Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Artif Organs ; 47(2): 380-386, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36148849

RESUMEN

BACKGROUND: Driveline (DL) damages are a common difficulty among ventricular assist devices (VAD). Repairing the electrical fibers inside the DL on a running pump is hazardous and requires technical expertise, which is not easily available on site. A new feature of the HeartMate3 (Abbott, U.S.A.) LVAD is a modular driveline that allows an easy exchange of the DL cord. In this report we analyze our experiences with this feature. METHODS: We performed a retrospective analysis of 302 patients who underwent either HeartMate II or HeartMate 3 implantation between February 2004 and September 2021. Patients were screened for driveline faults and need for exchange or repair of driveline or VAD exchange. Documented were baseline characteristics, reasons for DL or VAD exchange, and complications. Follow-up was three months after the procedure. RESULTS: We present a cohort of 302 patients who underwent either HMII (n = 107;35.4%) or HM 3 (n = 195; 64.5%) implantation. Out of those, 40 patients (40/302; 13.2%) required driveline repair (DLRe) or exchange (DLEx). Out of 107 HMII patients, 9 showed severe DL damages (9/107; 8.4%). Six patients (6/9; 66.6%) underwent DLRe, two patients (2/6; 33.3%) required VAD exchange after DLRe, one patient (1/2;50%) experienced emergency VAD exchange after pump stop. The DLRe procedure in the other four patients (4/6; 66.6%) was successful. Due to damage to the internal driveline two patients (2/9; 22.2%) underwent emergency device exchange and one patient (1/9;11.1%) was listed for transplantation. 31 out 195 HM3 patients underwent exchange of the modular DL. In none of the cases, damages of the internal fibers were the reasons for the exchange. In 100% of the cases, damages of the external coating were the reason for DL exchange. In none of the cases, complications occurred after the exchange procedure. CONCLUSIONS: Driveline damages are a habitual, recurrent complication in VAD patients. The exchange of the modular driveline cable of the HM3 is feasible and safe compared to the conventional DL repair in HMII patients. Risky repair attempts and surgical LVAD exchange due to major damages of the electrical fibers can be avoided successfully by the new feature of HM3 driveline.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Estudios Retrospectivos , Corazón Auxiliar/efectos adversos
3.
Artif Organs ; 46(11): 2293-2303, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35686944

RESUMEN

OBJECTIVES: Historically, females were described as suffering from worse outcomes after left ventricular assist device (LVAD) implantation. However, females' preoperative conditions are unique, making direct comparisons with males challenging. This study aimed to select through propensity score (PS) matching two preoperatively comparable populations of females and males and test if any real sex-related difference exists regarding survival and adverse events after LVAD implantation. METHODS: This retrospective single-center observational study investigated patients who received LVAD implantation between 2010 and 2018. PS matching was applied to balance preoperative heterogeneity between males and females. Primary endpoint was survival at follow-up. Secondary endpoints included perioperative outcomes and LVAD-related adverse events. RESULTS: 92 fully comparable females(n = 46) and males(n = 46) were selected after PS matching (median age:57 years, min-max:18-75). 26.1% of patients required preoperative mechanical circulatory support. Females needed more intraoperative fresh frozen plasma (p < 0.001) and platelets transfusions (p = 0.008) compared to males, but postoperative outcomes were comparable between groups. In-hospital, 1 and 2-year survival were 78.3%, 69.6% and 65.2%, respectively, with no differences between groups. Survival probability remained comparable up to 8 years of follow-up (p = 0.35). Overall, females showed a higher rate of strokes (p = 0.039) compared to males in the follow-up time. CONCLUSIONS: After reducing preoperative heterogeneity between females and males, survival after LVAD implantation does not differ based on sex. However, differences might exist in terms of higher transfusions and strokes in females. Reducing preoperative sex disparities and developing intraoperative and anticoagulation strategies which acknowledge sex-related variations might help abolishing differences in LVAD outcomes.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Masculino , Femenino , Humanos , Persona de Mediana Edad , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Insuficiencia Cardíaca/cirugía , Resultado del Tratamiento , Puntaje de Propensión
4.
Artif Organs ; 45(3): 230-235, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32920899

RESUMEN

Literature on the air travel activities of patients supported by permanent mechanical assist devices is rare. To the best of our knowledge, no air travel guidelines or fitness prerequisites exist on whether and when ventricular assist device (VAD) patients are allowed to travel by plane after device implantation. In this study, we evaluated the topic of air travel after VAD implantation. This working group aimed to produce a report on air travel passengers supported by VADs, regarding their fitness to fly. Fifty left ventricular assist device (LVAD) patients were surveyed in a worldwide multicenter study. The single survey was performed with a multimethod design, including interviews conducted face-to-face, online, and on phone. Out of 50 patients, 97% described their traveling by aircraft as perfect and uneventful during the flight. Eighty-five percent of the study participants consulted their medical practitioner before the flight. No patient reported the occurrence of a severe condition associated with flying. LVAD alarms, especially low flow alarms, did not occur in any of the devices. Thirty-five percent of the surveyed patients, however, stated a major problem pertaining to the security check procedures at the airport. The results of this study suggest that commercial air travel is safe for stable patients on permanent VAD support and traveling can be resumed securely after VAD implantation. Conscientious preparation by packing necessary devices, fluids, medications, and careful preparation for the airport security check is recommended.


Asunto(s)
Viaje en Avión/estadística & datos numéricos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/normas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Guías como Asunto , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Encuestas y Cuestionarios/estadística & datos numéricos , Resultado del Tratamiento , Adulto Joven
5.
Expert Rev Med Devices ; 17(4): 323-330, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32118488

RESUMEN

Introduction: The global heart failure (HF) burden is expected to increase due to aging populations, increasing number of end-stage HF patients and adverse lifestyle changes. Mechanical circulatory support (MCS) devices such as left ventricular assist devices (LVADs) have become a promising treatment option for short-term and long-term circulatory support of end-stage HF patients.Areas covered: Recent developments in MCS technology have been focused on miniaturization leading to the development of minimally invasive surgical procedures for LVAD implantation. This helps overcome possible postoperative complications such as major incisions and poor outcomes due to infections, right heart failure, and bleeding. This article discusses clinical and technological developments in the field of minimally invasive procedures for LVAD implantation.Expert opinion: Most patients might benefit from minimally invasive LVAD implantation performed through a limited left lateral thoracotomy associated with an upper hemisternotomy or a right anterior thoracotomy. The thoracotomy approach can also be considered in case of pump exchange or pump explant. The success of these techniques is mainly based on the optimization of LVAD pump design, inflow cannula insertion, and outflow graft as well as driveline exit sites. The future direction of the LVAD field is likely to include less-invasive approaches and smartificial technologies.


Asunto(s)
Corazón Auxiliar , Procedimientos Quirúrgicos Mínimamente Invasivos , Diseño de Prótesis , Implantación de Prótesis , Ensayos Clínicos como Asunto , Humanos , Miniaturización
6.
Expert Rev Med Devices ; 16(12): 1003-1015, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31774339

RESUMEN

Introduction: Heart failure (HF) is one of the rising problems in the contemporary society with growing incidences of end-stage HF. While heart transplantation (HT) is the gold standard treatment for end-stage HF, its availability is limited by the lack of heart donors. As a consequence, left ventricular assist devices (LVADs) are becoming key therapies as bridge to transplant (BTT) strategy to improve survival and outcomes.Areas covered: A significant advancement for wider applications of LVADs as BTT was facilitated by the introduction of miniaturized pumps such as the HVAD (HeartWare®, Medtronic, MN, USA), allowing intrapericardial implants and less-invasive approaches. In this review article, we describe the technical features of the HVAD and its outcomes in terms of efficacy and safety when implanted as BTT strategy. Moreover, we discuss the postoperative results of HT in HVAD recipients and its application in the pediatric population.Expert opinion: It has been demonstrated that the HVAD positively influences the survival of end-stage HF patients awaiting HT, with an acceptable rate of adverse events. Due to its reduced size, it is particularly suitable for LVAD implantations through lateral thoracotomy and in patients with small thoracic dimensions.


Asunto(s)
Insuficiencia Cardíaca/terapia , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Humanos , Diseño de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...