Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Braz Dent J ; 27(4): 424-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27652705

RESUMEN

Root canal irrigants are used to minimize the negative effects of smear layer on endodontic sealer retention. The aim of this study was to evaluate the efficacy of agitation of 17% ethylenediaminetetraacetic acid (EDTA) with ultrasonic, 1064-nm Nd:YAG and 980-nm diode laser on the retention of an epoxy-based sealer to the root canal walls. Forty single-rooted bovine teeth were instrumented with ProTaper rotary system and divided into four groups according to the final irrigation protocol (n = 10): (1) 17% EDTA (control); (2) 17% EDTA with 50-s ultrasonic agitation; (3) 17% EDTA with 50-s diode laser (2-W) agitation; and (4) 17% EDTA with 50-s Nd:YAG (1.5-W) laser agitation. After endodontic filling with gutta-percha F5 master cone and Sealer 26, the roots were sectioned at the cervical, middle, and apical root thirds to obtain 1.5-mm slices. Push-out tests were performed using a universal testing machine at a 1 mm/min crosshead speed. Data were analyzed using two-way ANOVA and Tukey's tests (α=0.05). Apical root thirds had significant higher retention values than cervical and middle thirds (p < 0.05). EDTA with 1064-nm Nd:YAG or 980-nm diode laser presented the highest retention values and was significantly different from EDTA with ultrasonic agitation and EDTA only (p < 0.05). Adhesive failures were predominant to EDTA only group. Mixed failures were predominant to all agitation groups. 1064-nm Nd:YAG and 980-nm diode laser EDTA agitation enhanced the retention of the epoxy-based sealer to the root canal walls compared with that due to EDTA only or EDTA with ultrasonic agitation.


Asunto(s)
Dentina/química , Ácido Edético/química , Resinas Epoxi/química , Rayos Láser , Materiales de Obturación del Conducto Radicular/química , Humanos
2.
Braz. dent. j ; 27(4): 424-429, July-Aug. 2016. tab
Artículo en Inglés | LILACS | ID: lil-794623

RESUMEN

Abstract Root canal irrigants are used to minimize the negative effects of smear layer on endodontic sealer retention. The aim of this study was to evaluate the efficacy of agitation of 17% ethylenediaminetetraacetic acid (EDTA) with ultrasonic, 1064-nm Nd:YAG and 980-nm diode laser on the retention of an epoxy-based sealer to the root canal walls. Forty single-rooted bovine teeth were instrumented with ProTaper rotary system and divided into four groups according to the final irrigation protocol (n = 10): (1) 17% EDTA (control); (2) 17% EDTA with 50-s ultrasonic agitation; (3) 17% EDTA with 50-s diode laser (2-W) agitation; and (4) 17% EDTA with 50-s Nd:YAG (1.5-W) laser agitation. After endodontic filling with gutta-percha F5 master cone and Sealer 26, the roots were sectioned at the cervical, middle, and apical root thirds to obtain 1.5-mm slices. Push-out tests were performed using a universal testing machine at a 1 mm/min crosshead speed. Data were analyzed using two-way ANOVA and Tukey's tests (α=0.05). Apical root thirds had significant higher retention values than cervical and middle thirds (p < 0.05). EDTA with 1064-nm Nd:YAG or 980-nm diode laser presented the highest retention values and was significantly different from EDTA with ultrasonic agitation and EDTA only (p < 0.05). Adhesive failures were predominant to EDTA only group. Mixed failures were predominant to all agitation groups. 1064-nm Nd:YAG and 980-nm diode laser EDTA agitation enhanced the retention of the epoxy-based sealer to the root canal walls compared with that due to EDTA only or EDTA with ultrasonic agitation.


Resumo Irrigantes para canais radiculares são usados para minimizar os efeitos negativos da camada de smear na retenção do cimento obturador. O objetivo deste estudo foi avaliar a eficácia da agitação do ácido etilenodiaminotetracético a 17% (EDTA) com ultrassom, Nd:YAG 1064-nm e laser diodo 980-nm na retenção de um cimento obturador à base de resina epóxica nas paredes do canal radicular. Quarenta dentes bovinos unirradiculares foram instrumentados com o sistema rotatório ProTaper e divididos em quatro grupos de acordo com o protocolo de irrigação final (n = 10): (1) EDTA 17% (controle); (2) EDTA 17% com agitação ultrassônica por 50-s; (3) EDTA 17% com agitação com laser diodo (2-W) por 50-s; e (4) EDTA 17% com agitação com laser Nd:YAG (1,5-W) por 50-s. Após obturação endodôntica com cone principal F5 e cimento Sealer 26, as raízes foram seccionadas nos terços radiculares cervical, médio e apical para obtenção de slices de 1,5-mm. Testes de push-out foram realizados utilizando uma máquina universal de ensaios com velocidade de carga de 1 mm/min. Os dados foram analisados utilizando os testes two-way ANOVA e Tukey's (α=0,05). Os terços radiculares apicais tiveram força de adesão significantemente maior que os terços cervical e médio (p<0,05). EDTA com Nd:YAG 1064-nm ou laser diodo 980-nm apresentaram os maiores valores de força de adesão e foram significantemente diferentes do EDTA com agitação ultrassônica e EDTA apenas (p < 0,05). Falhas adesivas foram predominantes apenas no grupo EDTA. Falhas mistas foram predominantes em todos os grupos de agitação. A agitação do EDTA com Nd:YAG 1064-nm e laser diodo 980-nm aumentou a força de adesão do cimento à base de resina epóxica às paredes do canal radicular comparado com a obtida com EDTA apenas ou EDTA com agitação ultrassônica.


Asunto(s)
Humanos , Dentina/química , Ácido Edético/química , Resinas Epoxi/química , Rayos Láser , Materiales de Obturación del Conducto Radicular/química
3.
Braz. dent. j ; 27(3): 303-308, May-June 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-782815

RESUMEN

Abstract This study evaluated the effect of restorative protocol with sodium ascorbate on the shear bond strength (SBS) of a universal adhesive to intracoronal bleached dentin. One hundred-and-twenty bovine dentin fragments were randomly divided into 12 groups (n=10), according to the bleaching procedure (unbleached and bleached) and restorative protocol (no treatment, 10% sodium ascorbate -10SA, 35% sodium ascorbate -35SA and two-step etch-and-rinse -ER or one-step self-etch -SE Scotchbond universal adhesive approaches). Four whitening sessions were performed using 35% hydrogen peroxide. The samples from control groups were kept in relative humidity at 37 °C. Immediately after bleaching procedures, the assigned antioxidant solution was applied on dentin and restorative procedures were performed following either the ER or the SE approach. After 24 h, the specimens were subjected to SBS test. Data (MPa) were analyzed by ANOVA and Tukey's test (?=0.05). Lower SBS values were found for bleached specimens (8.54 MPa) compared with those unbleached (12.13 MPa) (p<0.05). The bond strength of the sodium ascorbate-treated groups was higher than those untreated, regardless of the strategy employed (p<0.05). Groups restored without sodium ascorbate showed lower bond strength values for both ER (8.32 MPa) and SE (8.28 MPa) adhesive strategies. The group treated with 10SA submitted to ER approach (10.14 MPa) was similar to untreated groups (p>0.05). It may be concluded that bond strength of composite resin to intracoronal dentin was affected by restorative protocol and reduced by bleaching.


Resumo Este estudo avaliou o efeito do protocolo restaurador empregando ascorbato de sódio na resistência ao cisalhamento do adesivo universal à dentina intracoronária clareada. Cento e vinte fragmentos de dentina bovina foram aleatoriamente divididos em doze grupos (n=10), de acordo com o procedimento clareador (clareados e não clareados) e protocolo restaurador (sem tratamento, ascorbato de sódio 10% (10AS), ascorbato de sódio (35AS) e estratégia de condicionamento total de dois passos (ER) ou estratégia autocondicionante de um passo (SE) com o sistema adesivo Scotchbond universal. Quatro sessões de clareamento foram realizadas empregando peróxido de hidrogênio a 35%. Os espécimes do grupo controle foram mantidos em umidade relativa a 37 °C. Imediatamente após os procedimentos de clareamento, as soluções antioxidantes selecionadas foram empregadas na dentina e os procedimentos restauradores foram realizados seguindo as estratégias ER ou SE. Após 24 h, os espécimes foram submetidos ao teste de resistência ao cisalhamento. Os dados (MPa) foram analisados pela ANOVA e teste de Tukey (?=0,05). Os menores valores de resistência ao cisalhamento foram encontrados para os espécimes clareados (8,54 MPa) comparados com aqueles não clareados (12,13 MPa) (p<0,05). A resistência de união dos grupos tratados com ascorbato de sódio foi maior que aqueles não tratados (p<0,05), independentemente da estratégia empregada. Grupos restaurados sem ascorbato de sódio demonstraram menores valores de resistência de união para ambas as estratégias adesivas ER (8,32 MPa) e SE (8,28 MPa) (p<0,05). O grupo tratado com ascorbato de sódio a 10% submetido à estratégia ER (10,14 MPa) foi similar ao não tratado (p>0,05). Pode ser concluído que a resistência de união da resina composta à dentina intracoronária foi afetada pelo protocolo restaurador e reduzida pelo clareamento.


Asunto(s)
Animales , Bovinos , Adhesivos , Ácido Ascórbico/química , Recubrimiento Dental Adhesivo , Dentina/química , Ensayo de Materiales
4.
Braz Dent J ; 27(3): 303-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27224564

RESUMEN

This study evaluated the effect of restorative protocol with sodium ascorbate on the shear bond strength (SBS) of a universal adhesive to intracoronal bleached dentin. One hundred-and-twenty bovine dentin fragments were randomly divided into 12 groups (n=10), according to the bleaching procedure (unbleached and bleached) and restorative protocol (no treatment, 10% sodium ascorbate -10SA, 35% sodium ascorbate -35SA and two-step etch-and-rinse -ER or one-step self-etch -SE Scotchbond universal adhesive approaches). Four whitening sessions were performed using 35% hydrogen peroxide. The samples from control groups were kept in relative humidity at 37 °C. Immediately after bleaching procedures, the assigned antioxidant solution was applied on dentin and restorative procedures were performed following either the ER or the SE approach. After 24 h, the specimens were subjected to SBS test. Data (MPa) were analyzed by ANOVA and Tukey's test (?=0.05). Lower SBS values were found for bleached specimens (8.54 MPa) compared with those unbleached (12.13 MPa) (p<0.05). The bond strength of the sodium ascorbate-treated groups was higher than those untreated, regardless of the strategy employed (p<0.05). Groups restored without sodium ascorbate showed lower bond strength values for both ER (8.32 MPa) and SE (8.28 MPa) adhesive strategies. The group treated with 10SA submitted to ER approach (10.14 MPa) was similar to untreated groups (p>0.05). It may be concluded that bond strength of composite resin to intracoronal dentin was affected by restorative protocol and reduced by bleaching.


Asunto(s)
Adhesivos , Ácido Ascórbico/química , Recubrimiento Dental Adhesivo , Dentina/química , Animales , Bovinos , Ensayo de Materiales
5.
Photomed Laser Surg ; 33(7): 349-56, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26154722

RESUMEN

OBJECTIVE: The purpose of this study was to analyze the effects of agitation of 17% ethylenediaminetetraacetic acid (EDTA) with 1064 nm Nd:YAG and 980 nm diode laser on root dentin microhardness and superficial roughness (with confocal laser scanning microscopy [CLSM]). BACKGROUND DATA: Root canal irrigants are used in an attempt to minimize the negative effects of smear layer. MATERIALS AND METHODS: Twenty-five bovine roots were sectioned longitudinally and divided into five groups (n=10 each): (1) deionized water, (2) 17% EDTA, (3) 17% EDTA with 60 sec manual agitation, (4) 17% EDTA with 50 sec diode laser (2 W) agitation, and (5) 17% EDTA with 50 sec Nd:YAG (1.5 W) laser agitation. Microhardness and superficial roughness values were calculated before and after the procedures at the cervical, middle, and apical root thirds. Microhardness was statistically analyzed using two way ANOVA, paired t test, and Tukey's tests (α=0.05). Roughness was statistically analyzed using Kruskal-Wallis, paired t test, and Student-Newman-Keuls tests (α=0.05%). RESULTS: Statistically significant differences in microhardness and roughness were observed between the deionized water group and others. EDTA with 1064 nm Nd:YAG or 980 nm diode laser presented the lowest microhardness and the highest roughness values and was significantly different from EDTA with manual agitation and EDTA only (p<0.05). However, there were no differences in microhardness or dentin roughness between the root thirds (p>0.05). CLSM analysis showed that the control samples exhibited smoother surfaces than that of the EDTA groups. CONCLUSIONS: Nd:YAG 1064 nm and 980-nm diode laser EDTA agitation caused greater reduction in microhardness and increased roughness of root dentin than EDTA only or EDTA with manual agitation.


Asunto(s)
Ácido Edético , Láseres de Semiconductores , Láseres de Estado Sólido , Terapia por Luz de Baja Intensidad , Raíz del Diente/efectos de la radiación , Raíz del Diente/ultraestructura , Animales , Bovinos , Dureza/efectos de la radiación , Microscopía Electrónica de Rastreo , Irrigantes del Conducto Radicular , Técnicas de Cultivo de Tejidos
6.
Braz Dent J ; 25(5): 430-4, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25517780

RESUMEN

This study aimed to evaluate, by scanning electron microscopy (SEM), the cleaning of canal walls with moderate curvature subjected to biomechanical preparation with different final diameters using apical negative pressure irrigation. Thirty-two mesiobuccal roots of molars were divided into 4 groups (n=8) according to the instrument's final diameter: GI: 30.02, GII: 35.02, GIII: 40.02 and GIV: 45.02. Irrigating procedure was performed at each change of instrument with 1% NaOCl using the Endovac system. Final irrigation was conducted with 17% EDTA for 5 min. The SEM photomicrographs were evaluated under 35× and 1000× magnification, by three calibrated examiners, in a double-blind design. Data were submitted to Kruskal-Wallis and Dunn's post hoc tests (α=0.05). Canals instrumented with 30.02 and 35.02 final diameters showed more debris, statistically different from the other groups (p<0.05). Comparing each root canal third, for the cervical and apical portions no statistically significant difference (p>0.05) was found among the four groups. Regarding the presence of smear layer, canals with 30.02 final diameter showed the highest scores, statistically different from the 45.02 group (p<0.05) and similar to the 35.02 and the 40.02 groups (p>0.05). Although none of the studied diameters completely removed debris and smear layer, it may be concluded that instrumentation with higher final diameters was more effective in cleaning the root canals with moderate curvature.


Asunto(s)
Cavidad Pulpar/ultraestructura , Preparación del Conducto Radicular/métodos , Capa de Barro Dentinario/ultraestructura , Irrigación Terapéutica/métodos , Ápice del Diente/ultraestructura , Método Doble Ciego , Ácido Edético/administración & dosificación , Humanos , Microscopía Electrónica de Rastreo , Presión , Irrigantes del Conducto Radicular/administración & dosificación , Preparación del Conducto Radicular/instrumentación , Hipoclorito de Sodio/administración & dosificación , Irrigación Terapéutica/instrumentación , Cuello del Diente/ultraestructura , Vacio
7.
Braz. dent. j ; 25(5): 430-434, Sep-Oct/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-731045

RESUMEN

This study aimed to evaluate, by scanning electron microscopy (SEM), the cleaning of canal walls with moderate curvature subjected to biomechanical preparation with different final diameters using apical negative pressure irrigation. Thirty-two mesiobuccal roots of molars were divided into 4 groups (n=8) according to the instrument's final diameter: GI: 30.02, GII: 35.02, GIII: 40.02 and GIV: 45.02. Irrigating procedure was performed at each change of instrument with 1% NaOCl using the Endovac system. Final irrigation was conducted with 17% EDTA for 5 min. The SEM photomicrographs were evaluated under 35× and 1000× magnification, by three calibrated examiners, in a double-blind design. Data were submitted to Kruskal-Wallis and Dunn's post hoc tests (α=0.05). Canals instrumented with 30.02 and 35.02 final diameters showed more debris, statistically different from the other groups (p<0.05). Comparing each root canal third, for the cervical and apical portions no statistically significant difference (p>0.05) was found among the four groups. Regarding the presence of smear layer, canals with 30.02 final diameter showed the highest scores, statistically different from the 45.02 group (p<0.05) and similar to the 35.02 and the 40.02 groups (p>0.05). Although none of the studied diameters completely removed debris and smear layer, it may be concluded that instrumentation with higher final diameters was more effective in cleaning the root canals with moderate curvature.


Este estudo buscou avaliar, por meio de microscopia eletrônica de varredura (MEV), a limpeza das paredes de canais com curvatura moderada, submetidos ao preparo biomecânico com diferentes diâmetros finais utilizando-se irrigação por pressão apical negativa. Trinta e duas raízes mésio-vestibulares de molares foram divididas em 4 grupos (n=8) de acordo com o diâmetro final dos instrumentos: GI: 30.02, GII: 35.02, GIII: 40.02 e GIV: 45.02. O procedimento de irrigação foi realizado a cada troca de instrumento com NAOCl 1% utilizando o sistema EndoVac. A irrigação final foi conduzida com EDTA 17% por 5 min. As microfotografias de MEV foram avaliadas sob aumentos de 35× e 1000×, por três examinadores calibrados, em estudo duplo-cego. Os dados foram submetidos ao teste de Kruskal-Wallis e pós-teste de Dunn (=0,05). Os canais instrumentados com diâmetros finais de 30.02 e 35.02 demonstraram mais debris, estatisticamente diferente dos demais grupos (p<0,05). Comparando-se cada terço do canal radicular, para as porções cervical e apical não foi encontrada diferença estatisticamente significante (p>0,05) entre os quatro grupos. Com relação à presença de smear layer, canais com diâmetro final de 30.02 demonstraram os maiores scores, estatisticamente diferente do grupo 45.02 (p<0,05) e similar aos grupos 35.02 e 40.02 (p>0,05). Apesar de nenhum dos diâmetros estudados ter removido completamente os debris e a smear layer, pode ser concluído que a instrumentação com diâmetros finais maiores foi mais efetiva na limpeza dos canais radiculares com curvatura moderada.


Asunto(s)
Humanos , Antimetabolitos Antineoplásicos/uso terapéutico , Quimioterapia Adyuvante , Neoplasias Colorrectales/enzimología , Desoxicitidina/análogos & derivados , Floxuridina/uso terapéutico , Oxidorreductasas/biosíntesis , Timidina Fosforilasa/biosíntesis , Capecitabina , Neoplasias Colorrectales/mortalidad , Dihidrouracilo Deshidrogenasa (NADP) , Supervivencia sin Enfermedad , Desoxicitidina/uso terapéutico , Ensayo de Inmunoadsorción Enzimática , Fluorouracilo/análogos & derivados , Recurrencia , Factores de Tiempo
8.
Photomed Laser Surg ; 32(9): 495-9, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25102338

RESUMEN

OBJECTIVE: The purpose of this study was to assess the bond strength of a restorative material to bleached dentin, pretreated with Er:YAG laser. BACKGROUND DATA: Laser irradiation for dental surface treatment may increase the bond strength of restorative material to tooth surface. There are no reports of using Er:YAG laser on dentin bleached with 35% hydrogen peroxide. METHODS: Forty maxillary canines were sectioned, resulting in 80 fragments (5×5 mm) of intracoronary dentin that were divided into eight groups (n=10) according to the dental bleaching (present or not), surface conditioning (with or without laser) and the post-bleaching time to perform restoration (immediately or 7 days). The bleached specimens received two applications of 38% hydrogen peroxide. Er:YAG laser was applied for 20 sec with 400 mJ/15 Hz. Restorative procedure was performed using phosphoric acid, an adhesive system, and resin using a split Teflon matrix. The specimens were submitted to shear bond strength test and the data (MPa) were analyzed by ANOVA and Tukey's test (α=0.05). RESULTS: There were significant differences among the three factors (p<0.05). The highest values were obtained for unbleached specimens compared with bleached, for those treated with laser compared with those only conditioned with acid, and for those restored after 7 days compared with those having immediate restoration. In the interaction of factors, the bleached specimens treated with laser and restored immediately were statistically similar (p>0.05) to those bleached and restored after 7 days. CONCLUSIONS: Er:YAG laser can restore the bond strength of the dentin/restorative material interface even if the restoration is performed immediately after bleaching.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Dentina/efectos de la radiación , Láseres de Estado Sólido , Diente Canino , Cementos Dentales/química , Análisis del Estrés Dental , Combinación de Medicamentos , Humanos , Peróxido de Hidrógeno/química , Técnicas In Vitro , Curación por Luz de Adhesivos Dentales , Peróxidos/química , Polivinilos/química , Propiedades de Superficie , Blanqueamiento de Dientes , Urea/análogos & derivados , Urea/química
9.
Am J Dent ; 25(2): 114-7, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22779286

RESUMEN

PURPOSE: To evaluate the effect of a 1.23% acidulated phosphate fluoride (APF) gel combined with CO2 laser in protecting carious root dentin against further cariogenic challenges. METHODS: After a 7-day lead-in period, 12 volunteers wore an intraoral palatal device containing four carious root dentin slabs, treated with APF and APF+CO2 or placebo and placebo+CO2. After a 14-day wash-out period, volunteers were crossed-over to the other treatment arm. During both intraoral phases, specimens were submitted to cariogenic challenges and then evaluated for cross-sectional Knoop microhardness. RESULTS: Two-way ANOVA demonstrated that there was significant effect for both main factors: CO2 laser irradiation (P < 0.0001) and gel treatment (P < 0.0001), and that there was no interaction between them (P = 0.4706). Protection of carious root dentin against further cariogenic challenges may be provided by APF fluoride gel and CO2 laser, but no additive benefit was found by combining such strategies.


Asunto(s)
Fluoruro de Fosfato Acidulado/uso terapéutico , Dentina/efectos de los fármacos , Láseres de Gas/uso terapéutico , Terapia por Luz de Baja Intensidad/métodos , Caries Radicular/prevención & control , Adulto , Anatomía Transversal , Cariogénicos/efectos adversos , Estudios Cruzados , Susceptibilidad a Caries Dentarias/efectos de los fármacos , Susceptibilidad a Caries Dentarias/efectos de la radiación , Dentina/efectos de la radiación , Progresión de la Enfermedad , Método Doble Ciego , Geles , Dureza , Humanos , Placebos , Sacarosa/efectos adversos , Adulto Joven
10.
Braz Dent J ; 23(6): 679-85, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23338260

RESUMEN

The aim of this study was to assess the influence of surface pretreatments of fiber-reinforced posts on flexural strength (FS), modulus of elasticity (ME) and morphology of these posts, as well as the bond strength (BS) between posts and core material. Fifty-two fiber posts (smooth and serrated) were assigned to 4 groups (n=13): no treatment (control), 10% hydrogen peroxide (HP) for 10 min (HP-10), 24% HP for 1 min (HP-24) and airborne-particle abrasion (Al(2)O(3)). To evaluate FS and ME, a 3-point bending test was performed. Three posts of each group were examined by scanning electron microscopy. Composite resin was used as the core build-up and samples were sectioned to obtain microtensile sticks. Data were analyzed by ANOVA and Tukey's test (α=0.05). For FS, significant differences were observed between posts type and surface pretreatment (p<0.05), with the highest means for the smooth posts. Al2O3 provided higher FS than HP-24. Al(2)O(3) promoted higher ME than HP-24 and control. SEM images revealed partial dissolution of the resin matrix in all treated groups. The smooth posts had higher BS and FS than serrated posts (p<0.05). Mechanical properties of the glass fiber posts and the bond strength between posts and composite material were not altered by the surface treatments, except for airborne-particle abrasion that increased the post elastic modulus.


Asunto(s)
Recubrimiento Dental Adhesivo , Grabado Dental/métodos , Materiales Dentales/química , Vidrio/química , Técnica de Perno Muñón/instrumentación , Óxido de Aluminio/química , Resinas Compuestas/química , Diseño de Prótesis Dental , Análisis del Estrés Dental/instrumentación , Módulo de Elasticidad , Resinas Epoxi/química , Humanos , Peróxido de Hidrógeno/química , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Oxidantes/química , Docilidad , Silanos/química , Solubilidad , Estrés Mecánico , Propiedades de Superficie , Temperatura , Resistencia a la Tracción , Factores de Tiempo , Agua/química
11.
Braz. dent. j ; 23(6): 679-685, 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-662426

RESUMEN

The aim of this study was to assess the influence of surface pretreatments of fiber-reinforced posts on flexural strength (FS), modulus of elasticity (ME) and morphology of these posts, as well as the bond strength (BS) between posts and core material. Fifty-two fiber posts (smooth and serrated) were assigned to 4 groups (n=13): no treatment (control), 10% hydrogen peroxide (HP) for 10 min (HP-10), 24% HP for 1 min (HP-24) and airborne-particle abrasion (Al2O3). To evaluate FS and ME, a 3-point bending test was performed. Three posts of each group were examined by scanning electron microscopy. Composite resin was used as the core build-up and samples were sectioned to obtain microtensile sticks. Data were analyzed by ANOVA and Tukey's test (α=0.05). For FS, significant differences were observed between posts type and surface pretreatment (p<0.05), with the highest means for the smooth posts. Al2O3 provided higher FS than HP-24. Al2O3 promoted higher ME than HP-24 and control. SEM images revealed partial dissolution of the resin matrix in all treated groups. The smooth posts had higher BS and FS than serrated posts (p<0.05). Mechanical properties of the glass fiber posts and the bond strength between posts and composite material were not altered by the surface treatments, except for airborne-particle abrasion that increased the post elastic modulus.


O objetivo deste estudo foi avaliar a influência do pré-tratamento de superfície dos pinos de fibra de vidro na resistência à flexão (RF), módulo de elasticidade (ME) e morfologia, bem como a resistência de união (RU) entre os pinos e o núcleo de preenchimento. Cinqüenta e dois pinos de fibra de vidro (lisos e serrilhados) foram divididos em 4 grupos (n=13): sem tratamento (controle), peróxido de hidrogênio a 10% por 10 min (HP-10), peróxido de hidrogênio 24% por 1 min (HP-24) e jato de óxido de alumínio (Al2O3). Para avaliar a RF e ME, o ensaio de flexão de 3 pontos foi realizado. Três pinos de cada grupo foram examinados em MEV. Resina composta foi utilizada como núcleo de preenchimento e as amostras foram seccionadas para obter palitos de microtração. Os dados foram analisados por ANOVA e teste de Tukey (α=0,05). Na RF, observou-se diferença estatisticamente significante entre os pinos e tipo de pré-tratamento de superfície (p<0,05), com as maiores médias para os pinos lisos. Al2O3 proporcionou maior RF que HP-24. Al2O3 promoveu maior ME que HP-24 e grupo controle. MEV revelou dissolução parcial da matriz de resina em todos os grupos tratados. Os pinos lisos tiveram a maior RU (p<0,05). Os pinos lisos apresentaram RF e RU superior aos pinos serrilhados (p<0,05). As propriedades mecânicas dos pinos de fibra de vidro e a resistência de união entre os pinos e o material resinoso não foram alterados pelos tratamentos de superfície, com exceção do jato de óxido de alumínio que aumentou o módulo de elasticidade dos pinos.


Asunto(s)
Humanos , Recubrimiento Dental Adhesivo , Grabado Dental/métodos , Materiales Dentales/química , Vidrio/química , Técnica de Perno Muñón/instrumentación , Óxido de Aluminio/química , Resinas Compuestas/química , Diseño de Prótesis Dental , Análisis del Estrés Dental/instrumentación , Módulo de Elasticidad , Resinas Epoxi/química , Peróxido de Hidrógeno/química , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Oxidantes/química , Docilidad , Solubilidad , Estrés Mecánico , Propiedades de Superficie , Silanos/química , Temperatura , Resistencia a la Tracción , Factores de Tiempo , Agua/química
12.
Braz Dent J ; 22(5): 382-7, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22011893

RESUMEN

This study evaluated the effect of 980-nm diode laser on apical microleakage and intraradicular dentin morphology. Roots of 110 mandibular incisors were used in the study: 92 for microleakage test and 18 for scanning electron microscopy (SEM). Roots were randomly assigned to 3 groups according to the irrigating solution (water, NaOCl and NaOCl/EDTA) and were divided into 3 subgroups according to the laser irradiation protocol (without irradiation, irradiated at 1.5 W and irradiated at 3.0 W). Two specimens of each subgroup were prepared for SEM. The remaining roots were filled with AH Plus and gutta-percha. Apical leakage was assessed by ink penetration and data were analyzed statistically by ANOVA and Tukey-Krammer test (α=0.05). SEM analysis showed intensification of changes with increase of laser power as well as variations according to the irrigating solution. Modified smear layer was observed in specimens treated with water and irradiated with laser. Roots irrigated with NaOCl/EDTA had lower levels of infiltration (0.17 ± 0.18 mm) differing significantly (p<0.05) from those of roots irrigated with water (0.34 ± 0.30 mm), but similar (p>0.05) to those irrigated with NaOCl (0.28 ± 0.29 mm). Non-irradiated roots had lower levels of infiltration (0.10 ± 0.14 mm), differing (p<0.05) from those irradiated at 1.5 W (0.32 ± 0.22 mm) and 3.0 W (0.37 ± 0.32 mm). The 980 nm diode laser modified dentin morphology and increased apical microleakage.


Asunto(s)
Filtración Dental/clasificación , Cavidad Pulpar/efectos de la radiación , Dentina/efectos de la radiación , Láseres de Semiconductores/uso terapéutico , Ápice del Diente/efectos de la radiación , Colorantes , Diente Canino/efectos de la radiación , Diente Canino/ultraestructura , Recubrimiento Dental Adhesivo , Cavidad Pulpar/ultraestructura , Dentina/ultraestructura , Ácido Edético/uso terapéutico , Resinas Epoxi/uso terapéutico , Gutapercha/uso terapéutico , Humanos , Incisivo/efectos de la radiación , Incisivo/ultraestructura , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Dosis de Radiación , Materiales de Obturación del Conducto Radicular/uso terapéutico , Irrigantes del Conducto Radicular/uso terapéutico , Preparación del Conducto Radicular/métodos , Capa de Barro Dentinario , Hipoclorito de Sodio/uso terapéutico , Ápice del Diente/ultraestructura , Agua
13.
Braz Dent J ; 22(4): 317-21, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21861032

RESUMEN

This study assessed the effect of bleaching protocols with 38% hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukey's test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p>0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p>0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p<0.05). The restorative procedure of intracoronary dentin bleached with 38% HP with or without the use of light source should be performed after at least 10 days after the bleaching treatment.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina/ultraestructura , Peróxido de Hidrógeno/química , Oxidantes/química , Blanqueadores Dentales/química , Grabado Ácido Dental/métodos , Bisfenol A Glicidil Metacrilato/química , Resinas Compuestas/química , Análisis del Estrés Dental/instrumentación , Recubrimientos Dentinarios/química , Humanos , Láseres de Semiconductores , Ensayo de Materiales , Ácidos Fosfóricos/química , Resistencia al Corte , Estrés Mecánico , Factores de Tiempo , Blanqueamiento de Dientes/métodos
14.
RGO (Porto Alegre) ; 59(supl.1): 7-13, Abr.-Jun. 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-766061

RESUMEN

Devido ao aumento da incidência e prevalência da erosão dental, torna-se importante abordar e discutir sua etiopatogenia e tratamento. Para preservar ao máximo a estrutura dental, é essencial que o profissional da área odontológica esteja apto para detectar os fatores e os comportamentos de risco, diagnosticar as lesões em estágios iniciais e instituir estratégias preventivas contra a formação de novas lesões e de controle da progressão daquelas já presentes. É fundamental que o conceito de erosão dental, os fatores etiológicos que podem estar envolvidos no processo patológico e as possíveis interações com outros fenômenos de desgaste sejam esclarecidos. Dessa forma, o objetivo desta revisão é apresentar a definição e a etiologia da erosão dental e discutir possíveis estratégias de tratamento e seus mecanismos de ação na prevenção e no controle do desenvolvimento da erosão dental.


Objetivo Owing to the increased incidence and prevalence of dental erosion, it is important to broach and discuss its etiopathogenesis and management. For maximal preservation of dental structures, practitioners must be able to recognize risk factors and behaviors for dental erosion, diagnose initial lesions and implement preventive and interceptive strategies. Therefore, clarification of dental erosion, its likely etiology and interactions with other wear process are of outmost relevance. The aims of this literature review paper are: to present the definition and etiology of dental erosion and to discuss strategies and their mechanism of action in preventing and controlling dental erosion.


Asunto(s)
Erosión
15.
Braz Dent J ; 22(2): 117-21, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21537584

RESUMEN

This study evaluated the fracture resistance of teeth submitted to internal bleaching and restored with different procedures. Forty maxillary incisors were endodontically treated and assigned to 4 groups (n=10): G1- restored with composite resin (CR), G2- bleached with hydrogen peroxide (HP) and restored with CR, G3- restored with CR and fiberglass posts (CR + posts) and G4- bleached and restored with CR + posts. HP was applied in the buccal surface and pulp chamber 3 times at each one of 2 sessions with an interval of 7 days between them. Additional 10 sound incisors were subjected to fracture strength test (gold standard). The fracture strength (kN) was determined in an Instron machine. Data were analyzed by ANOVA and Tukey-Kramer test (α=0.05). The untreated teeth (gold standard) showed the highest (p.


Asunto(s)
Restauración Dental Permanente/métodos , Técnica de Perno Muñón , Blanqueamiento de Dientes/métodos , Fracturas de los Dientes/prevención & control , Diente no Vital/fisiopatología , Análisis de Varianza , Resinas Compuestas , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Vidrio , Humanos , Peróxido de Hidrógeno/administración & dosificación , Estadísticas no Paramétricas , Blanqueadores Dentales/administración & dosificación , Fracturas de los Dientes/etiología
16.
Braz. dent. j ; 22(5): 382-387, 2011. ilus, tab
Artículo en Inglés | LILACS | ID: lil-601838

RESUMEN

This study evaluated the effect of 980-nm diode laser on apical microleakage and intraradicular dentin morphology. Roots of 110 mandibular incisors were used in the study: 92 for microleakage test and 18 for scanning electron microscopy (SEM). Roots were randomly assigned to 3 groups according to the irrigating solution (water, NaOCl and NaOCl/EDTA) and were divided into 3 subgroups according to the laser irradiation protocol (without irradiation, irradiated at 1.5 W and irradiated at 3.0 W). Two specimens of each subgroup were prepared for SEM. The remaining roots were filled with AH Plus and gutta-percha. Apical leakage was assessed by ink penetration and data were analyzed statistically by ANOVA and Tukey-Krammer test (α=0.05). SEM analysis showed intensification of changes with increase of laser power as well as variations according to the irrigating solution. Modified smear layer was observed in specimens treated with water and irradiated with laser. Roots irrigated with NaOCl/EDTA had lower levels of infiltration (0.17 ± 0.18 mm) differing significantly (p<0.05) from those of roots irrigated with water (0.34 ± 0.30 mm), but similar (p>0.05) to those irrigated with NaOCl (0.28 ± 0.29 mm). Non-irradiated roots had lower levels of infiltration (0.10 ± 0.14 mm), differing (p<0.05) from those irradiated at 1.5 W (0.32 ± 0.22 mm) and 3.0 W (0.37 ± 0.32 mm). The 980 nm diode laser modified dentin morphology and increased apical microleakage.


Este estudo avaliou o efeito do laser de diodo 980 nm na microinfiltração apical e na morfologia intrarradicular da dentina. Raízes de 110 incisivos inferiores foram utilizadas no estudo: 92 para o teste de microinfiltração e 18 para microscopia eletrônica de varredura (MEV). As raízes foram divididas em 3 grupos de acordo com a solução irrigante (água, NaOCl e NaOCl/EDTA) e subdivididas em 3 de acordo com a irradiação laser (sem irradiação, irradiados com 1,5 W e irradiados com 3,0 W). Duas amostras de cada subgrupo foram preparadas para MEV. As raízes restantes foram preenchidas com AH Plus e guta percha. A infiltração apical foi avaliada nas raízes por meio da penetração do corante e os dados foram analisados por ANOVA e teste de Tukey-Krammer (α=0,05). Os resultados da MEV mostraram intensificação das mudanças quando se aumentou a potência do laser e variações de acordo com a solução irrigadora. Camada de smear modificada foi observada em espécimes tratados com água e irradiados com laser. Raízes irrigadas com NaOCl/EDTA tiveram níveis menores de infiltração (0,17 ± 0,18 mm) estatisticamente diferente (p<0,05) das raízes irrigadas com água (0,34 ± 0,30 mm), mas semelhante (p>0,05) aos irrigados com NaOCl (0,28 ± 0,29 mm). As raízes não irradiadas tiveram níveis menores de infiltração (0,10 ± 0,14 mm), diferente (p<0,05) de 1,5 W (0,32 ± 0,22 mm) e 3.0 W (0,37 ± 0,32 mm). O laser de diodo 980 nm alterou a morfologia da dentina e aumentou a infiltração marginal apical.


Asunto(s)
Humanos , Filtración Dental/clasificación , Cavidad Pulpar/efectos de la radiación , Dentina/efectos de la radiación , Láseres de Semiconductores/uso terapéutico , Ápice del Diente/efectos de la radiación , Colorantes , Diente Canino/efectos de la radiación , Diente Canino/ultraestructura , Recubrimiento Dental Adhesivo , Cavidad Pulpar/ultraestructura , Dentina/ultraestructura , Ácido Edético/uso terapéutico , Resinas Epoxi/uso terapéutico , Gutapercha/uso terapéutico , Incisivo/efectos de la radiación , Incisivo/ultraestructura , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Dosis de Radiación , Materiales de Obturación del Conducto Radicular/uso terapéutico , Irrigantes del Conducto Radicular/uso terapéutico , Preparación del Conducto Radicular/métodos , Capa de Barro Dentinario , Hipoclorito de Sodio/uso terapéutico , Ápice del Diente/ultraestructura , Agua
17.
Braz. dent. j ; 22(4): 317-321, 2011. tab
Artículo en Inglés | LILACS | ID: lil-595663

RESUMEN

This study assessed the effect of bleaching protocols with 38 percent hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukey's test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p>0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p>0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p<0.05). The restorative procedure of intracoronary dentin bleached with 38 percent HP with or without the use of light source should be performed after at least 10 days after the bleaching treatment.


Este estudo avaliou o efeito de protocolos de clareamento com peróxido de hidrogênio 38 por cento (PH) e tempos pós-clareamento na resistência ao cisalhamento de uma resina composta á dentina. Cem fragmentos de dentina intracoronária foram incluídos e distribuídos aleatoriamente em 2 grupos experimentais de acordo com o protocolo de clareamento: PH (2 aplicações de 10 min cada) e HP ativado por LED laser (2 aplicações de 10 min cada/45 s de ativação pela luz). Os grupos foram subdivididos de acordo com o tempo pós-clareamento (n=10): 1 dia, 3 dias, 7 dias, 10 dias e 14 dias. O grupo controle não foi clareado e apenas restaurado (n=10). Os espécimes foram restaurados com sistema adesivo Single Bond/resina Filtek Z250 usando matriz de teflon. Após 24 h, foram submetidos ao teste de cisalhamento. Os dados foram analisados por ANOVA e teste de Tukey (α=0,05). O grupo não clareado (0,283 ± 0,134) apresentou a maior resistência de união e foi estatisticamente semelhante (p>0,05) ao PH- 10 dias (0,278 ± 0,064), PH + LED laser/10 dias (0,280 ± 0,078), PH/14 dias (0,281 ± 0,104), PH + LED laser/14 dias (0,277 ± 0,093). Resistência de união inferior foram verificadas para PH/1 dia (0,082 ± 0,012), PH/3 dias (0,079 ± 0,013), PH + LED laser/1 dia (0,073 ± 0,018) e PH + LED laser/3 dias (0,080 ± 0,015), que foram estatisticamente semelhantes entre si (p>0,05). HP/7 dias (0,184 ± 0,154) e PH + LED laser/7 dias (0,169 ± 0,102) apresentaram valores intermediários (p<0,05). O procedimento restaurador da dentina intracoronária clareada com peróxido de hidrogênio 38 por cento, com ou sem o uso de fonte de luz, deve ser realizado pelo menos após 10 dias do tratamento clareador.


Asunto(s)
Humanos , Recubrimiento Dental Adhesivo , Dentina/ultraestructura , Peróxido de Hidrógeno/química , Oxidantes/química , Blanqueadores Dentales/química , Grabado Ácido Dental/métodos , Bisfenol A Glicidil Metacrilato/química , Resinas Compuestas/química , Análisis del Estrés Dental/instrumentación , Recubrimientos Dentinarios/química , Láseres de Semiconductores , Ensayo de Materiales , Ácidos Fosfóricos/química , Resistencia al Corte , Estrés Mecánico , Factores de Tiempo , Blanqueamiento de Dientes/métodos
18.
Braz. dent. j ; 22(2): 117-121, 2011. tab
Artículo en Inglés | LILACS | ID: lil-583799

RESUMEN

This study evaluated the fracture resistance of teeth submitted to internal bleaching and restored with different procedures. Forty maxillary incisors were endodontically treated and assigned to 4 groups (n=10): G1- restored with composite resin (CR), G2- bleached with hydrogen peroxide (HP) and restored with CR, G3- restored with CR and fiberglass posts (CR + posts) and G4- bleached and restored with CR + posts. HP was applied in the buccal surface and pulp chamber 3 times at each one of 2 sessions with an interval of 7 days between them. Additional 10 sound incisors were subjected to fracture strength test (gold standard). The fracture strength (kN) was determined in an Instron machine. Data were analyzed by ANOVA and Tukey-Kramer test (α=0.05). The untreated teeth (gold standard) showed the highest (p<0.05) fracture strength (0.43 ± 0.16). Teeth restored with CR (G1) without internal bleaching had the lowest (p<0.05) fracture strength (0.23 ± 0.11). Teeth bleached and restored with CR (G2) (0.26 ± 0.10), restored with CR + posts ithout internal bleaching (G3) (0.31 ± 0.17) and, bleached and restored with CR + posts (G4) (0.33 ± 0.12) had intermediate values, sometimes similar to the group with the highest value, sometimes similar to the group with the lowest value. In conclusion, as far as the fracture strength is concerned, teeth subjected to internal bleaching can be restored with composite resin alone, as the use of posts in these teeth did not increase their resistance.


Este estudo avaliou a resistência à fratura de dentes submetidos ao clareamento interno restaurados com diferentes procedimentos. Quarenta incisivos superiores foram tratados endodonticamente e divididos em 4 grupos (n = 10): G1- restaurados com resina composta (RC), G2- clareados com peróxido de hidrogênio (PH) e restaurados com o RC, G3- restaurado com RC e pinos de fibra de vidro (RC + pinos) e G4- clareados e restaurados com RC + pinos. O PH foi aplicado na superfície vestibular e câmara pulpar 3 vezes por sessão, por 2 sessões com intervalo de 7 dias entre elas. Dez dentes hígidos adicionais foram submetidos a teste fratura (padrão ouro). A resistência à fratura (kN) foi determinada em máquina Instron. Os dados foram analisados por Análise de Variânica e teste de Tukey-Krammer (α= 0,05). Os dentes não tratados (padrão ouro) apresentaram a maior resistência à fratura (0,43 ± 0,16) (p <0,05). Os dentes restaurados com RC (G1) apresentaram a menor resistência à fratura (0,23 ± 0,11) (p <0,05). Os dentes clareados e restaurados com RC (G2) (0,26 ± 0,10), restaurado com RC + pinos (G3) (0,31 ± 0,17) e os clareados e restaurados com RC + pinos (G4) (0,33 ± 0,12) apresentaram valores intermediários, ora semelhantes ao do grupo com o maior valor, ora similares ao grupo de valores mais baixos. Pode-se concluir que os dentes submetidos ao clareamento interno podem ser restaurados com apenas resina composta.


Asunto(s)
Humanos , Restauración Dental Permanente/métodos , Técnica de Perno Muñón , Blanqueamiento de Dientes/métodos , Fracturas de los Dientes/prevención & control , Diente no Vital/fisiopatología , Análisis de Varianza , Resinas Compuestas , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Vidrio , Peróxido de Hidrógeno/administración & dosificación , Estadísticas no Paramétricas , Blanqueadores Dentales/administración & dosificación , Fracturas de los Dientes/etiología
19.
RFO UPF ; 15(3)set.-dez. 2010.
Artículo en Portugués | LILACS | ID: lil-586962

RESUMEN

O entendimento do papel dos aspectos físico-químicos relacionados ao caráter erosivo de bebidas ácidas contribui para fundamentar estratégias que visem minimizar a formação e progressão de lesões de erosão. Objetivo: Este trabalho visou revisar o papel de aspectos relacionados ao potencial erosivo de bebidas ácidas, esclarecendo como o tipo, concentração e propriedades quelantes do ácido que as compõem, pH, acidez titulável, conteúdo de cálcio, fosfato e flúor, presença de caseína, temperatura e adesividade das bebidas, influenciam, de forma isolada ou combinada, no des-gaste dental. Revisão de literatura: Realizada mediante pesquisa em indexadores internacional (Medline) e nacional (BBO) e em um livro. Buscaram-se evidências sobre o tema em artigos de investigação cientifica e de revisão de literatura. Considerações finais: Concluiu-se que: 1) o tipo e o potencial quelante do ácido, o pH, a acidez titulável, as concentrações de cálcio e fosfato, a temperatura e a adesividade das bebidas modulam seu potencial erosivo; 2) individualmente, o pH, acidez titulável e conteúdo de cálcio são os parâmetros que melhor revelam a capacidade das bebidas em propor-cionar a dissolução mineral da estrutura dental; 3) para uma caracterização mais precisa do potencial erosivo de bebidas ácidas, deve-se considerar a interação entre os diferentes aspectos físico-químicos.

20.
Rev. odontol. UNESP (Online) ; 39(4): 241-245, jul.-ago. 2010.
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-874537

RESUMEN

Os dois principais transtornos alimentares evidenciados na clínica contemporânea são anorexia e bulimia nervosas. Entretanto, outras anormalidades do comportamento alimentar em que os critérios necessários para o diagnóstico de anorexia e bulimia não são preenchidos, recebem a denominação de transtorno alimentar "atípico", como o transtorno da compulsão alimentar periódica e a síndrome do comer noturno. Com o intuito de preservar a estrutura dental, minimizando os danos bucais, é indispensável que, inserido na equipe multiprofissional de tratamento desta patologia, o cirurgião-dentista possa diagnosticar as manifestações associadas especificamente aos determinados tipos de desordens alimentares. Detectar as lesões nos tecidos bucais em estágios iniciais, instituir estratégias preventivas contra o desenvolvimento de novas lesões e controlar a progressão daquelas já presentes contribui para o tratamento completo do indivíduo. Para isso, previamente à apresentação das manifestações bucais, é fundamental apresentar conceitos, características e sintomas específicos dos transtornos alimentares. Dessa forma, o objetivo desta revisão de literatura, desenvolvida a partir de referências bibliográficas encontradas através de pesquisa nas bases de dados Medline e Lilacs é apresentar características, sinais e sintomas dos transtornos alimentares e associar as suas manifestações na cavidade bucal. Concluiu-se que o dentista apresenta papel importante na detecção das manifestações bucais dos transtornos alimentares e pode auxiliar no diagnóstico dos distúrbios e no tratamento do indivíduo.


The two main eating disorders in the contemporary clinical practice are anorexia and bulimia nervosa. However, other disturbs of eating behavior, not diagnosed as anorexia and bulimia, are called "atypical" eating disorders such as binge eating disorder and night eating syndrome. Aiming to preserve the tooth structure minimizing the damages is essential that the dentist, inserted in the multidisciplinary team of treatment of eating disorders, diagnoses the manifestations associated to specific eating disorders. To detect lesions in the oral cavity in early stages, to institute preventive strategies against the development of new lesions and to control the progression of those already present contributes to the complete treatment of the individual. For that, prior to the presentation of the oral manifestations, it is crucial that concepts, characteristics and specific symptoms of eating disorders are descripted. The purpose of this review is to present the signs and symptoms of eating disorders and associate its manifestations in the oral cavity. For this, the data base Medline and Lilacs were accessed and relevant references were used. It was conclude that the dentist had important participation in the detection of the oral manifestations of eating disorders and may contributes to diagnosis the disturbs and to treat the patient.


Asunto(s)
Humanos , Grupo de Atención al Paciente , Anorexia Nerviosa , Trastornos de Alimentación y de la Ingestión de Alimentos/prevención & control , Bulimia Nerviosa , Boca , Manifestaciones Bucales , MEDLINE , LILACS
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...