1.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36121045

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Implantación de Prótesis , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Ataque Isquémico Transitorio/etiología , Implantación de Prótesis/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
3.
Am Heart J ; 236: 37-48, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33636137

RESUMEN

BACKGROUND: Minorities and women are underrepresented in cardiovascular research. Whether their higher enrollment can be predicted or influences research site performance is unclear. METHODS: We evaluated 104 sites that enrolled 4,184 patients in the U.S. Platinum Diversity (PD) and Promus Element Plus (PE Plus) studies (2012 to 2016). Research sites were ranked from lowest to highest minority and female enrollment, respectively. United States Census Bureau division and core-based statistical area (CBSA) populations were determined for each site and the following study performance metrics compared across quartiles of minority and female enrollment, respectively: (1) study subject enrollment rate (SER), (2) time to first patient enrolled, (3) rate of follow-up visits not done, (4) rate of follow-up visits out of window, and (5) protocol deviation rate (PDR). Multivariable regression was used to predict SER and PDR. RESULTS: Minority enrollment varied by region (P = .025) and population (P = .024) with highest recruitment noted in the Pacific, West South Central, South Atlantic, Mid-Atlantic and East North Central divisions. Female enrollment bore no relationship to region (P = .67) or population (P = .40). Median SER was similar in sites withi the highest vs lowest quartile of minority enrollment (SER of 4 vs 5 patients per month, respectively, P =0.78) and highest vs. lowest female enrollment (SER of 4 vs 4, respectively, P = .21). Median PDR was lower in sites within the highest vs lowest minority enrollment (0.23 vs 0.50 PDs per patient per month, respectively, P = .01) and highest vs. lowest female enrollment (0.28 vs. 0.37 PDs per patient per month, respectively, P = .04). However, this relationship did not persist after multivariable adjustment. All other site performance metrics were comparable across quartiles of minority and female enrollment. CONCLUSIONS: Minority, but not female enrollment, correlated with research site geographic region and surrounding population. High enrollment of minorities and women did not influence study performance metrics. These findings help inform future strategies aimed at increasing clinical trial diversity. TRIAL REGISTRATION: The PD and PE Plus studies are registered at www.clinicaltrials.gov under identifiers NCT02240810 and NCT01589978, respectively. KEY POINTS: Question: Does the enrollment of more Blacks, Hispanics and women in US cardiovascular research studies influence the overall rate of study subject enrollment and/or other key study site performance metrics and can diverse enrollment be predicted? FINDINGS: In this pooled analysis of 104 sites that enrolled 4,184 patients in the Platinum Diversity and Promus Element Plus Post-Approval Studies, we found that the enrollment of higher proportions of underrepresented minorities and women was univariately associated with lower protocol deviation rates while having no effect on other site performance metrics. A site's geographic location and surrounding population predicted minority, but not female enrollment. Meaning: These findings suggest that cardiovascular research subject diversity may be predicted from site characteristics and enhanced without compromising key study performance metrics. These insights help inform future strategies aimed at improving clinical trial diversity.


Asunto(s)
Enfermedad de la Arteria Coronaria , Salud de las Minorías/estadística & datos numéricos , Selección de Paciente , Intervención Coronaria Percutánea , Salud de la Mujer/estadística & datos numéricos , Ensayos Clínicos como Asunto/métodos , Ensayos Clínicos como Asunto/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Femenino , Accesibilidad a los Servicios de Salud , Humanos , Masculino , Persona de Mediana Edad , Grupos Minoritarios/clasificación , Grupos Minoritarios/estadística & datos numéricos , Evaluación de Resultado en la Atención de Salud , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Sistema de Registros/estadística & datos numéricos , Estados Unidos/epidemiología
4.
J Interv Cardiol ; 2020: 3070427, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32518532

RESUMEN

RESPOND is a prospective, single-arm study enrolling 1014 transcatheter aortic valve replacement (TAVR) patients. The objective of this analysis is to assess the impact of cerebral embolic protection (CEP) devices and prosthetic valve repositioning on the risk of neurologic complications in patients treated with the fully repositionable Lotus Valve in the RESPOND postmarket study. Valve repositioning and CEP use were at the operators' discretion. Stroke events were adjudicated by an independent medical reviewer. This analysis assessed the baseline differences among patients according to CEP use and valve repositioning and evaluated the neurological complications at 72 hours after TAVR, hospital discharge, and 30-day follow-up. A multivariate analysis was performed to identify the potential predictors of stroke. Of the 996 patients implanted with the Lotus Valve (mean age: 80.8 years, 50.8% female, STS score 6.0 ± 6.9), 92 cases (9.2%) used CEP. The overall rate of acute stroke/transient ischemic attack (TIA) was 3.0% at 72 hours after TAVR. The 72-hour stroke/TIA rate was 1.1% in patients who had CEP and 3.2% in those who did not. Use of CEP was associated with a 2.1% absolute reduction in the risk of acute neurological events (relative risk reduction: 65.6%), although the difference was not statistically significant (p=0.51). Repositioning of the Lotus Valve occurred in 313/996 procedures (31.4%). The 72-hour rate of stroke/TIA was similar in patients who had valve repositioning (2.9%) compared with those who did not (3.1%; p=0.86). The selective use of a CEP device in the RESPOND study was associated with a nonsignificantly lower risk for stroke within 72 hours. The use of the repositioning feature of the Lotus Valve did not increase the stroke risk.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Dispositivos de Protección Embólica , Embolia Intracraneal , Complicaciones Posoperatorias , Ajuste de Riesgo/métodos , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Embolia Intracraneal/diagnóstico , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
5.
Heart Lung Circ ; 29(6): 883-893, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31564511

RESUMEN

BACKGROUND: To compare computed tomography coronary angiography (CTCA) with intravascular ultrasound (IVUS) in quantitative and qualitative plaque assessment. METHODS: Patients who underwent IVUS and CTCA within 3 months for suspected coronary artery disease were retrospectively studied. Plaque volumes on CTCA were quantified manually and with automated-software and were compared to IVUS. High-risk plaque features were compared between CTCA and IVUS. RESULTS: There were 769 slices in 32 vessels (27 patients). Manual plaque quantification on CTCA was comparable to IVUS per slice (mean difference of 0.06±0.07, p=0.44; Bland-Altman 95% limits of agreement -2.19-2.08 mm3, bias of -0.06mm3) and per vessel (3.1mm3 ± -2.85mm3, p=0.92). In contrast, there was significant difference between automated-software and IVUS per slice (2.3±0.09mm3, p<0.001; 95% LoA -6.78 to 2.25mm3, bias of -2.2mm3) and per vessel (33.04±10.3 mm3, p<0.01). The sensitivity, specificity, positive and negative predictive value of CTCA to detect plaques that had features of echo-attenuation on IVUS was 93.3%, 99.6%, 93.3% and 99.6% respectively. The association of ≥2 high-risk plaque features on CTCA with echo attenuation (EA) plaque features on IVUS was excellent (86.7%, 99.6%, 92.9% and 99.2%). In comparison, the association of high-risk plaque features on CTCA and plaques with echo-lucency on IVUS was only modest. CONCLUSION: Plaque volume quantification by manual CTCA method is accurate when compared to IVUS. The presence of at least two high-risk plaque features on CTCA is associated with plaque features of echo attenuation on IVUS.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico , Ultrasonografía Intervencional/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
6.
J Am Heart Assoc ; 8(21): e012594, 2019 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-31640455

RESUMEN

Background As transcatheter aortic valve replacement expands to younger and/or lower risk patients, the long-term consequences of permanent pacemaker implantation are a concern. Pacemaker dependency and impact have not been methodically assessed in transcatheter aortic valve replacement trials. We report the incidence and predictors of pacemaker implantation and pacemaker dependency after transcatheter aortic valve replacement with the Lotus valve. Methods and Results A total of 912 patients with high/extreme surgical risk and symptomatic aortic stenosis were randomized 2:1 (Lotus:CoreValve) in REPRISE III (The Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial. Systematic assessment of pacemaker dependency was pre-specified in the trial design. Pacemaker implantation within 30 days was more frequent with Lotus than CoreValve. By multivariable analysis, predictors of pacemaker implantation included baseline right bundle branch block and depth of implantation; diabetes mellitus was also a predictor with Lotus. No association between new pacemaker implantation and clinical outcomes was found. Pacemaker dependency was dynamic (30 days: 43%; 1 year: 50%) and not consistent for individual patients over time. Predictors of pacemaker dependency at 30 days included baseline right bundle branch block, female sex, and depth of implantation. No differences in mortality or stroke were found between patients who were pacemaker dependent or not at 30 days. Rehospitalization was higher in patients who were not pacemaker dependent versus patients without a pacemaker or those who were dependent. Conclusions Pacemaker implantation was not associated with adverse clinical outcomes. Most patients with a new pacemaker at 30 days were not dependent at 1 year. Mortality and stroke were similar between patients with or without pacemaker dependency and patients without a pacemaker. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Marcapaso Artificial , Complicaciones Posoperatorias/terapia , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino
7.
JACC Heart Fail ; 7(11): 945-955, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31521683

RESUMEN

OBJECTIVES: This study sought to evaluate the effects of the Carillon device on mitral regurgitation severity and left ventricular remodeling. BACKGROUND: Functional mitral regurgitation (FMR) complicates heart failure with reduced ejection fraction and is associated with a poor prognosis. METHODS: In this blinded, randomized, proof-of-concept, sham-controlled trial, 120 patients receiving optimal heart failure medical therapy were assigned to a coronary sinus-based mitral annular reduction approach for FMR or sham. The pre-specified primary endpoint was change in mitral regurgitant volume at 12 months, measured by quantitative echocardiography according to an intention-to-treat analysis. RESULTS: Patients (69.8 ± 9.5 years of age) were randomized to either the treatment (n = 87) or the sham-controlled (n = 33) arm. There were no significant differences in baseline characteristics between the groups. In the treatment group, 73 of 87 (84%) had the device implanted. The primary endpoint was met, with a statistically significant reduction in mitral regurgitant volume in the treatment group compared to the control group (decrease of 7.1 ml/beat [95% confidence interval [CI]: -11.7 to -2.5] vs. an increase of 3.3 ml/beat [95% CI: -6.0 to 12.6], respectively; p = 0.049). Additionally, there was a significant reduction in left ventricular volumes in patients receiving the device versus those in the control group (left ventricular end-diastolic volume decrease of 10.4 ml [95% CI: -18.5 to -2.4] vs. an increase of 6.5 ml [95% CI: -5.1 to 18.2]; p = 0.03 and left ventricular end-systolic volume decrease of 6.2 ml [95% CI: -12.8 to 0.4] vs. an increase of 6.1 ml [95% CI: -1.42 to 13.6]; p = 0.04). CONCLUSIONS: The Carillon device significantly reduced mitral regurgitant volume and left ventricular volumes in symptomatic patients with functional mitral regurgitation receiving optimal medical therapy. (Carillon Mitral Contour System for Reducing Functional Mitral Regurgitation [REDUCE FMR]; NCT02325830).


Asunto(s)
Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anuloplastia de la Válvula Mitral/métodos , Prueba de Estudio Conceptual , Índice de Severidad de la Enfermedad , Remodelación Ventricular
8.
Circ Cardiovasc Interv ; 12(9): e008152, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31451014

RESUMEN

BACKGROUND: The thin-strut SYNERGY stent has an abluminal everolimus-eluting bioabsorbable polymer coating designed to facilitate vascular healing and reduce risk of stent thrombosis. In the multicenter, randomized EVOLVE II trial (The EVOLVE II Clinical Trial to Assess the SYNERGY Stent System for the Treatment of Atherosclerotic Lesion[s]), SYNERGY was noninferior to the durable polymer PROMUS Element Plus everolimus-eluting stent for the primary end point of 1-year target lesion failure. Longer-term clinical follow-up will support the relative efficacy and safety of SYNERGY. METHODS: Patients with ≤3 native coronary lesions (reference vessel diameter ≥2.25-≤4.00 mm; length ≤34 mm) in ≤2 major epicardial vessels were randomized 1:1 to SYNERGY (N=838) or PROMUS Element Plus (N=846). EVOLVE II included a Diabetes substudy which pooled patients with diabetes mellitus from the randomized controlled trial (n=263) and from a sequential, single-arm substudy (N=203). RESULTS: The 5-year target lesion failure rate was 14.3% for SYNERGY and 14.2% for PROMUS Element Plus (P=0.91). Landmark analysis demonstrated similar rates of target lesion failure from discharge to 1-year (P=0.90) and from 1 to 5 years (P=0.94). Definite/probable stent thrombosis was infrequent in both arms (SYNERGY 0.7% versus PROMUS Element Plus 0.9%; P=0.75). There were no significant differences in the rates of cardiac death, myocardial infarction, or revascularization. Among patients with diabetes mellitus, the target lesion failure rate to 1-year was noninferior to a prespecified performance goal and to 5 years was 17.0%. CONCLUSIONS: SYNERGY demonstrated comparable outcomes to PROMUS Element Plus, with low rates of stent thrombosis and adverse events through 5 years of follow-up. Five-year clinical outcomes were favorable in patients with diabetes mellitus. These data support the long-term safety and effectiveness of SYNERGY in a broad range of patients. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01665053.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
9.
Circ Cardiovasc Interv ; 12(5): e007448, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31084239

RESUMEN

Rotational atherectomy (RA) is an established tool in interventional cardiology for treatment of calcified coronary lesions. Over 3 decades of clinical experience and research, techniques have matured and outcomes have improved. Heterogeneity exists, however, in RA utilization and technique. We assembled a group of experienced RA operators and device experts to summarize and critique key elements of contemporary RA technique, to identify areas of consensus and controversy, and to offer recommendations for optimal performance for the practicing interventional cardiologist. Evolution in RA strategy toward a focus on lesion modification to facilitate balloon angioplasty and stenting has underpinned major advances in procedural safety, including opportunity to use smaller caliber equipment and radial access. Optimal technique and improved safety have permitted exploratory use of RA for different lesion types and reevaluation of procedural requirements, including flush solution composition and transvenous pacing. Preparedness to manage complications remains paramount and recommendations for operators and institutions are outlined.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Calcificación Vascular/terapia , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/mortalidad , Aterectomía Coronaria/efectos adversos , Aterectomía Coronaria/instrumentación , Aterectomía Coronaria/mortalidad , Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Humanos , Selección de Paciente , Factores de Riesgo , Stents , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/mortalidad
10.
Am J Cardiol ; 123(11): 1765-1771, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30926144

RESUMEN

PROMUS Element (PE) Plus post-approval study was a large prospective, observational, all-comers study designed to evaluate the safety and performance of a thin-strut platinum chromium everolimus-eluting PE Plus stent in everyday clinical practice. A total of 2,683 "real-world" patients with limited clinical or anatomic exclusion criteria were enrolled at 52 clinical sites in the United States. The study met its primary end point of 12-month cardiac death or myocardial infarction (CD/MI) compared with a prespecified performance goal (p <0.0001). Five-year clinical outcomes were evaluated in overall PE Plus post-approval study patients and high-risk subgroups. During the 5-year follow-up period, CD/MI and stent thrombosis related to the PE Plus stent occurred in 9% and 2.2% overall patients, respectively. The reported all-cause mortality rate was 15%, with 7% classified as cardiac-related. A total of 18% patients underwent target vessel revascularization, and 11% were reported as target lesion revascularization. The rates of PE Plus stent-related CD/MI remained low in patients with medically treated diabetes (13%), small vessels (9%), and long stents (10%). PE Plus stent-related thrombosis through 5 years in patients with diabetes, small vessels and long stents was 4.2%, 2.2%, and 2.6%, respectively. The occurrence of target lesion revascularization was numerically higher in patients with diabetes (16%) and long lesions (18%) than the small vessels subgroup (11%). In conclusion, the final 5-year results establish the long-term safety and efficacy of the PE Plus stent in a broad, unselected patient population representative of "real-world" clinical practice.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Cromo , Terapia Combinada , Femenino , Humanos , Masculino , Platino (Metal) , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
11.
Catheter Cardiovasc Interv ; 93(6): 1116-1123, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30773838

RESUMEN

AIMS: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry. METHODS AND RESULTS: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm2 to 1.7 ± 0.4 cm2 (P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM-naïve patients was 22.2% (6/27). CONCLUSIONS: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Europa (Continente) , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , América Latina , Masculino , Nueva Zelanda , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento
12.
JAMA Cardiol ; 4(3): 223-229, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30810703

RESUMEN

Importance: To our knowledge, REPRISE III is the first large randomized comparison of 2 different transcatheter aortic valve replacement platforms: the mechanically expanded Lotus valve (Boston Scientific) and self-expanding CoreValve (Medtronic). Objective: To evaluate outcomes of Lotus vs CoreValve after 2 years. Design, Setting, and Participants: A total of 912 patients with high/extreme risk and severe, symptomatic aortic stenosis enrolled between September 22, 2014, and December 24, 2015, were randomized 2:1 to receive Lotus (607 [66.6%]) or CoreValve (305 [33.4%] at 55 centers in North America, Europe, and Australia. The first 2-year visit occurred on October 17, 2016, and the last was conducted on April 12, 2018. Clinical and echocardiographic assessments are complete through 2 years and will continue annually through 5 years. Main Outcomes and Measures: All-cause mortality and all-cause mortality or disabling stroke at 2 years. Other clinical factors included overall stroke, disabling stroke, repeated procedures, rehospitalization, valve thrombosis, and pacemaker implantation. Echocardiographic analyses included effective orifice area, mean gradient, and paravalvular leaks (PVLs). Results: Of 912 participants, the mean (SD) age was 82.8 (7.3) years, 465 (51%) were women, and the mean (SD) Society of Thoracic Surgeons predicted risk of mortality was 6.8% (4.0%). At 2 years, all-cause death was 21.3% with Lotus vs 22.5% with CoreValve (hazard ratio [HR], 0.94; 95% CI, 0.69-1.26; P = .67) and all-cause mortality or disabling stroke was 22.8% with Lotus and 27.0% with CoreValve (HR, 0.81; 95% CI, 0.61-1.07; P = .14). Overall stroke was 8.4% vs 11.4% (HR, 0.75; 95% CI, 0.48-1.17; P = .21); disabling stroke was more frequent with CoreValve vs Lotus (4.7% Lotus vs 8.6% CoreValve; HR, 0.53; 95% CI, 0.31-0.93; P = .02). More Lotus patients received a new permanent pacemaker (41.7% vs 26.1%; HR, 1.87; 95% CI, 1.41-2.49; P < .01) or had a valve thrombosis (3.0% vs 0.0%; P < .01) compared with CoreValve. More patients who received CoreValve experienced a repeated procedure (0.6% Lotus vs 2.9% CoreValve; HR, 0.19; 95% CI, 0.05-0.70; P < .01), valve migration (0.0% vs 0.7%; P = .05), or embolization (0.0% vs 2.0%; P < .01) than Lotus. Valve areas remained significantly larger and the mean gradient was lower with CoreValve than Lotus (valve area, mean [SD]: Lotus, 1.53 [0.49] cm2 vs CoreValve, 1.76 [0.51] cm2; P < .01; valve gradient, mean [SD]: Lotus, 13.0 [6.7] mm Hg vs 8.1 [3.7] mm Hg; P < .01). Moderate or greater PVL was more frequent with CoreValve (0.3% Lotus vs 3.8% CoreValve; P < .01) at 2 years. Larger improvements in New York Heart Association (NYHA) functional class were observed with Lotus compared with CoreValve (improved by ≥1 NYHA class: Lotus, 338 of 402 [84.1%] vs CoreValve, 143 of 189 [75.7%]; P = .01; improved by ≥2 NYHA classes: 122 of 402 [37.3%] vs 65 of 305 [21.3%]). Conclusions and Relevance: After 2 years, all-cause mortality rates, mortality or disabling stroke were similar between Lotus and CoreValve. Disabling stroke, functional class, valve migration, and PVL favored the Lotus arm whereas valve hemodynamics, thrombosis, and new pacemaker implantation favored the CoreValve arm. Trial Registration: clinicaltrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Australia/epidemiología , Boston/epidemiología , Ecocardiografía/métodos , Europa (Continente)/epidemiología , Femenino , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Humanos , Masculino , Readmisión del Paciente/estadística & datos numéricos , Diseño de Prótesis/tendencias , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Trombosis/etiología , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
14.
JACC Cardiovasc Interv ; 12(1): 38-49, 2019 01 14.
Artículo en Inglés | MEDLINE | ID: mdl-30621976

RESUMEN

OBJECTIVES: The authors sought to evaluate 1-year clinical outcomes with the Lotus valve (Boston Scientific, Marlborough, Massachusetts) in a large international, multicenter prospective registry including patients eligible for transcatheter aortic valve replacement (TAVR) based on heart team consensus. BACKGROUND: TAVR is a safe and effective treatment for severe aortic valve stenosis; however, limited data are available on TAVR with the repositionable and fully retrievable Lotus valve in unrestricted contemporary clinical practice. METHODS: The RESPOND (Repositionable Lotus Valve System-Post-Market Evaluation of Real World Clinical Outcomes) study enrolled 1,014 patients; 996 patients were implanted with the Lotus valve (mean age 80.8 years, 50.8% female, mean STS score 6.0 ± 6.9%). The primary endpoint was all-cause mortality in the intent-to-treat population at 30 days and 1 year. An Extension cohort of 50 patients was treated with the Lotus valve with Depth Guard including a modified delivery system. Mortality and stroke were independently adjudicated. An independent core laboratory assessed echocardiographic data. RESULTS: One-year clinical follow-up was available for 99.9% of Lotus valve-treated patients. At 1 year, the all-cause mortality rate was 11.7% and 4.1% of patients had experienced a disabling stroke. The permanent pacemaker implantation rate was 32% (37% among pacemaker-naive patients). Echocardiographic data at 1 year were available for core laboratory assessment in 62.6% of patients. Paravalvular leak was absent or trace in 94.5%, mild in 5.1%, and moderate in 0.4% of patients. Data from the Extension cohort confirmed good clinical outcomes at 30 days with an 18% permanent pacemaker rate (20% among pacemaker-naive patients). CONCLUSIONS: One-year outcomes from the RESPOND study confirm the safety and efficacy of the Lotus valve when used in routine clinical practice. (Repositionable Lotus Valve System-Post-Market Evaluation of Real World Clinical Outcomes [RESPOND]; NCT02031302).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Ecocardiografía , Europa (Continente) , Femenino , Humanos , América Latina , Masculino , Nueva Zelanda , Marcapaso Artificial , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 94(1): 82-90, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30666784

RESUMEN

OBJECTIVE: We evaluated 1-year outcomes after platinum chromium everolimus-eluting stents (PtCr-EES) in small versus non-small coronary arteries within a large, diverse sample of men, women, and minorities. BACKGROUND: There exists limited outcomes data on the use of second-generation drug-eluting stent to treat small diameter coronary arteries. METHODS: We pooled patients from the PLATINUM Diversity and PROMUS Element Plus stent registries. Small-vessel percutaneous coronary intervention (SV-PCI) was defined as ≥1 target lesion with reference vessel diameter (RVD) ≤2.5 mm. Endpoints included major adverse cardiac event (MACE; death, myocardial infarction [MI] or target vessel revascularization [TVR]), target vessel failure (TVF; death related to the target vessel, target vessel MI or TVR) and definite/probable stent thrombosis (ST). Multivariable Cox regression was used to risk-adjust outcomes. RESULTS: We included 4,155/4,182 (99%) patients with available RVD, of which 1,607 (39%) underwent small-vessel PCI. SV-PCI was not associated with increased MACE (adjHR 1.02; 95%CI 0.81-1.30) or TVF (adjHR 1.07; 95%CI 0.82-1.39). MI risk was lower in white men compared to women and minorities, both in the setting of SV-PCI (adjHR 0.41; 95%CI 0.23-0.74 and adjHR 0.39; 95%CI 0.20-0.75, respectively) and for non-SV-PCI (adjHR 0.61; 95%CI 0.38-0.99 and adjHR 0.45; 95%CI 0.27-0.74, respectively). There was no significant interaction between RVD and sex or minority status for any endpoint. CONCLUSION: In a large diverse contemporary PCI outcomes database, SV-PCI with PtCr-EES was not associated with increased MACE or TVR and did not account for the increased MI risk noted in women and minorities compared to white men.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Disparidades en el Estado de Salud , Salud de las Minorías , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etnología , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etnología , Trombosis Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etnología , Infarto del Miocardio/mortalidad , Estudios Observacionales como Asunto , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Factores Raciales , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
16.
Heart Lung Circ ; 28(3): 397-405, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29526416

RESUMEN

BACKGROUND: Late gadolinium enhancement (LGE) with cardiac magnetic resonance (CMR) is commonly assumed to represent myocardial fibrosis; however, comparative human histological data are limited, and there is no consensus on the most accurate method for LGE quantitation. We evaluated the relationship between CMR assessment of regional fibrosis and infarct size assessment using serial biomarkers after ST elevation acute myocardial infarction (STEMI). METHODS: Ninety-three patients treated for STEMI (59±10 years, 86% male) underwent CMR 6 months after infarction. Infarct size was quantified by CMR-LGE using manual and range of semi-automated thresholds (range: 2-10 standard deviations [SD]) above reference myocardium and the full width-half maximum (FWHM) technique, and compared with the rise in serum biomarkers. The agreement between CMR and biomarker in the identification of large infarcts based on peak troponin (TnI) levels was also analysed. RESULTS: Quantification methods had a strong influence on the infarct size assessment with CMR-LGE. Significant correlations were observed between LGE and biomarkers across all of the signal intensity thresholds. Whilst there was a wide variation with respect to the estimation of total LGE size (from 6.8±7.7 to 32.1±11.3 grams), the variation in the correlation with peak troponin level was much smaller (r-values ranging from 0.670 to 0.876). There was good agreement between CMR-LGE and biomarker assessment of infarct size; the best agreement between CMR-LGE and large infarction using a threshold of 8SD for peak TnI>50ng/mL (Cohen's kappa (κ)=0.722), and a threshold of 4SD for peak TnI >95ng/mL (κ=0.761). CONCLUSIONS: The correlation between CMR-LGE quantification of infarct size and biomarker release following STEMI at a range of semi-automated thresholds was consistently strong, with good agreement between measures across a range of thresholds.


Asunto(s)
Cicatriz/patología , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Infarto del Miocardio con Elevación del ST/diagnóstico , Troponina/sangre , Biomarcadores/sangre , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Infarto del Miocardio con Elevación del ST/sangre , Infarto del Miocardio con Elevación del ST/fisiopatología , Factores de Tiempo
17.
Catheter Cardiovasc Interv ; 93(3): 398-403, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30341836

RESUMEN

OBJECTIVES: The goal of this analysis was to evaluate the final 5-year safety and effectiveness of the PROMUS Element platinum-chromium everolimus-eluting stent in unselected patients treated in routine clinical practice. BACKGROUND: The prospective, open-label PROMUS Element™ European Post-Approval Surveillance Study (PE-PROVE) enrolled 1,010 "real-world" patients who received the PROMUS Element stent. Adverse event rates were low at 1-year, and the incidence of stent thrombosis was 0.6%. METHODS: The primary endpoint was target vessel failure (TVF; overall and PE stent-related), a composite of cardiac death, myocardial infarction (MI) related to the target vessel, or target vessel revascularization (TVR) at 1-year post-implantation. Five-year clinical outcomes were evaluated in overall as well as high-risk patient subgroups. RESULTS: The overall 5-year TVF rate was 14.9%, with 7.0% being related to the study stent. Cardiac death, MI and TVR related to the study stent occurred in 0.5%, 3.2%, and 5.7%, respectively. Stent thrombosis through 5-year follow-up was 1.0%. The rates of overall and study stent related TVF were numerically higher in patients with medically treated diabetes, long lesions (≥28 mm), and small diameter vessels (≤2.5 mm) compared to the overall study population. Additionally, favorable stent thrombosis rates through 5 years were reported for the PROMUS Element stent in these high-risk subgroups. CONCLUSIONS: The final 5-year data from the PE-PROVE study demonstrate favorable outcomes and low rates of adverse events with the PE stent when used in "real-world" patients with coronary artery disease.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Am Heart J ; 205: 110-117, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30218844

RESUMEN

BACKGROUND: While extended dual antiplatelet therapy (DAPT) with aspirin and a platelet (P2Y12) inhibitor after percutaneous coronary intervention (PCI) reduces the risk of stent thrombosis (ST) and myocardial infarction (MI), it also increases bleeding. Newer generation drug-eluting stents with bioabsorbable polymer coatings may reduce thrombotic events and allow abbreviated DAPT in selected patients. The EVOLVE Short DAPT study is designed to evaluate the safety of 3-month DAPT in high bleeding risk subjects treated with the SYNERGY bioabsorbable polymer everolimus-eluting stent. TRIAL DESIGN: EVOLVE Short DAPT is a prospective, single-arm, international study that enrolled 2009 high risk bleeding subjects (defined as age ≥75 years, chronic anticoagulation, major bleeding within 12 months, history of stroke, renal insufficiency/failure, or thrombocytopenia) who underwent PCI with the SYNERGY stent. Subjects presenting with acute MI or complex lesions were excluded. After 3 months treatment with DAPT (except those on anticoagulant in whom aspirin is optional), subjects free from stroke, MI, revascularization or ST will be eligible to discontinue P2Y12 inhibitor, but continue aspirin. Co-primary endpoints assessed between 3-15 months are: i) death/MI compared for non-inferiority with propensity-adjusted historical group receiving 12-month DAPT, and ii) definite/probable ST compared to a performance goal. The secondary endpoint is the rate of bleeding in subjects not receiving chronic anticoagulation compared for superiority against a propensity-adjusted historical control. CONCLUSION: The EVOLVE Short DAPT study will prospectively define the safety of DAPT discontinuation at 3 months in high bleeding risk patients treated with the SYNERGY stent.


Asunto(s)
Aspirina/administración & dosificación , Clopidogrel/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Hemorragia/epidemiología , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Anciano , Brasil/epidemiología , Enfermedad de la Arteria Coronaria/complicaciones , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada , Europa (Continente)/epidemiología , Femenino , Hemorragia/complicaciones , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
Int J Cardiol ; 270: 343-348, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-29907444

RESUMEN

BACKGROUND: Visual assessment of diameter-stenosis on Computed Tomography Coronary Angiography (CTCA) lacks specificity to determine functional significance of coronary artery stenosis. Percent-aggregate plaque volume (%APV) and ASLA score, which incorporates Area of Stenosis, Lesion length, and area of myocardium subtended estimated by APPROACH score (Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease) have been described to predict lesion specific ischaemia in focal lesions with intermediate stenosis. METHODS AND RESULTS: Included were 81 patients (mean age 64.7 ±â€¯9 years, 62% male; 94 vessels) who underwent 320- detector-row CTCA, invasive coronary angiography and fractional-flow-reserve (FFR). We examined vessels with wide range of diameter stenosis (mid to severe) and with multiple lesions. Invasive FFR of ≤0.8 was considered functionally significant. The first 54 patients (62 vessels) formed the derivation cohort. ASLA score was the best predictor of FFR ≤ 0.8 (AUC 0.83, p < 0.001) compared to %APV (0.72), CT >50% (0.76), APPROACH score (0.79), area-stenosis (0.73), diameter-stenosis (0.74), minimum-luminal-diameter (0.74), minimal-luminal-area (0.72), and lesion-length (0.67). ASLA score and not %APV, provided incremental predictive value when added to CT > 50 [(NRI 0.71, p = 0.005) vs. (NRI 0.01, p = 0.96)]. In the validation cohort of 27 patients (32 vessels), the ASLA score (AUC 0.85) was again a better predictor of FFR ≤ 0.8 compared to %APV (0.71), CT > 50% (0.66) and other CT indices. The AUC of ASLA score was superior to CTCA>50% (p = 0.001). CONCLUSION: ASLA score is a novel predictor of functional significance of coronary stenosis and adds incremental predictive value to CT > 50 but %APV did not.


Asunto(s)
Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/normas , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/fisiopatología , Anciano , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Femenino , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos