Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
PLoS One ; 12(2): e0171272, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28170419

RESUMEN

Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.


Asunto(s)
Pruebas de Coagulación Sanguínea , Cromatografía Líquida de Alta Presión , Inhibidores del Factor Xa/farmacocinética , Rivaroxabán/farmacocinética , Espectrometría de Masas en Tándem , Monitoreo de Drogas , Inhibidores del Factor Xa/uso terapéutico , Humanos , Reproducibilidad de los Resultados , Rivaroxabán/uso terapéutico , Sensibilidad y Especificidad
2.
Einstein (Sao Paulo) ; 14(3): 366-373, 2016.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-27759825

RESUMEN

OBJECTIVE:: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. METHODS:: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. RESULTS:: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. CONCLUSION:: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones. OBJETIVO:: Discutir as melhorias técnicas no diagnóstico e no acompanhamento laboratorial de hemoglobinúria paroxística noturna para a validação da técnica de citometria de fluxo de alta sensibilidade. MÉTODOS:: Estudo retrospectivo, que envolveu a análise de dados laboratoriais de 745 pacientes com hipótese diagnóstica e/ou acompanhamento de hemoglobinúria paroxística noturna por citometria de fluxo. RESULTADOS:: Os avanços técnicos não só reduziram o custo do ensaio, mas também melhoraram a identificação e a resolução da citometria de fluxo para a detecção de clone hemoglobinúria paroxística noturna. CONCLUSÃO:: A citometria de fluxo de alta sensibilidade possibilitou a identificação do tipo e do tamanho de clone de hemoglobinúria paroxística noturna, especialmente em amostras com pequeno clone.


Asunto(s)
Citometría de Flujo/métodos , Hemoglobinuria Paroxística/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales/sangre , Antígenos CD/sangre , Niño , Preescolar , Femenino , Citometría de Flujo/economía , Citometría de Flujo/instrumentación , Citometría de Flujo/normas , Hemoglobinuria Paroxística/sangre , Humanos , Lactante , Persona de Mediana Edad , Mejoramiento de la Calidad/economía , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
3.
Einstein (Säo Paulo) ; 14(3): 366-373, July-Sept. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-796970

RESUMEN

ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones.


RESUMO Objetivo: Discutir as melhorias técnicas no diagnóstico e no acompanhamento laboratorial de hemoglobinúria paroxística noturna para a validação da técnica de citometria de fluxo de alta sensibilidade. Métodos: Estudo retrospectivo, que envolveu a análise de dados laboratoriais de 745 pacientes com hipótese diagnóstica e/ou acompanhamento de hemoglobinúria paroxística noturna por citometria de fluxo. Resultados: Os avanços técnicos não só reduziram o custo do ensaio, mas também melhoraram a identificação e a resolução da citometria de fluxo para a detecção de clone hemoglobinúria paroxística noturna. Conclusão: A citometria de fluxo de alta sensibilidade possibilitou a identificação do tipo e do tamanho de clone de hemoglobinúria paroxística noturna, especialmente em amostras com pequeno clone.


Asunto(s)
Humanos , Femenino , Lactante , Preescolar , Niño , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Citometría de Flujo/métodos , Hemoglobinuria Paroxística/diagnóstico , Antígenos CD/sangre , Estudios Retrospectivos , Sensibilidad y Especificidad , Mejoramiento de la Calidad/economía , Citometría de Flujo/economía , Citometría de Flujo/instrumentación , Citometría de Flujo/normas , Hemoglobinuria Paroxística/sangre , Anticuerpos Monoclonales/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA