Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ann Geriatr Med Res ; 28(2): 201-208, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38509825

RESUMEN

BACKGROUND: Older patients are particularly vulnerable to age-related respiratory changes. This prospective randomized controlled trial studied the effects of high and low fractions of inspired oxygen (FiO2) with the recruitment maneuver (RM) during extubation on lung atelectasis postoperatively in older patients undergoing major abdominal surgery. METHODS: We randomized a total of 126 patients aged >60 years who underwent both elective and emergency major abdominal surgeries and met the inclusion criteria into three groups (H, HR, and LR) using computer-generated block randomization. Group H received high FiO2 (1), Group HR received high FiO2 (1) with RM followed by a positive end-expiratory pressure of 5 cm H2O, and Group LR received low FiO2 (0.4) with RM followed by a positive end-expiratory pressure of 5 cm H2O 10 minutes before extubation. Oxygenation and atelectasis were measured using the arterial partial pressure of oxygen (PaO2)/FiO2 ratios and lung ultrasound score. Postoperative pulmonary complications were recorded up to 24 hours postoperatively. RESULTS: The mean PaO2/FiO2 at 30 minutes post-extubation was significantly higher in Groups LR and HR compared to that in Group H (390.71±29.55, 381.97±24.97, and 355.37±31.70; p<0.001). In the immediate postoperative period, the median lung ultrasound score was higher in Group H than that in Groups LR and HR (6 [5-7], 3 [3-5], and 3.5 [2.25-4.75]; p<0.001). The incidence of oxygen desaturation and oxygen requirements was higher in Group H during the postoperative period. CONCLUSION: The RM before extubation is beneficial in reducing atelectasis and postoperative pulmonary complications, irrespective of the FiO2 concentration used in older adults undergoing major abdominal surgeries. (Trail registration number: Reference No. CTRI/2022/04/042115; date of CTRI registration 25/02/2022; and date of enrolment of the first research participant 05/05/2022).

6.
Indian J Anaesth ; 65(4): 321-327, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34103747

RESUMEN

BACKGROUND AND AIMS: Glidescope®videolaryngoscope (GVL) is a video intubation system with 60° angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope®videolaryngoscope (GVL) in hypertensive patients. METHODS: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. RESULTS: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. CONCLUSION: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...