Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Foot Ankle Int ; 33(3): 213-9, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22734283

RESUMEN

BACKGROUND: Florid infection and osteomyelitis of the forefoot in patients with diabetic neuropathy often requires minor amputation, with risk of subsequent reulceration, reamputation, and patient dissatisfaction. We investigated use of an antibiotic-impregnated cement spacer (ACS) to release antibiotic locally to resolve residual infection and to fill the cavity created by debridement. METHODS: We report 23 cases of osteomyelitis and associated severe infection of forefoot joints in 20 consecutive patients, age 60.3 +/- 13.4 years. Antibiotic-impregnated cement, extensive meticulous debridement, and ACS placement to fill the gap were employed in all cases. Deep cultures were taken routinely. Fixation with Kirschner wires was used as necessary. Mean followup was 21.2 +/- 10.2 months. A successful result was resolution of infection and wound healing to full skin closure without amputation. RESULTS: Of 23 cases, 21 (91.3%) healed and two required toe amputation. ACS was left permanently in 10 patients, removed with arthrodesis in six, and removed without arthrodesis in five. One patient recovered but subsequently underwent transtibial amputation due to infection of a different site. CONCLUSION: Severe infection associated with osteomyelitis of the foot in diabetic patients was successfully treated with extensive debridement and use of ACS, which filled the void created by debridement. Amputation was avoided in most patients. This procedure allowed extensive debridement through filling large voids with ACS, with prolonged antibiotic release.


Asunto(s)
Antibacterianos/administración & dosificación , Cementos para Huesos , Pie Diabético/terapia , Osteomielitis/terapia , Prótesis e Implantes , Terapia Recuperativa , Amputación Quirúrgica , Artrodesis , Artroplastia , Desbridamiento , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Aparatos Ortopédicos , Estudios Retrospectivos , Cicatrización de Heridas
4.
Foot Ankle Int ; 23(5): 400-5, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12043983

RESUMEN

Second metatarsal osteotomies (30 degrees angle to shaft) were performed in 40 sawbones with: 1. head shifted proximally 5 mm; 2. head shifted proximally 10 mm; 3. 5-mm slice resected and head shifted proximally 5 mm; or 4. 5-mm dorsally based wedge resected and head shifted proximally 5 mm. Bone slice resection resulted in shortening (16.4+/-1.7 mm) and mild plantar displacement of the head (3.5+/-0.8 mm). Bone wedge excision resulted in moderate shortening (7.8+/-0.9 mm) and essentially no plantar displacement of the head (0.8+/-1.4 mm).


Asunto(s)
Huesos Metatarsianos/cirugía , Modelos Anatómicos , Osteotomía/métodos , Humanos
5.
Foot Ankle Int ; 23(2): 97-101, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11858342

RESUMEN

Arthrodesis of the first metatarsophalangeal joint of 21 matched pairs of cadaver toes was performed in order to compare the strength of three methods of internal fixation: 1. two crossed cannulated screws, 2. a dorsal plate with an oblique 0.062 K-wire, and 3. two compression staples with an oblique 0.062 K-wire. Biomechanical testing with plantar force was carried out, and gapping across the fusion site was measured. Stiffness, load to 1-mm displacement, and force to failure was determined for each specimen. Both the plate and screw constructs were statistically stronger in force to failure and initial stiffness than the compression construct. Compression staples have an advantage in their ease of insertion and theoretical continuous compressive force across an arthrodesis site, but should be supplemented with a cast or other external immobilization until union is achieved.


Asunto(s)
Artrodesis/instrumentación , Fenómenos Biomecánicos , Articulación Metatarsofalángica/cirugía , Artrodesis/métodos , Placas Óseas , Tornillos Óseos , Cadáver , Seguridad de Equipos , Humanos , Fijadores Internos , Probabilidad , Distribución Aleatoria , Sensibilidad y Especificidad , Estrés Mecánico , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...