Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Virol ; 61(1): 113-7, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25034375

RESUMEN

BACKGROUND: BD Veritor™ System for Rapid Detection of Respiratory Syncytial Virus (RSV) is a new-generation lateral flow immunochromatographic assay for objective detection of RSV in respiratory specimens from children. OBJECTIVE: To evaluate the performance of BD Veritor™ System for Rapid Detection of RSV in respiratory specimens collected from pediatric patients. STUDY DESIGN: A prospective, multicenter clinical trial was undertaken at five study sites representing geographically diverse regions of the U.S. to assess the performance of the BD Veritor™ System for Rapid Detection of RSV in comparison to R-mix shell vial culture and ProFlu+ reverse transcription-PCR assay (Gen-Probe/Prodesse). RESULTS: 440 nasopharyngeal washes/aspirates (NPW/A) and 706 nasopharyngeal swab (NPS) specimens from U.S. subjects<20 years of age were collected and tested using the BD Veritor™ System and compared with shell vial culture and real-time RT-PCR results. Analysis of the data indicates the overall sensitivity and specificity for BD Veritor™ System for all sample types combined was 90% and 97.0% versus shell vial culture and 75.5% and 98.7% versus RT-PCR respectively. CONCLUSION: Overall, the BD Veritor™ System for the Rapid Detection of RSV performed well when compared to both viral cell culture and RT-PCR in children.


Asunto(s)
Cromatografía de Afinidad/métodos , Pruebas Diagnósticas de Rutina/métodos , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Virus Sincitial Respiratorio Humano/aislamiento & purificación , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Sensibilidad y Especificidad , Estados Unidos , Cultivo de Virus/métodos
2.
J Clin Virol ; 59(3): 172-6, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24440176

RESUMEN

BACKGROUND: Rapid HIV test devices are widely used throughout the world and are important as diagnostic tools with relatively high sensitivity and specificity. Loss of HIV specific antibodies in late-stage AIDS patients has previously been reported in patients with advanced disease (i.e., AIDS). OBJECTIVE: To study rate of antibody loss that may lead to false negative HIV-antibodies results in children and adolescents who received long term antiretroviral (ARV) treatment with persistently undetectable viral loads. STUDY DESIGN: Five FDA approved rapid HIV test kits including Trinity Uni-Gold Recombigen HIV-1, OraQuick Advance HIV-1/2, Reveal G3 HIV-1, Clearview STAT-PAK HIV-1/2, and Clearview COMPLETE HIV-1/2 were used to test 98 stored samples from 27 patients. Samples were tested at baseline and at least twice in 6-14 years post initiation of ARV treatment and full viral load suppression. RESULTS: Of the 403 tests, 43 (10.7%) were found to be false-negative using rapid HIV kits. Loss of positivity was correlated with decrease of HIV antibody titer. CONCLUSIONS: There is a slow but persistent loss of HIV specific antibodies in highly suppressed HIV infected children and adolescents that may lead to false-negative results in rapid HIV antibody tests. The temporal loss of signal is dependent on the baseline level of antibodies and the type of HIV rapid test kit used.


Asunto(s)
Reacciones Falso Negativas , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/diagnóstico , Infecciones por VIH/epidemiología , Adolescente , Antirretrovirales/uso terapéutico , Niño , Estudios de Cohortes , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/inmunología , Humanos , Técnicas para Inmunoenzimas , Juego de Reactivos para Diagnóstico , Virología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...