Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Am Soc Mass Spectrom ; 34(9): 1837-1846, 2023 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-37478497

RESUMEN

LC-MS analysis of therapeutic antibodies and other biotherapeutics from in-life studies (e.g., serum/plasma) has evolved from simple peptide digestion to peptide mapping and intact mass monitoring. From more advanced analytical approaches, a deeper understanding as to the fate of the biotherapeutic in vivo is gained. Here, we examine the next generation of approaches to facilitate the most comprehensive understanding of large molecule drug fate in circulation. Three case studies are presented: (1) use of relative and absolute calibration curves for biotherapeutic quantitation from the same sample set; (2) top-down mass spectrometry applied to bioanalytical assays; (3) biotherapeutic protein complexes from serum analyzed by native protein MS. We anticipate that these approaches will be further adapted and applied by other research groups.


Asunto(s)
Proteínas , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Proteínas/análisis , Péptidos , Mapeo Peptídico/métodos
2.
Anal Chem ; 95(2): 924-934, 2023 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-36534410

RESUMEN

Accurate, absolute liquid chromatography-mass spectrometry (LC-MS)-based quantification of target proteins in formalin-fixed paraffin-embedded (FFPE) tissues would greatly expand sample availability for pharmaceutical/clinical investigations but remains challenging owing to the following issues: (i) efficient/quantitative recovery of target signature peptides from FFPE tissues is essential but an optimal procedure for targeted, absolute quantification is lacking; (ii) most FFPE samples are long-term-stored; severe immunohistochemistry (IHC) signal losses of target proteins during storage were widely reported, while the effect of storage on LC-MS-based methods was unknown; and (iii) the proper strategy to prepare calibration/quality-control samples to ensure accurate targeted protein analysis in FFPE tissues remained elusive. Using targeted quantification of monoclonal antibody (mAb), antigen, and 40 tissue markers in FFPE tissues as a model system, we extensively investigate those issues and develope an LC-MS-based strategy enabling accurate and precise targeted protein quantification in FFPE samples. First, we demonstrated a surfactant cocktail-based procedure (f-SEPOD), providing high/reproducible recovery of target signature peptides from FFPE tissues. Second, a heat-accelerated degradation study within a roughly estimated 5 year storage period recapitulated the loss of protein IHC signals while LC-MS signals of all targets remained constant. This indicates that the storage of FFPE tissues mainly causes decreased immunoreactivity but unlikely chemical degradation of proteins, which strongly suggests that the storage of FFPE tissues does not cause significant quantitative bias for LC-MS-based methods. Third, while a conventional spike-and-extract approach for calibration caused substantial negative biases, a novel approach, using FFPE-treated calibration standards, enabled accurate and precise quantification. With the pipeline, we conducted the first-ever pharmacokinetics measurement of mAb and its target in FFPE tissues, where time courses by FFPE vs fresh tissues showed excellent correlation.


Asunto(s)
Péptidos , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Adhesión en Parafina , Anticuerpos Monoclonales/farmacocinética , Formaldehído/química , Fijación del Tejido
3.
J Am Soc Mass Spectrom ; 34(1): 17-26, 2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36459688

RESUMEN

Time-of-flight MS systems for biopharmaceutical and protein characterization applications may play an even more pivotal role in the future as biotherapeutics increase in drug pipelines and as top-down MS approaches increase in use. Here, a recently developed TOF MS system is examined for monoclonal antibody (mAb) characterization from serum samples. After immunocapture, purified drug material spiked into monkey serum or dosed for an in-life study is analyzed by top-down MS. While characterization aspects are a distinct advantage of the MS platform, MS system and software capabilities are also shown regarding intact protein quantitation. Such applications are demonstrated to help enable comprehensive protein molecule quantitation and characterization by use of TOF MS instrumentation.


Asunto(s)
Anticuerpos Monoclonales , Espectrometría de Masas en Tándem , Electrones , Programas Informáticos
4.
Bioanalysis ; 13(3): 147-159, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33543654

RESUMEN

Background: Surrogate monoclonal antibodies (mAbs) used in preclinical in vivo studies can be challenging to quantify due to lack of suitable immunoaffinity reagents or unavailability of the mAb protein sequence. Generic immunoaffinity reagents were evaluated to develop sensitive LC-MS/MS assays. Peptides of unknown sequence can be used for selective LC-MS quantification. Results: anti-mouse IgG1 was found to be an effective immunoaffinity reagent, enabling quantification of mouse IgG1 mAbs in mouse serum. Selective peptides of unknown sequence were applied for multiplex LC-MS quantification of two rat mAbs co-dosed in mouse. Conclusion: Generic anti-mouse IgG subtype-specific antibodies can be used to improve assay sensitivity and peptides of unknown sequence can be used to quantify surrogate mAbs when the mAb protein sequence in unavailable.


Asunto(s)
Anticuerpos Monoclonales/sangre , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Animales , Humanos , Ratones , Ratas
5.
J Am Soc Mass Spectrom ; 32(8): 1886-1900, 2021 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-32869982

RESUMEN

Recent advancements in immunocapture methods and mass spectrometer technology have enabled intact protein mass spectrometry to be applied for the characterization of antibodies and other large biotherapeutics from in-life studies. Protein molecules have not been traditionally studied by intact mass or screened for catabolites in the same manner as small molecules, but the landscape has changed. Researchers have presented methods that can be applied to the drug discovery and development stages, and others are exploring the possibilities of the new approaches. However, a wide variety of options for assay development exists without clear recommendation on best practice, and data processing workflows may have limitations depending on the vendor. In this perspective, we share experiences and recommendations for current and future application of mass spectrometry for biotherapeutic molecule monitoring from preclinical and clinical studies.


Asunto(s)
Espectrometría de Masas/métodos , Proteínas/análisis , Proteínas/farmacocinética , Animales , Biotransformación , Cromatografía de Afinidad/métodos , Cromatografía Liquida , Evaluación Preclínica de Medicamentos , Humanos , Inmunoconjugados/análisis , Espectrometría de Masas/economía , Espectrometría de Masas/instrumentación , Proteínas/aislamiento & purificación , Manejo de Especímenes
6.
Drug Metab Dispos ; 46(4): 451-457, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29386233

RESUMEN

Therapeutic biologics have become a fast-growing segment within the pharmaceutical industry during the past 3 decades. Although the metabolism of biologics is more predictable than small molecule drugs, biotransformation can significantly affect the activity of biologics. Unfortunately, there are only a limited number of published studies on the biotransformation of biologics, most of which are focused on one or a few types of modifications. In this study, an untargeted LC-MS-based differential analysis approach was developed to rapidly and precisely determine the universal biotransformation profile of biologics with the assistance of bioinformatic tools. A human monoclonal antibody (mAb) was treated with t-butyl hydroperoxide and compared with control mAb using a bottom-up proteomics approach. Thirty-seven types of post-translational modifications were identified, and 38 peptides were significantly changed. Moreover, although all modifications were screened and detected, only the ones related to the treatment process were revealed by differential analysis. Other modifications that coexist in both groups were filtered out. This novel analytical strategy can be effectively applied to study biotransformation-mediated protein modifications, which will streamline the process of biologic drug discovery and development.


Asunto(s)
Productos Biológicos/química , Biotransformación/fisiología , Cromatografía Liquida/métodos , Proteínas/química , Espectrometría de Masas en Tándem/métodos , Animales , Anticuerpos Monoclonales/química , Biología Computacional/métodos , Descubrimiento de Drogas/métodos , Humanos , Péptidos/química , Procesamiento Proteico-Postraduccional/efectos de los fármacos , Proteómica/métodos , Ratas
8.
Bioanalysis ; 8(15): 1611-1622, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27397670

RESUMEN

BACKGROUND: Isomerization of aspartic acid and deamidation of asparagine are two common amino acid modifications that are of particular concern if located within the complementarity-determining region of therapeutic antibodies. Questions arise as to the extent of modification occurring in circulation due to potential exposure of the therapeutic antibody to different pH regimes. RESULTS: To enable evaluation of site-specific isomerization and deamidation of human mAbs in vivo, immunoprecipitation (IP) has been combined with LC-MS providing selective enrichment, separation and detection of naive and modified forms of tryptic peptides comprising complementarity-determining region sequences. CONCLUSION: IP-LC-MS can be applied to simultaneously quantify in vivo drug concentrations and measure the extent of isomerization or deamidation in PK studies conducted during the drug discovery stage.


Asunto(s)
Anticuerpos Monoclonales/química , Asparagina/análisis , Ácido Aspártico/análisis , Secuencia de Aminoácidos , Animales , Anticuerpos Monoclonales/sangre , Cromatografía Liquida/métodos , Humanos , Inmunoprecipitación/métodos , Isomerismo , Macaca fascicularis , Masculino , Espectrometría de Masas en Tándem/métodos
9.
Vaccine ; 34(35): 4250-4256, 2016 07 29.
Artículo en Inglés | MEDLINE | ID: mdl-27269057

RESUMEN

Trivalent native outer membrane vesicles (nOMVs) derived from three genetically modified Neisseria meningitidis serogroup B strains have been previously evaluated immunologically in mice and rabbits. This nOMV vaccine elicited serum bactericidal activity (SBA) against multiple N. meningitidis serogroup B strains as well as strains from serogroups C, Y, W, and X. In this study, we used trivalent nOMVs isolated from the same vaccine strains and evaluated their immunogenicity in an infant Rhesus macaque (IRM) model whose immune responses to the vaccine are likely to be more predictive of the responses in human infants. IRMs were immunized with trivalent nOMV vaccines and sera were evaluated for exogenous human serum complement-dependent SBA (hSBA). Antibody responses to selected hSBA generating antigens contained within the trivalent nOMVs were also measured and we found that antibody titers against factor H binding protein variant 2 (fHbpv2) were very low in the sera from animals immunized with these original nOMV vaccines. To increase the fHbp content in the nOMVs, the vaccine strains were further genetically altered by addition of another fHbp gene copy into the porB locus. Trivalent nOMVs from the three new vaccine strains had higher fHbp antigen levels and generated higher anti-fHbp antibody responses in immunized mice and IRMs. As expected, fHbp insertion into the porB locus resulted in no PorB expression. Interestingly, higher expression of PorA, an hSBA generating antigen, was observed for all three modified vaccine strains. Compared to the trivalent nOMVs from the original strains, higher PorA levels in the improved nOMVs resulted in higher anti-PorA antibody responses in mice and IRMs. In addition, hSBA titers against other strains with PorA as the only hSBA antigen in common with the vaccine strains also increased.


Asunto(s)
Antígenos Bacterianos/inmunología , Proteínas Bacterianas/inmunología , Ingeniería Genética , Inmunogenicidad Vacunal , Vacunas Meningococicas/inmunología , Vesículas Transportadoras/inmunología , Animales , Anticuerpos Antibacterianos/sangre , Formación de Anticuerpos , Antígenos Bacterianos/genética , Proteínas Bacterianas/genética , Macaca mulatta , Vacunas Meningococicas/genética , Neisseria meningitidis , Neisseria meningitidis Serogrupo B , Porinas/genética
10.
Bioanalysis ; 8(4): 265-74, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26807991

RESUMEN

BACKGROUND: A target protein-based affinity extraction LC-MS/MS method was developed to enable plasma level determination following ultralow dosing (0.1-3 µg/kg) of an inhibitor of apoptosis proteins molecule. Methodology & results: Affinity extraction (AE) utilizing immobilized target protein BIR2/BIR3 was used to selectively capture the inhibitor of apoptosis proteins molecule from dog plasma and enable removal of background matrix components. Pretreatment of plasma samples using protein precipitation was found to provide an additional sensitivity gain. A LLOQ of 7.8 pM was achieved by combining protein precipitation with AE. The method was used to support an ultralow dose dog toxicity study. CONCLUSION: AE-LC-MS/MS, utilizing target protein, is a highly sensitive methodology for small molecule quantification with potential for broader applicability.


Asunto(s)
Análisis Químico de la Sangre/métodos , Fraccionamiento Químico/métodos , Cromatografía Liquida/métodos , Proteínas Inhibidoras de la Apoptosis/antagonistas & inhibidores , Isoquinolinas/análisis , Límite de Detección , Oligopéptidos/análisis , Bibliotecas de Moléculas Pequeñas/análisis , Espectrometría de Masas en Tándem/métodos , Animales , Perros , Femenino , Humanos , Proteínas Inmovilizadas/antagonistas & inhibidores , Proteínas Inmovilizadas/química , Proteínas Inhibidoras de la Apoptosis/química , Isoquinolinas/química , Isoquinolinas/farmacología , Masculino , Oligopéptidos/química , Oligopéptidos/farmacología , Bibliotecas de Moléculas Pequeñas/química , Bibliotecas de Moléculas Pequeñas/farmacología
11.
Hum Vaccin Immunother ; 11(6): 1518-25, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25997113

RESUMEN

The development of a multivalent outer membrane vesicle (OMV) vaccine where each strain contributes multiple key protein antigens presents numerous analytical challenges. One major difficulty is the ability to accurately and specifically quantitate each antigen, especially during early development and process optimization when immunoreagents are limited or unavailable. To overcome this problem, quantitative mass spectrometry methods can be used. In place of traditional mass assays such as enzyme-linked immunosorbent assays (ELISAs), quantitative LC-MS/MS using multiple reaction monitoring (MRM) can be used during early-phase process development to measure key protein components in complex vaccines in the absence of specific immunoreagents. Multiplexed, label-free quantitative mass spectrometry methods using protein extraction by either detergent or 2-phase solvent were developed to quantitate levels of several meningococcal serogroup B protein antigens in an OMV vaccine candidate. Precision was demonstrated to be less than 15% RSD for the 2-phase extraction and less than 10% RSD for the detergent extraction method. Accuracy was 70 to 130% for the method using a 2-phase extraction and 90-110% for detergent extraction. The viability of MS-based protein quantification as a vaccine characterization method was demonstrated and advantages over traditional quantitative methods were evaluated. Implementation of these MS-based quantification methods can help to decrease the development time for complex vaccines and can provide orthogonal confirmation of results from existing antigen quantification techniques.


Asunto(s)
Antígenos Bacterianos/análisis , Proteínas Bacterianas/análisis , Cromatografía Liquida/métodos , Vacunas Meningococicas/química , Espectrometría de Masas en Tándem/métodos , Descubrimiento de Drogas/métodos , Humanos , Neisseria meningitidis Serogrupo B/inmunología
12.
Bioanalysis ; 6(13): 1795-811, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25157486

RESUMEN

BACKGROUND: The disease state can modulate the penetration of large antibody-sized therapeutic molecules into affected tissues. Suitable bioanalytical methods are required for the quantitative analysis of drug tissue levels to enable a better understanding of the parameters influencing drug penetration and target engagement. RESULTS: Described is a sensitive and selective LC-MS/MS assay for the quantification of human mAb molecules in mouse tissues. By homogenizing tissues directly into serum, a common serum calibration curve can be used for multiple tissues. A generic procedure was used for affinity enrichment. An analytical range of 20 - 20,000 ng/ml was achieved in serum. CONCLUSION: The method described here can be applied for the quantitative analysis of mAb and Fc-fusion therapeutic molecules in a variety of animal tissue matrices.


Asunto(s)
Anticuerpos Monoclonales/análisis , Cromatografía Líquida de Alta Presión , Espectrometría de Masas en Tándem , Secuencia de Aminoácidos , Animales , Anticuerpos Monoclonales/sangre , Anticuerpos Monoclonales/metabolismo , Anticuerpos Monoclonales Humanizados/análisis , Anticuerpos Monoclonales Humanizados/sangre , Anticuerpos Monoclonales Humanizados/metabolismo , Cromatografía de Afinidad , Femenino , Humanos , Hígado/metabolismo , Ratones , Ratones Endogámicos C57BL , Datos de Secuencia Molecular , Péptidos/análisis , Análisis de Regresión , Piel/metabolismo , Tripsina/metabolismo , Ustekinumab
13.
Anal Chem ; 82(16): 6877-86, 2010 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-20704377

RESUMEN

Quantification of a PEGylated peptide in human plasma using LC-MS/MS to support clinical studies presented challenges in terms of assay sensitivity, selectivity, and ruggedness. To ensure specific recognition of PEGylated species, an immunoaffinity purification method (IAP) using anti-PEG antibody followed by two-dimensional (2D) LC-MS/MS was developed for MK-2662, an investigational peptide containing 38 amino acids with a 40 kDa branched PEG [poly(ethylene glycol)] at C-terminus. Biotinylated anti-PEG antibody, bound to streptavidin-coated magnetic beads, was used to capture MK-2662 and its stable-isotope-labeled internal standard from human plasma. After on-bead digestion with trypsin, the supernatant was injected on a 2D high-performance liquid chromatography (HPLC) system constructed with strong cation-exchange and reversed-phase columns, followed by MS/MS detection of the surrogate N(1-12)-mer of MK-2662 on an API5000. The assay ruggedness was improved by optimizing the trypsin digestion and sample storage conditions. The intraday validation, conducted in parallel with protein precipitation (PPT) assay, demonstrated 94.8-105.8% accuracy with <9.76% coefficient of variation (CV) for IAP, and 99.0-101.0% accuracy with <3.43% CV for PPT, over a dynamic range of 2-200 nM and 1-1000 nM, respectively. A cross comparison, performed using clinical samples, showed that the values obtained from IAP assay were about 15-30% lower than those from PPT method, which supports more specific PEG recognition provided by IAP.


Asunto(s)
Anticuerpos/inmunología , Cromatografía Líquida de Alta Presión/métodos , Péptidos/sangre , Polietilenglicoles/química , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Cromatografía de Afinidad/métodos , Humanos , Datos de Secuencia Molecular , Péptidos/química , Péptidos/aislamiento & purificación , Tripsina/metabolismo
14.
Diabetes ; 55(4): 1034-42, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16567526

RESUMEN

Delayed-rectifier K+ currents (I(DR)) in pancreatic beta-cells are thought to contribute to action potential repolarization and thereby modulate insulin secretion. The voltage-gated K+ channel, K(V)2.1, is expressed in beta-cells, and the biophysical characteristics of heterologously expressed channels are similar to those of I(DR) in rodent beta-cells. A novel peptidyl inhibitor of K(V)2.1/K(V)2.2 channels, guangxitoxin (GxTX)-1 (half-maximal concentration approximately 1 nmol/l), has been purified, characterized, and used to probe the contribution of these channels to beta-cell physiology. In mouse beta-cells, GxTX-1 inhibits 90% of I(DR) and, as for K(V)2.1, shifts the voltage dependence of channel activation to more depolarized potentials, a characteristic of gating-modifier peptides. GxTX-1 broadens the beta-cell action potential, enhances glucose-stimulated intracellular calcium oscillations, and enhances insulin secretion from mouse pancreatic islets in a glucose-dependent manner. These data point to a mechanism for specific enhancement of glucose-dependent insulin secretion by applying blockers of the beta-cell I(DR), which may provide advantages over currently used therapies for the treatment of type 2 diabetes.


Asunto(s)
Canales de Potasio de Tipo Rectificador Tardío/fisiología , Glucosa/farmacología , Insulina/metabolismo , Islotes Pancreáticos/fisiología , Bloqueadores de los Canales de Potasio/farmacología , Secuencia de Aminoácidos , Animales , Canales de Potasio de Tipo Rectificador Tardío/efectos de los fármacos , Secreción de Insulina , Islotes Pancreáticos/efectos de los fármacos , Cinética , Potenciales de la Membrana/efectos de los fármacos , Potenciales de la Membrana/fisiología , Ratones , Datos de Secuencia Molecular , Péptidos/química , Péptidos/farmacología , Bloqueadores de los Canales de Potasio/química , Venenos de Araña/química , Venenos de Araña/farmacología
15.
Rapid Commun Mass Spectrom ; 17(14): 1600-10, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12845586

RESUMEN

Atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) ion trap mass spectrometry (ITMS) has been evaluated for automated protein identification. By using signal averaging and long ion-injection times, protein identification limits in the 50-fmol range are achieved for standard protein digests. Data acquisition requires 7.5 min or less per sample and the MS/MS spectra files are automatically processed using the SEQUEST database searching algorithm. AP-MALDI-ITMS was compared with the widely used methods of microLC/MS/MS (ion trap) and automated MALDI-TOF peptide mass mapping. Sample throughput is 10-fold greater using AP-MALDI compared with microcapillary liquid chromatography/tandem mass spectrometry (microLC/MS/MS). The protein sequence coverage obtained from AP-MALDI-MS/MS spectra matched by SEQUEST is lower compared with microLC/MS/MS and MALDI-TOF mass mapping. However, by using the AP-MALDI full-scan peptide mass fingerprint spectrum, sequence coverage is increased. AP-MALDI-ITMS was applied for the analysis of Coomassie blue stained gels and was found to be a useful platform for rapid protein identification.


Asunto(s)
Proteínas/química , Animales , Autoanálisis , Catalasa/química , Cromatografía Líquida de Alta Presión , Electroforesis en Gel de Poliacrilamida , Femenino , Ratas , Ratas Sprague-Dawley , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
16.
Biochemistry ; 41(50): 14734-47, 2002 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-12475222

RESUMEN

Two peptides, ProTx-I and ProTx-II, from the venom of the tarantula Thrixopelma pruriens, have been isolated and characterized. These peptides were purified on the basis of their ability to reversibly inhibit the tetrodotoxin-resistant Na channel, Na(V) 1.8, and are shown to belong to the inhibitory cystine knot (ICK) family of peptide toxins interacting with voltage-gated ion channels. The family has several hallmarks: cystine bridge connectivity, mechanism of channel inhibition, and promiscuity across channels within and across channel families. The cystine bridge connectivity of ProTx-II is very similar to that of other members of this family, i.e., C(2) to C(16), C(9) to C(21), and C(15) to C(25). These peptides are the first high-affinity ligands for tetrodotoxin-resistant peripheral nerve Na(V) channels, but also inhibit other Na(V) channels (IC(50)'s < 100 nM). ProTx-I and ProTx-II shift the voltage dependence of activation of Na(V) 1.5 to more positive voltages, similar to other gating-modifier ICK family members. ProTx-I also shifts the voltage dependence of activation of Ca(V) 3.1 (alpha(1G), T-type, IC(50) = 50 nM) without affecting the voltage dependence of inactivation. To enable further structural and functional studies, synthetic ProTx-II was made; it adopts the same structure and has the same functional properties as the native peptide. Synthetic ProTx-I was also made and exhibits the same potency as the native peptide. Synthetic ProTx-I, but not ProTx-II, also inhibits K(V) 2.1 channels with 10-fold less potency than its potency on Na(V) channels. These peptides represent novel tools for exploring the gating mechanisms of several Na(V) and Ca(V) channels.


Asunto(s)
Péptidos/farmacología , Bloqueadores de los Canales de Sodio/farmacología , Canales de Sodio/metabolismo , Venenos de Araña/farmacología , Secuencia de Aminoácidos , Animales , Bloqueadores de los Canales de Calcio/química , Bloqueadores de los Canales de Calcio/aislamiento & purificación , Bloqueadores de los Canales de Calcio/farmacología , Línea Celular , Disulfuros/química , Electrofisiología , Humanos , Activación del Canal Iónico/efectos de los fármacos , Datos de Secuencia Molecular , Péptidos/química , Péptidos/aislamiento & purificación , Bloqueadores de los Canales de Potasio/química , Bloqueadores de los Canales de Potasio/aislamiento & purificación , Bloqueadores de los Canales de Potasio/farmacología , Ratas , Ratas Wistar , Bloqueadores de los Canales de Sodio/química , Bloqueadores de los Canales de Sodio/aislamiento & purificación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Venenos de Araña/química , Venenos de Araña/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...