Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Appl Radiat Isot ; 205: 111181, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38244325

RESUMEN

PURPOSE: Body composition analysis using computed tomography (CT) is proposed as a predictor of cancer mortality. An association between subcutaneous adipose tissue radiodensity (SATr) and cancer-specific mortality was established, while gender effects and equipment bias were estimated. METHODS: 7,475 CT studies were selected from 17 cohorts containing CT images of untreated cancer patients who underwent follow-up for a period of 2.1-118.8 months. SATr measures were collected from published data (n = 6,718) or calculated according to CT images using a deep-learning network (n = 757). The association between SATr and mortality was ascertained for each cohort and gender using the p-value from either logistic regression or ROC analysis. The Kruskal-Wallis test was used to analyze differences between gender distributions, and automatic segmentation was evaluated using the Dice score and five-point Likert quality scale. Gender effect, scanner bias and changes in the Hounsfield unit (HU) to detect hazards were also estimated. RESULTS: Higher SATr was associated with mortality in eight cancer types (p < 0.05). Automatic segmentation produced a score of 0.949 while the quality scale measurement was good to excellent. The extent of gender effect was 5.2 HU while the scanner bias was 10.3 HU. The minimum proposed HU change to detect a patient at risk of death was between 5.6 and 8.3 HU. CONCLUSIONS: CT imaging provides valuable assessments of body composition as part of the staging process for several cancer types, saving both time and cost. Gender specific scales and scanner bias adjustments should be carried out to successfully implement SATr measures in clinical practice.


Asunto(s)
Neoplasias , Humanos , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Grasa Subcutánea/diagnóstico por imagen , Tejido Adiposo
2.
J Nucl Med Technol ; 47(1): 47-54, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30076252

RESUMEN

Oncologic 18F-FDG PET/CT acquisition and reconstruction protocols need to be optimized for both quantitative and detection tasks. To date, most studies have focused on either quantification or noise, leading to quantitative harmonization guidelines or appropriate noise levels. We developed and evaluated protocols that provide harmonized quantitation with optimal amounts of noise as a function of acquisition parameters and body mass. Methods: Multiple image acquisitions (n = 17) of the International Electrotechnical Commission/National Electrical Manufacturers Association PET image-quality phantom were performed with variable counting statistics. Phantom images were reconstructed with 3-dimensional ordered-subset expectation maximization (OSEM3D) and point-spread function (PSF) for harmonized quantification of the contrast recovery coefficient of the maximum pixel value (CRC max ). The lowest counting statistics that resulted in compliance with European Association of Nuclear Medicine recommendations for CRC max and CRC max variability were used as optimization metrics. Image noise in the liver of 48 typical oncologic 18F-FDG PET/CT studies was analyzed with OSEM3D and PSF harmonized reconstructions. We also evaluated 164 additional 18F-FDG PET/CT reconstructed list-mode images to derive analytic expressions that predict image quality and noise variability. Phantom-to-subject translational analysis was used to derive optimized acquisition and reconstruction protocols. Results: For harmonized quantitation levels, PSF reconstructions yielded decreased noise and lower CRC max variability than regular OSEM3D reconstructions, suggesting they could enable a decreased activity regimen for matched performance. Conclusion: PSF reconstruction with a 7-mm postprocessing filter can provide harmonized quantification performance and acceptable image noise levels with injected activity, duration, and mass settings using a 260 MBq⋅s/kg acquisition parameter at scan time. Similarly, OSEM3D with a 5-mm postprocessing filter can provide similar performance with 401 MBq⋅s/kg.


Asunto(s)
Fluorodesoxiglucosa F18 , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Dosis de Radiación , Relación Señal-Ruido , Estudios de Factibilidad , Humanos , Fantasmas de Imagen
3.
Med Phys ; 43(2): 930-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26843253

RESUMEN

PURPOSE: This paper describes a method to achieve consistent clinical image quality in (18)F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. METHODS: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. RESULTS: The adoption of different schemes for three body mass ranges (<60 kg, 60-90 kg, >90 kg) allows improved image quality with both point spread function and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. CONCLUSIONS: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations.


Asunto(s)
Fluorodesoxiglucosa F18 , Imagenología Tridimensional/métodos , Imagen Multimodal , Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Dosis de Radiación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA