Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Oncol ; 14: 1346407, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38841160

RESUMEN

Hepatocellular Carcinoma (HCC) is one of the most common malignant neoplasms. With the advancement of technology, the precision of radiotherapy (RT) for HCC has considerably increased, and it is an indispensable modality in the comprehensive management of HCC. Some RT techniques increase the radiation dose to HCC, which decreases the radiation dose delivered to the surrounding normal liver tissue. This approach significantly improves the efficacy of HCC treatment and reduces the incidence of Radiation-induced Liver Disease (RILD). Clear imaging and precise determination of the Gross Target Volume (GTV) are prerequisites of precise RT of HCC. The main hindrances in determining the HCC GTV include indistinct tumor boundaries on imaging and the impact on respiratory motion. The integration of multimodal imaging, four-dimensional imaging, and artificial intelligence (AI) techniques can help overcome challenges for HCC GTV. In this article, the advancements in medical imaging and precise determination for HCC GTV have been reviewed, providing a framework for the precise RT of HCC.

2.
Front Oncol ; 14: 1338225, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38779095

RESUMEN

Brain metastases (BMs) are the most prevalent intracranial malignant tumors in adults and are the leading cause of mortality attributed to malignant brain diseases. Radiotherapy (RT) plays a critical role in the treatment of BMs, with local RT techniques such as stereotactic radiosurgery (SRS)/stereotactic body radiotherapy (SBRT) showing remarkable therapeutic effectiveness. The precise determination of gross tumor target volume (GTV) is crucial for ensuring the effectiveness of SRS/SBRT. Multimodal imaging techniques such as CT, MRI, and PET are extensively used for the diagnosis of BMs and GTV determination. With the development of functional imaging and artificial intelligence (AI) technology, there are more innovative ways to determine GTV for BMs, which significantly improve the accuracy and efficiency of the determination. This article provides an overview of the progress in GTV determination for RT in BMs.

3.
Radiother Oncol ; 197: 110330, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38768715

RESUMEN

BACKGROUND AND PURPOSE: To assess the variation of large-volume brain metastases (BMs) boundaries and shapes using enhanced magnetic resonance (MR) scanning with different delay times and to provide a basis for determining the gross tumor target volume (GTV) for radiotherapy of BMs. MATERIALS AND METHODS: We prospectively enrolled 155 patients initially diagnosed with BMs (561 lesions > 1 cm). Contrast-enhanced (CE) T1-weighted imaging scans were performed 1, 3, 5, 10, 18, and 20 min after gadolinium-based contrast agent injection and GTVs were determined as GTV-1min, GTV-3min, GTV-5min, GTV-10min, GTV-18min, and GTV-20min, respectively, which were subsequently fused in different phases. Fusion of the six GTVs was defined as GTV-total, which was set as the reference GTV. The volume, shape, and signal intensity of the GTVs and brain white matter (BWM) were compared at different delay times. RESULTS: GTV-3min, GTV-5min, GTV-10min, GTV-18min, and GTV-20min volumes increased by 2.2 %, 3.8 %, 6.5 %, 9.5 %, and 10.6 %, respectively (P < 0.05) compared with GTV-1min. Compared with GTV-total, GTV-1min, GTV-3min, GTV-5min, GTV-10min, GTV-18min, and GTV-20min volumes reduced by 25.4 %, 22.1 %, 18.7 %, 15.0 %, 11.2 %, and 10.3 %, respectively (P < 0.05). Compared with GTV-total, 29 (51.8 %) fused GTVs had a volume reduction rate < 5 %, 45 (80.4 %) had a Dice similarity coefficient > 0.95, and all contained GTV-10min, GTV-18min or GTV-20min. The signal intensity ratio between the GTV and BWM peaked at 5 min (0.351 ± 0.24). CONCLUSION: Enhanced MR scans with different delay times show significant differences in the boundaries and shapes of large-volume BMs, and time-delayed multi-phase CE scanning should be used in GTV determination, with time phases ≥ 10 min being mandatory.


Asunto(s)
Neoplasias Encefálicas , Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/patología , Femenino , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Masculino , Anciano , Estudios Prospectivos , Adulto , Carga Tumoral , Factores de Tiempo , Anciano de 80 o más Años
4.
Front Oncol ; 14: 1342669, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38327749

RESUMEN

Whole-brain radiotherapy (WBRT) plays an irreplaceable role in the treatment of brain metastases (BMs), but cognitive decline after WBRT seriously affects patients' quality of life. The development of cognitive dysfunction is closely related to hippocampal injury, but standardized criteria for predicting hippocampal injury and dose limits for hippocampal protection have not yet been developed. This review systematically reviews the clinical efficacy of hippocampal avoidance - WBRT (HA-WBRT), the controversy over dose limits, common methods and characteristics of hippocampal imaging and segmentation, differences in hippocampal protection by common radiotherapy (RT) techniques, and the application of artificial intelligence (AI) and radiomic techniques for hippocampal protection. In the future, the application of new techniques and methods can improve the consistency of hippocampal dose limit determination and the prediction of the occurrence of cognitive dysfunction in WBRT patients, avoiding the occurrence of cognitive dysfunction in patients and thus benefiting more patients with BMs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA