Clínicas , Plasma , Humanos , Estudios Retrospectivos , Warfarina/administración & dosificación , Warfarina/efectos adversos
7.
Neurocrit Care ; 31(1): 229, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31119686

RESUMEN

The authors note that there is a discrepancy between the text of the paper and Table 2 regarding physician subspecialty certification requirements in neurocritical care for Level II centers.

8.
Artículo en Inglés | MEDLINE | ID: mdl-30440275

RESUMEN

Hydrocephalus is a neurological condition that can result from trauma, hemorrhage, cancer, and infection. To control the intracranial pressure (ICP) a shunt is implanted to drain the cerebro-spinal fluid (CSF). We are working to develop an implantable pressure sensor. When the ICP is too high it will open a valve to relieve the ICP. When the ICP is too low, it will close the valve.


Asunto(s)
Hidrocefalia/fisiopatología , Presión Intracraneal , Catéteres , Derivaciones del Líquido Cefalorraquídeo , Drenaje , Humanos , Hidrocefalia/terapia , Prótesis e Implantes
9.
Neurocrit Care ; 29(2): 145-160, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30251072

RESUMEN

Neurocritical care is a distinct subspecialty focusing on the optimal management of acutely ill patients with life-threatening neurologic and neurosurgical disease or with life-threatening neurologic manifestations of systemic disease. Care by expert healthcare providers to optimize neurologic recovery is necessary. Given the lack of an organizational framework and criteria for the development and maintenance of neurological critical care units (NCCUs), this document is put forth by the Neurocritical Care Society (NCS). Recommended organizational structure, personnel and processes necessary to develop a successful neurocritical care program are outlined. Methods: Under the direction of NCS Executive Leadership, a multidisciplinary writing group of NCS members was formed. After an iterative process, a framework was proposed and approved by members of the writing group. A draft was then written, which was reviewed by the NCS Quality Committee and NCS Guidelines Committee, members at large, and posted for public comment. Feedback was formally collated, reviewed and incorporated into the final document which was subsequently approved by the NCS Board of Directors.


Asunto(s)
Cuidados Críticos/normas , Enfermedades del Sistema Nervioso/terapia , Neurología/normas , Personal de Hospital/normas , Guías de Práctica Clínica como Asunto/normas , Mejoramiento de la Calidad/normas , Sociedades Médicas/normas , Humanos
11.
Transfusion ; 58(7): 1689-1696, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29717482

RESUMEN

BACKGROUND: Electronic decision support has been used to reduce use of red blood cell (RBC) transfusion. With the goal of reducing transfusions, we modified our RBC orders to default to 1 unit. Next, we created a target-based algorithm, the blood utilization calculator or BUC, to calculate a dose in units, based on initial hemoglobin or hematocrit and weight. STUDY DESIGN AND METHODS: RBC orders defaulted to 1 unit in March 2016 and the BUC was implemented in July 2016. This gave three periods to compare old orders (before intervention), new orders (1-unit default), and the BUC period. A hospital dashboard that tracks blood product orders was queried to determine changes in single-unit transfusions between periods. Changes in transfusions were compared by analysis of variance. Acceptance of the BUC dosage recommendation was studied in both medical-based and surgical-based specialties. RESULTS: The number of single-unit transfusions showed significant increases after each of the two interventions studied from 247 ± 19 before interventions to 358 ± 19 and then to 445 ± 141-unit transfusions/month (p < 0.0001). The ratio of 1-unit to 2-unit transfusions increased from 0.72 to 1.67 (p < 0.0001) and we observed a 19% overall reduction in units transfused. The BUC recommendation was accepted in 49% of orders. CONCLUSIONS: One-unit default orders and implementation of the BUC resulted in a significant increase in the use of single-unit transfusions. Improvement in the rate of acceptance of the BUC recommendation should further increase the use of single-unit transfusions.


Asunto(s)
Transfusión Sanguínea/estadística & datos numéricos , Transfusión de Eritrocitos/estadística & datos numéricos , Centros Médicos Académicos/estadística & datos numéricos , Algoritmos , Humanos
12.
Transfusion ; 58(2): 366-371, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29194652

RESUMEN

BACKGROUND: The Digital Intern (DI) is an electronic decision support tool for the management of organ donors. One algorithm determines the dose, in units of red blood cells to be transfused, based on hematocrit (Hct) thresholds and targets. The effectiveness of the transfusion dose calculated by the DI in terms of achieving the selected Hct target and the duration of the targeted dose is not known. STUDY DESIGN AND METHODS: This was a retrospective study to describe the outcomes of transfusions prescribed by the DI. Pre- and posttransfusion Hct levels were compared to define response and all posttransfusion Hct values were plotted to evaluate the duration of the prescribed dose. RESULTS: A total of 120 organ donors were studied and 22 donors had 28 transfusions (six were transfused twice). The transfused donors were a mix of trauma and medical admissions and brain death and cardiac death donors. The transfusion target of 24% Hct was attained in 96% of transfusions. The mean number of units transfused was 1.4 and the mean time from transfusion to procurement was 19.8 hours. There was a decline in Hct over time after transfusion in all but one case with a mean decline of 1.9% Hct over 13 hours. Six donors were transfused twice, likely due to a longer donor time period (41.7 hr vs. 27 hr). CONCLUSIONS: The DI provided transfusion dosing that achieved the desired threshold in the majority of organ donors transfused. Ongoing work focuses on application of this technology to transfusions in general patient populations.


Asunto(s)
Algoritmos , Toma de Decisiones Asistida por Computador , Transfusión de Eritrocitos , Donantes de Tejidos , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo
13.
Neurosurg Focus ; 43(5): E16, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29088947
15.
IEEE Trans Biomed Circuits Syst ; 11(5): 1123-1132, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28809712

RESUMEN

We present a wide frequency range, low cost, wireless intracranial pressure monitoring system, which includes an implantable passive sensor and an external reader. The passive sensor consists of two spiral coils and transduces the pressure change to a resonant frequency shift. The external portable reader reads out the sensor's resonant frequency over a wide frequency range (35 MHz-2.7 GHz). We propose a novel circuit topology, which tracks the system's impedance and phase change at a high frequency with low-cost components. This circuit is very simple and reliable. A prototype has been developed, and measurement results demonstrate that the device achieves a suitable measurement distance (>2 cm), sufficient sample frequency (>6 Hz), fine resolution, and good measurement accuracy for medical practice. Responsivity of this prototype is 0.92 MHz/mmHg and resolution is 0.028 mmHg. COMSOL specific absorption rate simulation proves that this system is safe. Considerations to improve the device performance have been discussed, which include the size of antenna, the power radiation, the Analog-to-digital converter (ADC) choice, and the signal processing algorithm.


Asunto(s)
Presión Intracraneal , Prótesis e Implantes , Tecnología Inalámbrica , Algoritmos , Conversión Analogo-Digital , Humanos , Procesamiento de Señales Asistido por Computador
16.
Physiol Meas ; 38(8): R143-R182, 2017 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-28489610

RESUMEN

Measurement of intracranial pressure (ICP) can be invaluable in the management of critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain ventricles (a set of communicating chambers), after which it circulates through the different ventricles and exits into the subarachnoid space around the brain, where it is reabsorbed into the venous system. If the fluid does not drain out of the brain or get reabsorbed, the ICP increases, which may lead to brain damage or death. ICP elevation accompanied by dilatation of the cerebral ventricles is termed hydrocephalus, whereas ICP elevation accompanied by normal or small ventricles is termed idiopathic intracranial hypertension. OBJECTIVE: We performed a comprehensive literature review on how to measure ICP invasively and noninvasively. APPROACH: This review discusses the advantages and disadvantages of current invasive and noninvasive approaches. MAIN RESULTS: Invasive methods remain the most accurate at measuring ICP, but they are prone to a variety of complications including infection, hemorrhage and neurological deficits. Ventricular catheters remain the gold standard but also carry the highest risk of complications, including difficult or incorrect placement. Direct telemetric intraparenchymal ICP monitoring devices are a good alternative. Noninvasive methods for measuring and evaluating ICP have been developed and classified in five broad categories, but have not been reliable enough to use on a routine basis. These methods include the fluid dynamic, ophthalmic, otic, and electrophysiologic methods, as well as magnetic resonance imaging, transcranial Doppler ultrasonography (TCD), cerebral blood flow velocity, near-infrared spectroscopy, transcranial time-of-flight, spontaneous venous pulsations, venous ophthalmodynamometry, optical coherence tomography of retina, optic nerve sheath diameter (ONSD) assessment, pupillometry constriction, sensing tympanic membrane displacement, analyzing otoacoustic emissions/acoustic measure, transcranial acoustic signals, visual-evoked potentials, electroencephalography, skull vibrations, brain tissue resonance and the jugular vein. SIGNIFICANCE: This review provides a current perspective of invasive and noninvasive ICP measurements, along with a sense of their relative strengths, drawbacks and areas for further improvement. At present, none of the noninvasive methods demonstrates sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use. However, they provide a realizable ICP measurement in specific patients especially when invasive monitoring is contraindicated or unavailable. Among all noninvasive ICP measurement methods, ONSD and TCD are attractive and may be useful in selected settings though they cannot be used as invasive ICP measurement substitutes. For a sufficiently accurate and universal continuous ICP monitoring method/device, future research and developments are needed to integrate further refinements of the existing methods, combine telemetric sensors and/or technologies, and validate large numbers of clinical studies on relevant patient populations.


Asunto(s)
Presión Intracraneal , Monitoreo Fisiológico/métodos , Animales , Humanos , Monitoreo Fisiológico/instrumentación
17.
Transfusion ; 57(6): 1369-1375, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28266049

RESUMEN

BACKGROUND: Prospective clinical trials support restrictive thresholds for red blood cell (RBC) transfusion. Nonsurvivable donors are a major source of organs for transplantation. The Digital Intern (DI) is a computer algorithm to standardize donor care that includes a more restrictive transfusion threshold. The impact of standardized and restrictive RBC transfusion in organ donors, as determined by the DI, has not been reported. STUDY DESIGN AND METHODS: We conducted a retrospective cohort study to compare the transfusion practice of the DI (n = 100) to a historic group of physician-managed donors (n = 90). Transfusion rates, the number of units transfused, and pretransfusion laboratory values were compared between groups. The variability of these parameters was also compared between groups. Finally, the number of transplanted organs per donor in each group was compared. RESULTS: The mean time as a donor was 25.9 ± 15.2 hours and was not different between the groups. In the DI group 19% were transfused compared to 26% in the control group (p = 0.3). The number of units transfused was less in the DI group (1 unit vs. 2 units per transfusion, p = 0.03) and the pretransfusion hematocrit was lower in the DI group (23% vs. 27%, p = 0.01). The variability in the latter two parameters was significantly lower in the DI group. The number of transplanted organs per donor was similar in both groups (3.24 [DI] vs. 3.03 [control], p = 0.37). CONCLUSION: The DI provides a more standardization transfusion practice in organ donors and reduces blood use without compromising transplantable organs.


Asunto(s)
Algoritmos , Transfusión de Eritrocitos , Humanos , Estudios Retrospectivos
18.
Clin Med Res ; 13(1): 20-31, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25380610

RESUMEN

It is imperative for neurologists, neurosurgeons, and neurointensivists to know how to stop life-threatening hemorrhage in both surgical and non-surgical patients. However, knowing how to medically correct a coagulopathy has become increasingly challenging as more contemporary and sophisticated anticoagulation agents are developed and prescribed. In a time-sensitive and life-threatening situation, where there is little margin for error, the neurosurgeon may not have ready access to information about the drug or condition that caused the coagulopathy or the information on how to treat it. This thorough review of the literature provides a comprehensive overview of the medications and conditions that can lead to persistent and/or life-threatening intracranial hemorrhage.


Asunto(s)
Coagulación Intravascular Diseminada/prevención & control , Hemorragias Intracraneales/prevención & control , Procedimientos Neuroquirúrgicos , Humanos
19.
Clin Med Res ; 13(2): 89-93, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25487240

RESUMEN

Traumatic brain injury and intracranial hypertension often require treatment to optimize patient outcome. There are a variety of complex medical conditions that can preclude standard approaches to the treatment of intracranial hypertension. We describe a case where a novel approach using continuous dialysis with trisodium citrate was used to optimize the outcome of a young male with acute renal failure and acute respiratory distress syndrome in the setting of acute traumatic brain injury.


Asunto(s)
Lesión Renal Aguda/terapia , Anticoagulantes/uso terapéutico , Lesiones Encefálicas/terapia , Citratos/uso terapéutico , Hipernatremia/inducido químicamente , Presión Intracraneal , Terapia de Reemplazo Renal/métodos , Lesión Renal Aguda/complicaciones , Adolescente , Anticoagulantes/farmacología , Lesiones Encefálicas/complicaciones , Citratos/farmacología , Terapia Combinada , Humanos , Masculino , Síndrome de Dificultad Respiratoria/complicaciones , Síndrome de Dificultad Respiratoria/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...