Resultados 1 - 20 de 145
Filtrar
1.
J Appl Clin Med Phys ; : e14370, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38661097

RESUMEN

PURPOSE: To evaluate the accuracy of different dosimeters and the treatment planning system (TPS) for assessing the skin dose due to the electron streaming effect (ESE) on a 1.5 T magnetic resonance (MR)-linac. METHOD: Skin dose due to the ESE on an MR-linac (Unity, Elekta) was investigated using a solid water phantom rotated 45° in the x-y plane (IEC61217) and centered at the isocenter. The phantom was irradiated with 1 × 1, 3 × 3, 5 × 5, 10 × 10, and 22 × 22 cm2 fields, gantry at 90°. Out-of-field doses (OFDs) deposited by electron streams generated at the entry and exit surface of the angled phantom were measured on the surface of solid water slabs placed ±20.0 cm from the isocenter along the x-direction. A high-resolution MOSkin™ detector served as a benchmark due to its shallower depth of measurement that matches the International Commission on Radiological Protection (ICRP) recommended depth for skin dose assessment (0.07 mm). MOSkin™ doses were compared to EBT3 film, OSLDs, a diamond detector, and the TPS where the experimental setup was modeled using two separate calculation parameters settings: a 0.1 cm dose grid with 0.2% statistical uncertainty (0.1 cm, 0.2%) and a 0.2 cm dose grid with 3.0% statistical uncertainty (0.2 cm, 3.0%). RESULTS: OSLD, film, the 0.1 cm, 0.2%, and 0.2 cm, 3.0% TPS ESE doses, underestimated skin doses measured by the MOSkin™ by as much as -75.3%, -7.0%, -24.7%, and -41.9%, respectively. Film results were most similar to MOSkin™ skin dose measurements. CONCLUSIONS: These results show that electron streams can deposit significant doses outside the primary field and that dosimeter choice and TPS calculation settings greatly influence the reported readings. Due to the steep dose gradient of the ESE, EBT3 film remains the choice for accurate skin dose assessment in this challenging environment.

2.
Can Urol Assoc J ; 18(2): 48-54, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37931281

RESUMEN

INTRODUCTION: This research evaluates the utility and precision of point-of-care ultrasound (POCUS) in urology, inspired by recent affirmations of its feasibility and value.1,2 Our study provides valuable insights for urologists about POCUS's practical usage. METHODS: A prospective study assessed POCUS usage and accuracy in the University of Alberta's Division of Urology using data from April 4, 2022, to April 4, 2023. Data include POCUS indications, findings, and correlation with the final diagnosis/gold standard. Additionally, a qualitative survey was conducted among urologists and residents about POCUS's pros, cons, and barriers to integration. RESULTS: Thirty-three patients underwent POCUS examinations, mainly for suspected hydronephrosis (27%, n=9). Other indications included urinary retention, testicular mass, torsion, cryptorchidism, renal mass, extended focused assessment with sonography in trauma (eFAST ) exams, nephrostomy tube placement confirmation, and scrotal hematomas. POCUS findings matched the final diagnosis in most cases, showing 86% sensitivity, with an average exam time of 1-5 minutes. POCUS showed potential for suprapubic tube insertions. Residents (60%, n=20) were the most frequent users, followed by staff (33%, n=10), and students (6%, n=2). The surveyed urologists and residents expressed comfort with POCUS but cited time, cost, and practicality as barriers. CONCLUSIONS: POCUS proves accurate and beneficial in urology, particularly for hydronephrosis. Most findings align with the gold standard, and the average exam time is brief. Barriers include time and cost. Further research is necessary to evaluate cost-effectiveness and POCUS's impact on patient outcomes in routine urologic practice.

3.
J Pediatr Rehabil Med ; 16(4): 605-619, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38073338

RESUMEN

PURPOSE: This study aimed to analyze organ system-based causes and non-organ system-based mechanisms of death (COD, MOD) in people with myelomeningocele (MMC), comparing urological to other COD. METHODS: A retrospective review was performed of 16 institutions in Canada/United States of non-random convenience sample of people with MMC (born > = 1972) using non-parametric statistics. RESULTS: Of 293 deaths (89% shunted hydrocephalus), 12% occurred in infancy, 35% in childhood, and 53% in adulthood (documented COD: 74%). For 261 shunted individuals, leading COD were neurological (21%) and pulmonary (17%), and leading MOD were infections (34%, including shunt infections: 4%) and non-infectious shunt malfunctions (14%). For 32 unshunted individuals, leading COD were pulmonary (34%) and cardiovascular (13%), and leading MOD were infections (38%) and non-infectious pulmonary (16%). COD and MOD varied by shunt status and age (p < = 0.04), not ambulation or birthyear (p > = 0.16). Urology-related deaths (urosepsis, renal failure, hematuria, bladder perforation/cancer: 10%) were more likely in females (p = 0.01), independent of age, shunt, or ambulatory status (p > = 0.40). COD/MOD were independent of bladder augmentation (p = >0.11). Unexplained deaths while asleep (4%) were independent of age, shunt status, and epilepsy (p >= 0.47). CONCLUSION: COD varied by shunt status. Leading MOD were infectious. Urology-related deaths (10%) were independent of shunt status; 26% of COD were unknown. Life-long multidisciplinary care and accurate mortality documentation are needed.


Asunto(s)
Hidrocefalia , Meningomielocele , Femenino , Humanos , Meningomielocele/complicaciones , Meningomielocele/cirugía , Estudios Retrospectivos , Causas de Muerte , Derivación Ventriculoperitoneal/efectos adversos , Hidrocefalia/cirugía
4.
Can Urol Assoc J ; 2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37787594

RESUMEN

INTRODUCTION: Competency in interpreting genitourinary (GU) imaging is an important skill for urologists; however, no nationally accredited GU imaging curriculum exists for Canadian urology residency training programs. The main objectives of our study were to 1) characterize GU imaging training in Canada; (2) evaluate residents' self-perceived competencies in interpreting GU imaging; (3) explore program directors' (PD) and residents' perceptions regarding the current imaging curriculum and suggestions for future directions. METHODS: From November to December 2022, a survey examining current imaging education in residency, perceived resident imaging knowledge, avenues for improvement in imaging education, and the role of point-of-care ultrasound within urology was distributed to all Canadian urology PDs and residents. RESULTS: All PDs (13/13) and 40% (72/178) of residents completed the survey. Only two programs had a formal GU imaging curriculum. PDs and residents reported trainees were least comfortable interpreting Doppler ultrasound of renal, gonadal, and penile vessels. PDs reported that residents were most comfortable with non-contrast computed tomography (CT) scans (9.5/10), CT urogram (9.3/10), and retrograde pyelography (9.3/10). All but one PD favored increasing imaging training in their program. PDs highlighted the lack of time in the curriculum (n=3) and lack of educators (n=3) as the primary barriers to increasing imaging training in their program. CONCLUSIONS: Most PDs and residents believe there needs to be more imaging training offered at their institution; however, addressing this is challenging due to the limited time in the curriculum and the need for available educators.

5.
J Pediatr Urol ; 19(4): 407.e1-407.e5, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37130762

RESUMEN

BACKGROUND: Constipation is common in the pediatric population and in severe forms it can lead to debilitating fecal incontinence which has a significant impact on quality of life. Cecostomy tube insertion is a procedural option for cases refractory to medical management, however there is limited data investigating the long-term success and complication rate. METHODS: A retrospective review was performed evaluating patients at our centre undergoing cecostomy tube (CT) insertion between 2002 and 2018. The primary outcomes of the study were the rate of fecal continence at 1-year, and the incidence of unplanned exchanges prior to annual scheduled exchange. Secondary outcomes include the frequency of anaesthetic requirements and length of hospital stay. Descriptive statistics, t-test, and chi-square analysis was performed where appropriate using SPSS v25. RESULTS: Of 41 patients, the average age at the time of initial insertion was 9.9 years with the average length of stay in hospital being 3.47 days. The most common etiology of bowel dysfunction was spina bifida, which was present in 48.8% (n = 20) of patients. Fecal continence was achieved in 90% (n = 37) of patients at 1 year and the average rate of cecostomy tube exchange was 1.3/year with an average of 3.6 general anaesthetics being required by patients and the average age of no longer requiring one being 14.9 years. DISCUSSION: Analysis of patients undergoing cecostomy tube insertion at our centre has further supported the use of cecostomy tubes as a safe and effective option for management of fecal incontinence refractory to medical management. However, a number of limitations exist in this study including its retrospective design and failure to investigate changes in quality of life using validated questionnaires. Additionally, while our research provides greater insight to practitioners and patients what degree of care and types of complications or issues they may encounter with an indwelling tube over the long-term, our single-cohort design limits any conclusions that could be made regarding optimal management strategies for overflow fecal incontinence through direct comparison with other management strategies. CONCLUSIONS: CT insertion is a safe and effective method for managing fecal incontinence due to constipation in the pediatric population, however, unplanned exchange of tube due to malfunction, mechanical breakage, or dislodgment occurs frequently and may impact quality of life and independence. LEVEL OF EVIDENCE: IV.


Asunto(s)
Cecostomía , Incontinencia Fecal , Humanos , Niño , Adolescente , Cecostomía/efectos adversos , Cecostomía/métodos , Estudios Retrospectivos , Incontinencia Fecal/etiología , Incontinencia Fecal/cirugía , Calidad de Vida , Enema/métodos , Estreñimiento/etiología , Estreñimiento/cirugía , Resultado del Tratamiento
7.
Can Urol Assoc J ; 17(5): E110-E115, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36758185

RESUMEN

INTRODUCTION: Adolescent males are particularly prone to testicular torsion, often resulting in subsequent orchiectomy. A lack of knowledge about testicular pathologies, as well as hesitancy to discuss genital concerns, are fundamental, preventable barriers to early presentation. We hypothesized that a social media campaign to improve awareness of testicular torsion and other urological conditions affecting adolescents may overcome such barriers in this population. METHODS: A social media campaign, "Teste Talk," was created and promoted on Instagram and Facebook. Data was collected from June 1 to December 1, 2021. Instagram followers, Facebook page likes, Instagram and Facebook reach, post likes, Instagram follower demographics, and advertisement data were reviewed. Data was collected using Meta Business Suite. Paid promotions to improve awareness of the campaign were targeted towards 13-18-year-old males in Alberta and were funded by the Undergraduate Research Initiative Support Fund. RESULTS: The campaign reached 26 072 Instagram accounts and 14 741 Facebook accounts. The Instagram page amassed 382 followers, while the Facebook page accumulated 99 likes. Paid advertisements were seen 81 136 times on Instagram and Facebook. Instagram surveys demonstrated that over the study period, followers had an increased awareness of testicular torsion and how to recognize it. No patients presenting with torsion during the study period admitted to seeing the campaign. CONCLUSIONS: Testicular torsion remains a significant issue among adolescent males, and creative ways to disseminate information and increase knowledge and conversations about testicular pathologies are needed. Social media campaigns present a potential pathway for increasing awareness and reducing delays to presentation and orchiectomies.

8.
J Pediatr Urol ; 19(1): 86.e1-86.e6, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36336623

RESUMEN

PURPOSE: The Anderson-Hynes technique has been the treatment of choice for primary ureteropelvic junction obstruction in children. Laparoscopic approach has shown similar outcomes to open, with advantages of shorter hospital stay and less pain. We reviewed the experience of 11 geographically diverse, tertiary pediatric urology institutions focusing on the outcomes and complications of laparoscopic pyeloplasty. MATERIALS AND METHODS: A descriptive, retrospective study was conducted evaluating patients undergoing Anderson-Hynes dismembered laparoscopic pyeloplasty. Centers from four different continents participated. Demographic data, perioperative management, results, and complications are described. RESULTS: Over a 9-year period, 744 laparoscopic pyeloplasties were performed in 743 patients. Mean follow-up was 31 months (6-120m). Mean age at surgery was 82 months (1 w-19 y). Median operative time was 177 min. An internal stent was placed in 648 patients (87%). A catheter was placed for bladder drainage in 702 patients (94%). Conversion to open pyeloplasty was necessary in seven patients. Average length of hospital stay was 2.8 days. Mean time of analgesic requirement was 3.2 days. Complications, according to Clavien-Dindo classification, were observed in 56 patients (7.5%); 10 (1%) were Clavien-Dindo IIIb. Treatment failure occurred in 35 cases with 30 requiring redo pyeloplasty (4%) and 5 cases requiring nephrectomy (0.6%). CONCLUSION: We have described the laparoscopic pyeloplasty experience of institutions with diverse cultural and economic backgrounds. They had very similar outcomes, in agreement with previously published data. Based on these findings, we conclude that laparoscopic pyeloplasty is safe and successful in diverse geographics areas of the world.


Asunto(s)
Laparoscopía , Obstrucción Ureteral , Niño , Humanos , Actitud , Pelvis Renal/cirugía , Laparoscopía/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Obstrucción Ureteral/cirugía , Obstrucción Ureteral/etiología , Procedimientos Quirúrgicos Urológicos/métodos
9.
Cancers (Basel) ; 14(16)2022 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-36010891

RESUMEN

Radiomics is a field of medical imaging analysis that focuses on the extraction of many quantitative imaging features related to shape, intensity and texture. These features are incorporated into models designed to predict important clinical or biological endpoints for patients. Attention for radiomics research has recently grown dramatically due to the increased use of imaging and the availability of large, publicly available imaging datasets. Glioblastoma multiforme (GBM) patients stand to benefit from this emerging research field as radiomics has the potential to assess the biological heterogeneity of the tumour, which contributes significantly to the inefficacy of current standard of care therapy. Radiomics models still require further development before they are implemented clinically in GBM patient management. Challenges relating to the standardisation of the radiomics process and the validation of radiomic models impede the progress of research towards clinical implementation. In this manuscript, we review the current state of radiomics in GBM, and we highlight the barriers to clinical implementation and discuss future validation studies needed to advance radiomics models towards clinical application.

10.
J Pediatr Genet ; 11(2): 139-143, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35769967

RESUMEN

Plexiform neurofibroma (PN) involvement of the external genitalia in patients with neurofibromatosis type I (NF1) is a rare cause of nonhormonal clitoromegaly. We present a 3-year-old female with known NF1 who presented with clitoromegaly. She was identified with an extensive pelvic mass involving the bladder wall, perineum, labia, clitoris, rectum, and sacral foramina. A partial cystectomy was performed, and histopathology was consistent with PN. She has been initiated on a mitogen activated protein kinase enzyme kinase inhibitor, trametinib, which has been effective in achieving partial radiographic response of the bladder mass over 5 months. Additionally, she has experienced clinical response to trematinib with resolution of urinary urgency and frequency since initiating treatment.

11.
J Appl Clin Med Phys ; 23(6): e13625, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35522240

RESUMEN

PURPOSE: Computational dosimetry software is routinely used to evaluate the organ and effective doses from computed tomography (CT) examinations. Studies have shown a significant variation in dose estimates between software in adult cohorts, and few studies have evaluated software for pediatric dose estimates. This study aims to compare the primary organ and effective doses estimated by four commercially available CT dosimetry software to thermoluminescent dosimeter (TLD) measurements in a 1-year-old phantom. METHODS: One hundred fifteen calibrated LiF (Mg, Cu, P)-TLD 100-H chips were embedded within an anthropomorphic phantom representing a 1-year-old child at positions that matched the approximate location of organs within an infant. The phantom was scanned under three protocols, each with whole-body coverage. The mean absorbed doses from 25 radiosensitive organs and skeletal tissues were determined from the TLD readings. Effective doses for each of the protocols were subsequently calculated using ICRP 103 formalism. Dose estimates by the four Monte Carlo-based dose calculation systems were determined and compared to the directly measured doses. RESULTS: Most organ doses determined by computation dosimetry software aligned to phantom measurements within 20%. Additionally, comparisons between effective doses are calculated using computational and direct measurement methods aligned within 20% across the three protocols. Significant variances were found in bone surface dose estimations among dosimetry methods, likely caused by differences in bone tissue modeling. CONCLUSION: All four-dosimetry software evaluated in this study provide adequate primary organ and effective dose estimations. Users should be aware, however, of the possible estimated uncertainty associated with each of the programs.


Asunto(s)
Radiometría , Tomografía Computarizada por Rayos X , Adulto , Niño , Humanos , Lactante , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos
12.
Can Urol Assoc J ; 16(6): 212, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35623002
13.
Med Phys ; 49(7): 4508-4517, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35365884

RESUMEN

PURPOSE: To assess the technical performance of the apparent diffusion coefficient (ADC) on a dedicated 3T radiotherapy scanner, using a standardized phantom and sequences. Investigations into factors that could impact the technical performance of ADC in the clinic were also completed, including changing the slice-encoded imaging direction and the reference sample ADC value. METHODS: ADC acquisitions were performed monthly on an isotropic diffusion phantom over 1 year. Measurements of ADC %bias, coefficients of variation for short-/long-term repeatability and precision (CVST /CVLT and CVP ), and b-value dependency (Depb ) were calculated. The measurements were then assessed according to the Quantitative Imaging Biomarker Alliance (QIBA) Diffusion Profile specifications. RESULTS: The average of all measurements over the year was within Profile recommended ranges. This included when testing was performed in different imaging directions, and on samples that had different ADC reference values (0.4-1.1 µm2 /ms). Results in the axial plane for the central water vial included a bias of +0.05%, CVST /CVLT /CVP  = 0.1%/ 0.9%/0.4% and Depb  = 0.4%. CONCLUSIONS: The technical performance of ADC on a radiotherapy dedicated MRI scanner over the course of 12 months was considered conformant to the QIBA Profile. Quantifying these metrics and factors that may affect the performance is essential in progressing the use of ADC clinically: ensuring that the observed change of ADC in a tissue is due to a physiological response and not measurement variability.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Biomarcadores , Imagen de Difusión por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados
14.
J Appl Clin Med Phys ; 23(6): e13591, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35333000

RESUMEN

PURPOSE: The aim of this study is to investigate off-axis irradiation on the Australian MRI-Linac using experiments and Monte Carlo simulations. Simulations are used to verify experimental measurements and to determine the minimum offset distance required to separate electron contamination from the photon field. METHODS: Dosimetric measurements were performed using a microDiamond detector, Gafchromic® EBT3 film, and MOSkinTM . Three field sizes were investigated including 1.9 × 1.9, 5.8 × 5.8, and 9.7 × 9.6 cm2 . Each field was offset a maximum distance, approximately 10 cm, from the central magnetic axis (isocenter). Percentage depth doses (PDDs) were collected at a source-to-surface distance (SSD) of 1.8 m for fields collimated centrally and off-axis. PDD measurements were also acquired at isocenter for each off-axis field to measure electron contamination. Monte Carlo simulations were used to verify experimental measurements, determine the minimum field offset distance, and demonstrate the use of a spoiler to absorb electron contamination. RESULTS: Off-axis irradiation separates the majority of electron contamination from an x-ray beam and was found to significantly reduce in-field surface dose. For the 1.9 × 1.9, 5.8 × 5.8, and 9.7 × 9.6 cm2 field, surface dose was reduced from 120.9% to 24.9%, 229.7% to 39.2%, and 355.3% to 47.3%, respectively. Monte Carlo simulations generally were within experimental error to MOSkinTM and microDiamond, and used to determine the minimum offset distance, 2.1 cm, from the field edge to isocenter. A water spoiler 2 cm thick was shown to reduce electron contamination dose to near zero. CONCLUSIONS: Experimental and simulation data were acquired for a range of field sizes to investigate off-axis irradiation on an inline MRI-Linac. The skin sparing effect was observed with off-axis irradiation, a feature that cannot be achieved to the same extent with other methods, such as bolusing, for beams at isocenter.


Asunto(s)
Electrones , Aceleradores de Partículas , Australia , Humanos , Imagen por Resonancia Magnética/métodos , Método de Montecarlo , Radiometría/métodos
15.
Med Phys ; 49(3): 1924-1931, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35023145

RESUMEN

BACKGROUND AND PURPOSE: In the current and rapidly evolving era of real-time MRI-guided radiotherapy, our radiation biology and dosimetry knowledge is being tested in a novel way. This paper presents the successful design and implementation of a portable device used to generate strong localized magnetic fields. These are ideally suited for small-scale experiments that mimic the magnetic field environment inside an MRI-linac system, or more broadly MRI-guided particle therapy as well. MATERIALS AND METHODS: A portable permanent magnet-based device employing an adjustable steel yoke and magnetic field focusing cones has been designed, constructed, and tested. The apparatus utilizes two banks of Nd 2 $_{2}$ Fe 14 $_{14}$ B permanent magnets totaling around 50 kg in mass to generate a strong magnetic field throughout a small volume between two pole tips. The yoke design allows adjustment of the pole tip gap and exchanging of the focusing cones. Further to this, beam portal holes are present in the yoke and focusing cones, allowing for radiation beams of up to 5 × $\times$ 5 cm 2 $^{2}$ to pass through the region of high magnetic field between the focusing cone tips. Finite element magnetic modeling was performed to design and characterize the performance of the device. Automated physical measurements of the magnetic field components at various locations were measured to confirm the performance. The adjustable pole gap and interchangeable cones allows rapid changing of the experimental set-up to allow different styles of measurements to be performed. RESULTS: A mostly uniform magnetic field of 1.2 T can be achieved over a volume of at least 3 × $\times$ 3 × $\times$ 3 cm 3 $^{3}$ . This can be reduced in strength to 0.3 T but increased in volume to 10 × $\times$ 10 × $\times$ 10 cm 3 $^{3}$ via removal of the cone tips and/or adjustment of the steel yoke. Although small, these volumes are sufficient to house radiation detectors, cell culture dishes, and various phantom arrangements targeted at examining small radiation field dosimetry inside magnetic field strengths that can be changed with ease. Most important is the ability to align the magnetic field both perpendicular to, or inline with, the radiation beam. To date, the system has been successfully used to conduct published research in the areas of radiation detector performance, lung phantom dosimetry, and how small clinical electron beams behave in these strong magnetic fields. CONCLUSIONS: A portable, relatively inexpensive, and simple to operate device has successfully been constructed and used for performing radiation oncology studies around the theme of MRI-guided radiotherapy. This can be in either inline and perpendicular magnetic fields of up to 1.2 T with x-ray and particle beams.


Asunto(s)
Campos Magnéticos , Imanes , Imagen por Resonancia Magnética , Aceleradores de Partículas , Radiobiología , Radiometría
16.
J Med Imaging Radiat Oncol ; 66(1): 68-78, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34176229

RESUMEN

Non-accidental injuries remain a leading cause of preventable morbidity and mortality in young children. The accurate identification of the full spectrum of injuries in children presenting with suspected abuse is essential to ensure the appropriate protective intervention is taken. The identification of occult bone fractures in this cohort is important as it raises the level of concern about the mechanism of injury and maintaining the child's safety. Radiographic imaging remains the modality of choice for skeletal assessment; however, current studies report concerns regarding the ability of radiographs to detect certain fractures in the acute stage. As such, alternative modalities for the detection of fractures have been proposed. This article reviews the current literature regarding fracture detectability and radiation dose burden of imaging modalities currently used for the assessment of occult bony injury in young children in whom non-accidental injury is suspected.


Asunto(s)
Maltrato a los Niños , Fracturas Óseas , Huesos , Niño , Maltrato a los Niños/diagnóstico , Preescolar , Fracturas Óseas/diagnóstico por imagen , Humanos , Radiografía
18.
19.
J Appl Clin Med Phys ; 22(11): 143-150, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34562341

RESUMEN

PURPOSE: To determine baseline accuracy and reproducibility of T1 and T2 relaxation times over 12 months on a dedicated radiotherapy MRI scanner. METHODS: An International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) System Phantom was scanned monthly on a 3T MRI scanner for 1 year. T1 was measured using inversion recovery (T1 -IR) and variable flip angle (T1 -VFA) sequences and T2 was measured using a multi-echo spin echo (T2 -SE) sequence. For each vial in the phantom, accuracy errors (%bias) were determined by the relative differences in measured T1 and T2 times compared to reference values. Reproducibility was measured by the coefficient of variation (CV) of T1 and T2 measurements across monthly scans. Accuracy and reproducibility were mainly assessed on vials with relaxation times expected to be in physiological ranges at 3T. RESULTS: A strong linear correlation between measured and reference relaxation times was found for all sequences tested (R2  > 0.997). Baseline bias (and CV[%]) for T1 -IR, T1 -VFA and T2 -SE sequences were +2.0% (2.1), +6.5% (4.2), and +8.5% (1.9), respectively. CONCLUSIONS: The accuracy and reproducibility of T1 and T2 on the scanner were considered sufficient for the sequences tested. No longitudinal trends of variation were deduced, suggesting less frequent measurements are required following the establishment of baselines.


Asunto(s)
Imagen por Resonancia Magnética , Humanos , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen , Reproducibilidad de los Resultados
20.
Med Phys ; 48(11): 7089-7098, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34554587

RESUMEN

PURPOSE: Cone-beam computed tomography (CBCT) is increasingly utilized in radiation therapy for image guidance and adaptive applications. While iterative reconstruction algorithms have been shown to outperform traditional filtered back-projection methods in improving image quality and reducing imaging dose, they cannot handle data truncation in the axial view, which frequently occurs in the full-fan partial-trajectory acquisition mode. This proof-of-concept study presents a novel approach on truncation artifact reduction by utilizing a priori preconditioned information as the initial input for the iterative algorithm. METHODS: Projections containing axial truncation were used for image reconstruction in extended axial field-of-view (AFOV) using the conjugate gradient least-squares (CGLS) algorithm. A priori information in the form of a planning fan-beam CT (FBCT) was repositioned in the expected CBCT imaging geometry, then further processed to dampen high-density features and convolved with a cubic Gaussian kernel to ensure differentiability for the gradient descent method. Anatomical and positional differences between the estimated and the actual imaging object were introduced to verify the efficacy of the proposed method. RESULTS: Extending the reconstruction AFOV alone could partially reduce truncation artifact. Using a priori information directly resulted in ghosting artifact when there were anatomical and positional differences between the estimated and the actual imaging object. Using a priori preconditioned information was shown to effectively reduce truncation artifact and recover peripheral information. CONCLUSIONS: Using a priori preconditioned information can effectively alleviate truncation artifact and assist recovery of peripheral information in iterative CBCT reconstruction.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador , Algoritmos , Tomografía Computarizada de Haz Cónico , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...