Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Invasive Cardiol ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38471151

RESUMEN

An 83-year-old man who had undergone coronary aorta bypass graft surgery 25 years ago required treatment for new-onset worsening angina.

2.
PLoS One ; 17(8): e0273157, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35976920

RESUMEN

BACKGROUND: A coronary bifurcation stenting is still a challenging issue due to frequent restenosis and stent thrombosis even with drug-eluting stents. The bifurcation angle (BA) between a main vessel and a side branch is one of the crucial determinants of coronary flow and shear stress that affect the plaque distribution. Previous bench and clinical studies have evaluated the impact of the BA between the proximal main vessel and the side branch (Angle A) and the BA between the distal main vessel and the side branch (Angle B) on the clinical outcomes of bifurcation stenting. However, the impact has not yet been fully elucidated due to a lack of statistical power or different manner of the assessment of BA. OBJECTIVES: To analyze the published studies on coronary artery BA, the modalities used for assessment, and the impact of BA on interventions and attempt to define the pre-procedural protocols. DATA SOURCES: A scoping review was performed using the Joanna Briggs Institute Methodology. A total of 52 relevant references were selected from PubMed, Cochrane Library, and CINAHL databases and categorized into three topic areas. RESULTS AND CONCLUSIONS: A wider Angle A is associated with the increased likelihood of carina shift and a wider Angle B, with that of side branch occlusion. A wider Angle B promotes stent malapposition and deformation in the side branch ostium and has been reported as an independent predictor of major adverse cardiac events after bifurcation stenting; however, improvement of the drug-eluting stent, refinement of the stenting technique, and accurate 3-dimensional assessment may attenuate the adverse clinical impact of a wider BA. IMPLICATIONS OF KEY FINDINGS: Assessment of the BA is necessary to predict the effect of bifurcation intervention procedure on the stent configuration and coronary flow at the bifurcated vessels. This will help to optimize stent selection and the stenting technique.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Aterosclerosis/patología , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos/efectos adversos , Corazón , Humanos , Stents/efectos adversos , Resultado del Tratamiento
4.
Clin Case Rep ; 9(7): e04217, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34257971

RESUMEN

We reported a case that the insertion of a 48-mm-long stent in a calcified coronary lesion after rotational atherectomy led to stent stacking and S-shaped flection, resulting in longitudinal coronary perforation without stent inflation. Its flexibility and length pose a possible risk of deformation inside the vessel during stent insertion.

5.
EuroIntervention ; 17(5): e425-e432, 2021 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-32657276

RESUMEN

BACKGROUND: Side branch (SB) dilation with an ultra-short balloon after main vessel (MV) stenting may minimise stent failure in coronary bifurcation lesions. AIMS: We sought to investigate the feasibility and efficacy of the Glider balloon (GB), a side branch (SB)-dedicated balloon 4 mm in length, in coronary bifurcation stenting. METHODS: In bench testing, stent configuration was examined with micro-focus computed tomography after crossover stenting followed by GB dilation or kissing balloon inflation (KBI). In the clinical study we performed GB dilatation after MV stenting for 207 lesions in 194 patients. Failure of the GB dilation and additional procedures due to inducible stent failure were investigated as well as adverse cardiac events at 1-year follow-up. RESULTS: In bench testing GB dilation maintained cross-sectional stent area without significant deformation and presented effective jailed strut removal in a high-angled bifurcation model. In the clinical study the cohort included left main, true bifurcation lesion, and two-stent treatment in 42.0%, 45.9%, and 14.0%, respectively. The proximal optimisation technique (POT) or POT-like inflation was performed in 82.1%. GB crossing failure, SB stenting due to dissection, and stent deformation requiring correction by KBI or MV dilation occurred in 8.7%, 1.4%, and 5.8%, respectively. Finally, simple GB dilation without KBI was completed in 91.8% for SB dilation. At one-year follow-up, target lesion revascularisation, cardiac death, myocardial infarction, and stent thrombosis were found in 7.2%, 2.1%, 2.1%, and 1.0%, respectively. CONCLUSIONS: Simple GB dilation after adequate expansion of the proximal MV stent provided acceptable acute and long-term results as an alternative to KBI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estudios Transversales , Estudios de Factibilidad , Humanos , Stents , Resultado del Tratamiento
6.
J Cardiol Cases ; 22(1): 40-43, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32636969

RESUMEN

A previous autopsy study has revealed that malapposed or protruded struts in the coronary bifurcation were a risk factor for very late stent thrombosis (VLST); however, a live clinical case has not yet been reported due to difficulty in observation at the VLST site. In this case, a 56-year-old male patient underwent a zotarolimus-eluting stent implantation in the proximal left anterior descending artery for acute myocardial infarction 3 years previously and had been treated with dual antiplatelet therapy. The patient experienced chest pain and suddenly collapsed due to acute coronary syndrome caused by a huge thrombus in the left main coronary bifurcation. After insertion of the intra-aortic balloon pump, kissing balloon inflation improved coronary flow and hemodynamics. Two weeks later, a 3-dimensional optical frequency domain imaging (3-D OFDI) revealed uncovered protruded struts on the ostium of the left circumflex artery (LCX). We removed the protruded struts using a double lumen catheter, for which the second wire was advanced to more distal cell along with the first wire located in the same LCX branch. 3-D OFDI clearly demonstrated that uncovered protruded struts at the LCX ostium were the cause of VLST and navigated optimal wiring with a double lumen catheter. Learning objective: Existence of protruded struts at the coronary bifurcated branch ostium is a risk factor for very late stent thrombosis. Three-dimensional optical frequency domain imaging clearly demonstrates the protruded strut configuration at the side branch of ostium and facilitates optimal guide wire re-crossing for kissing balloon inflation. Usage of double lumen catheter increases the possibility of optimal side branch wiring.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA