Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Imaging ; 10(9)2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39330443

RESUMEN

Non-contrast magnetic resonance angiography (NC-MRA), including fresh blood imaging (FBI), is a suitable choice for evaluating patients with peripheral artery disease (PAD). We evaluated standard FBI (sFBI) and centric ky-kz FBI (cFBI) acquisitions, using 1D and 2D parallel imaging factors (PIFs) to assess the trade-off between scan time and image quality due to blurring. The bilateral legs of four volunteers (mean age 33 years, two females) were imaged in the coronal plane using a body array coil with a posterior spine coil. Two types of sFBI and cFBI sequences with 1D PIF factor 5 in the phase encode (PE) direction (in-plane) and 2D PIF 3 (PE) × 2 (slice encode (SE)) (in-plane, through-slice) were studied. Image quality was evaluated by a radiologist, the vessel's signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured, and major vessel width was measured on the coronal maximum intensity projection (MIP) and 80-degree MIP. Results showed significant time reductions from 184 to 206 s on average when using sFBI down to 98 to 162 s when using cFBI (p = 0.003). Similar SNRs (averaging 200 to 370 across all sequences and PIF) and CNRs (averaging 190 to 360) for all techniques (p > 0.08) were found. There was no significant difference in the image quality (averaging 4.0 to 4.5; p > 0.2) or vessel width (averaging 4.1 to 4.9 mm; p > 0.1) on coronal MIP due to sequence or PIF. However, vessel width measured using 80-degree MIP demonstrated a significantly wider vessel in cFBI (5.6 to 6.8 mm) compared to sFBI (4.5 to 4.7 mm) (p = 0.022), and in 1D (4.7 to 6.8 mm) compared to 2D (4.5 to 5.6 mm) (p < 0.05) PIF. This demonstrated a trade-off in T2 blurring between 1D and 2D PIF: 1D using a PIF of 5 shortened the acquisition window, resulting in sharper arterial blood vessels in coronal images but significant blur in the 80-degree MIP. Two-dimensional PIF for cFBI provided a good balance between shorter scan time (relative to sFBI) and good sharpness in both in- and through-plane, while no benefit of 2D PIF was seen for sFBI. In conclusion, this study demonstrated the usefulness of FBI-based techniques for peripheral artery imaging and underscored the need to strike a balance between scan time and image quality in different planes through the use of 2D parallel imaging.

2.
J Clin Med ; 13(16)2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39200736

RESUMEN

Background: Computed tomography (CT) is the preferred imaging modality for bone evaluation of the knee, while MRI of the bone is actively being developed. We present three techniques using short-interval delta ultrashort echo time (δUTE), field echo (FE), and FE with high resolution-deep learning reconstruction (HR-DLR) for direct bone MRI. Methods: Knees of healthy volunteers (n = 5, 3 females, 38 ± 17.2 years old) were imaged. CT-like images were generated by averaging images from multiple echoes and inverting. The bone signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined. Results: The δUTE depicted a cortical bone with high signal intensity but could not resolve trabeculae. In contrast, both the FE and FE HR-DLR images depicted cortical and trabecular bone with high signal. Quantitatively, while δUTE had a good bone SNR of ~100 and CNR of ~40 for the cortical bone, the SNR for the FE HR-DLR was significantly higher (p < 0.05), at over 400, and CNR at over 200. Conclusions: For 3D rendering of the bone surfaces, the δUTE provided better image contrast and separation of bone from ligaments and tendons than the FE sequences. While there still is no MRI technique that provides a perfect CT-like contrast, continued advancement of MRI techniques may provide benefits for specific use cases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA