Photonic technologies promise to deliver quantitative, multiplex, and inexpensive medical diagnostic platforms by leveraging the highly scalable processes developed for the fabrication of semiconductor microchips. However, in practice, the affordability of these platforms is limited by complex and expensive sample handling and optical alignment. We previously reported the development of a disposable photonic assay that incorporates inexpensive plastic micropillar microfluidic cards for sample delivery. That system as developed was limited to singleplex assays due to its optical configuration. To enable multiplexing, we report a new approach addressing multiplex light I/O, in which the outputs of individual grating couplers on a photonic chip are mapped to fibers in a fiber bundle. As demonstrated in the context of detecting antibody responses to influenza and SARS-CoV-2 antigens in human serum and saliva, this enables multiplexing in an inexpensive, disposable, and compact format.


Asunto(s)
Técnicas Biosensibles , COVID-19 , SARS-CoV-2 , Humanos , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , SARS-CoV-2/inmunología , COVID-19/diagnóstico , COVID-19/inmunología , Saliva/química , Anticuerpos Antivirales/inmunología , Anticuerpos Antivirales/sangre , Óptica y Fotónica , Dispositivos Laboratorio en un Chip
2.
J Acoust Soc Am ; 151(5): 3083, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35649929

RESUMEN

This work presents three-dimensional (3D) numerical analysis of acoustic radiation force on an elastic microsphere suspended in a viscous fluid. Acoustophoresis of finite-sized, neutrally buoyant, nearly incompressible soft particles may improve by orders of magnitude and change directions when going through resonant vibrations. These findings offer the potential to manipulate and separate microparticles based on their resonance frequency. This concept has profound implications in cell and microparticle handling, 3D printing, and enrichment in lab-on-chip applications. The existing analytical body of work can predict spheroidal harmonics of an elastic sphere and acoustic radiation force based on monopole and dipole scatter in an ideal fluid. However, little attention is given to the complex interplay of resonant fluid and solid bodies that generate acoustic radiation. The finite element method is used to find resonant modes, damping factors, and acoustic forces of an elastic sphere subject to a standing acoustic wave. Under fundamental spheroidal modes, the radiation force fluctuates significantly around analytical values due to constructive or destructive scatter-incident wave interference. This suggests that for certain materials, relevant to acoustofluidic applications, particle resonances are an important scattering mechanism and design parameter. The 3D model may be applied to any number of particles regardless of geometry or background acoustic field.

3.
Nano Lett ; 21(21): 9146-9152, 2021 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-34672604

RESUMEN

Understanding the optoelectronic properties of semiconducting polymers under external strain is essential for their applications in flexible devices. Although prior studies have highlighted the impact of static and macroscopic strains, assessing the effect of a local transient deformation before structural relaxation occurs remains challenging. Here, we employ scanning ultrafast electron microscopy (SUEM) to image the dynamics of a photoinduced transient strain in the semiconducting polymer poly(3-hexylthiophene) (P3HT). We observe that the photoinduced SUEM contrast, corresponding to the local change of secondary electron emission, exhibits an unusual ring-shaped profile. We attribute the observation to the electronic structure modulation of P3HT caused by a photoinduced strain field owing to its low modulus and strong electron-lattice coupling, supported by a finite-element analysis. Our work provides insights into tailoring optoelectronic properties using transient mechanical deformation in semiconducting polymers and demonstrates the versatility of SUEM to study photophysical processes in diverse materials.

4.
Lab Chip ; 21(15): 2913-2921, 2021 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-34160511

RESUMEN

Decades of research have shown that biosensors using photonic circuits fabricated using CMOS processes can be highly sensitive, selective, and quantitative. Unfortunately, the cost of these sensors combined with the complexity of sample handling systems has limited the use of such sensors in clinical diagnostics. We present a new "disposable photonics" sensor platform in which rice-sized (1 × 4 mm) silicon nitride ring resonator sensor chips are paired with plastic micropillar fluidic cards for sample handling and optical detection. We demonstrate the utility of the platform in the context of detecting human antibodies to SARS-CoV-2, both in convalescent COVID-19 patients and for subjects undergoing vaccination. Given its ability to provide quantitative data on human samples in a simple, low-cost single-use format, we anticipate that this platform will find broad utility in clinical diagnostics for a broad range of assays.


Asunto(s)
COVID-19 , Óptica y Fotónica , Bioensayo , Prueba de COVID-19 , Análisis Costo-Beneficio , Humanos , SARS-CoV-2
5.
J Acoust Soc Am ; 148(1): 359, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32752779

RESUMEN

The performance of a micro-acousto-fluidic device designed for microparticle trapping is simulated using a three-dimensional (3D) numerical model. It is demonstrated by numerical simulations that geometrically asymmetric architecture and actuation can increase the acoustic radiation forces in a liquid-filled cavity by almost 2 orders of magnitude when setting up a standing pressure half wave in a microfluidic chamber. Similarly, experiments with silicon-glass devices show a noticeable improvement in acoustophoresis of 20-µm silica beads in water when asymmetric devices are used. Microparticle acoustophoresis has an extensive array of applications in applied science fields ranging from life sciences to 3D printing. A more efficient and powerful particle manipulation system can boost the overall effectiveness of an acoustofluidic device. The numerical simulations are developed in the COMSOL Multiphysics® software package (COMSOL AB, Stockholm, Sweden). By monitoring the modes and magnitudes of simulated acoustophoretic fields in a relatively wide range of ultrasonic frequencies, a map of device performance is obtained. 3D resonant acoustophoretic fields are identified to quantify the improved performance of the chips with an asymmetric layout. Four different device designs are analyzed experimentally, and particle tracking experimental data qualitatively supports the numerical results.

6.
Analyst ; 145(9): 3440-3446, 2020 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-32259176

RESUMEN

Fentanyl and its analogs have been at the center of the opioid epidemic currently wreaking havoc in the United States. One major element in the opioid crisis is the growing number of clandestine fentanyl labs being reported by enforcement agencies. The development of new analytical methods for detecting and identifying fentanyl and its congeners is among the useful tools in our goal to limit the use of this dangerous family of narcotics. Herein we describe an analytical technique using surface-enhanced Raman spectroscopy (SERS) and a microfluidic device, for detecting fentanyl and two of its chemical precursors, despropionylfentanyl (4ANPP) and N-phenethyl-4-piperidinone (NPP). The vibrational spectra of this family of analytes are very similar, making them difficult to distinguish by traditional means. In addition to taking advantage of the sensitivity provided by SERS, we developed a chemometric approach utilizing a hierarchical partial least squares-discriminant analysis algorithm that allowed us to distinguish spectra that possess many similar features.


Asunto(s)
Fentanilo/análisis , Espectrometría Raman/métodos , Analgésicos Opioides/análisis , Análisis Discriminante , Fentanilo/análogos & derivados , Fentanilo/química , Dispositivos Laboratorio en un Chip , Análisis de los Mínimos Cuadrados
7.
ACS Appl Mater Interfaces ; 11(14): 13777-13786, 2019 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-30880379

RESUMEN

Bipolar electrodes (BPEs) are conductors that, when exposed to an electric field, polarize and promote the accumulation of counterionic charge near their poles. The rich physics of electrokinetic behavior near BPEs has not yet been rigorously studied, with our current understanding of such bipolar effects being restricted to steady-state conditions (under constant applied fields). Here, we reveal the dynamic electrokinetic and electrochemical phenomena that occur near nanoconfined BPEs throughout all stages of a reaction. Specifically, we demonstrate, both experimentally and through numerical modeling, that the removal of an electric field produces solution-phase charge imbalances in the vicinity of the BPE poles. These imbalances induce intense and short-lived nonequilibrium electric fields that drive the rapid transport of ions toward specific BPE locations. To determine the origin of these electrokinetic effects, we monitored the movement and fluorescent behavior (enhancement or quenching) of charged fluorophores within well-defined nanofluidic architectures via real-time optical detection. By systematically varying the nature of the fluorophore, the concentration of the electrolyte, the strength of the applied field, and oxide growth on the BPE surface, we dissect the ion transport events that occur in the aftermath of field-induced polarization. The results contained in this work provide new insights into transient bipolar electrokinetics that improve our understanding of current analytical platforms and can drive the development of new micro- and nanoelectrochemical systems.

8.
Analyst ; 144(9): 3080-3087, 2019 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-30919846

RESUMEN

Opioid overdose deaths resulting from heroin contaminated with the potent opioid agonist fentanyl, are currently a serious public health issue. A rapid and reliable method for identifying fentanyl-laced heroin could lead to reduced opioid overdose. Herein, we describe a strategy for detecting fentanyl at low concentrations in the presence of heroin, based on the significant hydrophobicity of fentanyl compared to heroin hydrochloride, by preferentially extracting trace concentrations of fentanyl using ultrasound-assisted emulsification microextraction using octanol as the extracting phase. Surface-enhanced Raman spectroscopy (SERS), is enabled by exposing the analyte to silver nanoparticle-coated SiO2 nanoparticles, designed to be stable in mixtures of octanol and ethanol. The sample is then loaded into an SU8/glass microfluidic device that is compatible with non-aqueous solutions. The SERS-active nanoparticles are aggregated by dielectrophoresis using microelectrodes embedded in the microfluidic channels, and the nanoparticle aggregates are interrogated using Raman spectroscopy. Using this method, we were able to reliably detect fentanyl from samples with as low as 1 : 10 000 (mol/mol) fentanyl-to-heroin ratio, improving the limits of detection of fentanyl-laced heroin samples by two orders of magnitude over current techniques. The described system could also be useful in chemical detection where rapid and robust preconcentration of trace hydrophobic analytes, and rapid SERS detection in non-aqueous solvents is indicated.


Asunto(s)
Contaminación de Medicamentos , Fentanilo/análisis , Heroína/análisis , Drogas Ilícitas/análisis , Técnicas Analíticas Microfluídicas/métodos , Espectrometría Raman/métodos , Fentanilo/química , Oro/química , Interacciones Hidrofóbicas e Hidrofílicas , Dispositivos Laboratorio en un Chip , Límite de Detección , Microextracción en Fase Líquida , Nanopartículas del Metal/química , Microelectrodos , Técnicas Analíticas Microfluídicas/instrumentación , Dióxido de Silicio/química , Plata/química
9.
Analyst ; 144(5): 1818-1824, 2019 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-30672922

RESUMEN

Direct detection, or inferring the presence of illicit substances, is of great forensic and toxicological value. Surface-enhanced Raman spectroscopy (SERS) has been shown capable of detecting such molecules in a quick and sensitive manner. Herein we describe an analysis strategy for quantitation of low concentrations of three analytes (methamphetamine, cocaine, and papaverine) by SERS analysis using the citrate capping agent that initially saturates the silver nanoparticles' surface as an in situ standard. The citrate is subsequently displaced by the analyte to an extent dependent on the analyte's concentration in the analyte solution. A general model for the competitive adsorption of citrate and a target analyte was developed and used to determine the relative concentrations of the two species coexisting on the surface of the silver nanoparticles. To apply this model, classical least squares (CLS) was used to extract the relative SERS contribution of each of the two species in a given SERS spectrum, thereby accurately determining the analyte concentration in the sample solution. This approach, in essence, transforms citrate into a local standard against which the concentration of an analyte can be reliably determined.

10.
Anal Chem ; 90(13): 7930-7936, 2018 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-29863841

RESUMEN

Rapid chemical identification of drugs of abuse in biological fluids such as saliva is of growing interest in healthcare and law enforcement. Accordingly, a label-free detection platform that accepts biological fluid samples is of great practical value. We report a microfluidics-based dielectrophoresis-induced surface enhanced Raman spectroscopy (SERS) device, which is capable of detecting physiologically relevant concentrations of methamphetamine in saliva in under 2 min. In this device, iodide-modified silver nanoparticles are trapped and released on-demand using electrodes integrated in a microfluidic channel. Principal component analysis (PCA) is used to reliably distinguish methamphetamine-positive samples from the negative control samples. Passivation of the electrodes and flow channels minimizes microchannel fouling by nanoparticles, which allows the device to be cleared and reused multiple times.


Asunto(s)
Nanopartículas del Metal/química , Plata/química , Espectrometría Raman/métodos , Impedancia Eléctrica , Electroforesis , Análisis de Componente Principal , Propiedades de Superficie
11.
Nanomedicine ; 14(4): 1279-1287, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29597048

RESUMEN

Canine lower urinary tract neoplasia is a clinically important disease process that has high mortality due to late stage diagnosis and poorly durable response to treatment. Non-invasive diagnostic techniques (e.g. dipstick test, urine cytology) currently have poor diagnostic value, while more invasive tests (e.g. cystoscopy and biopsy) are costly and often require general anesthesia. We have developed and herein describe a quantitative cytological analysis method based on the use of surface-enhanced Raman spectroscopy (SERS), for identifying cancerous transitional cells in urine using SERS biotags (SBTs) carrying the peptide PLZ4 (amino acid sequence cQDGRMGFc) that targets malignant transitional cells. By analyzing the ratio of the PLZ4-SBTs to an on board control we were able to show that transitional cells had significantly higher ratios (P < 0.05) in patients diagnosed with transitional cell carcinoma (TCC) than in healthy samples.


Asunto(s)
Carcinoma de Células Transicionales/diagnóstico , Espectrometría Raman/métodos , Animales , Biomarcadores de Tumor/orina , Biopsia/métodos , Carcinoma de Células Transicionales/orina , Cistoscopía/métodos , Perros , Neoplasias de la Vejiga Urinaria/diagnóstico , Neoplasias de la Vejiga Urinaria/orina
12.
Anal Chem ; 89(3): 1684-1688, 2017 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-28208284

RESUMEN

Papaverine is a non-narcotic alkaloid found endemically and uniquely in the latex of the opium poppy. It is normally refined out of the opioids that the latex is typically collected for, hence its presence in a sample is strong prima facie evidence that the carrier from whom the sample was collected is implicated in the mass cultivation of poppies or the collection and handling of their latex. We describe an analysis technique combining surface-enhanced Raman spectroscopy (SERS) with microfluidics for detecting papaverine at low concentrations and show that its SERS spectrum has unique spectroscopic features that allows its detection at low concentrations among typical opioids. The analysis requires approximately 2.5 min from sample loading to results, which is compatible with field use. The weak acid properties of papaverine hydrochloride were investigated, and Raman bands belonging to the protonated and unprotonated forms of the isoquinoline ring of papaverine were identified.

13.
Anal Chem ; 88(21): 10513-10522, 2016 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-27715011

RESUMEN

A microfluidic device is being developed by University of California-Santa Barbara as part of a joint effort with the United States Army to develop a portable, rapid drug detection device. Surface-enhanced Raman spectroscopy (SERS) is used to provide a sensitive, selective detection technique within the microfluidic platform employing metallic nanoparticles as the SERS medium. Using several illicit drugs as analytes, the work presented here describes the efforts of the Edgewood Chemical Biological Center to optimize the microfluidic platform by investigating the role of nanoparticle material, nanoparticle size, excitation wavelength, and capping agents on the performance, and drug concentration detection limits achievable with Ag and Au nanoparticles that will ultimately be incorporated into the final design. This study is particularly important as it lays out a systematic comparison of limits of detection and potential interferences from working with several nanoparticle capping agents-such as tannate, citrate, and borate-which does not seem to have been done previously as the majority of studies only concentrate on citrate as the capping agent. Morphine, cocaine, and methamphetamine were chosen as test analytes for this study and were observed to have limits of detection (LOD) in the range of (1.5-4.7) × 10-8 M (4.5-13 ng/mL), with the borate capping agent having the best performance.


Asunto(s)
Dispositivos Laboratorio en un Chip , Espectrometría Raman/instrumentación , Detección de Abuso de Sustancias/instrumentación , Analgésicos Opioides/análisis , Anestésicos Locales/análisis , Estimulantes del Sistema Nervioso Central/análisis , Cocaína/análisis , Oro/química , Humanos , Límite de Detección , Nanopartículas del Metal/química , Metanfetamina/análisis , Morfina/análisis , Plata/química , Propiedades de Superficie
14.
Sci Rep ; 6: 33571, 2016 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-27677238

RESUMEN

Most studies of the mean-free path accumulation function (MFPAF) rely on optical techniques to probe heat transfer at length scales on the order of the phonon mean-free path. In this paper, we propose and implement a purely electrical probe of the MFPAF that relies on photo-lithographically defined heater-thermometer separation to set the length scale. An important advantage of the proposed technique is its insensitivity to the thermal interfacial impedance and its compatibility with a large array of temperature-controlled chambers that lack optical ports. Detailed analysis of the experimental data based on the enhanced Fourier law (EFL) demonstrates that heat-carrying phonons in gallium arsenide have a much wider mean-free path spectrum than originally thought.

15.
J Colloid Interface Sci ; 461: 32-38, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26397906

RESUMEN

In this study, we improve on our 3D steady-state model of electrophoretic motion of spherical particles in bounded fluidic channels (Liu et al., 2014) to include the effect of nonsymmetric electrolytes, and further validate this improved model with detailed comparisons to experimental data. Specifically, we use the experimentally-measured particle mobilities from the work of Semenov et al. (2013), Napoli et al. (2011), and Wynne et al. (2012) to determine the corresponding particle zeta potentials using our model, and compare these results with classical theory. Incorporating the effects of nonsymmetric electrolytes, EDL polarization, and confinement, we show that our improved model is applicable to a wide range of practical experimental conditions, for example, particles that have high zeta potentials in a bounded channel filled with nonsymmetric electrolyte solutions, where classical theory is not applicable. In addition, we find that when electrolyte concentration is comparable to the concentration of hydronium or hydroxide ions, the complicated composition of ions increases the particle mobility. Finally, increased electrophoretic mobility can be observed when buffer solutions (phosphate or borate) were used as electrolyte solutions in experiments as opposed to simple symmetric electrolytes.

16.
Analyst ; 140(15): 5003-5, 2015 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-26087055

RESUMEN

Ampicillin, a common antibiotic, is detected at trace concentrations in milk using surface enhanced Raman spectroscopy in a microfluidic device, using less than 20 µL of sample, in 10 minutes, with minimal off-chip preparation. The device is configured so as to favor the interaction of the analyte with colloidal silver, and the optimization of the aggregation of the silver nanoparticles so as to increase the SERS intensity and the consequential sensitivity of analyte detection.


Asunto(s)
Ampicilina/análisis , Antibacterianos/análisis , Técnicas Analíticas Microfluídicas/instrumentación , Leche/química , Espectrometría Raman/instrumentación , Animales , Bovinos , Diseño de Equipo , Nanopartículas del Metal/química , Técnicas Analíticas Microfluídicas/economía , Tamaño de la Muestra , Plata/química
17.
ACS Nano ; 9(4): 4328-36, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25781324

RESUMEN

Reliable identification and collection of cells from bodily fluids is of growing interest for monitoring patient response to therapy and for early detection of disease or its recurrence. We describe a detection platform that combines microfluidics with surface-enhanced Raman spectroscopy (SERS) for the identification of individual mammalian cells continuously flowing in a microfluidics channel. A mixture of cancerous and noncancerous prostate cells was incubated with SERS biotags (SBTs) developed and synthesized by us, then injected into a flow-focused microfluidic channel, which forces the cells into a single file. The spectrally rich SBTs are based on a silver nanoparticle dimer core labeled with a Raman-active small reporter molecule paired with an affinity biomolecule, providing a unique barcode whose presence in a composite SERS spectrum can be deconvoluted. Individual cancer cells passing through the focused laser beam were correctly identified among a proportionally larger number of other cells by their Raman signatures. We examine two deconvolution strategies: principal component analysis and classical least-squares. The deconvolution strategies are used to unmix the overall spectrum to determine the relative contributions between two SBT barcodes, where one SBT barcode indicates neuropilin-1 overexpression, while a second SBT barcode is more universal and indicates unspecific binding to a cell's membrane. Highly reliable results were obtained for all of the cell mixture ratios tested, the lowest being 1 in 100 cells.


Asunto(s)
Separación Celular/instrumentación , Separación Celular/métodos , Dispositivos Laboratorio en un Chip , Espectrometría Raman , Línea Celular Tumoral , Supervivencia Celular , Humanos , Hidrodinámica , Análisis de los Mínimos Cuadrados , Análisis de Componente Principal , Propiedades de Superficie , Factores de Tiempo
18.
J Phys Chem B ; 118(9): 2414-21, 2014 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-24512008

RESUMEN

The evaporation rate and internal convective flows of a sessile droplet with a pinned contact line were formulated and investigated numerically. We developed and analyzed a unified numerical model that includes the effects of temperature, droplet volume, and contact angle on evaporation rate and internal flows. The temperature gradient on the air/liquid interface causes an internal flow due to Marangoni stress, which provides good convective mixing within the droplet, depending upon Marangoni number. As the droplet volume decreases, the thermal gradient becomes smaller and the Marangoni flow becomes negligible. Simultaneously, as the droplet height decreases, evaporation-induced flow creates a large jet-like flow radially toward the contact line. For a droplet containing suspended particles, this jet-like convective flow carries particles toward the contact line and deposits them on the surface, forming the so-called "coffee ring stain". In addition, we reported a simple polynomial correlation for dimensionless evaporation time as a function of initial contact angle of the pinned sessile droplet which agrees well with the previous experimental and numerical results.


Asunto(s)
Modelos Teóricos , Aire , Soluciones/química , Temperatura
19.
Anal Chem ; 86(2): 1061-6, 2014 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-24393015

RESUMEN

A lithography-free, low-cost, free-surface millifluidic device is reported using discrete liquid interfaces for capturing and detecting gas-phase analyte molecules at low partial pressures out of a gas flow of time-varying composition. The architecture, based on segmented flow, consists of alternating regions of liquid and gas wherein the liquid regions contain surface-enhanced Raman spectroscopy (SERS)-active silver nanoparticles, while the gas regions contain trace quantities of vapor-phase analyte, thereby controlling and optimizing transport and mixing of the gas-phase analyte with the liquid phase. Once absorbed in the liquid phase, the entrained analyte molecules induce aggregation of the aqueous silver nanoparticles. The resulting aggregates consisting of nanoparticles and adsorbed analyte molecules produce intense SERS spectra that reliably identify the absorbed analyte in real time. The approach can be used to determine the time-variable trace chemical composition of a gas stream with applications in, for example, environmental monitoring and online industrial process monitoring, or as a SERS-based detector following gas chromatographic separation. The operation of the system is demonstrated using 4-aminobenzenethiol vapor at 750 ppb, and the detection response time is <2 min.


Asunto(s)
Contaminantes Atmosféricos/análisis , Técnicas Analíticas Microfluídicas , Espectrometría Raman/métodos , Ácidos Sulfanílicos/análisis , Adsorción , Floculación , Gases , Humanos , Límite de Detección , Nanopartículas del Metal/química , Plata/química , Soluciones , Propiedades de Superficie , Factores de Tiempo , Volatilización
20.
Langmuir ; 29(44): 13614-23, 2013 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-24083574

RESUMEN

The aggregation kinetics of silver nanoparticles in sessile droplets were investigated both experimentally and through numerical simulations as a function of temperature gradient and evaporation rate, in order to determine the hydrodynamic and aggregation parameters that lead to optimal surface-enhanced Raman spectroscopic (SERS) detection. Thermal gradients promote effective stirring within the droplet. The aggregation reaction ceases when the solvent evaporates forming a circular stain consisting of a high concentration of silver nanoparticle aggregates, which can be interrogated by SERS leading to analyte detection and identification. We introduce the aggregation parameter, Γa ≡ τ(evap)/τ(a), which is the ratio of the evaporation to the aggregation time scales. For a well-stirred droplet, the optimal condition for SERS detection was found to be Γ(a,opt) = kc(NP)τ(evap) ≈ 0.3, which is a product of the dimerization rate constant (k), the concentration of nanoparticles (cNP), and the droplet evaporation time (τ(evap)). Near maximal signal (over 50% of maximum value) is observed over a wide range of aggregation parameters 0.05 < Γa < 1.25, which also defines the time window during which trace analytes can be easily measured. The results of the simulation were in very good agreement with experimentally acquired SERS spectra using gas-phase 1,4-benzenedithiol as a model analyte.


Asunto(s)
Nanopartículas del Metal/química , Plata/química , Temperatura , Hidrodinámica , Cinética , Espectrometría Raman , Compuestos de Sulfhidrilo/análisis , Compuestos de Sulfhidrilo/química , Propiedades de Superficie