Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 119(31): e2202039119, 2022 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-35878029

RESUMEN

The emplacement of large igneous provinces (LIPs) has been linked to catastrophic mass extinctions in Earth's history, but some LIPs are only associated with less severe oceanic anoxic events, and others have negligible environmental effects. Although it is widely accepted that massive magma outpouring can affect the environment through volatile degassing, it remains debated what controls the severity of environmental crises. Here, we demonstrate that the second-most-voluminous Phanerozoic LIP, the Kerguelen LIP, may have contributed to the early Aptian oceanic anoxic event 1a, a global event previously believed to have been caused by the Ontong Java LIP. Geochronological data show that the earliest eruptions of the Kerguelen LIP preceded the onset of oceanic anoxic event 1a by at least ∼5 million years. Analyses of CO2 abundances in melt inclusions combined with Monte Carlo simulations reveal that the volume and degassing rate of CO2 emissions from the Kerguelen LIP are an order of magnitude lower compared to LIPs that caused severe mass extinctions. We propose that the severity of volcanism-related environmental and biotic perturbations is positively correlated with the volume and rate of CO2 emissions. Our results highlight the significant importance of reducing and slowing down CO2 emission in preventing future disastrous environmental consequences.

2.
Appl Radiat Isot ; 188: 110362, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35839713

RESUMEN

In this paper we describe experiments on two enriched 40K solutions to accurately determine decay data. The first solution was measured in 2004/2005 by means of a gamma-ray spectrometer with low background and a liquid scintillation (LS) counter to apply the CIEMAT/NIST efficiency tracing method. A combination of results yields an emission probability of the 1461 keV gamma-rays of Pγ = 0.1030(11) which is lower than current results of data evaluations. The activity concentration of the second solution was also determined by means of LS counting, but here, the CIEMAT/NIST efficiency tracing method as well as the TDCR method were applied. Again, the result was combined with that of independent gamma-ray spectrometry and the gamma-ray emission probability was found to be Pγ = 0.1029(9) in good agreement with the result obtained from the first solution. A combination of both experiments yields Pγ = 0.1029(9). The spectra of a TriCarb LS counter were carefully analyzed and a beta minus emission probability [Formula: see text]  = 0.8954(14) was determined. The new results for Pγ and [Formula: see text] indicate that the overall probability of the decay via EC in recent data evaluations is overestimated. The LS counting efficiencies were computed with a stochastic model and up-to-date calculations of the beta spectrum and fractional EC probabilities were used. The final activity result of the second solution is combined with the outcome of a comprehensive isotopic analysis to determine the half-life of 40K which is found to be 1.2536(27) ·109 years. All above-stated uncertainties are standard uncertainties (k = 1).


Asunto(s)
Radioisótopos , Espectrometría gamma , Semivida , Radioisótopos/análisis , Estándares de Referencia , Incertidumbre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA